Laserfiche WebLink
1.3 REFERENCES <br />Specifier Notes: List standards referenced in this section, complete with designations and titles. This <br />article does not require compliance with standards, but is merely a listing of those used. <br />A. American Architectural Manufacturers Association (AAMA): <br />1. AAMA 303 - Voluntary Specification for Poly (Vinyl Chloride) (PVC) Exterior Profile <br />Extrusions; American Architectural Manufacturers Association. <br />2. AAMA 502 — Voluntary Specification for Field Testing of Windows and Sliding Doors. <br />B. ASTM International: <br />1. ASTM C 1036 — Flat Glass. <br />2. ASTM C 1048 — Heat -Treated Flat Glass --Kind HS, Kind FT Coated and Uncoated Glass. <br />3. ASTM D 1929 — Standard Test Method for Determining Ignition Temperature of Plastics. <br />4. ASTM D 3656 — Insect Screening and Louver Cloth Woven from Vinyl -Coated Glass <br />Yarns. <br />5. ASTM E 283 — Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors <br />Under Specified Pressure Difference Across the Specimen. <br />6. ASTM E 547 — Water Penetration of Exterior Windows, Curtain Walls and Doors by Cyclic <br />Static Air Pressure Differential. <br />C. Screen Manufacturers Association (SMA): <br />1. SMA 1201 — Specifications for Insect Screens for Windows, Sliding Doors and Swinging <br />Doors. <br />D. Window and Door Manufacturers Association (WDMA): <br />1. ANSI/AAMA/NWWDA 101/I.S.2 — Voluntary Specifications for Aluminum, Vinyl (PVC) and <br />Wood Windows and Glass Doors. <br />1.4 PERFORMANCE REQUIREMENTS <br />Specifier Notes: Performance ratings for "ThermaStar by Pella" vinyl sliding windows vary by product <br />and size. Current performance information is found in the "ThermaStar by Pella" Architectural Design <br />Manual at www.pellaadm.com on the Design Data pages of each product section. Consult your local <br />Pella representative for more information. <br />A. Windows shall meet Rating HS -R -PG[ ] specifications in accordance with <br />ANSI/AAMA/NWWDA 101/I.S.2/A440-08 or ANSI/AAMA/NWWDA 101/I.S.2/A440-11. <br />B. Window Air Leakage, ASTM E 283: Window air leakage when tested at 1.57 psf (25 mph) shall <br />be 0.18 cfm/ft2 of frame or less. <br />C. Window Water Penetration, ASTM E 547: No water penetration through window when tested <br />under static pressure of [4.5 psf (42 mph)] [5.25 psf (45 mph)] after 4 cycles of 5 minutes each, <br />with water being applied at a rate of 5 gallons per hour per square foot. <br />1.5 SUBMITTALS <br />ThermaStar by Pella® Vinyl Sliding Windows (East) <br />08562 (08 53 13) - 2 <br />