Laserfiche WebLink
South Bend Fire Department <br />The compartment shall be equipped with the following: <br />One (1)Vents, Compts, Louvers,Includes Filters(Ea) <br />44-40-1100 <br />One (1) louver with filter shall be installed in the compartment. <br />One (1)Shelving Tracks, (2) Unistrut, Alum <br />45-01-1050 <br />ADJUSTABLE SHELVING TRACKS <br />The compartments shallbe equipped with two (2) aluminum adjustable tracks, vertically <br />mounted, that are boltedin place foradjustable shelving and equipment mounting. <br />One (1)Shelf, Adjust, Alum 3/16" <br />45-02-3100 <br />ADJUSTABLE SHELF <br />One (1)adjustable shelf shall be constructed of .188” smooth aluminum plate with 1.5” formed <br />vertical lip front & back.Shelf supports on each side to be constructed of .188” aluminum and <br />bolted to an aluminum extrusion (mounted vertically) by use of 3/8” bolts and spring-loaded cam <br />locks. If shelf is longer than 40” a reinforcementby aluminum gusset is tobe placedfull-length <br />on bottom of shelf. <br />One (1)Turtle Tile, Shelves/Trays, (each) <br />45-30-1300 <br />The shelf/tray shall befitted with removable vinyl Turtle Tile matting. The matting shall be <br />interlocking modules approximately 12" square by 9/16" thick. This material shall be resistant to <br />heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant. <br />One (1)Turtle Tile, Compartment Floor <br />45-30-1400 <br />The floor areaof the compartment shall be fitted with removable vinyl Turtle Tile matting. The <br />matting shall be interlocking modules approximately 12" square by 9/16" thick. This material <br />shall be resistant to heat,cold, ultra-violet radiation, mechanical impacts, chemical actions and is <br />corrosion resistant. <br />One (1)Cmpt Lt, Wall, ROM,V3LED Track Lt, (2) Ea Cmpt <br />55-01-1250 <br />COMPARTMENT LIGHTS <br />Two (2) ROM verticallymounted roll-up compartment LED V3 door lights shall be installed one <br />eachsideofthedooropening.Thecompartmentlightsshallbeintegratedintotheroll-updoor <br />tracks with the light actuation with the door opening. <br />The lights shall have a polycarbonatelens to eliminate breakagefrom impact and eliminate heat <br />buildup. <br />One (1)Cmpt Lt, Dr Swtch, Magnetic,Ea <br />55-06-1400 <br />The compartment light will be controlled by a magnetic "On-Off" switch located on each <br />compartment door. <br />10040-001909/02/20 <br />78 <br />PDF created with pdfFactory Pro trial version www.pdffactory.com <br /> <br />