1..CEILING TILE AND GRID SYSTEMS
<br />A. PERFORMANCE CHARACTERISTICS
<br />1. SURFACE-BURNING CHARACTERISTICS: COMPLY WITH ASTM E 84; TESTING BY A QUALIFIED
<br />TESTING AGENCY. IDENTIFY PRODUCTS WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING
<br />AGENCY.
<br />a. FLAME-SPREAD INDEX: CLASS A ACCORDING TO ASTM E 1264.
<br />b. SMOKE-DEVELOPED INDEX: 50 OR LESS.
<br />c. INDICATE DESIGN DESIGNATIONS FROM UL OR FROM THE LISTINGS OF ANOTHER
<br />QUALIFIED TESTING AGENCY.
<br />B. ACOUSTICAL TILES (WASHABLE)
<br />1. BASIS OF DESIGN: ARMSTRONG "CLEAN ROOM VL 871
<br />a. SIZE: 24 INCHES x 48 INCHES x 5/8 INCHES THICK
<br />b. COMPOSITION: WET FORMED MINERAL FIBER
<br />c. SURFACE FINISH: FACTORY APPLIED LATEX PAINT, WHITE
<br />d. FIRE PERFORMANCE:
<br />1. FLAME SPREAD INDEX: LESS THAN 25
<br />2. SMOKE DEVELOPED INDEX: 50 OR LESS
<br />e. EDGES: SQUARE
<br />f. NOISE REDUCTION COEFFICIENT: 0.55
<br />g. ANTI-MICROBIAL TREATMENT: MANUFACTURER'S STANDARD BROAD SPECTRUM, ANTI-
<br />MICROBIAL FORMULATION THAT INHIBITS FUNGUS, MOLD, MILDEW, AND GRAM-POSITIVE AND
<br />GRAM-NEGATIVE BACTERIA AND SHOWING NO MOLD, MILDEW, OR BACTERIAL GROWTH
<br />WHEN TESTED ACCORDING TO ASTM D 3273, ASTM D 3274, OR ASTM G 21 AND EVALUATED
<br />ACCORDING TO ASTM D 3274 OR ASTM G 21.
<br />C. METAL SUSPENSION SYSTEM (WASHABLE)
<br />1. BASIS OF DESIGN: ARMSTRONG "CLEAN ROOM" ALUMINUM 1 1/2" EXPOSED TEE SYSTEM
<br />a.ALL SUSPENSION COMPONENTS VISIBLE SHALL RECEIVE A MICRO-ETCHED PRETREATMENT
<br />PRIOR TO RECEIVING AN ELECTROSTATICALLY APPLIED ACRYLIC-POLYESTER HYBRID
<br />POWDER COAT PAINT FINISH.
<br />b. STRUCTURAL CLASSIFICATION: HEAVY DUTY SYSTEM.
<br />c. ACCESS: UPWARD AND SIDE PIVOTED, WITH INITIAL ACCESS OPENINGS OF SIZE INDICATED
<br />BELOW AND LOCATED THROUGHOUT CEILING WITHIN EACH MODULE FORMED BY MAIN AND
<br />CROSS RUNNERS, WITH ADDITIONAL ACCESS AVAILABLE BY PROGRESSIVELY
<br />REMOVING REMAINING ACOUSTICAL TILES.
<br />d. ALL GRID COMPONENTS HAVE FACTORY APPLIED 3/32" X 3/8" (CG-10), 3/32" X 15/32" (CG-15),
<br />OR 3/32" X 3/4" (CG-20) WHITE CLOSED-CELL POLYETHYLENE GASKET WITH ADHESIVE ON ONE
<br />SIDE. POLYETHYLENE GASKET MUST PASS FUNGUS RESISTANCE TEST METHOD 508.1 MILL-
<br />STD 810C FLAME RESISTANCE TEST FMYSS 302 WITH BURN RATE OF 4" PER MINUTE. SHORE
<br />HARDNESS OF GASKET MUST BE 7 ON AA SCALE AND 51 ON OO SCALE PER ASTM D-2240.
<br />THE GASKET MUST BE 2 LB. DENSITY PER CUBIC FOOT AND MEET USDA APPROVAL.
<br />1.URETHANE FLOOR COATING
<br />A. MANUFACTURER: BASF-UCRETE UD200 SR (HEAVY DUTY POLYURETHANE-CONCRETE FLOOR FINISH SYSTEM)
<br />B.DESCRIPTION: TROWEL APPLIED, FOUR COMPONENT POLYURETHANE=CONCRETE SYSTEM WITH
<br />EXCEPTIONAL RESISTANCE TO AGGRESIVE CHEMICALS, HIGH TEMPERATURES AND HEAVY IMPACT.
<br />TEXTURED SURFACE FOR SAFE AND ATTRACTIVE FLOOR IN WET AND GREASY ENVIRONMENTS.
<br />C.THICKNESS: 1/4" -1/2" -TAPER AT DOORS AND WHERE ADJACENT TO DISSIMILAR MATERIALS
<br />D.COLOR: TO BE DETERMINED FROM LIST OF STANDARD COLORS
<br />E.APPLICATION
<br />1.INSTALLED BY TRAINED AND APPROVED SPECIALIST CONTRATORS
<br />2. TEST CONCRETE FLOOR FOR VAPOR DRIVE IN ACCORDANCE WITH ASTM D4263 OR ASTM F1869
<br />3.USE DEGREASER TO CLEAN FLOORS OF OIL, GREASE AND OTHER BOND INHIBITING MATERIALS
<br />4.REMOVE CURING AND PARTING COMPOUNDS, AND HARDENERS IN ACCORDANCE WITH
<br />MANUFACTURER'S INSTRUCTIONS
<br />5.MECHANICALLY PROFILE FLOOR TO A MINIMUM CSP 4-5 AS DESCRIBED BY THE INTERNATIONAL
<br />CONCRETE REPAIR INSTITUTE
<br />6.APPLY AT LEAST A 100 S.F. FLOOR TEST IN AN INCONSPICUOUS AREA THAT MEETS THE OWNER'S
<br />EXPECTATIONS
<br />7.MIX COMPONENTS USING A MECHANICAL MIXER
<br />8.SPREAD MIX EVENLY AND CLOSE WITH A CLEAN STEEL TROWEL. INSTALL TO A THICKNESS OF 1/4"
<br />TO 1/2" DEPENDING ON REQUIREMENTS.
<br />F.CURING TIME: FLOOR CAN BE RETURNED TO FULL SERVICE AFTER 12-24 HOURS AT 70 DEG F.
<br />2.EPOXY FLOOR COATING
<br />A. MANUFACTURER: BASF-MASTERTOP 1234 (DECORATIVE EPOXY FLOORING SYSTEM)
<br />B.DESCRIPTION: TWO COMPONENT 100% SOLIDS EPOXY-RESIN BINDER WITH COLORED
<br />QUARTZ AGGREGATE. THE COLORED QUARTZ IMPARTS A SLIP -RESISTANT SURFACE
<br />THAT CAN BE VARIED BY THE APPLICATOR. IT IS APPLIED OVER PROPERLY PREPARED
<br />SURFACES TO A THICKNESS OF 1/8" TO 3/16".
<br />C.THICKNESS: 1/8 -3/8" -TAPER AT DOORS AND WHERE ADJACENT TO DISSIMILAR MATERIALS
<br />D.COLOR: TO BE DETERMINED FROM LIST OF STANDARD COLORS
<br />E.MIXING AND APPLICATION TO BE PER MANUFACTURER'S RECOMMENDATIONS
<br />1.INSTALLED BY TRAINED AND APPROVED SPECIALIST CONTRATORS
<br />2. TEST CONCRETE FLOOR FOR VAPOR DRIVE IN ACCORDANCE WITH ASTM D4263 OR ASTM F1869
<br />FLOORING
<br />3.SEALED CONCRETE
<br />A. MANUFACTURER: BASF
<br />1.PRIMER -MASTERTOP SRS 41P METHYL-METHACRYLATE PRIMER
<br /> -MASTERTOP SRS103IN ADDITIVE
<br />2.TOP COAT -MASTERTOP SRS 71TC TOP COAT
<br />B.DESCRIPTION:
<br />1.PRIMER: SOLVENT FREE 2 COMPONENT, 100% REACTIVE PRIMER WITH SUPERIOR PENETRATION
<br />AND ADHESION TO CONCRETE SURFACES. uSE WITH SRS103IN TO STRENGTHEN THE CURING
<br />PROCESS. SEAL SHALL COMPLETELY SEAL THE CONCRETE RESULTING IN A UNIFORM SATIN FINISH.
<br />2.TOP COAT: SOLVENT FREE, 2 -COMPONENT, 100% REACTIVE RESIN DESIGNED FOR ROLLER APPLIED
<br />COATINGS.
<br />C.COLOR: CLEAR -TRANSPARENT
<br />D.APPLICATION -TO BE PER MANUFACTURER'S RECOMMENDATIONS
<br />BASE
<br />1.URETHANE -SAME MATERIAL AS FLOORING
<br />2.LIGHT DUTY EPOXY -SAME MATERIAL AS FLOORING
<br />WALL FINISHES
<br />CEILING
<br />4.ACID BRICK
<br />A. MANUFACTURER: BLOME INTERNATIONAL
<br />B.DESCRIPTION:
<br />1. MATERIAL: FULLY VITRIFIED CERAMIC TILES, UNGLAZED, DRY PRESSURE ACCORDING TO ISO 10545, 1-17)
<br />2. COLLECTION: ZF -100x200x18.5 MM (4"x8"x3/4")
<br />3. SURFACE:
<br />4. COLOR:
<br />C.GROUT:
<br />1. BLOME CP-9810 HIGH PERFORMANCE NOVOLAC EPOXY GROUT
<br />D.APPLICATION -TO BE PER MANUFACTURER'S RECOMMENDATIONS
<br />FLOOR COATING
<br />TYPICAL KEYWAY
<br />1/2" x 1" (12MM x 25MM)
<br />FLOOR COATING
<br />EXTEND COATING UP
<br />AT WALL AND CURB
<br />LOCATIONS
<br />FLOOR COATING
<br />TYPICAL KEYWAY
<br />1/2"x1")
<br />FLOOR COATING
<br />APPROVED
<br />SEALANT
<br />TYPICAL KEYWAY
<br />1/2"x1/2")
<br />FLOOR COATING
<br />CONTROL JOINT
<br />BACKER ROD
<br />TYPICAL KEYWAY
<br />1/2"x1/2")
<br />COVE DETAIL AT WALLDETAIL AT CONTROL JOINT
<br />EXTERIOR PAINTING (BASED ON SHERWIN WILLIAMS)
<br />A. CONCRETE:
<br />1. LATEX
<br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE
<br />b. TOPCOAT: DURATION EXTERIOR LATEX SATIN; K33
<br />2. ELASTOMERIC, SMOOTH
<br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE
<br />b. INTERMEDIATE COAT: CONFLEX XL ELASTOMERIC HIGH BUILD SMOOTH; A5-400
<br />c. TOPCOAT: CONFLEX XL ELASTOMERIC HIGH BUILD SMOOTH; A5-400
<br />B. CONCRETE BLOCK
<br />1. LATEX
<br />a. FIRST COAT: S-W CONFLEX BLOCK FILLER, CF01 SERIES (75-100 S.F. PER GALLON)
<br />b. SECOND COAT: S-W A-100 EXTERIOR LATEX GLOSS, A8 SERIES
<br />c. THIRD COAT: S-W-A-100 EXTERIOR LATEX GLOSS, A8 SERIES
<br />2. ELASTOMERIC SYSTEMS
<br />a. FIRST COAT: S-W LOXON ACYLIC BLOCK SURFACER, LX01 SERIES
<br />b. SECOND COAT: S-W CONFLEX XL ELASTOMERIC HIGH BUILD COATING, CF-11 SERIES
<br />c. THIRD COAT: S-W CONFLEX XL ELASTOMERIC HIGH BUILD COATING, CF-11 SERIES
<br />C.METAL DOOR AND FRAMES; METAL STAIRS; HANDRAILS AND GUARDRAILS; MISCELLANEOUS METALS
<br />(FERROUS PRIMED, ZINC-COATED, AND ALUMINUM)
<br />1. WATER BASED URETHANE, GLOSS LEVEL 6
<br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE
<br />b. INTERMEDIATE COAT: ACROLON 100 POLYURETHANE, B65-720
<br />c. INTERMEDIATE COAT: ACROLON 100 POLYURETHANE, B65-720
<br />D.STRUCTURAL STEEL -EXPOSED
<br />1. WATER BASED URETHANE, GLOSS LEVEL 6
<br />a. PRIMER COAT: SHOP APPLIED
<br />1. TOUCH-UP IN FIELD AS REQUIRED
<br />b. INTERMEDIATE COAT: ACROLON 100 POLYURETHANE, B65-720
<br />c. INTERMEDIATE COAT: ACROLON 100 POLYURETHANE, B65-720
<br />INTERIOR PAINTING (BASED ON SHERWIN WILLIAMS)
<br />A.CONCRETE AND CONCRETE BLOCK WALLS
<br />1. LATEX, GLOSS LEVEL 3 EGGSHELL
<br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE
<br />b. INTERMEDIATE COAT: S-W PROMAR 200 ZERO VOC EG-SHEL, B20-2600
<br />c. TOPCOAT: S-W PROMAR 200 ZERO VOC EG-SHEL, B20-2600
<br />B.DUCT SURFACES VISIBLE THROUGH GRILLES OR DIFFUSERS
<br />1. LATEX, GLOSS LEVEL 1 FLAT:
<br />a. PRIMER: PRO-CRYL UNIVERSAL PRIMER, B66-310 SERIES
<br />b. TOPCOAT: PROMAR 400 INTERIOR LATEX FLAT, B30W400 SERIES
<br />c. COLOR: FLAT BLACK
<br />C.METAL DOORS AND FRAMES
<br />1. WATERBORNE ACRYLIC, GLOSS LEVEL 5, SEMI GLOSS
<br />a. PRIMER COAT: RECOMMENDED BY TOPCOAT MANUFACTURER FOR EACH SUBSTRATE
<br />b. INTERMEDIATE COAT: PRE-CATALYZED WATERBASED EPOXY, K46-150
<br />c. TOP COAT: PRE-CATALYZED WATERBASED EPOXY, K46-150
<br />D.FLOOR MARKINGS:
<br />1. ALKYD SEMI-GLOSS FINISH
<br />a. FIRST COAT: SETFAST AISLE MARKING PAINT -TM2173 LEAD FREE YELLOW
<br />b. SECOND COAT: SETFAST AISLE MARKING PAINT -TM2173 LEAD FREE YELLOW
<br />URETHANE WALL COATING: (BASED ON TNEMEC STRANLOK)
<br />CONCRETE AND CONCRETE WALLS
<br />1. SERIES 201 EPOXOPRIME 6.0 -8.0 MILS
<br />2. SERIES 270 STRANLOK 25.0 -40.0 MILS
<br />3. SERIES 280 TNEME-GLAZE 6.0 -8.0 MILS
<br />SPECIALTIES
<br />II.FIRE PROTECTION SPECIALTIES
<br />A. FIRE EXTINGUISHERS
<br />1. JL INDUSTRIES -JL COSMIC 20E MULTI-PURPOSE ABC FIRE EXTINGUISHER; OR EQUAL
<br />a. 10A-120BC UL RATING
<br />b. 20 LBS
<br />c. DRY CHEMICAL -FLUIDIZED AND SILICONIZED MONO AMMONIUM PHOSPHATE POWDER
<br />B.FIRE EXTINGUISHER CABINET
<br />1. PROVIDE "FIRE EXTINGUISHER: DECAL FOR EACH CABINET -ORIENT LETTERS VERTICALLY
<br />2. PROVIDE STANDARD FIXED DOOR PULL AT EACH CABINET
<br />3. KEYS TO DOOR LOCKS: THREE PER LOCK
<br />4. JL INDUSTRIES -COSMOPOLITAN; OR EQUAL
<br />a. DOOR AND TRIM CONSTRUCTION
<br />1. #4 STANLESS STEEL. FLUSH CABINET DOORS WITH A 5/8 INCH DOOR STOP ARE
<br />ATTACHED BY A CONTINUOUS HINGE AND EQUIPPED WITH ZINC PLATED HANDLE AND
<br />ROLLER CATCH. ALL MODELS HAVE A 1 3/4 INCH WIDE TRIM ON FRAME AND 1 1/4 INCH
<br />TRIM ON DOOR WITH GLAZING
<br />b. DOOR STYLE WITH HANDLE
<br />1. FULL GLAZING
<br />2. FULL GLAZING WITH SAF-T-LOK
<br />3. HORIZONTAL DUO PANEL
<br />4. HORIZONTAL DUAL PANEL WITH SAF-T-LOK
<br />5. SOLID DOOR
<br />6. SOLID WITH SAF-T-LOK
<br />7. SOLID WITH CYLINDER LOCK -NO HANDLE
<br />8. VERTICAL DUO
<br />9. VERTICAL DUO WITH SAF-T-LOK
<br />10. SOLID WITH 2 INCH x 4 INCH VIEW WINDOW AND SAF-T-LOK
<br />c. DOOR GLAZING
<br />1. CLEAR ACRYLIC
<br />2. CLEAR WIRE GLASS WITH SAFETY FILM
<br />3. BRONZE ACRYLIC
<br />4. GRAY ACRYLIC
<br />5. CLEAR TEMPERED GLASS
<br />6. LAMINATED SAFETY GLASS
<br />d. TRIM STYLE AND DEPTH
<br />1. RECESSED 3/8 INCH FLAT TRIM, SEMI RECESSED -1 1/4 INCH, 1 1/2 INCH SQUARE EDGE
<br />OR 2 1/2, 3, 4, 4 1/2 INCH ROLLED EDGE (4" HAS RECESSED FLUSH PULL) SURFACE-MOUNT
<br />MODELS HAVE A SQUARE EDGE
<br />e. TUB:
<br />1. CONSTRUCTED OF COLD ROLLED STEEL WITH WHITE POWDER-COAT STANDARD
<br />FINISH. SURFACE-MOUNT MODELS HAVE A STAINLESS TUB
<br />f. STANDARD "J" HOOK WALL BRACKET
<br />g. OPTIONAL FEATURES
<br />1. OPTIONAL TUB COLOR
<br />a. BLACK
<br />b. RED
<br />2. FUTURA "FIRE" PULL
<br />a. MILL ALUMINUM
<br />b. RED
<br />c. WHITE
<br />3. FLUSH PULL HANDLE (PRH)
<br />4. POLISHED CHROME PULL (PUCH)
<br />5. STAINLESS STEEL TUB -#4 FINISH
<br />6. OTHER STAINLESS STEEL FINISH
<br />7. ROLLED EDGE SURFACE MOUNT CABINET
<br />V. FIRESTOPPING
<br />A. MATERIALS
<br />1. THROUGH PENETRATION FIRESTOP SYSTEMS (HILTI, INC; OR EQUAL)
<br />a. VOC CONTENT NOT TO EXCEED 250 g/L
<br />b. BASE PRODUCTS
<br />1. FS-ONE INTUMESCENT FIRESTOP SEALANT
<br />2. CP 604 SELF-LEVELING FIRESTOP SEALANT
<br />3. CP 620 FIRE FOAM
<br />4. CP 606 FLEXIBLE FIRESTOP SEALANT
<br />5. CFS-S SIL ELASTOMERIC FIRESTOP SEALANT
<br />2. FIRE RESISTIVE JOINTS
<br />a. VOC CONTENT NOT TO EXCEED 250 g/L
<br />b. BASE PRODUCTS
<br />1. CFS-SP WB FIRESTOP JOINT SPRAY
<br />2. CFS-S-SIL ELASTOMERIC FIRESTOP SEALANT
<br />3. CP 606 FLEXIBLE FIRESTOP SEALANT
<br />5. CP 604 SELF-LEVELING FIRESTOP SEALANT
<br />3. INTUMESCENT JOINTS
<br />a. FOR USE AT TOP OF WALL APPLICATION
<br />b. BASE PRODUCT
<br />1. SPEEDFLEX BY SPECIFIED TECHNOLOGIES, INC
<br />4. FIRESTOP DEVICES
<br />a. FACTORY ASSEMBLED COLLARS LINED WITH INTUMESCENT MATERIAL SIZED TO FIT SPECIFIC
<br />OUTSIDE DIAMETER OF PENETRATING ITEM
<br />b. BASE PRODUCT
<br />1. CP 680-P CAST-IN-PLACE FIRESTOP DEVICE
<br />2. CP 680-M CAST-IN-PLACE FIRSTOP DEVICE
<br />3. CP 681 TUB BOX KIT
<br />4. CFS-DID FIRESTOP DEVICE
<br />5. INTUMESCENT PADS, WALL OPENING PROTECTIVE MATERIALS
<br />a. INTUMESCENT, NON-CURING PADS OR INSERTS FOR PROTECTION OF ELECTRIC PANELS,
<br />SWITCH AND RECEPTACLE BOXES, MEDICAL GAS OUTLETS AND VALVE BOXES AND OTHER
<br />ITEMS RECESSED IN FACE OF FIRE RATED WALLS
<br />b. BASE PRODUCT
<br />1. CFS-P-PA FIRESTOP PUTTY PAD
<br />2. CP 617 FIRESTOP PUTTY PAD
<br />3. HILTI BIOX INSERT
<br />6. FIRE RATED CABLE PATHWAYS
<br />a. USAGE:
<br />1. CABLES PASSING THROUGH FIRE RATED FLOORS OR WALLS SHALL PASS THROUGH
<br />FIRE RATED CABLE PATHWAY DEVICES MADE FROM INTUMESCENT MATERIAL THAT
<br />ADJUSTS AUTOMATICALLY TO CABLE ADDITIONS OR SUBTRACTIONS
<br />b. PRODUCT DESCRIPTION AND REQUIREMENTS
<br />1. PATHWAY DEVICE MODULES COMPRISED OF STEEL RACEWAY AND INTUMESCENT PADS
<br />WITH ADJUSTABLE SMOKE SEAL SLEEVE
<br />2. F-RATING EQUAL TO THE RATING OF BARRIER THE DEVICE PENETRATES
<br />3. PATHWAY DEVICES SHALL BE CAPABLE OF ALLOWING A 0 TO 100 PERCENT FILL OF
<br />CABLES
<br />4. SIZE TO ACCOMODATE QUANTITY AND SIZE OF ELECTRICAL WIRES AND DATA CABLES
<br />INDICATED PLUS 100 PERCENT OF EXPANSION
<br />c. BASE PRODUCTS
<br />1. CP 653 SPEED SLEEVE
<br />a. USE IN CONJUNCTION WITH CFS-SL GP WHEN MORE THAN ONE DEVICE IS
<br />REQUIRED
<br />2. CFS-CC FIRESTOP CABLE COLLAR
<br />7. FIRESTOP PUTTY
<br />1. FIRESTOP PUTTY SHALL BE PROVIDED AND INSTALLED AT, BUT NOT LIMITED TO, THE
<br />GAP BETWEEN WIRE, CABLING, OR BOTH, EXITING AN OPEN END OF CONDUIT, WHERE
<br />CONDUIT PENETRATES ONE OR BOTH SIDES OF A SMOKE OR FIRE RATED WALL ASSEMBLY
<br />2. BASE PRODUCTS
<br />a. CP 618 FIRESTOP PUTTY STICK
<br />b. CFS-PL FIRESTOP PLUG
<br />8. FIRESTOP BLOCKS
<br />1. RE-ENTERABLE, NON-CURING, INTUMESCENT FLEXIBLE BLOCK
<br />2. BASE PRODUCTS
<br />a. CFS-BL FIRE BLOCK
<br />b. CFS-PL FIRESTOP PLUG
<br />B. GENERAL
<br />1. THROUGH PENETRATION FIRESTOP SYSTEMS
<br />a. SELECT EACH FIRESTOP SYSTEM BASED ON FIELD CONDITIONS, INCLUDING PENETRATION
<br />TYPE, SHAPE, SIZE, QUANTITIES, AND PHYSICAL POSITION WITHIN OPENING
<br />b. FIRESTOP ASSEMBLIES AT RATED WALLS
<br />1. MINIMUM FIRE (F) RATING FOR FIRESTOP ASSEMBLIES IN WALLS SHALL EQUAL THAT
<br />OF THE WALL, BUT NOT LESS THAN 1 HOUR
<br />2. MINIMUM TEMPERATURE (T) RATING OF FIRESTOP ASSEMBLIES IN WALLS MAY EQUAL
<br />ZERO
<br />3. SMOKE BARRIER: IN ADDITION TO (F) RATING, (L) RATING OF 5 CFM / SF MAX.
<br />c. FIRESTOP ASSEMBLIES AT RATED FLOORS AND ROOFS
<br />1. MINIMUM FIRE (F) RATING FOR FIRESTOP ASSEMBLIES IN FLOORS OR ROOFS SHALL
<br />EQUAL THAT OF THE FLOOR OR ROOF BEING PENETRATED, BUT NOT LESS THAN 1 HOUR
<br />a. EXCEPTION 1: THE T-RATING MAY EQUAL ZERO WHEN PORTION OF
<br />PENETRATION, ABOVE OR BELOW FLOOR, IS CONTAINED WITHIN A WALL
<br />b. EXCEPTION 2: FIRESTOPS ARE NOT REQUIRED FOR FLOOR PENETRATIONS
<br />WITHIN A 2-HOUR RATED SHAFT ENCLOSURE
<br />d. VOIDS IN WALL WITH NO PENETRATIONS
<br />1. FILL WITH APPROVED THROUGH PENETRATION FIRESTOPPING SYSTEM
<br />e. PENETRATING DUCTS WITH DAMPERS
<br />1. UTILIZE ONLY FIRESTOP MATERIALS WHICH ARE INCLUDED IN DAMPERS CLASSIFICATION
<br />2. DO NOT INSTALL FIRESTOP SYSTEM THAT HAMPERS PERFORMANCE OF DAMPERS
<br />THERMAL AND MOISTURE PROTECTION
<br /> I. BUILDING INSULATION
<br />A.RIGID BOARD INSULATION EXTRUDED POLYSTYRENE (XPS)
<br />1. MINIMUM COMPRESSIVE STRENGTH 25 PSI
<br />2. SURFACE BURNING CHARACTERISTICS
<br />a. FLAME SPREAD 25 OR LESS
<br />b. SMOKE DEVELOPED LESS THAN 450
<br />3. THERMAL RESISTANCE PER ASTM C518 -5.0 PER INCH
<br />2. INSULATED METAL PANELS
<br />A. WALL PANELS -METL SPAN "CF MESA" -OR EQUAL
<br />1. CONCEALED FASTENER, INSULATED METAL WALL PANELS WITH FOAM CORE. STRUCTURAL METAL
<br />PANELS CONSISTING OF EXTERIOR METAL SHEET AND INTERIOR METAL SHEET WITH MATCHING
<br />FACTORY FOAMED-IN-PLACE POLYURETHANE CORE IN THERMALLY
<br />SEPARATED PROFILE, WITH TONGUE AND GROOVE PANEL EDGES. ATTACH TO STRUCTURE USING
<br />CONCEALED FASTENERS.
<br />a. WIDTH:36
<br />b. THICKNESS:2" -R VALUE OF 15 AT 40 DEG.
<br />c. LENGTH:8'-0" TO 53'-0"
<br />d. PROFILE:UNEMBOSSED
<br />e. EXTERIOR FACE:G-90 GALVANIZED OR AZ-50 ALUMINUM ZINC COATED STEEL IN 24 GA.
<br />f. INTERIOR FACE:G-90 GALVANIZED OR AZ-50 ALUMINUM-ZINC COATED STEEL IN 24 GA.
<br />g. CORE:FOAMED-IN-PLACE, NON-cfc & ZERO
<br />2. FINISH:
<br />a. EXTERIOR FACE
<br />1. MODIFIED SILICONE POLYESTER TWO COAT SYSTEM -OR
<br />2. FLUOROPOLYMER TWO-COAT SYSTEM
<br />b. INTERIOR FACE
<br />1. MODIFIED SILICONE POLYESTER TWO COAT SYSTEM -OR
<br />2. FLUOROPOLYMER TWO-COAT SYSTEM
<br />3. COLOR: -TO BE SELECTED FROM LIST OF STANDARD COLORS
<br />B. CEILING PANELS WALL PANELS -METL SPAN "CF MESA" -OR EQUAL
<br />1. INSULATED METAL CEILING PANELS WITH FOAM CORE. STRUCTURAL METAL
<br />PANELS CONSISTING OF EXTERIOR METAL SHEET AND INTERIOR METAL SHEET WITH MATCHING
<br />FACTORY FOAMED-IN-PLACE POLYURETHANE CORE IN THERMALLY
<br />SEPARATED PROFILE, WITH TONGUE AND GROOVE PANEL EDGES. ATTACH TO STRUCTURE USING
<br />CONCEALED FASTENERS.
<br />a. WIDTH:36
<br />b. THICKNESS:4" -R VALUE OF 32 AT 40 DEG.
<br />c. LENGTH:10'-0"
<br />d. PROFILE:UNEMBOSSED
<br />e. EXTERIOR FACE:G-90 GALVANIZED OR AZ-50 ALUMINUM ZINC COATED STEEL IN 24 GA.
<br />f. INTERIOR FACE:G-90 GALVANIZED OR AZ-50 ALUMINUM-ZINC COATED STEEL IN 24 GA.
<br />g. CORE:FOAMED-IN-PLACE, NON-cfc & ZERO
<br />2. FINISH:
<br />a. INTERIOR FACE
<br />1. MODIFIED SILICONE POLYESTER TWO COAT SYSTEM -OR
<br />2. FLUOROPOLYMER TWO-COAT SYSTEM
<br />3. COLOR: -TO BE SELECTED FROM LIST OF STANDARD COLORS
<br />3. ALUMINUM SUPPORT SYSTEM -METL SPAN "HEF-T" ALUMINUM CEILING SUPPORT
<br />a. DIMENSIONS: 5" WIDE (3/16" THICK) FLANGE, 3" WEB (1/4" THICK) LEG
<br />b. HOLES: PRE-DRILLED HOLES AT 6" O.C. ON VERTICAL FLANGE; 12" O.C. ON LEG
<br />c. FINISH: PAINTED WHITE
<br />3. MECHANICALLY FASTENED ROOF MEMBRANE
<br />4. ROOF SPECIALTIES AND ACCESSORIES
<br />A.PREFINISHED METAL COPING:
<br />1. "PAC-CONTINUOUS CLEAT COPING" BY PETERSON ALUMINUM CORPORATION -OR EQUAL
<br />2. 22 GA. STEEL
<br />3. WIND UPLIFT FM I-90; FM I-105; AND FM I-120; TESTING PER ANSI/SPRI/FM 4435/ES-1
<br />4. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD COLORS
<br />B.ROOF HATCH
<br />1. BILCO SERIES S -30 INCHES x 36 INCHES; OR EQUAL
<br />2. MATERIALS
<br />a. CURB AND COVER MATERIAL:
<br />1. 0.067 INCH (14 GA.) STEEL SHEET; ZINC COATED, GALVANIZED, ASTM A653, G90.
<br />b. COVER LINER MATERIAL:
<br />1. 0.026 INCH (22 GA.) STEEL SHEET; ZINC COATED, GALVANIZED, ASTM A653, G90
<br />c. FINISH:
<br />1. SHOP PRIMER: MANUFACTURER'S STANDARD PRIMER, MINIMUM 2.0 MILS DRY
<br />2. FIELD FINISH: PAINT AS SPECIFICIED IN SECTION 09
<br />3. HATCH GUARDRAIL
<br />a. BIL-GUARD BY BILCO; OR EQUAL
<br />5. SEALANTS
<br />A.EXTERIOR JOINT SEALANTS
<br />1. MATERIALS
<br />a. JS-1: URETHANE ARCHITECTURAL SEALANT
<br />1. TWO PART, NON SAG, MOVEMENT CAPABILITY PLUS / MINUS 50 PERCENT
<br />2. ASTM C920, TYPE M, GRADE NS, CLASS 50
<br />3. BASE PRODUCT: TREMCO DYMERIC 240 FC; OR EQUAL
<br />b. JS-2: URETHANE SELF LEVELING PAVING SEALANT; TRAFFIC BEARING
<br />1. TWO PART, MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT
<br />2. ASTM C920, TYPE M, GRAPE P, CLASS 25 USDA APPROVED
<br />3. BASE PRODUCT: TREMCO THC-900; OR EQUAL
<br />c. JS-3: URETHANE NON SAG PAVING SEALANT, SLOPE GRADE, TRAFFIC BEARING
<br />1. MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT
<br />2. ASTM C920, TYPE S OR TYPE M, GRADE NS, CLASS 25
<br />3. BASE PRODUCT: TREMCO VULKEM 116; OR EQUAL
<br />d. JS-4: SILICONE ARCHITECTURAL SEALANT
<br />1. ONE PART, MOVEMENT CAPABILITY PLUS 100 PERCENT MINUS 50 PERCENT
<br />2. ASTM C920, TYPE S, GRANE NS, CLASS 100/50
<br />3. BASE PRODUCT: TREMCO SPECTREM 1; OR EQUAL
<br />e. JS-8: PRE-COMPRESSED EXPANDING FOAM SEALANT
<br />1. MOVEMENT CAPABILITY OF PLUS/MINUS 25 PERCENT
<br />2. COLOR: BLACK
<br />3. BASE PRODUCT: EMSEAL 25V EXPANDING FOAM SEALANT; OR EQUAL
<br />f. JS-9: PRE-COMPRESSED EXPANDING FOAM SEALANT
<br />1. HIGH DENSITY POLYURETHANE, IMPREGNATED WITH POLYMER MODIFIED ACYLIC
<br />AND FACED WITH FACTORY APPLIED SILICONE
<br />2. MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT
<br />3. BASE PRODUCT: EMSEAL COLORSEAL; OR EQUAL
<br />g. BACKER ROD
<br />1. POLYETHYLENE, POLYETHLENE JACKETED POLYURETHANE FOAM, FLEXIBLE,
<br />NON-ABSORBENT, NON-BITUMINOUS MATERIAL RECOMMENDED BY SEALANT
<br />MANUFACTURER
<br />2. SCHEDULE
<br />a. JOINTS IN EXTERIOR INSULATION AND FINISH SYSTEM -JS-1 OR JS-4
<br />b. INTERIOR JOINTS, UNPAINTED, LOCATED IN OR ADJACENT TO UNPAINTED METERIALS OR
<br />SURFACES -JS-1 OR JS-4
<br />c. INTERIOR CONTROL JOINTS IN UNPAINTED MASONRY AND GYPSUM BOARD -JS-1 OR JS-4
<br />d. EXTERIOR AND INTERIOR PAVING JOINTS -JS-2
<br />e. FLOOR JOINTS, CONTROL AND EXPANSION JOINTS -JS-2
<br />f. EXTERIOR AND INTERIOR PAVING JOINTS, SLOPING -JS-3
<br />g. EXTERIOR JOINTS EXCEPT PAVING -JS-4
<br />h. PRIMARY OR SECONDARY SEAL IN CONCRETE OR MASONRY JOINTS -JS-8
<br />i. PRIMARY SEAL IN METAL SUBSTRATES, MASONRY, OR CONCRETE JOINTS -JS-9
<br />DIVISION 07 -THERMAL AND MOISTURE PROTECTION (CONTINUED)
<br /> B.INTERIOR JOINT SEALANTS
<br />1. MATERIALS
<br />a. JS-1: URETHANE ARCHITECTURAL SEALANT
<br />1. TWO PART, NON-SAG, MOVEMENT CAPABILITY PLUS / MINUS 50 PERCENT
<br />2. ASTM C920, TYPE M, GRADE NS, CLASS 50
<br />3. BASE PRODUCT: TREMCO DYMERIC 240FC; OR EQUAL
<br />b. JS-2: URETHANE SELF LEVELING PAVING SEALANT; TRAFFIC BEARING
<br />1. TWO PART, MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT
<br />2. ASTM C920, TYPE M, GRADE P, CLASS 25. USDA APPROVED
<br />3. BASE PRODUCT: TREMCO THC-900; OR EQUAL
<br />c. JS-3: URETHANE, NON-SAG PAVING SEALANT, SLOPE GRADE, TRAFFIC BEARING
<br />1. MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT
<br />2. ASTM C920, TYPE S OR TYPE M, GRADE NS, CLASS 25
<br />3. BASE PRODUCT: TREMCO VULKEM 116; OR EQUAL
<br />d. JS-4: SILICONE ARCHITECTURAL SEALANT
<br />1. ONE PART, MOVEMENT CAPABILITY PLUS 100 PERCENT MINUS 50 PERCENT
<br />2. ASTM C920, TYPE S, GRADE NS, CLASS 100/50
<br />3. BASE PRODUCT: TREMCO SPECTREM 1; OR EQUAL
<br />e. JS-5: SILICONIZED ACYLIC LATEX OR POLYMER SEALANT
<br />1. ONE PART, FUNGUS RESISTANT, PAINTABLE
<br />2. USDA APPROVED
<br />3. NOT COMPATIBLE WITH EPOXY COATINGS
<br />4. BASE PRODUCT: PECORA, AC-20 + SILICONE (ASTM C834, TYPE OP, GRADE NF); OR EQUAL
<br />f. JS-6: SILICONE SANITARY SEALANT
<br />1. ONE PART, MOVEMENT CAPABILITY PLUS / MINUS 25 PERCENT
<br />2. ASTM C920, TYPE S, GRADE NS, CLASS 25
<br />3. COLOR: WHITE
<br />4. FUNGUS RESISTANT
<br />5. BASE PRODUCT: TREMCO, TREMSIL 200; OR EQUAL
<br />g. JS-7: SILICONE SANITARY SEALANT
<br />1. ONE PART, NO BACTERIAL GROWTH
<br />2. ASTM C920, TYPE S, GRADE NS, CLASS 50
<br />3. NEUTRAL CURE
<br />4. COLOR: WHITE
<br />5. USDA APPROVED
<br />6. BASE PRODUCT: PECORA, 898; OR EQUAL
<br />h. JOINT CLEANER, PRIMER, BOND BREAKER
<br />1. AS RECOMMENDED BY SEALANT MANUFACTURER
<br />i. BACKER ROD
<br />1. POLYTHYLENE, POLYETHYLENE JACKETED POLYURETHANE FOAM, FLEXIBLE, NON-
<br />ABSORBENT, NON-BITUMINOUS MATERIAL RECOMMENDED BY SEALANT MANUFACTURER
<br />2. SCHEDULE
<br />a. INTERIOR JOINTS, UNPAINTED, LOCATED IN OR ADJACENT TO UNPAINTED MATERIALS OR SURFACES
<br />JS-1 OR JS-4
<br />b. INTERIOR CONTROL JOINTS IN UNPAINTED MASONRY AND GYPSUM BOARD -JS-1 OR JS-4
<br />c. EXTERIOR AND INTERIOR PAVING JOINTS -JS-2
<br />d. FLOOR JOINTS, CONTROL AND EXPANSION JOINTS -JS-2
<br />e. INTERIOR PAVING JOINTS, SLOPING -JS-3
<br />f. INTERIOR CONTROL JOINTS IN PAINTED (NON-EPOXY FINISHES) MASONRY AND GYPSUM BOARD -JS-5
<br />g. INTERIOR JOINTS -SANITARY; JOINTS IN CERAMIC TILE, AROUND TOILET ROOM VANITIES, PLUMBING
<br />FIXTURES, AND KITCHEN EQUIPMENT -JS-6 OR JS-7
<br />h. INTERIOR JOINTS -GMP BOUNDARY LINES AND SPACES WITHIN GMP LAB ZONES RECEIVING EPOXY
<br />FINISHES
<br />1. SEAL SPACES THAT WILL HARBOR VERMIN OR PROMOTE BACTERIAL GROWTH, PROVIDE
<br />FOR PRESSURIZATION, OR MAINTAIN ACOUSTIC SEPARATION
<br />2. APPLY SEALANT TO BOND TO EPOXY COATINGS. DO NOT BOND SEALANT TO SUBSTRATES
<br />SCHEDULED FOR EPOXY COATINGS
<br />3. SEAL CREVICES, SPACES, GAPS, AND OPENINGS, INCLUDING, BUT NOT LIMITED TO THE
<br />FOLLOWING:
<br />a. FIXTURES AND COVER PLATES
<br />b. JOINTS AROUND DOOR AND WINDOW FRAMES
<br />c. WALL / WALL JOINTS -DISSIMILAR MATERIALS
<br />d. WALL JOINTS
<br />e. WALL / DECK JOINTS WHERE WALLS EXTEND ABOVE CEILING TO STRUCTURE ABOVE
<br />f. WALL AND CEILING PENETRATIONS
<br />g. WALL CORNER GUARDS
<br />h. CEILING DIFFUSERS -HARD CEILINGS
<br />i. CEILING / LIGHT FIXTURES -HARD CEILINGS
<br />j. PERIMTER TRIM ANGLE FRO GASKETED CEILINGS
<br />k. DOOR KICK / ARMOR PLATES
<br />l. DOOR GLAZING STOPS
<br />m. CONTROL JOINTS
<br />n. CASEWORK
<br />I
<br />PROJECT NUMBER:
<br />jedson.com
<br />One Centennial Plaza
<br />705 Central Ave
<br />Cincinnati, OH 45202
<br />P: 513.965.5999
<br />F: 513.965.5998
<br />THIS DRAWING AND ITS RELATED COPYRIGHTS, INTELLECTUAL PROPERTY RIGHTS AND TRADE SECRETS ARE THE PROPERTY OF JEDSON
<br />ENGINEERING, INC. AND CONTAINS CONFIDENTIAL INFORMATION, WHICH SHALL NOT BE USED, COPIED OR DISCLOSED WITHOUT WRITTEN PERMISSION
<br />OF JEDSON ENGINEERING, INC. ©2013 JEDSON ENGINEERING, INC. ALL RIGHTS RESERVED.
<br />1
<br />2
<br />3
<br />4
<br />5
<br />6
<br />7
<br />8
<br />9
<br />1
<br />2
<br />3
<br />4
<br />5
<br />6
<br />7
<br />8
<br />9
<br />ABCDEFGHKLM
<br />REVISIONS
<br />ABCDEFGHJKLM
<br />PROJ. NO.:
<br />DRAWN BY:
<br />CHECKED BY:
<br />APPROVED BY:
<br />SCALE:11/4/2021 1:10:43 PMApprover
<br />Checker
<br />Designer
<br />200199
<br />McCORMICK & COMPANY
<br />ROOM FINISH SCHEDULESB-A501SB-A501 -I
<br />200199
<br />ROOM SCHEDULE
<br />ROOM NUMBER ROOM NAME FLOOR FINISH BASE FINISH WALL FINISH CEILING FINISH
<br />CEILING
<br />HEIGHT COMMENTS SCHEDULE
<br />139 EXISTING TANK FARM YES
<br />140 NEW TANK FARM URETHANE COATING URETHANE COATING URETHANE COATING NONE YES
<br />141 TANK FARM VEST. EPOXY COATING EPOXY COATING EPOXY PAINT NONE 0"YES
<br />142 NEW TANKER UNLOADING URETHANE COATING URETHANE COATING URETHANE COATING NONE YES
<br />143 ELECTRIC ROOM EPOXY COATING EPOXY COATING LATEX PAINT NONE 0"YES
<br />144 ANALYTICAL LAB EPOXY COATING 4" LIGHT DUTY EPOXY COVE EPOXY PAINT WASHABLE SUSP. ACOUST. TILE 9'-0"YES
<br />145 EX. MAINTENANCE ROOM EXISTING EXISTING EXISTING NONE YES
<br />146 MAINTENANCE SEALED CONCRETE NONE LATEX PAINT NONE YES
<br />147 CORRIDOR URETHANE COATING URETHANE COATING EPOXY PAINT WASHABLE SUSP. ACOUST. TILE 9'-0"YES
<br />148 MECHANICAL POLISHED CONCRETE NONE LATEX PAINT INSULATED METAL PANELS 20'-0"YES
<br />149 MAKING ACID BRICK ACID BRICK URETHANE COATING INSULATED METAL PANELS 20'-0" URETHANE COATING ON CONC. COLUMN BASES YES
<br />150 MILLING ACID BRICK ACID BRICK URETHANE COATING INSULATED METAL PANELS 20'-0"YES
<br />151 FILLING SUITE ACID BRICK ACID BRICK / URETHANE COATING STAINLESS STEEL INSULATED METAL PANELS INSULATED METAL PANELS 15'-0"YES
<br />152 TOILET RM VEST. EPOXY COATING EPOXY COATING INSULATED METAL WALL PANELS 9'-0"YES
<br />153 TOILET RM. EPOXY COATING EPOXY COATING INSULATED METAL WALL PANELS 9'-0"YES
<br />201 MECHANICAL ROOM MEZZANINE SEALED CONCRETE NONE NONE NONE YES
<br />3" = 1'-0"2 FINISH DETAILS
<br />6" = 1'-0"3 FLOOR COATING DETAILS
<br />3425 LATHROP ST. SOUTH BEND, INDIANA 46628
<br />NO DESCRIPTION DATE DB CB AB
<br />B LAYOUT D 7/13/2021 DLR DLR
<br />C LAYOUT E 8/3/2021 DLR DLR
<br />D LAYOUT PROGRESS 8/11/2021 DLR DLR
<br />E LAYOUT G 8/25/2021 DLR DLR
<br />F REVISIONS 9/14/2021 DLR DLR
<br />G GENERAL REVISIONS 9/20/2021 DLR DLR
<br />H GENERAL REVISIONS 10/1/2021 DLR DLR
<br />I ISSUED FOR REVIEW 11/01/2021 DLR DLR
|