My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
411 West North Shore Drive_AA 2023-0601A
sbend
>
Public
>
Historic Preservation
>
2023
>
June
>
Administrative Approvals
>
411 West North Shore Drive_AA 2023-0601A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2023 4:15:32 PM
Creation date
6/1/2023 4:15:25 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
411 West North Shore Drive
HPC Document Type
Certification
HPC Local Historic District
i. West North Shore Drive
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ISure -Seal EPDM <br />Dusted Non -Reinforced Membranes <br />For Design B: Ballasted Roofing System <br />Insulation is loose -laid over the roof deck. Membrane is loose -laid over <br />the insulation with staggered factory seams and secured with a minimum <br />10 Ibs (4.5 kg) of ballast per square foot. Design C is a similar system <br />with the insulation installed on top of the membrane. To complete seams <br />between two adjoining membrane panels, apply primer to the splice area <br />in conjunction with Carlisle's Factory -Applied Tape. As an alternative, <br />Cadisle's hand -applied SecurTAPE may be used. <br />Follow these steps for splicing in temperatures below 400F (50C): <br />1. Heat the primed area of the bottom membrane with a hot-air gun as the <br />top sheet with Factory -Applied Tape is applied and pressed into place. <br />2. Prior to rolling the splice area with a 2"-wide steel hand roller, apply <br />heat to the top side of the membrane with a hot-air gun. The heated <br />surface should be hot to the touch. Be careful not to burn or blister <br />the membrane. <br />Review Carlisle specifications and details for complete installation <br />information. <br />Precautions <br />» Use proper stacking procedures to ensure sufficient stability of the <br />materials. <br />» Exercise caution when walking on wet membrane. Membranes are <br />slippery when wet. <br />» Membranes with Factory -Applied Tape should not be exposed to <br />prolonged jobsite storage temperatures in excess of 90»F (320C), <br />otherwise the shelf life of the tape may be affected. <br />» When membranes with Factory -Applied Tape are used in warm, sunny <br />weather, shade the tape end of the rolls until ready to use. <br />Stagger factory seams to avoid a double thickness of membrane. <br />» Carlisle Factory -Applied Tape has a shelf life of one year. <br />Pre -consumer Recycled Content 5% <br />Post -consumer Recycled Content 0% <br />Manufacturing Locations Carlisle, PA <br />Greenville, IL <br />Solar Reflectance Index 9 <br />Corporate Sustainability Report I yes <br />�= <br />SYNTEC SYSTEMS <br />Typical..- <br />and Characteristics <br />Physical Property <br />Test <br />Method <br />SPEC. <br />(PASS) <br />Typical <br />45_mll BO-mil <br />Toleranceon NomkelTMclowsk% <br />ASTM D412 <br />z10 <br />±10 <br />x10 <br />Weight, IbmnP(kg/" <br />0.29(1.4) <br />0.39(1.9) <br />Tensile Strength, min, psi (MPa) <br />ASTM D412 <br />1305 g) <br />1600 (11.0) <br />1600 (11.0) <br />Elongation, ultimate, min,% <br />ASTM D412 <br />300 <br />480 <br />465 <br />Tear Strength, min, Ibf/ln (kN/m) <br />ASTM D624 <br />150 (26.3) <br />200 (35o) <br />200 (35.0) <br />(Ole C) <br />Factory Seam Strength, min <br />Modified <br />Membrane <br />Membrane <br />Membrane <br />ASTM D816 <br />Rupture <br />Rupture <br />Rupture <br />ASTM D573 <br />Resistance to Heat Aging- <br />Properties after 28 days <br />240-F(116'C) <br />Tensile Strength, min, psi (MPa) <br />ASTM D412 <br />1205 (8.3) <br />1500 (10.3) <br />1450 (10.0) <br />Elongation, Ultimate, min, % <br />ASTM D412 <br />200 <br />225 <br />280 <br />Tear Strength, min, Ibf/in (kN/m) <br />ASTM D624 <br />125 (21.9) <br />215 (37.6) <br />215 (37.6) <br />Linear Dimensional Change, max,% <br />ASTM of204 <br />z1.0 <br />-0.4 <br />-0.50 <br />Ozone Resistance <br />ASTM D1149 <br />No Cracks <br />No Cracks <br />No Cracks <br />CoMxan after exposure to 100 pphm <br />Once in air for 168 hours 0104-F <br />(40-C) Specimen Is at 50%straln <br />BrNtleness Temp., max,'F ('C)' <br />ASTM D746 <br />-411l <br />-49 (-45) <br />-49 (-45) <br />ASTM D471 <br />+8, -2 <br />+2.0 <br />+2.0 <br />Resistance to water Absorpdore <br />After 7 days immersion of 158-F <br />(70-C) Change in mass, max, % <br />ASTM E96 <br />0.10 <br />0.05 <br />0.03 <br />Water Vapor Permeance- <br />Max. perms <br />(Proc.8 or OW) <br />ASTM <br />N/A <br />225 MPa <br />225 MPa <br />Rexlbllity/Torslon OMA <br />05279-08 <br />® -40'F <br />0 40'F <br />Fungi Resistance <br />ASTM G21 <br />N/A <br />0 <br />0 <br />(No 6mwth) <br />(No Growth) <br />ASTM G155 <br />No Cracks <br />No Cracks <br />No Cracks <br />Resistance to Outdoor <br />(Uhravioleq Weathering' <br />No Craarg <br />No Crazing <br />No Crating <br />Xenon -Arc. total radiant exposure <br />7.560 kJ/Mr 41,580 kJ/mr 41,580 Unix <br />at 0.70 Wlmr irradiance, 80'C <br />3,000 hm <br />16.500 the <br />16,500 bra <br />black panel temperature <br />6,000 bra <br />33,000 hrs <br />33,000 hra <br />At 0,35 Wlmr irradiance. 80-C <br />black panel temperature <br />'Not a quality control test due to the time required for the test or the complexity of the test. <br />However, all tests are run on a statistical basis to ensure overall long-term performance of the <br />sheeting. <br />Typical properties and characteristics am owed on samples tested and are rat guaranteed <br />for all samples of this product. This data and information is intended as a guide and does not <br />reflect the specification range for any particular property of this product. <br />Note: Sure -Seal Dusted Non -Reinforced EPDM membrane meats or exceeds the minimum <br />requirements set forth by ASTM D4637 for Type I non -reinforced EPDM single -ply roofing <br />membranes. <br />800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislesyntec.com <br />04.26.21 02021 Cadlele. Carlisle, Sue-Sel, Factory -Applied Tape, and SecurTAPE are bademarn of Carlisle. <br />PERMIT CODE: 605438 EPDM-1119 -"Sun-Seal EPDM Dusted No -Reinforced Membrane Product Data Sheet" LEED is a registered trademark of the U.S. Green Building Council. <br />
The URL can be used to link to this page
Your browser does not support the video tag.