Laserfiche WebLink
South Bend Fire Department <br />Two (2) Cap, 2-1/2", NSTChrome, Rocker Lug, w/Chain <br />24-03-1400 <br />Two (2) 2-1/2" NST rocker lug chrome plated vented capand cable or chain securement shall be <br />provided. <br />Two (2) VlvMfger,AKR,8000, (2-1/2") <br />24-61-1250 <br />The specified valve shallbe an Akron 8000 Seriestwo and one half-inch (2-1/2") valve with a <br />stainless ball. <br />Two (2) Sealed LeverBanks - Cable Cntrls, AKR (EACH) <br />26-17-1050 <br />Thevalvecontrolshallbeasealedleverbanktypewithaircraftcablecontrol.Theleverbanks <br />shall be locking with a polished finish. They shall have a 6” stroke for ease of operation. <br />Theaircraftcablethatisusedtocontrolthevalvefromtheleverbankshallbefurnishedwith7/8” <br />bulkhead both ends, 5/16” threaded ends and will also require a 5/16” swivel u-joint that unhooks <br />from the ball valve. Thiscable will be usedforease of maintenance and operation. <br />Theleverbankbellcranksshallbeenclosedinanaluminumboxthatisattachedbelowthepump <br />operator’scontrol panel. <br />The aluminum box shall be weatherresistant so that dust is not allowed to enter the operatorarea <br />through the pump control panel. <br />Two (2) Gauge, Dschg, IC,2-1/2"400#, WF <br />27-02-1500 <br />Two (2) 2-1/2"IC discharge pressure gauges (0-400 PSI) shall be provided. The face of the <br />gauge shall be aWHITEdial with black letters. The gauges will be located on the pump <br />instrument panel. <br />One (1)Dschg, 2-1/2", Rr CenterPumpPanel,Left Center,NST <br />23-20-2200 <br />REAR CENTER PUMP PANEL LEFT CENTER -- 2-1/2" DISCHARGE <br />One (1) 2-1/2" dischargeshall be installed to the left of center on the rearcenter pump panel and <br />shall be controlled by a quarter turn ball valve on the rear mount pump control panel. The <br />discharge shall have 2-1/2" NPT x 2-1/2" NST male hose threads. An engraved nameplate label <br />shall be installed adjacent the valve control handle. <br />One (1)Drain/Bleeder,IC Lift-Up, Mnl 1/4 Turn <br />21-01-2500 <br />AnInnovativeControls¾”castbronzequarter-turndrain/bleedervalveshallbeinstalled.The <br />valveshallbecompletewithachromeplatedbronzeball,reinforcedteflonseals,andblow-out <br />proofstemratedto600PSI.Achromeplatedzinchandleshallbeprovidedoneachdrainvalve <br />completewitharecessedIDlabelprovision.Thehandleshalllift,toopenandpushdown,to <br />close. <br />One (1)Elbow, 2-1/2"Fx 2-1/2" NST M,Chrome <br />24-02-1200 <br />One (1)chrome platedelbow with rocker lugs shall be provided with 2-1/2" NST swivel female <br />x 2-1/2" NST male hose threads. <br />10040-001909/02/20 <br />50 <br />PDF created with pdfFactory Pro trial version www.pdffactory.com <br /> <br />