Laserfiche WebLink
2021 International MV/PL Custom Titan 170 <br />Type I Ambulance Proposal Specification <br /> <br /> <br />A5347-0002 11/05/20 <br />45 <br /> <br />DOME LIGHTS WITH DOOR OPEN: <br /> <br />The dome lights mounted in the ceiling of the vehicle shall be activated to the low intensity position when the personnel <br />entrance doors are open. The circuit shall be relay controlled and the dome light current shall n ot be controlled by the <br />door post switch. <br /> <br />EXTERIOR COMPARTMENT LED STRIP LIGHTING: <br /> <br />All exterior compartments shall be provided with LED adhesive backed strip lights. Each compartment shall have the <br />lights installed on both the left and right vertical side of the compartment. Lights shall be mounted on angled brackets for <br />maximum illumination into the compartment. The compartment lights shall be controlled by an automatic door post switch <br />in each door. The compartment open indication light shall activate anytime any compartment door is opened. The door <br />post switch shall activate the compartment lighting relays. The door post switch shall not carry the current of the <br />compartment lights. <br /> <br /> <br />SEPARATE SWITCHES FOR OXYGEN COMPARTMENT <br />LIGHT <br /> <br />There shall be a separate, individual control switch in the vehicle to independently control the light within the oxygen <br />compartment. The switch shall be located in the Rear Main Switch Panel. <br /> <br />LSS LED PANEL LIGHT: <br /> <br />An indirect light located above the Life Support Station counter shall be used to illuminate the action area. The light shall <br />be a Heavy Duty LED panel light and be switched by a switch on the side of the light as well as from the rear main switch <br />panel. <br /> <br />SEPARATE SWITCH FOR PANEL LIGHT (LSS AREA) <br /> <br />There shall be a separate, individual control switch in the vehicle to independently control the Panel Light in the LSS area. <br />The switch shall be located in the Rear Main Switch Panel. <br /> <br />12 VOLT TECNIQ LED PATINET PROCEDURE LIGHTS: <br /> <br />The ceiling of the ambulance shall be equipped with two (2) TecNiq 42 LED light fixtures, mounted in the ceiling wire <br />raceway. The lights shall be located directly over the center position of the stretcher. The lights shall be controlled by a <br />separate relay controlled circuit and switch in the rear switch panel. <br /> <br />STEPWELL LIGHT: <br /> <br />An independent, recessed LED step well light shall be provided in the rear side of the diamond plate step well and be <br />automatically activated whenever the side entrance do or is open. The exterior shall be protected from weather and <br />damage. All connections shall be weatherproof, sealed connectors. <br /> <br />12 VOLT TECNIQ LED LIGHTS: <br /> <br />Four (4) 17", 42 LED fixtures shall be installed and equally spaced in between the (6) dome lights. The fixtures shall have <br />reinforced housings with a plastic diffuser which locks in place. The lights shall be relay controlled and switched by a