Laserfiche WebLink
to the apparatus. <br />- Two (2) salvage covers each a minimum size of 12 ft x 14 ft (3.7 in x 4.3 m). <br />- One (1) traffic vest for each seating position, each vest to comply with ANSUISEA 207, <br />Standard for High Visibility Public Safety Vests and have a five -point breakaway feature that <br />includes two at the shoulders, two at the sides, and one at the front. <br />- Five (5) fluorescent orange traffic cones not less than 28" (711 mm) in height, each <br />equipped with a 6" (152 mm) retro-reflective white band no more than 4" (152 mm) from the <br />top of the cone, and an additional 4" (102 mm) retro-reflective white band 2" (51 mm) belom <br />the 6" (152 mm) band. <br />- Five (5) illuminated warning devices such as highway flares, unless the five (5) fluorescent <br />orange traffic cones have illuminating capabilities. <br />- One automatic external defibrillator (AED). <br />- If the supply hose carried does not use sexless couplings, an additional double female <br />adapter and double male adapter, sized to fit the supply hose carried, shall be carried <br />mounted in brackets fastened to the apparatus. <br />- If none of the pump intakes are valved, a hose appliance that is equipped with one or more <br />gated intakes with female swivel connection(s) compatible with the supply hose used on one <br />side and a swivel connection with pump intake threads on the other side shall be carried. Any <br />intake connection larger than 3 in. (75 mm) shall include a pressure relief device that meets <br />the requirements of 16.6.6. <br />- If the apparatus does not have a 2V2' National Hose (NH) intake, an adapter from 2'V2" NH <br />female to a pump intake shall be carried, mounted in a bracket fastened to the apparatus if <br />not already mounted directly to the intake. <br />- If the supply hose carried has other than 2V2' National Hose (NH) threads, adapters shall be <br />carried to allow feeding the supply hose from a 2 %2" NH thread male discharge and to allow <br />the hose to connect to a 2Y2" NH female intake, mounted in brackets fastened to the <br />apparatus if not already mounted directly to the discharge or intake. <br />)OFT SUCTION HOSE, PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2009 edition, section 5.7.2 requires a minimum of 20 ft of suction hose or 15 ft <br />of supply hose. <br />Hose is not on the apparatus as manufactured. The fire department shall provide suction or <br />supply hose. <br />DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2009 edition, section 5.8.3 requires one (1) approved dry chemical portable fire <br />extinguisher with a minimum 80 B:C rating mounted in a bracket fastened to the apparatus. <br />The extinguisher is not on the apparatus as manufactured The fire department shall provide <br />and mount the extinguisher. <br />WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2009 edition, section 5.8.3 requires one (1) 2.5 gallon or larger water <br />extinguisher mounted in a bracket fastened to the apparatus. <br />The extinguisher is not on the apparatus as manufactured The fire department shall provide <br />73 <br />