My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1. 206 East Bartlett Street_COA 2023-0403
sbend
>
Public
>
Historic Preservation
>
2023
>
April
>
1. 206 East Bartlett Street_COA 2023-0403
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2023 2:48:50 PM
Creation date
4/11/2023 2:48:36 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
206 East Bartlett Street
HPC Document Type
Certification
HPC Local Historic District
iv. River Bend
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Recommended <br />Wood frame storm windows and doors, painted to match the original, should be used but should not damage existing frames. If new sash and <br />doors are used, the existing or original materials, design and hardware should be used. When metal storm doors are used, they should be <br />painted, anodized or coated to match the existing. When awnings are used they should be of canvas material. <br />Prohibited <br />Original doors, windows, and hardware shall not be discarded when they can be restored and re-used in place. New window and door <br />openings which would alter the scale and proportion of the building should not be introduced. Inappropriate new window and door <br />features, such as aluminum and insulating glass combinations that require removal of the original windows and doors, shall not be installed. <br />Not Recommended <br />Awnings, hoods, or fake shutters made of metal, vinyl or fiberglass should not be used if they should not be used if they would detract from <br />the existing character or appearance of the building. <br />[…] <br /> <br />SITE VISIT REPORT: <br />Administrator Toering and Inspector Ross Van Overberghe visited the property on February 10th, 2023, where they <br />documented the condition of the existing fixed-in-place windows. <br /> <br />STAFF RECOMMENDATION: The proposal calls for enlarging existing window openings and creating new <br />window openings. Where the openings will be created/enlarged, the existing sills will be discarded and new 2” <br />concrete sills will be installed. Staff makes no recommendation based upon lack of information. <br /> <br />Prepared by <br />Adam Toering, Historic Preservation Administrator