siding has been installed in order to prevent increased deterioration of the structure from moisture and/or insects. Mortar joints <br />should be repointed only when there is evidence of moisture problems or when sufficient mortar is missing to allow water to <br />stand in the mortar joint. Existing mortar shall be duplicated in composition, color, texture, joint size, method of application and <br />joint profile. It is emphasized that, prior to initiating any restoration or rehabilitation effort, the property owner should contact the <br />Historic Preservation Commission of South Bend and St. Joseph County which is located in the County/City Building of South <br />Bend. The Commission is an invaluable source of information about all facets of rehabilitation and restoration. <br />Prohibited Wood siding shall not be resurfaced with new material which is inappropriate or was unavailable when the building <br />was constructed, such as artificial stone, brick veneer, asbestos or asphalt shingles. Sandblasting or the use of harsh detergents <br />shall not be used on masonry including brick, stucco, limestone, flagstone and sandstone. This method of cleaning erodes the <br />surface material and accelerates deterioration. Brick surfaces shall not be painted unless they had been painted originally. <br />Repointing shall not be done with a mortar of high Portland cement content which can often create a bond that is stronger than <br />the building material. This can cause deterioration as a result of the differing coefficient of expansion and the differing porosity <br />of the material and the mortar, which can result in serious damage to adjacent brick. Paint shall not be removed from masonry <br />surfaces indiscriminately. <br />STAFF RECOMMENDATION: Staff recommends approval of the removal of the original aluminum siding and the residing <br />with the LP Smart Siding. <br />Catherine D. Hostetler, <br />Director <br />On a motion by Mike Voll with a second by Tom Gordon to approve application as presented. <br />Vote: 6 — 0 unanimous. <br />COA#2015-0702 Approved. <br />2. 341 West North Shore COA#2015-0706B West North Shore <br />No representation <br />STAFF REPORT <br />CONCERNING APPLICATION FOR A <br />CERTIFICATE OF APPROPRIATENESS <br />Date: 7 July 2015 <br />Application Number: 2015-0706B <br />Property Location: 341 West North Shore Drive <br />Architectural Style/Date/ Traditional Ranch/1949 <br />Property Owner: Patty and Dennis Gafvert <br />Landmark or District Designation: West North Shore LHD <br />Rating: Notable <br />DESCRIPTION OF STRUCTURE/ SITE: The McLean House was built in 1949 and replaced a house that was demolished in <br />1939. The ranch house is one storey on a "rectangular plan with appendages". The exterior walls are random ashlar limestone. <br />The roofline is a low hip with slate shingles. The entrance has a low shed roof. The windows are non-operable, fixed vertical <br />divided light. <br />ALTERATIONS: The windows are not original to the house as the survey card notes 10 pane casement windows. There are no <br />COAs in this file. <br />APPLICATION ITEMS: See attached description and drawings. <br />Front Porch Roof. A new Hip Roof is proposed to replace an existing shed roof over the present entrance. The existing Shed <br />Roof is not consistent with this period style California Ranch. The shed roof entry is very low and unusual in that the rest of the <br />house is a hip style roof. The concrete stoop, limestone pier and metal railing will remain. A small amount of matching <br />additional stone will be installed on top of the stone pier at the west side to support the roof. The steel column at the east side <br />would be replaced with a taller steel column as needed. The roof material is slate and will be salvaged as part of the proposed <br />new roof. Additional matching slate of similar specifications (size and color) will be installed to complete the new entry roof. A <br />new full light entrance door is proposed to replace the raised panel door. Window Replacement: The existing non -original <br />fixed sash windows are a replacement of the original operable casement windows. The proposed plans show new operable <br />casement windows as per the proposed south elevation view. These will be custom fit to the existing masonry openings. This <br />house was classified as "insignificant' in the survey of the historic district. A specification of the proposed windows is attached. <br />New Garage: The North elevation view shows a proposed 2 stall garage off of the alley to the north of the existing garage. The <br />existing attached garage will be converted to a master suite. The proposed garage roof will be a hip roof of similar slope to the <br />existing in asphalt shingle. The overhang and fascia will be similar to the existing house in dimension and scale. The proposed <br />siding will be painted horizontal cement fiber board with a 7" reveal, of compatible color to the existing limestone. North <br />Entrance: A small entrance is proposed off of the north patio. The roof is proposed as a hip roof compatible with the existing <br />house. <br />DESCRIPTION OF PROPOSED PROJECT: Kil Architecture is proposing to re -configure the front porch entrance from a <br />low shed roof to a taller hip roof. The new porch will use the same materials original to the house. The raised panel door will be <br />replaced with a full light entrance door. The current fixed non-operable windows will be replaced with single light operable <br />casements custom fabricated to fit the original openings. The new garage will be situated at the rear of the house off of the alley. <br />It will have a hip roof covered in asphalt shingles that will compliment the slate roof of the house as well as the cement board <br />