My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotes - Olive Street Station Roof Repairs Proj No. 120-028 - Midland Engineering Company, Inc.
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2020
>
Opening of Quotes/Proposals
>
Opening of Quotes - Olive Street Station Roof Repairs Proj No. 120-028 - Midland Engineering Company, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/26/2020 8:48:51 AM
Creation date
8/26/2020 8:48:21 AM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
8/25/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
B. Identify plywood as to species, grade, and glue type by the stamp of the APA <br />Engineered Wood Association. <br /> <br />C. Identify other materials of this Section by the appropriate stamp of the agency <br />approved in advance by the Architect/Engineer. <br /> <br />2.2 MATERIALS <br /> <br />A. Provide materials in the quantities needed for the Work shown on the Drawings, <br />and meeting or exceeding the following standards of quality: <br />1. Structural lumber, including all floor joists, ceiling joists and beams, and <br />exterior entrance platforms: Southern Pine, No. 1, Kiln Dried. <br />2. Non Structural Horizontal framing members: Douglas Fir-Hemlock, Table <br />1, Construction grade. <br />3. Non Structural Vertical framing members: Douglas Fir-Hemlock, Table 1, <br />Standard grade. <br />4. Sheathing: <br />a. <br />Exposure 1. <br />5. Wood preservative: Ammoniacal copper arsenite, or 5% solution of <br />pentachlorophenol. <br />6. Rough hardware: <br />a. Steel items: <br />(1) Comply with ASTM A36. <br />(2) Use galvanized at exterior locations. <br />b. Machine bolts: Comply with ASTM A307. <br />c. Lag bolts: Comply with Fed Spec FF-B-561. <br />d. Nails: <br />(1) Use common except as otherwise noted. <br />(2) Comply with Fed Spec FF-N-1. <br />(3) Use galvanized at exterior locations. <br />e. Powder-actuated Fasteners: <br />1. Comply with ASTM B633, SCI, Type III <br />2. As manufactured by Hilti fastening systems or equal as <br />approved by the Architect/Engineer. <br />f. Expansion Anchors: <br />1. Use wedge type anchors with a single three section wedge <br />2. Comply with Federal Specifications A.A 1923A, Type 4. <br />g. Joist hangers and Metal Straps & Brackets: Simpson, Teco, or <br />equal as approved by the Architect/Engineer. <br /> <br />2.3 OTHER MATERIALS <br /> <br />A. Provide other materials, not specifically described but required for a complete <br />and proper installation, as selected by the Contractor subject to the approval of <br />the Architect/Engineer. <br /> <br />PART 3 - EXECUTION <br /> <br />3.1 SURFACE CONDITIONS <br /> <br />CARPENTRY <br />06100-2 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.