Laserfiche WebLink
1..CEILING TILE AND GRID SYSTEMS <br />A. PERFORMANCE CHARACTERISTICS <br />1. SURFACE-BURNING CHARACTERISTICS: COMPLY WITH ASTM E 84; TESTING BY A QUALIFIED <br />TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING <br />AGENCY. <br />a. FLAME-SPREAD INDEX: CLASS A ACCORDING TO ASTM E 1264. <br />b. SMOKE-DEVELOPED INDEX: 50 OR LESS. <br />c. INDICATE DESIGN DESIGNATIONS FROM UL OR FROM THE LISTINGS OF ANOTHER <br />QUALIFIED TESTING AGENCY. <br />B. ACOUSTICAL TILES (WASHABLE) <br />1. BASIS OF DESIGN: ARMSTRONG "CLEAN ROOM VL 871 <br />a. SIZE: 24 INCHES x 48 INCHES x 5/8 INCHES THICK <br />b. COMPOSITION: WET FORMED MINERAL FIBER <br />c. SURFACE FINISH: FACTORY APPLIED LATEX PAINT, WHITE <br />d. FIRE PERFORMANCE: <br />1. FLAME SPREAD INDEX: LESS THAN 25 <br />2. SMOKE DEVELOPED INDEX: 50 OR LESS <br />e. EDGES: SQUARE <br />f. NOISE REDUCTION COEFFICIENT: 0.55 <br />g. ANTI-MICROBIAL TREATMENT: MANUFACTURER'S STANDARD BROAD SPECTRUM, ANTI- <br />MICROBIAL FORMULATION THAT INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM-POSITIVE AND <br />GRAM-NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR BACTERIAL GROWTH <br />WHEN TESTED ACCORDING TO ASTM D 3273, ASTM D 3274, OR ASTM G 21 AND EVALUATED <br />ACCORDING TO ASTM D 3274 OR ASTM G 21. <br />C. METAL SUSPENSION SYSTEM (WASHABLE) <br />1. BASIS OF DESIGN: ARMSTRONG "CLEAN ROOM" ALUMINUM 1 1/2" EXPOSED TEE SYSTEM <br />a.ALL SUSPENSION COMPONENTS VISIBLE SHALL RECEIVE A MICRO-ETCHED PRETREATMENT <br />PRIOR TO RECEIVING AN ELECTROSTATICALLY APPLIED ACRYLIC-POLYESTER HYBRID <br />POWDER COAT PAINT FINISH. <br />b. STRUCTURAL CLASSIFICATION: HEAVY DUTY SYSTEM. <br />c. ACCESS: UPWARD AND SIDE PIVOTED, WITH INITIAL ACCESS OPENINGS OF SIZE INDICATED <br />BELOW AND LOCATED THROUGHOUT CEILING WITHIN EACH MODULE FORMED BY MAIN AND <br />CROSS RUNNERS, WITH ADDITIONAL ACCESS AVAILABLE BY PROGRESSIVELY <br />REMOVING REMAINING ACOUSTICAL TILES. <br />d. ALL GRID COMPONENTS HAVE FACTORY APPLIED 3/32" X 3/8" (CG-10), 3/32" X 15/32" (CG-15), <br />OR 3/32" X 3/4" (CG-20) WHITE CLOSED-CELL POLYETHYLENE GASKET WITH ADHESIVE ON ONE <br />SIDE. POLYETHYLENE GASKET MUST PASS FUNGUS RESISTANCE TEST METHOD 508.1 MILL- <br />STD 810C FLAME RESISTANCE TEST FMYSS 302 WITH BURN RATE OF 4" PER MINUTE. SHORE <br />HARDNESS OF GASKET MUST BE 7 ON AA SCALE AND 51 ON OO SCALE PER ASTM D-2240. <br />THE GASKET MUST BE 2 LB. DENSITY PER CUBIC FOOT AND MEET USDA APPROVAL. <br />1.URETHANE FLOOR COATING <br />A. MANUFACTURER: BASF-UCRETE UD200 SR (HEAVY DUTY POLYURETHANE-CONCRETE FLOOR FINISH SYSTEM) <br />B.DESCRIPTION: TROWEL APPLIED, FOUR COMPONENT POLYURETHANE=CONCRETE SYSTEM WITH <br />EXCEPTIONAL RESISTANCE TO AGGRESIVE CHEMICALS, HIGH TEMPERATURES AND HEAVY IMPACT. <br />TEXTURED SURFACE FOR SAFE AND ATTRACTIVE FLOOR IN WET AND GREASY ENVIRONMENTS. <br />C.THICKNESS: 1/4" -1/2" -TAPER AT DOORS AND WHERE ADJACENT TO DISSIMILAR MATERIALS <br />D.COLOR: TO BE DETERMINED FROM LIST OF STANDARD COLORS <br />E.APPLICATION <br />1.INSTALLED BY TRAINED AND APPROVED SPECIALIST CONTRATORS <br />2. TEST CONCRETE FLOOR FOR VAPOR DRIVE IN ACCORDANCE WITH ASTM D4263 OR ASTM F1869 <br />3.USE DEGREASER TO CLEAN FLOORS OF OIL, GREASE AND OTHER BOND INHIBITING MATERIALS <br />4.REMOVE CURING AND PARTING COMPOUNDS, AND HARDENERS IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS <br />5.MECHANICALLY PROFILE FLOOR TO A MINIMUM CSP 4-5 AS DESCRIBED BY THE INTERNATIONAL <br />CONCRETE REPAIR INSTITUTE <br />6.APPLY AT LEAST A 100 S.F. FLOOR TEST IN AN INCONSPICUOUS AREA THAT MEETS THE OWNER'S <br />EXPECTATIONS <br />7.MIX COMPONENTS USING A MECHANICAL MIXER <br />8.SPREAD MIX EVENLY AND CLOSE WITH A CLEAN STEEL TROWEL. INSTALL TO A THICKNESS OF 1/4" <br />TO 1/2" DEPENDING ON REQUIREMENTS. <br />F.CURING TIME: FLOOR CAN BE RETURNED TO FULL SERVICE AFTER 12-24 HOURS AT 70 DEG F. <br />2.EPOXY FLOOR COATING <br />A. MANUFACTURER: BASF-MASTERTOP 1234 (DECORATIVE EPOXY FLOORING SYSTEM) <br />B.DESCRIPTION: TWO COMPONENT 100% SOLIDS EPOXY-RESIN BINDER WITH COLORED <br />QUARTZ AGGREGATE. THE COLORED QUARTZ IMPARTS A SLIP -RESISTANT SURFACE <br />THAT CAN BE VARIED BY THE APPLICATOR. IT IS APPLIED OVER PROPERLY PREPARED <br />SURFACES TO A THICKNESS OF 1/8" TO 3/16". <br />C.THICKNESS: 1/8 -3/8" -TAPER AT DOORS AND WHERE ADJACENT TO DISSIMILAR MATERIALS <br />D.COLOR: TO BE DETERMINED FROM LIST OF STANDARD COLORS <br />E.MIXING AND APPLICATION TO BE PER MANUFACTURER'S RECOMMENDATIONS <br />1.INSTALLED BY TRAINED AND APPROVED SPECIALIST CONTRATORS <br />2. TEST CONCRETE FLOOR FOR VAPOR DRIVE IN ACCORDANCE WITH ASTM D4263 OR ASTM F1869 <br />FLOORING <br />3.SEALED CONCRETE <br />A. MANUFACTURER: BASF <br />1.PRIMER -MASTERTOP SRS 41P METHYL-METHACRYLATE PRIMER <br /> -MASTERTOP SRS103IN ADDITIVE <br />2.TOP COAT -MASTERTOP SRS 71TC TOP COAT <br />B.DESCRIPTION: <br />1.PRIMER: SOLVENT FREE 2 COMPONENT, 100% REACTIVE PRIMER WITH SUPERIOR PENETRATION <br />AND ADHESION TO CONCRETE SURFACES. uSE WITH SRS103IN TO STRENGTHEN THE CURING <br />PROCESS. SEAL SHALL COMPLETELY SEAL THE CONCRETE RESULTING IN A UNIFORM SATIN FINISH. <br />2.TOP COAT: SOLVENT FREE, 2 -COMPONENT, 100% REACTIVE RESIN DESIGNED FOR ROLLER APPLIED <br />COATINGS. <br />C.COLOR: CLEAR -TRANSPARENT <br />D.APPLICATION -TO BE PER MANUFACTURER'S RECOMMENDATIONS <br />BASE <br />1.URETHANE -SAME MATERIAL AS FLOORING <br />2.LIGHT DUTY EPOXY -SAME MATERIAL AS FLOORING <br />WALL FINISHES <br />CEILING <br />4.ACID BRICK <br />A. MANUFACTURER: BLOME INTERNATIONAL <br />B.DESCRIPTION: <br />1. MATERIAL: FULLY VITRIFIED CERAMIC TILES, UNGLAZED, DRY PRESSURE ACCORDING TO ISO 10545, 1-17) <br />2. COLLECTION: ZF -100x200x18.5 MM (4"x8"x3/4") <br />3. SURFACE: <br />4. COLOR: <br />C.GROUT: <br />1. BLOME CP-9810 HIGH PERFORMANCE NOVOLAC EPOXY GROUT <br />D.APPLICATION -TO BE PER MANUFACTURER'S RECOMMENDATIONS <br />FLOOR COATING <br />TYPICAL KEYWAY <br />1/2" x 1" (12MM x 25MM) <br />FLOOR COATING <br />EXTEND COATING UP <br />AT WALL AND CURB <br />LOCATIONS <br />FLOOR COATING <br />TYPICAL KEYWAY <br />1/2"x1") <br />FLOOR COATING <br />APPROVED <br />SEALANT <br />TYPICAL KEYWAY <br />1/2"x1/2") <br />FLOOR COATING <br />CONTROL JOINT <br />BACKER ROD <br />TYPICAL KEYWAY <br />1/2"x1/2") <br />COVE DETAIL AT WALLDETAIL AT CONTROL JOINT <br />EXTERIOR PAINTING (BASED ON SHERWIN WILLIAMS) <br />A. CONCRETE: <br />1. LATEX <br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE <br />b. TOPCOAT: DURATION EXTERIOR LATEX SATIN; K33 <br />2. ELASTOMERIC, SMOOTH <br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE <br />b. INTERMEDIATE COAT: CONFLEX XL ELASTOMERIC HIGH BUILD SMOOTH; A5-400 <br />c. TOPCOAT: CONFLEX XL ELASTOMERIC HIGH BUILD SMOOTH; A5-400 <br />B. CONCRETE BLOCK <br />1. LATEX <br />a. FIRST COAT: S-W CONFLEX BLOCK FILLER, CF01 SERIES (75-100 S.F. PER GALLON) <br />b. SECOND COAT: S-W A-100 EXTERIOR LATEX GLOSS, A8 SERIES <br />c. THIRD COAT: S-W-A-100 EXTERIOR LATEX GLOSS, A8 SERIES <br />2. ELASTOMERIC SYSTEMS <br />a. FIRST COAT: S-W LOXON ACYLIC BLOCK SURFACER, LX01 SERIES <br />b. SECOND COAT: S-W CONFLEX XL ELASTOMERIC HIGH BUILD COATING, CF-11 SERIES <br />c. THIRD COAT: S-W CONFLEX XL ELASTOMERIC HIGH BUILD COATING, CF-11 SERIES <br />C.METAL DOOR AND FRAMES; METAL STAIRS; HANDRAILS AND GUARDRAILS; MISCELLANEOUS METALS <br />(FERROUS PRIMED, ZINC-COATED, AND ALUMINUM) <br />1. WATER BASED URETHANE, GLOSS LEVEL 6 <br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE <br />b. INTERMEDIATE COAT: ACROLON 100 POLYURETHANE, B65-720 <br />c. INTERMEDIATE COAT: ACROLON 100 POLYURETHANE, B65-720 <br />D.STRUCTURAL STEEL -EXPOSED <br />1. WATER BASED URETHANE, GLOSS LEVEL 6 <br />a. PRIMER COAT: SHOP APPLIED <br />1. TOUCH-UP IN FIELD AS REQUIRED <br />b. INTERMEDIATE COAT: ACROLON 100 POLYURETHANE, B65-720 <br />c. INTERMEDIATE COAT: ACROLON 100 POLYURETHANE, B65-720 <br />INTERIOR PAINTING (BASED ON SHERWIN WILLIAMS) <br />A.CONCRETE AND CONCRETE BLOCK WALLS <br />1. LATEX, GLOSS LEVEL 3 EGGSHELL <br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE <br />b. INTERMEDIATE COAT: S-W PROMAR 200 ZERO VOC EG-SHEL, B20-2600 <br />c. TOPCOAT: S-W PROMAR 200 ZERO VOC EG-SHEL, B20-2600 <br />B.DUCT SURFACES VISIBLE THROUGH GRILLES OR DIFFUSERS <br />1. LATEX, GLOSS LEVEL 1 FLAT: <br />a. PRIMER: PRO-CRYL UNIVERSAL PRIMER, B66-310 SERIES <br />b. TOPCOAT: PROMAR 400 INTERIOR LATEX FLAT, B30W400 SERIES <br />c. COLOR: FLAT BLACK <br />C.METAL DOORS AND FRAMES <br />1. WATERBORNE ACRYLIC, GLOSS LEVEL 5, SEMI GLOSS <br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE <br />b. INTERMEDIATE COAT: PRE-CATALYZED WATERBASED EPOXY, K46-150 <br />c. TOP COAT: PRE-CATALYZED WATERBASED EPOXY, K46-150 <br />D.FLOOR MARKINGS: <br />1. ALKYD SEMI-GLOSS FINISH <br />a. FIRST COAT: SETFAST AISLE MARKING PAINT -TM2173 LEAD FREE YELLOW <br />b. SECOND COAT: SETFAST AISLE MARKING PAINT -TM2173 LEAD FREE YELLOW <br />URETHANE WALL COATING: (BASED ON TNEMEC STRANLOK) <br />CONCRETE AND CONCRETE WALLS <br />1. SERIES 201 EPOXOPRIME 6.0 -8.0 MILS <br />2. SERIES 270 STRANLOK 25.0 -40.0 MILS <br />3. SERIES 280 TNEME-GLAZE 6.0 -8.0 MILS <br />SPECIALTIES <br />II.FIRE PROTECTION SPECIALTIES <br />A. FIRE EXTINGUISHERS <br />1. JL INDUSTRIES -JL COSMIC 20E MULTI-PURPOSE ABC FIRE EXTINGUISHER; OR EQUAL <br />a. 10A-120BC UL RATING <br />b. 20 LBS <br />c. DRY CHEMICAL -FLUIDIZED AND SILICONIZED MONO AMMONIUM PHOSPHATE POWDER <br />B.FIRE EXTINGUISHER CABINET <br />1. PROVIDE "FIRE EXTINGUISHER: DECAL FOR EACH CABINET -ORIENT LETTERS VERTICALLY <br />2. PROVIDE STANDARD FIXED DOOR PULL AT EACH CABINET <br />3. KEYS TO DOOR LOCKS: THREE PER LOCK <br />4. JL INDUSTRIES -COSMOPOLITAN; OR EQUAL <br />a. DOOR AND TRIM CONSTRUCTION <br />1. #4 STANLESS STEEL. FLUSH CABINET DOORS WITH A 5/8 INCH DOOR STOP ARE <br />ATTACHED BY A CONTINUOUS HINGE AND EQUIPPED WITH ZINC PLATED HANDLE AND <br />ROLLER CATCH. ALL MODELS HAVE A 1 3/4 INCH WIDE TRIM ON FRAME AND 1 1/4 INCH <br />TRIM ON DOOR WITH GLAZING <br />b. DOOR STYLE WITH HANDLE <br />1. FULL GLAZING <br />2. FULL GLAZING WITH SAF-T-LOK <br />3. HORIZONTAL DUO PANEL <br />4. HORIZONTAL DUAL PANEL WITH SAF-T-LOK <br />5. SOLID DOOR <br />6. SOLID WITH SAF-T-LOK <br />7. SOLID WITH CYLINDER LOCK -NO HANDLE <br />8. VERTICAL DUO <br />9. VERTICAL DUO WITH SAF-T-LOK <br />10. SOLID WITH 2 INCH x 4 INCH VIEW WINDOW AND SAF-T-LOK <br />c. DOOR GLAZING <br />1. CLEAR ACRYLIC <br />2. CLEAR WIRE GLASS WITH SAFETY FILM <br />3. BRONZE ACRYLIC <br />4. GRAY ACRYLIC <br />5. CLEAR TEMPERED GLASS <br />6. LAMINATED SAFETY GLASS <br />d. TRIM STYLE AND DEPTH <br />1. RECESSED 3/8 INCH FLAT TRIM, SEMI RECESSED -1 1/4 INCH, 1 1/2 INCH SQUARE EDGE <br />OR 2 1/2, 3, 4, 4 1/2 INCH ROLLED EDGE (4" HAS RECESSED FLUSH PULL) SURFACE-MOUNT <br />MODELS HAVE A SQUARE EDGE <br />e. TUB: <br />1. CONSTRUCTED OF COLD ROLLED STEEL WITH WHITE POWDER-COAT STANDARD <br />FINISH. SURFACE-MOUNT MODELS HAVE A STAINLESS TUB <br />f. STANDARD "J" HOOK WALL BRACKET <br />g. OPTIONAL FEATURES <br />1. OPTIONAL TUB COLOR <br />a. BLACK <br />b. RED <br />2. FUTURA "FIRE" PULL <br />a. MILL ALUMINUM <br />b. RED <br />c. WHITE <br />3. FLUSH PULL HANDLE (PRH) <br />4. POLISHED CHROME PULL (PUCH) <br />5. STAINLESS STEEL TUB -#4 FINISH <br />6. OTHER STAINLESS STEEL FINISH <br />7. ROLLED EDGE SURFACE MOUNT CABINET <br />V. FIRESTOPPING <br />A. MATERIALS <br />1. THROUGH PENETRATION FIRESTOP SYSTEMS (HILTI, INC; OR EQUAL) <br />a. VOC CONTENT NOT TO EXCEED 250 g/L <br />b. BASE PRODUCTS <br />1. FS-ONE INTUMESCENT FIRESTOP SEALANT <br />2. CP 604 SELF-LEVELING FIRESTOP SEALANT <br />3. CP 620 FIRE FOAM <br />4. CP 606 FLEXIBLE FIRESTOP SEALANT <br />5. CFS-S SIL ELASTOMERIC FIRESTOP SEALANT <br />2. FIRE RESISTIVE JOINTS <br />a. VOC CONTENT NOT TO EXCEED 250 g/L <br />b. BASE PRODUCTS <br />1. CFS-SP WB FIRESTOP JOINT SPRAY <br />2. CFS-S-SIL ELASTOMERIC FIRESTOP SEALANT <br />3. CP 606 FLEXIBLE FIRESTOP SEALANT <br />5. CP 604 SELF-LEVELING FIRESTOP SEALANT <br />3. INTUMESCENT JOINTS <br />a. FOR USE AT TOP OF WALL APPLICATION <br />b. BASE PRODUCT <br />1. SPEEDFLEX BY SPECIFIED TECHNOLOGIES, INC <br />4. FIRESTOP DEVICES <br />a. FACTORY ASSEMBLED COLLARS LINED WITH INTUMESCENT MATERIAL SIZED TO FIT SPECIFIC <br />OUTSIDE DIAMETER OF PENETRATING ITEM <br />b. BASE PRODUCT <br />1. CP 680-P CAST-IN-PLACE FIRESTOP DEVICE <br />2. CP 680-M CAST-IN-PLACE FIRSTOP DEVICE <br />3. CP 681 TUB BOX KIT <br />4. CFS-DID FIRESTOP DEVICE <br />5. INTUMESCENT PADS, WALL OPENING PROTECTIVE MATERIALS <br />a. INTUMESCENT, NON-CURING PADS OR INSERTS FOR PROTECTION OF ELECTRIC PANELS, <br />SWITCH AND RECEPTACLE BOXES, MEDICAL GAS OUTLETS AND VALVE BOXES AND OTHER <br />ITEMS RECESSED IN FACE OF FIRE RATED WALLS <br />b. BASE PRODUCT <br />1. CFS-P-PA FIRESTOP PUTTY PAD <br />2. CP 617 FIRESTOP PUTTY PAD <br />3. HILTI BIOX INSERT <br />6. FIRE RATED CABLE PATHWAYS <br />a. USAGE: <br />1. CABLES PASSING THROUGH FIRE RATED FLOORS OR WALLS SHALL PASS THROUGH <br />FIRE RATED CABLE PATHWAY DEVICES MADE FROM INTUMESCENT MATERIAL THAT <br />ADJUSTS AUTOMATICALLY TO CABLE ADDITIONS OR SUBTRACTIONS <br />b. PRODUCT DESCRIPTION AND REQUIREMENTS <br />1. PATHWAY DEVICE MODULES COMPRISED OF STEEL RACEWAY AND INTUMESCENT PADS <br />WITH ADJUSTABLE SMOKE SEAL SLEEVE <br />2. F-RATING EQUAL TO THE RATING OF BARRIER THE DEVICE PENETRATES <br />3. PATHWAY DEVICES SHALL BE CAPABLE OF ALLOWING A 0 TO 100 PERCENT FILL OF <br />CABLES <br />4. SIZE TO ACCOMODATE QUANTITY AND SIZE OF ELECTRICAL WIRES AND DATA CABLES <br />INDICATED PLUS 100 PERCENT OF EXPANSION <br />c. BASE PRODUCTS <br />1. CP 653 SPEED SLEEVE <br />a. USE IN CONJUNCTION WITH CFS-SL GP WHEN MORE THAN ONE DEVICE IS <br />REQUIRED <br />2. CFS-CC FIRESTOP CABLE COLLAR <br />7. FIRESTOP PUTTY <br />1. FIRESTOP PUTTY SHALL BE PROVIDED AND INSTALLED AT, BUT NOT LIMITED TO, THE <br />GAP BETWEEN WIRE, CABLING, OR BOTH, EXITING AN OPEN END OF CONDUIT, WHERE <br />CONDUIT PENETRATES ONE OR BOTH SIDES OF A SMOKE OR FIRE RATED WALL ASSEMBLY <br />2. BASE PRODUCTS <br />a. CP 618 FIRESTOP PUTTY STICK <br />b. CFS-PL FIRESTOP PLUG <br />8. FIRESTOP BLOCKS <br />1. RE-ENTERABLE, NON-CURING, INTUMESCENT FLEXIBLE BLOCK <br />2. BASE PRODUCTS <br />a. CFS-BL FIRE BLOCK <br />b. CFS-PL FIRESTOP PLUG <br />B. GENERAL <br />1. THROUGH PENETRATION FIRESTOP SYSTEMS <br />a. SELECT EACH FIRESTOP SYSTEM BASED ON FIELD CONDITIONS, INCLUDING PENETRATION <br />TYPE, SHAPE, SIZE, QUANTITIES, AND PHYSICAL POSITION WITHIN OPENING <br />b. FIRESTOP ASSEMBLIES AT RATED WALLS <br />1. MINIMUM FIRE (F) RATING FOR FIRESTOP ASSEMBLIES IN WALLS SHALL EQUAL THAT <br />OF THE WALL, BUT NOT LESS THAN 1 HOUR <br />2. MINIMUM TEMPERATURE (T) RATING OF FIRESTOP ASSEMBLIES IN WALLS MAY EQUAL <br />ZERO <br />3. SMOKE BARRIER: IN ADDITION TO (F) RATING, (L) RATING OF 5 CFM / SF MAX. <br />c. FIRESTOP ASSEMBLIES AT RATED FLOORS AND ROOFS <br />1. MINIMUM FIRE (F) RATING FOR FIRESTOP ASSEMBLIES IN FLOORS OR ROOFS SHALL <br />EQUAL THAT OF THE FLOOR OR ROOF BEING PENETRATED, BUT NOT LESS THAN 1 HOUR <br />a. EXCEPTION 1: THE T-RATING MAY EQUAL ZERO WHEN PORTION OF <br />PENETRATION, ABOVE OR BELOW FLOOR, IS CONTAINED WITHIN A WALL <br />b. EXCEPTION 2: FIRESTOPS ARE NOT REQUIRED FOR FLOOR PENETRATIONS <br />WITHIN A 2-HOUR RATED SHAFT ENCLOSURE <br />d. VOIDS IN WALL WITH NO PENETRATIONS <br />1. FILL WITH APPROVED THROUGH PENETRATION FIRESTOPPING SYSTEM <br />e. PENETRATING DUCTS WITH DAMPERS <br />1. UTILIZE ONLY FIRESTOP MATERIALS WHICH ARE INCLUDED IN DAMPERS CLASSIFICATION <br />2. DO NOT INSTALL FIRESTOP SYSTEM THAT HAMPERS PERFORMANCE OF DAMPERS <br />THERMAL AND MOISTURE PROTECTION <br /> I. BUILDING INSULATION <br />A.RIGID BOARD INSULATION EXTRUDED POLYSTYRENE (XPS) <br />1. MINIMUM COMPRESSIVE STRENGTH 25 PSI <br />2. SURFACE BURNING CHARACTERISTICS <br />a. FLAME SPREAD 25 OR LESS <br />b. SMOKE DEVELOPED LESS THAN 450 <br />3. THERMAL RESISTANCE PER ASTM C518 -5.0 PER INCH <br />2. INSULATED METAL PANELS <br />A. WALL PANELS -METL SPAN "CF MESA" -OR EQUAL <br />1. CONCEALED FASTENER, INSULATED METAL WALL PANELS WITH FOAM CORE. STRUCTURAL METAL <br />PANELS CONSISTING OF EXTERIOR METAL SHEET AND INTERIOR METAL SHEET WITH MATCHING <br />FACTORY FOAMED-IN-PLACE POLYURETHANE CORE IN THERMALLY <br />SEPARATED PROFILE, WITH TONGUE AND GROOVE PANEL EDGES. ATTACH TO STRUCTURE USING <br />CONCEALED FASTENERS. <br />a. WIDTH:36 <br />b. THICKNESS:2" -R VALUE OF 15 AT 40 DEG. <br />c. LENGTH:8'-0" TO 53'-0" <br />d. PROFILE:UNEMBOSSED <br />e. EXTERIOR FACE:G-90 GALVANIZED OR AZ-50 ALUMINUM ZINC COATED STEEL IN 24 GA. <br />f. INTERIOR FACE:G-90 GALVANIZED OR AZ-50 ALUMINUM-ZINC COATED STEEL IN 24 GA. <br />g. CORE:FOAMED-IN-PLACE, NON-cfc & ZERO <br />2. FINISH: <br />a. EXTERIOR FACE <br />1. MODIFIED SILICONE POLYESTER TWO COAT SYSTEM -OR <br />2. FLUOROPOLYMER TWO-COAT SYSTEM <br />b. INTERIOR FACE <br />1. MODIFIED SILICONE POLYESTER TWO COAT SYSTEM -OR <br />2. FLUOROPOLYMER TWO-COAT SYSTEM <br />3. COLOR: -TO BE SELECTED FROM LIST OF STANDARD COLORS <br />B. CEILING PANELS WALL PANELS -METL SPAN "CF MESA" -OR EQUAL <br />1. INSULATED METAL CEILING PANELS WITH FOAM CORE. STRUCTURAL METAL <br />PANELS CONSISTING OF EXTERIOR METAL SHEET AND INTERIOR METAL SHEET WITH MATCHING <br />FACTORY FOAMED-IN-PLACE POLYURETHANE CORE IN THERMALLY <br />SEPARATED PROFILE, WITH TONGUE AND GROOVE PANEL EDGES. ATTACH TO STRUCTURE USING <br />CONCEALED FASTENERS. <br />a. WIDTH:36 <br />b. THICKNESS:4" -R VALUE OF 32 AT 40 DEG. <br />c. LENGTH:10'-0" <br />d. PROFILE:UNEMBOSSED <br />e. EXTERIOR FACE:G-90 GALVANIZED OR AZ-50 ALUMINUM ZINC COATED STEEL IN 24 GA. <br />f. INTERIOR FACE:G-90 GALVANIZED OR AZ-50 ALUMINUM-ZINC COATED STEEL IN 24 GA. <br />g. CORE:FOAMED-IN-PLACE, NON-cfc & ZERO <br />2. FINISH: <br />a. INTERIOR FACE <br />1. MODIFIED SILICONE POLYESTER TWO COAT SYSTEM -OR <br />2. FLUOROPOLYMER TWO-COAT SYSTEM <br />3. COLOR: -TO BE SELECTED FROM LIST OF STANDARD COLORS <br />3. ALUMINUM SUPPORT SYSTEM -METL SPAN "HEF-T" ALUMINUM CEILING SUPPORT <br />a. DIMENSIONS: 5" WIDE (3/16" THICK) FLANGE, 3" WEB (1/4" THICK) LEG <br />b. HOLES: PRE-DRILLED HOLES AT 6" O.C. ON VERTICAL FLANGE; 12" O.C. ON LEG <br />c. FINISH: PAINTED WHITE <br />3. MECHANICALLY FASTENED ROOF MEMBRANE <br />4. ROOF SPECIALTIES AND ACCESSORIES <br />A.PREFINISHED METAL COPING: <br />1. "PAC-CONTINUOUS CLEAT COPING" BY PETERSON ALUMINUM CORPORATION -OR EQUAL <br />2. 22 GA. STEEL <br />3. WIND UPLIFT FM I-90; FM I-105; AND FM I-120; TESTING PER ANSI/SPRI/FM 4435/ES-1 <br />4. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD COLORS <br />B.ROOF HATCH <br />1. BILCO SERIES S -30 INCHES x 36 INCHES; OR EQUAL <br />2. MATERIALS <br />a. CURB AND COVER MATERIAL: <br />1. 0.067 INCH (14 GA.) STEEL SHEET; ZINC COATED, GALVANIZED, ASTM A653, G90. <br />b. COVER LINER MATERIAL: <br />1. 0.026 INCH (22 GA.) STEEL SHEET; ZINC COATED, GALVANIZED, ASTM A653, G90 <br />c. FINISH: <br />1. SHOP PRIMER: MANUFACTURER'S STANDARD PRIMER, MINIMUM 2.0 MILS DRY <br />2. FIELD FINISH: PAINT AS SPECIFICIED IN SECTION 09 <br />3. HATCH GUARDRAIL <br />a. BIL-GUARD BY BILCO; OR EQUAL <br />5. SEALANTS <br />A.EXTERIOR JOINT SEALANTS <br />1. MATERIALS <br />a. JS-1: URETHANE ARCHITECTURAL SEALANT <br />1. TWO PART, NON SAG, MOVEMENT CAPABILITY PLUS / MINUS 50 PERCENT <br />2. ASTM C920, TYPE M, GRADE NS, CLASS 50 <br />3. BASE PRODUCT: TREMCO DYMERIC 240 FC; OR EQUAL <br />b. JS-2: URETHANE SELF LEVELING PAVING SEALANT; TRAFFIC BEARING <br />1. TWO PART, MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT <br />2. ASTM C920, TYPE M, GRAPE P, CLASS 25 USDA APPROVED <br />3. BASE PRODUCT: TREMCO THC-900; OR EQUAL <br />c. JS-3: URETHANE NON SAG PAVING SEALANT, SLOPE GRADE, TRAFFIC BEARING <br />1. MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT <br />2. ASTM C920, TYPE S OR TYPE M, GRADE NS, CLASS 25 <br />3. BASE PRODUCT: TREMCO VULKEM 116; OR EQUAL <br />d. JS-4: SILICONE ARCHITECTURAL SEALANT <br />1. ONE PART, MOVEMENT CAPABILITY PLUS 100 PERCENT MINUS 50 PERCENT <br />2. ASTM C920, TYPE S, GRANE NS, CLASS 100/50 <br />3. BASE PRODUCT: TREMCO SPECTREM 1; OR EQUAL <br />e. JS-8: PRE-COMPRESSED EXPANDING FOAM SEALANT <br />1. MOVEMENT CAPABILITY OF PLUS/MINUS 25 PERCENT <br />2. COLOR: BLACK <br />3. BASE PRODUCT: EMSEAL 25V EXPANDING FOAM SEALANT; OR EQUAL <br />f. JS-9: PRE-COMPRESSED EXPANDING FOAM SEALANT <br />1. HIGH DENSITY POLYURETHANE, IMPREGNATED WITH POLYMER MODIFIED ACYLIC <br />AND FACED WITH FACTORY APPLIED SILICONE <br />2. MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT <br />3. BASE PRODUCT: EMSEAL COLORSEAL; OR EQUAL <br />g. BACKER ROD <br />1. POLYETHYLENE, POLYETHLENE JACKETED POLYURETHANE FOAM, FLEXIBLE, <br />NON-ABSORBENT, NON-BITUMINOUS MATERIAL RECOMMENDED BY SEALANT <br />MANUFACTURER <br />2. SCHEDULE <br />a. JOINTS IN EXTERIOR INSULATION AND FINISH SYSTEM -JS-1 OR JS-4 <br />b. INTERIOR JOINTS, UNPAINTED, LOCATED IN OR ADJACENT TO UNPAINTED METERIALS OR <br />SURFACES -JS-1 OR JS-4 <br />c. INTERIOR CONTROL JOINTS IN UNPAINTED MASONRY AND GYPSUM BOARD -JS-1 OR JS-4 <br />d. EXTERIOR AND INTERIOR PAVING JOINTS -JS-2 <br />e. FLOOR JOINTS, CONTROL AND EXPANSION JOINTS -JS-2 <br />f. EXTERIOR AND INTERIOR PAVING JOINTS, SLOPING -JS-3 <br />g. EXTERIOR JOINTS EXCEPT PAVING -JS-4 <br />h. PRIMARY OR SECONDARY SEAL IN CONCRETE OR MASONRY JOINTS -JS-8 <br />i. PRIMARY SEAL IN METAL SUBSTRATES, MASONRY, OR CONCRETE JOINTS -JS-9 <br />DIVISION 07 -THERMAL AND MOISTURE PROTECTION (CONTINUED) <br /> B.INTERIOR JOINT SEALANTS <br />1. MATERIALS <br />a. JS-1: URETHANE ARCHITECTURAL SEALANT <br />1. TWO PART, NON-SAG, MOVEMENT CAPABILITY PLUS / MINUS 50 PERCENT <br />2. ASTM C920, TYPE M, GRADE NS, CLASS 50 <br />3. BASE PRODUCT: TREMCO DYMERIC 240FC; OR EQUAL <br />b. JS-2: URETHANE SELF LEVELING PAVING SEALANT; TRAFFIC BEARING <br />1. TWO PART, MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT <br />2. ASTM C920, TYPE M, GRADE P, CLASS 25. USDA APPROVED <br />3. BASE PRODUCT: TREMCO THC-900; OR EQUAL <br />c. JS-3: URETHANE, NON-SAG PAVING SEALANT, SLOPE GRADE, TRAFFIC BEARING <br />1. MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT <br />2. ASTM C920, TYPE S OR TYPE M, GRADE NS, CLASS 25 <br />3. BASE PRODUCT: TREMCO VULKEM 116; OR EQUAL <br />d. JS-4: SILICONE ARCHITECTURAL SEALANT <br />1. ONE PART, MOVEMENT CAPABILITY PLUS 100 PERCENT MINUS 50 PERCENT <br />2. ASTM C920, TYPE S, GRADE NS, CLASS 100/50 <br />3. BASE PRODUCT: TREMCO SPECTREM 1; OR EQUAL <br />e. JS-5: SILICONIZED ACYLIC LATEX OR POLYMER SEALANT <br />1. ONE PART, FUNGUS RESISTANT, PAINTABLE <br />2. USDA APPROVED <br />3. NOT COMPATIBLE WITH EPOXY COATINGS <br />4. BASE PRODUCT: PECORA, AC-20 + SILICONE (ASTM C834, TYPE OP, GRADE NF); OR EQUAL <br />f. JS-6: SILICONE SANITARY SEALANT <br />1. ONE PART, MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT <br />2. ASTM C920, TYPE S, GRADE NS, CLASS 25 <br />3. COLOR: WHITE <br />4. FUNGUS RESISTANT <br />5. BASE PRODUCT: TREMCO, TREMSIL 200; OR EQUAL <br />g. JS-7: SILICONE SANITARY SEALANT <br />1. ONE PART, NO BACTERIAL GROWTH <br />2. ASTM C920, TYPE S, GRADE NS, CLASS 50 <br />3. NEUTRAL CURE <br />4. COLOR: WHITE <br />5. USDA APPROVED <br />6. BASE PRODUCT: PECORA, 898; OR EQUAL <br />h. JOINT CLEANER, PRIMER, BOND BREAKER <br />1. AS RECOMMENDED BY SEALANT MANUFACTURER <br />i. BACKER ROD <br />1. POLYTHYLENE, POLYETHYLENE JACKETED POLYURETHANE FOAM, FLEXIBLE, NON- <br />ABSORBENT, NON-BITUMINOUS MATERIAL RECOMMENDED BY SEALANT MANUFACTURER <br />2. SCHEDULE <br />a. INTERIOR JOINTS, UNPAINTED, LOCATED IN OR ADJACENT TO UNPAINTED MATERIALS OR SURFACES <br />JS-1 OR JS-4 <br />b. INTERIOR CONTROL JOINTS IN UNPAINTED MASONRY AND GYPSUM BOARD -JS-1 OR JS-4 <br />c. EXTERIOR AND INTERIOR PAVING JOINTS -JS-2 <br />d. FLOOR JOINTS, CONTROL AND EXPANSION JOINTS -JS-2 <br />e. INTERIOR PAVING JOINTS, SLOPING -JS-3 <br />f. INTERIOR CONTROL JOINTS IN PAINTED (NON-EPOXY FINISHES) MASONRY AND GYPSUM BOARD -JS-5 <br />g. INTERIOR JOINTS -SANITARY; JOINTS IN CERAMIC TILE, AROUND TOILET ROOM VANITIES, PLUMBING <br />FIXTURES, AND KITCHEN EQUIPMENT -JS-6 OR JS-7 <br />h. INTERIOR JOINTS -GMP BOUNDARY LINES AND SPACES WITHIN GMP LAB ZONES RECEIVING EPOXY <br />FINISHES <br />1. SEAL SPACES THAT WILL HARBOR VERMIN OR PROMOTE BACTERIAL GROWTH, PROVIDE <br />FOR PRESSURIZATION, OR MAINTAIN ACOUSTIC SEPARATION <br />2. APPLY SEALANT TO BOND TO EPOXY COATINGS. DO NOT BOND SEALANT TO SUBSTRATES <br />SCHEDULED FOR EPOXY COATINGS <br />3. SEAL CREVICES, SPACES, GAPS, AND OPENINGS, INCLUDING, BUT NOT LIMITED TO THE <br />FOLLOWING: <br />a. FIXTURES AND COVER PLATES <br />b. JOINTS AROUND DOOR AND WINDOW FRAMES <br />c. WALL / WALL JOINTS -DISSIMILAR MATERIALS <br />d. WALL JOINTS <br />e. WALL / DECK JOINTS WHERE WALLS EXTEND ABOVE CEILING TO STRUCTURE ABOVE <br />f. WALL AND CEILING PENETRATIONS <br />g. WALL CORNER GUARDS <br />h. CEILING DIFFUSERS -HARD CEILINGS <br />i. CEILING / LIGHT FIXTURES -HARD CEILINGS <br />j. PERIMTER TRIM ANGLE FRO GASKETED CEILINGS <br />k. DOOR KICK / ARMOR PLATES <br />l. DOOR GLAZING STOPS <br />m. CONTROL JOINTS <br />n. CASEWORK <br />I <br />PROJECT NUMBER: <br />jedson.com <br />One Centennial Plaza <br />705 Central Ave <br />Cincinnati, OH 45202 <br />P: 513.965.5999 <br />F: 513.965.5998 <br />THIS DRAWING AND ITS RELATED COPYRIGHTS, INTELLECTUAL PROPERTY RIGHTS AND TRADE SECRETS ARE THE PROPERTY OF JEDSON <br />ENGINEERING, INC. AND CONTAINS CONFIDENTIAL INFORMATION, WHICH SHALL NOT BE USED, COPIED OR DISCLOSED WITHOUT WRITTEN PERMISSION <br />OF JEDSON ENGINEERING, INC. ©2013 JEDSON ENGINEERING, INC. ALL RIGHTS RESERVED. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />ABCDEFGHKLM <br />REVISIONS <br />ABCDEFGHJKLM <br />PROJ. NO.: <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />SCALE:11/4/2021 1:10:43 PMApprover <br />Checker <br />Designer <br />200199 <br />McCORMICK & COMPANY <br />ROOM FINISH SCHEDULESB-A501SB-A501 -I <br />200199 <br />ROOM SCHEDULE <br />ROOM NUMBER ROOM NAME FLOOR FINISH BASE FINISH WALL FINISH CEILING FINISH <br />CEILING <br />HEIGHT COMMENTS SCHEDULE <br />139 EXISTING TANK FARM YES <br />140 NEW TANK FARM URETHANE COATING URETHANE COATING URETHANE COATING NONE YES <br />141 TANK FARM VEST. EPOXY COATING EPOXY COATING EPOXY PAINT NONE 0"YES <br />142 NEW TANKER UNLOADING URETHANE COATING URETHANE COATING URETHANE COATING NONE YES <br />143 ELECTRIC ROOM EPOXY COATING EPOXY COATING LATEX PAINT NONE 0"YES <br />144 ANALYTICAL LAB EPOXY COATING 4" LIGHT DUTY EPOXY COVE EPOXY PAINT WASHABLE SUSP. ACOUST. TILE 9'-0"YES <br />145 EX. MAINTENANCE ROOM EXISTING EXISTING EXISTING NONE YES <br />146 MAINTENANCE SEALED CONCRETE NONE LATEX PAINT NONE YES <br />147 CORRIDOR URETHANE COATING URETHANE COATING EPOXY PAINT WASHABLE SUSP. ACOUST. TILE 9'-0"YES <br />148 MECHANICAL POLISHED CONCRETE NONE LATEX PAINT INSULATED METAL PANELS 20'-0"YES <br />149 MAKING ACID BRICK ACID BRICK URETHANE COATING INSULATED METAL PANELS 20'-0" URETHANE COATING ON CONC. COLUMN BASES YES <br />150 MILLING ACID BRICK ACID BRICK URETHANE COATING INSULATED METAL PANELS 20'-0"YES <br />151 FILLING SUITE ACID BRICK ACID BRICK / URETHANE COATING STAINLESS STEEL INSULATED METAL PANELS INSULATED METAL PANELS 15'-0"YES <br />152 TOILET RM VEST. EPOXY COATING EPOXY COATING INSULATED METAL WALL PANELS 9'-0"YES <br />153 TOILET RM. EPOXY COATING EPOXY COATING INSULATED METAL WALL PANELS 9'-0"YES <br />201 MECHANICAL ROOM MEZZANINE SEALED CONCRETE NONE NONE NONE YES <br />3" = 1'-0"2 FINISH DETAILS <br />6" = 1'-0"3 FLOOR COATING DETAILS <br />3425 LATHROP ST. SOUTH BEND, INDIANA 46628 <br />NO DESCRIPTION DATE DB CB AB <br />B LAYOUT D 7/13/2021 DLR DLR <br />C LAYOUT E 8/3/2021 DLR DLR <br />D LAYOUT PROGRESS 8/11/2021 DLR DLR <br />E LAYOUT G 8/25/2021 DLR DLR <br />F REVISIONS 9/14/2021 DLR DLR <br />G GENERAL REVISIONS 9/20/2021 DLR DLR <br />H GENERAL REVISIONS 10/1/2021 DLR DLR <br />I ISSUED FOR REVIEW 11/01/2021 DLR DLR