My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
411 West North Shore Drive_AA 2023-0601A
sbend
>
Public
>
Historic Preservation
>
2023
>
June
>
Administrative Approvals
>
411 West North Shore Drive_AA 2023-0601A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2023 4:15:32 PM
Creation date
6/1/2023 4:15:25 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
411 West North Shore Drive
HPC Document Type
Certification
HPC Local Historic District
i. West North Shore Drive
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ISure -Seal® EPDM <br />Dusted Non -Reinforced Membranes <br />Overview <br />Carlisle's Sure -Seal EPDM Dusted Non -Reinforced membranes are <br />available in thicknesses of 45-mil (1.14 mm) and 60-mil (1.52 mm), <br />widths of up to 50' (15 m), and lengths of up to 200' (60 m). Ideal for <br />new construction and re -roofing applications, this membrane is available <br />in a Fire Retardant (FR) version that is specially formulated to inhibit the <br />spread of flame and meet or exceed code body testing criteria for fire - <br />retardant roofing membranes. <br />Features and Benefits <br />n Carlisle EPDM has 50 years of proven performance and industry - <br />leading resistance to weathering, with 41,580 kJ/mz total radiant <br />exposure without cracking or crazing <br />• Factory -Applied Tape" seam technology and a full line of Pressure - <br />Sensitive flashing accessories enhance workmanship quality <br />u Dark -colored EPDM is the smart choice in colder climates: <br />- Reduces heating costs, which are generally 3-5 times greater than <br />air conditioning costs <br />- Reduces carbon footprint by lowering heating costs <br />- Reduces safety hazards from snow and ice accumulation <br />- Reduces hazardous conditions caused by frost, dew, and ice <br />- Reduces the potential for condensation problems <br />Life Cycle Assessment using EPA's TRACI model analyzed EPDM, TPO, <br />PVC and Modified Bitumen: <br />- EPDM had the lowest global warning potential <br />- EPDM had the lowest acid rain impact <br />- EPDM had the lowest contribution to smog <br />SYNTEC SYSTEMS <br />Numerous studies and real -world experience confirm that Sure -Seal <br />EPDM's 465% elongation and weathering resistance result in superior <br />hail damage resistance (UL 2218 Class 4 Rating) <br />EPDM is the most dimensionally stable, heat -resistant membrane, and <br />stays flexible even in extremely cold conditions down to -40OF (-400C): <br />see flexibility/torsion DMA data <br />u Wide array of design choices that are UL Classified and FM Approved <br />• Industry -leading 15-, 20-, and 25-year warranties are available <br />• Carlisle manufactures all the major components of a typical roofing <br />system, including membrane, flashings, tapes, adhesives, sealants, <br />insulations, and insulating cover boards <br />Carlisle's Factory -Applied Tape Seam Technology <br />The Factory -Applied Tape process results in a reliable seam with no <br />entrapped air bubbles. Consistent placement of the Factory -Applied Tape <br />maximizes the splice area resulting in a high -quality seam. Factory - <br />Applied Tape has a shelf life of one year. <br />Productivity Boosting Features and Benefits: <br />• With Carlisle's Factory -Applied Tape, most of the �ctrvlrr <br />labor to create seams between membrane panels is oo % r <br />completed in a quality -controlled, state-of-the-art a _ Q <br />environment <br />• Factory -Applied Tape is available on all Sure -Seal , r ¢Q <br />membranes up to 30' (9 m) in width, providing the Boost <br />fastest way to complete a seam in today's roofing market <br />a Wider sheets like 165, 20% and 25' reduce the frequency of seams <br />compared to 10'-wide sheets <br />Installation <br />Sure -Seal 45-mil (1.14 mm) and 60-mil (1.52 mm) membranes are typically <br />utilized in Design A: Fully Adhered (60-mil only), Design B: Ballasted, and <br />Design C: Loose -Laid Protected roofing systems. Stagger factory seams to <br />avoid a double thickness of membrane in the splice area. <br />For Design A: Fully Adhered Hoofing System <br />Insulation is mechanically attached or adhered to the roof deck. The <br />substrate and membrane are coated with the appropriate Carlisle bonding <br />adhesive. The membrane is then rolled into place and broomed down. To <br />complete seams between two adjoining membrane panels, apply primer <br />to the splice area in conjunction with Carlisle's Factory -Applied Tape. As <br />an alternative, Carlisle's hand -applied SecurTAPE'" may be used. <br />800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislasyntec.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.