My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Bids - One (1) or More, 2020 or Newer, Emergency Medical Vehicle – Spec P - Horton Emergency Vehicles
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2020
>
Opening of Bids
>
Opening of Bids - One (1) or More, 2020 or Newer, Emergency Medical Vehicle – Spec P - Horton Emergency Vehicles
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2025 1:53:45 PM
Creation date
11/12/2020 11:18:50 AM
Metadata
Fields
Template:
Board of Public Works
Document Type
Contracts
Document Date
11/10/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
of one (1) "D" size oxygen bottle. Cast brackets will be used to house customer's <br />bottle. <br />22.8 ADDITIONAL OXYGEN BOTTLE STORAGE <br />A double oxygen bottle storage system shall be provided and installed against the <br />front wall of the D1 compartment. It shall provide vertical storage of two (2) "D" size <br />oxygen bottles. Cast brackets will be used to house customer's bottles. <br />Y N <br />Y N <br />22.8.1 A single oxygen bottle storage system shall be provided and installed against <br />the front wall of the D1 compartment. It shall provide vertical storage of one (1) "D" <br />size oxygen bottle. Cast brackets will be used to house customer's bottles. <br />Y�C N <br />22.9 SQUAD BENCH CABINET <br />A cabinet shall be located over the squad bench at the ceiling level, rearward of the <br />entry/egress door opening. This cabinet shall be divided into three (3) separate <br />sections. The cabinet shall be finished in the same material as the rest of the interior <br />cabinets. This cabinet shall be compliant with the KKK 1822 revision F specification. <br />YK N <br />22.9.1 There shall be three (3) 3/8" flip -up Plexiglas doors. <br />Y4",N <br />22.9.2 A stainless Steel Round Southco latch (or equal) shall be provided on each <br />door. <br />Y N <br />23.0 IV HOLDERS <br />Four [4] ceiling mounted Cast Products 2008-1 recessed IV holders shall be <br />supplied. These shall be located at the head and foot areas, two [2] over the squad <br />bench and two [2] over the primary cot. They shall have a rubber, foldaway storage <br />when not in use. Each holder must have the capacity to hold two [2] bottles and <br />have Velcro securing straps. <br />Y)�N <br />23.1 COT MOUNT <br />A Stryker Power Load cot mount shall be supplied. It must accommodate the Stryker <br />Power Pro XT. y <br />Y /� N <br />The cot mount shall be located in the center of the patient compartment. <br />YXN <br />23.2 ASSIST RAILS <br />One [1] 90" long, 1.50" diameter, smooth satin finished overhead grab rail shall be <br />provided and securely fastened to the ceiling over the primary cot. One [1] 60" long, <br />1.50" diameter, smooth satin finished overhead grab rail shall be provided and <br />securely fastened over the squad bench. The grab rails shall be fastened with bolts, <br />washers and nuts of the appropriate dimension, through the interior ceiling panel and <br />through the .090" aluminum accessory plate welded into the roof structure. Assist <br />rails fastened with self -tapping machine screws are not acceptable. These grab rails <br />must meet or exceed AMD Standard 008, Load Test for Ambulance Patient <br />Compartment Grab Rail. <br />Y N <br />
The URL can be used to link to this page
Your browser does not support the video tag.