Laserfiche WebLink
of one (1) "D" s ize oxygen bottle. Cast brackets will be used to house customer's <br />bott le . / <br />YLN_ <br />22.8 ADDITIONAL OXYGEN BOTTLE STORAGE <br />A double oxygen bottle storage system shall be provided and installed against the <br />front wall of the 01 compartment. It shall provide vertical storage of two (2) "D" size <br />oxygen bottles. Cast brackets will be used to house customer's bottles. / <br />y N~ <br />22.8.1 A single oxygen bottle storage system shall be provided and installed against - <br />the front wall of the 01 compartment. It shall provide vertical storage of one (1) "D" <br />s ize oxygen bott le. Cast brackets will be used to house customer's bottles . <br />22.9 SQUAD BENCH CABINET <br />A cabinet shall be located over the squad bench at the ceiling level, rearward of the <br />entry/egress door opening. This cabinet shall be divided into three (3) separate <br />sections. The cabinet shall be finished in the same material as the rest of the interior <br />cabinets. This cabinet shall be compliant with the KKK 1822 revis ion F specification. <br />22.9.1 There shall be three (3) 3/8" flip-up Plexiglas doors. <br />22.9.2 A stainless Steel Round Southco latch (or equal) shall be provided on each <br />door. <br />23.0 IV HOLDERS <br />Y_. N/ <br />Y_NL <br />Y_N / <br />Four [4] ceiling mounted Cast Products 2008-1 recessed IV holders shall be <br />s upplied. These shall b e located at the head and foot areas, two [2] over the squad <br />bench and two [2] over the primary cot. They s hall have a rubber, foldaway storage <br />when not i n use. Each ho lder must have the capacity to hold two [2] bottles and <br />have Velcro securing straps. / <br />Y_LN __ <br />23.1 COT MOUNT <br />A Stryker Power Load cot mount shall be supplied. It must accommodate the Stryker <br />Power Pro XT. / <br />Y_L.N._ <br />The cot mount shall be located in the center of the patient compartment. y~- <br />23.2 ASSIST RAILS <br />One (11 90" long, 1.5011 diameter, smooth satin finished overhead grab rail shall be <br />provided and securely fastened to the ceiling over the primary cot. One [1] 60" long, <br />1.50" diameter, smooth satin finished overhead grab rail shall be provided and <br />securely fastened over the squad bench. The grab rails shall be fastened with bolts, <br />washers and nuts of the appropriate dimension, through the interior ceiling panel and <br />through t he .090n alum inum accessory plate welded into the roof structure. Assist <br />rails fastened with se lf-tappi ng machine screws are not accepta ble . These grab ra ils <br />must meet or exceed AMO Standard 008, Load Test for Ambulance Patient <br />Compartment Grab Rall. / <br />Y_(_ NN_