Laserfiche WebLink
South Bend Fire Department <br />One (1)Electrical JctBox,Weather Resistant <br />50-05-1510 <br />WEATHER RESISTANT ELECTRICAL JUNCTION BOX <br />The electrical junction or terminal boxes shall beweatherresistant and located away from water <br />spray conditions.In addition, the main body junction panel shall house theautomatic reset <br />breakers and relays where required. The main body junction panel shall be located in the pump <br />compartment. <br />One (1)SwtchPanel,Dash,ChassisSupplied <br />50-12-1090 <br />DASH MOUNTED EMERGENCY ELECTRICAL SWITCH PANEL <br />An electrical switch panel shall be designed and mounted in the cab dasharea as furnished with <br />the chassis. All switches shall be provided with backlighted snap-in legend inserts. <br />SWITCHES <br />All emergency light switches shall be lighted, rocker style. Switches shallbe internally lit when <br />the switch circuit is in the on position. A plug-in identification label is to be provided and <br />installed adjacent to each rocker switch with backlighting provided behind the label. <br />An internally lighted switch shall be provided and wired through a heavy-duty relay to activate <br />power to the emergency lights. The emergency lights shall be activated bya single "MASTER <br />SWITCH" on theelectrical console. <br />One (1)Air Horns, (2) Rcsd, RHBumper,24.5" Stuttertone,Chrome <br />50-41-5000 <br />AIR HORNS <br />Two (2) 24.5" Stuttertone chrome plated air horns shall be recess mountedinto the front bumper <br />on the right side. An airprotection valve shall beprovided in the air horn piping that will not <br />allow the chassis air brake system to drop below 90 PSI. <br />One (1)Air Horn Cntrl, Dual Lanyard Pull Cord <br />50-43-2500 <br />AIR HORN LANYARD <br />One (1) dual roof mounted pull cord shall be installed to activate the air horn system. The pull <br />cord shall be installed within easy reach of the driver and officer. <br />One (1)Lt, Pump Cmpt, 12 Volt LEDWith Swtch <br />51-05-6400 <br />PUMP ENCLOSURE LIGHTS <br />One (1) LED work lightshall be provided in the pump enclosure. <br />One (1)Switch on Light Head <br />51-05-9000 <br />The control switch shallbe mounted on the light head. <br />10040-001909/02/20 <br />26 <br />PDF created with pdfFactory Pro trial version www.pdffactory.com <br /> <br />