My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotes - Cleveland Well Nos. 2 & 3 Refurbishments Proj No. 118-021E - Peerless Midwest, Inc.
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2020
>
Opening of Quotes/Proposals
>
Opening of Quotes - Cleveland Well Nos. 2 & 3 Refurbishments Proj No. 118-021E - Peerless Midwest, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/24/2020 6:48:22 PM
Creation date
11/24/2020 6:47:22 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
11/24/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Version 4/2/2019 Page - 8 Public Works Quote <br />c.Allow three (3) hours of contact time. <br />d.Work five (5)-foot sections of the bottom ten (10) feet of the upper screen with double disk for <br />a minimum of one (1) hour per five-foot section. <br />e.Pump off solution and neutralize any remaining acid with sodium bicarbonate. <br />f.Contractor is responsible for measuring and documenting the pH during pump off and <br />neutralizing any acid in the discharge. <br />g.Inject 110 gallons of sodium hypochlorite, combined with 2,000 gallons of clear water into <br />well using a 1,000 gallon cleaning tank, equipped with a pump, to inject the solution under <br />pressure through the double disk agitator. <br />h.Leave the chlorine solution in the well for a minimum of 36 hours contact time <br />10.Day 10 – Off site, 36 hour (min) contact time <br />11.Day 11 – Cleaning Top 10 feet of Upper Screen <br />a.Pump off chlorine solution to waste, neutralizing any remaining chlorine. <br />b.Inject 330 gallons of inhibited and stabilized hydrochloric acid and 3,500 gallons of clear <br />water into the well using a 1,000 gallon cleaning tank to mix in equal portions per tank, <br />equipped with a pump, to inject the solution under pressure. Work this solution into the top <br />ten feet of screen with double disk. <br />c.Allow three (3) hours of contact time. <br />d.Work five (5)-foot sections of the top ten (10) feet of the upper screen with double disk for a <br />minimum of one (1) hour per five-foot section. <br />e.Pump off solution and neutralize any remaining acid with sodium bicarbonate. <br />f.Contractor is responsible for measuring and documenting the pH during pump off and <br />neutralizing any acid in the discharge. <br />g.Inject 110 gallons of sodium hypochlorite, combined with 2,000 gallons of clear water into <br />well using a 1,000 gallon cleaning tank, equipped with a pump, to inject the solution under <br />pressure through the double disk agitator. <br />h.Leave the chlorine solution in the well for a minimum of 36 hours contact time. <br />12.Day 12 –Off site, 36 hour (min) contact time <br />13.Day 13 - Pump off to waste for thirty minutes, remove double disk agitator and test pump. Tear <br />down and clean up. <br />14.Payment for all work included in well cleaning shall be made as a lump sum as specified in the <br />proposal as follows: <br />Well Cleaning and Re-development……………………LS <br />XX.POST CLEANING VIDEO INSPECTION OF CASING AND SCREEN <br />A. Prevailing Specifications: None <br />B. Additions: <br />1.The complete well including casing and screen shall be video inspected with a color borehole <br />camera. <br />2.The well cannot be video inspected until a minimum of 24 hours after the test pump is pulled to <br />allow for debris to settle, allowing a clear view of the well. <br />3.It is the contractor’s responsibility to clear the well prior to the video if applicable. <br />4.Camera shall have sufficient lighting on board to show in plain view details within 16” well casing. <br />5.An archive copy of the video shall be provided to the customers on DVD with the pump inspection <br />report as well as a written summary of the inspection. <br />6.Borehole camera must have both down looking and side view/rotational capabilities. <br />7.Camera must have on screen display of depths overlaid directly to the video. <br />8.Submerged tape measures are not acceptable for documenting depth. <br />9.Black and white video, indirect mirror imaging, and low resolution cameras are not acceptable. <br />10.Payment for all work included in Post Cleaning Video Inspection of Casing and Screen shall be <br />made as a lump sum as specified in the proposal as follows: <br />Post Cleaning Video Inspection of Casing and Screen……………………LS
The URL can be used to link to this page
Your browser does not support the video tag.