Laserfiche WebLink
CONCRETE TILT-UP <br />WALL PANELS <br />CONCRETE DRIVE -SEE <br />CIVIL SITE PLANS <br />CONCRETE SLAB -SEE <br />STRUCTURAL DRAWINGS <br />WALKABLE INSULATED METAL <br />PANELS <br />STEEL BEAM <br />SEE STRUCTURAL DRAWINGS <br />STEEL JOISTS <br />SEE STRUCTURAL DRAWINGS <br />STEEL ROOF DECK <br />SEE STRUCTURAL DRAWINGS <br />MECHANICALLY FASTENED <br />MEMBRANE ROOF ON RIGID <br />INSULATION <br />PREFINISHED METAL <br />GUTTER <br />20'-0"WALKABLE CEILING <br />20'-4" <br />SB-A207 <br />1 <br />SB-A207 <br />2 <br />11 <br />MECHANICALLY FASTENED <br />MEMBRANE ROOF ON RIGID <br />INSULATIONPREFINISHED METAL <br />FASCIA TRIM <br />STEEL ROOF DECK <br />SEE STRUCTURAL <br />DRAWINGS <br />STEEL JOISTS <br />SEE STRUCTURAL <br />DRAWINGS <br />STEEL BEAM <br />SEE STRUCTURAL <br />DRAWINGS <br />WALKABLE INSULATED <br />METAL CEILING PANELS <br />STEEL BEAM <br />SEE STRUCTURAL <br />DRAWINGS <br />3 5/8" METAL STUDS AT <br />16" O.C. -RUN BETWEEN <br />WALL GIRTS <br />STEEL COLUMN <br />SEE STRUCTURAL <br />DRAWINGS <br />INSULATED METAL <br />WALL PANELS <br />MEMBRANE FLASHING <br />RUN UP BEHIND <br />WALL PANELS <br />BUILT-UP INSULATION <br />TO ACHIEVE POSITIVE <br />DRAINAGE <br />MECHANICALLY FASTENED <br />MEMBRANE ROOF ON RIGID <br />INSULATION <br />WALL GIRT -SEE STRUCTURAL <br />DRAWINGS <br />20'-0"5/8" EXTERIOR GYPSUM <br />WALL SHEATHING <br />CONCRETE SLAB <br />SEE STRUCTURAL <br />DRAWINGS <br />SB-A207 <br />3 <br />11 <br />OUTRIGGER -SEE <br />STRUCTURAL DRAWINGS <br />STEEL ANGLE -SEE <br />STRUCTURAL DRAWINGS <br />1'-2" <br />9 <br />STEEL COLUMN - <br />SEE STRUCTURAL <br />DRAWINGS <br />WALKABLE INSULATED <br />METAL CEILING PANELS <br />EXISTING PRECAST <br />WALL PANELS <br />WALL FINISH -SEE <br />FINISH SCHEDULE <br />CONCRETE SLAB -SEE <br />STRUCTURAL DRAWINGS <br />STEEL BEAM - <br />SEE STRUCTURAL <br />DRAWINGS <br />EXISTING ROOF TO <br />REMAIN <br />MEMBRANE FLASHING <br />TO EXISTING MEMBRANE <br />ROOF -PER ROOF <br />MANUFACTURER'S <br />RECOMMENDATIONS <br />INSULATED METAL WALL <br />PANELS -BEYOND <br />MECHANICALLY FASTENED <br />MEMBRANE ROOF ON RIGID <br />INSULATION <br />SB-A207 <br />4 <br />10 <br />15 <br />CONCRETE FOUNDATION <br />SEE STRUCTURAL DRAWINGS <br />12" SPLIT FACE CONCRETE <br />BLOCK -INSULATE ALL NON- <br />GROUTED CELLS <br />PRE-FINISHED METAL <br />GUTTER <br />MEMBRANE ROOF ON <br />6" RIGID INSULATION AND <br />METAL DECK <br />STEEL ROOF JOISTS <br />SEE STRUCTURAL <br />DRAWINGS <br />STEEL BEAM <br />SEE STRUCTURAL <br />DRAWINGS <br />STEEL COLUMN <br />SEE STRUCTURAL <br />DRAWINGS <br />BOND BEAM WITH <br />(2) #5's CONTINUOUS <br />CONCRETE PEDESTAL <br />SEE STRUCTURAL <br />DRAWINGS <br />CONCRETE PEDESTAL <br />SEE STRUCTURAL <br />DRAWINGS <br />SB-A207 <br />7 <br />1513 <br />MEMBRANE ROOF ON <br />6" RIGID INSULATION <br />AND METAL DECK <br />STEEL BEAM -SEE <br />STRUCTURAL DRAWINGS <br />STEEL COLUMN -SEE <br />STRUCTURAL DRAWINGS <br />STEEL JOIST -SEE <br />STRUCTURAL DRAWINGS <br />EXISTING SPLIT FACE <br />CONCRETE BLOCK <br />--- <br />-SEE DETAIL ON SHEET <br />A207 <br />13 <br />PROJECT NUMBER: <br />jedson.com <br />One Centennial Plaza <br />705 Central Ave <br />Cincinnati, OH 45202 <br />P: 513.965.5999 <br />F: 513.965.5998 <br />THIS DRAWING AND ITS RELATED COPYRIGHTS, INTELLECTUAL PROPERTY RIGHTS AND TRADE SECRETS ARE THE PROPERTY OF JEDSON <br />ENGINEERING, INC. AND CONTAINS CONFIDENTIAL INFORMATION, WHICH SHALL NOT BE USED, COPIED OR DISCLOSED WITHOUT WRITTEN PERMISSION <br />OF JEDSON ENGINEERING, INC. ©2013 JEDSON ENGINEERING, INC. ALL RIGHTS RESERVED. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />ABCDEFGHKLM <br />REVISIONS <br />ABCDEFGHJKLM <br />PROJ. NO.: <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />SCALE:11/4/2021 1:10:21 PMApprover <br />Checker <br />Designer <br />200199 <br />McCORMICK & COMPANY <br />WALL SECTIONSSB-A205SB-A205 -I <br />200199 <br />3425 LATHROP ST. SOUTH BEND, INDIANA 46628 <br />1/2" = 1'-0"1 SECTION THRU MAKING -1 <br />1/2" = 1'-0"2 SECTION THRU MAKING -2 <br />1/2" = 1'-0"3 SECTION THRU MAKING -3 <br />1/2" = 1'-0"4 TANK FARM SECTION -4 <br />1/2" = 1'-0"5 TANK FARM SECTION -5 <br />NO DESCRIPTION DATE DB CB AB <br />B LAYOUT D 7/13/2021 DLR DLR <br />C LAYOUT E 8/3/2021 DLR DLR <br />D LAYOUT PROGRESS 8/11/2021 DLR DLR <br />E LAYOUT G 8/25/2021 DLR DLR <br />F REVISIONS 9/14/2021 DLR DLR <br />G GENERAL REVISIONS 9/20/2021 DLR DLR <br />H GENERAL REVISIONS 10/1/2021 DLR DLR <br />I ISSUED FOR REVIEW 11/01/2021 DLR DLR