Laserfiche WebLink
City of South Bend Central Services Division <br />Fire Service, Inc./Wheeled Coach Ambulance <br />Specification <br />heavy duty coiled cord will be supplied and it shall be hard wired in the cab area <br />and accessible to the driver and passenger. <br />ADDITONAL COMPARTMENT LIGHTS <br />An additional compartment light shall be installed as noted within the build <br />stripper . <br />TIMER <br />An Intermatic 15 minute Timer shall be installed <br />ELECTRICAL TROUBLESHOOTING LIGHT <br />A small light with a switch shall be installed in the circuit board area for <br />troubleshooting. The light shall be wired battery hot. <br />SUCTION PUMP <br />A suction pump shall be installed that shall comply with Federal Specifications <br />KKK-A-1822-F. <br />ACOUSTIC AND CLIMATE INSULATION <br />The primary manufacturer shall supply an insulating material that is non <br />flammable with a Class A, Class 1 fire rating. It shall be certified to meet the <br />smoke and flammability requirements of FMVSS 302. The exposed walls of the <br />exterior compartments and wheel wells that intrude into the interior of the <br />modular shall be covered with reflective insulating material with a value of R-14. <br />The side, front, rear, walls as well as the ceiling shall be insulated with a one inch <br />block foam beneath a full covering of reflective insulation. In addition, spray <br />foam insulation shall be installed under the aluminum floor moisture barrier and <br />between the floor structures. <br />10070-0003 11 /05/20 <br />44 <br />