Laserfiche WebLink
City of South Bend Central Services Division <br />Fire Service, Inc./Wheeled Coach Ambulance <br />Specification <br />doors shall then be installed on the painted module jamb. A Corrosion inhibitor <br />shall be applied to both the door frame and jamb side of the hinge leafs. <br />Additional corrosion inhibitor to be applied in all screw holes in both door frame <br />and j amb. <br />EXTERIOR COMPARTMENTS <br />The right side of the bottom of compartments shall be flush with the door opening <br />to provide for a sweep out design making it easier and safer to change the oxygen <br />bottle. <br />COMPARTMENT A <br />Compartment A is the passenger side forward compartment. There will only be <br />inside access to the RFC. <br />COMPARTMENT B2 <br />Compartment B2 is the passenger side rear compartment. The door opening <br />dimensions shall be a minimum of 80.75 inches high and 22 inches wide. The <br />interior dimensions shall be approximately 86.5 inches high and 25.5 inches wide <br />and 21.5 inches deep. <br />COMPARTMENT D <br />Compartment D is the drivers side rear compartment. The door opening <br />dimensions shall be a minimum of 62 inches high and 32 inches wide. The <br />interior dimensions shall be approximately 62 inches high and 32.25 inches wide <br />and 19.75 inches deep. Compartment will have double doors. <br />COMPARTMENT E <br />Compartment E is on the drivers side just forward of the rear wheel. The door <br />opening dimensions shall be a minimum of 46 inches high and 42.5 inches wide. <br />10070-0003 11 /05/20 <br />19 <br />