My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
December 2014
sbend
>
Public
>
Historic Preservation
>
Meeting Minutes and Recordings
>
HPC Meeting Minutes 2014
>
December 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2019 1:16:20 PM
Creation date
6/8/2020 10:16:23 AM
Metadata
Fields
Template:
South Bend HPC
HPC Document Type
Minutes
BOLT Control Number
1001363
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
The height of a new structure and its height to width proportions shall be consistent with adjacent buildings in the district. The <br />building height shall be no greater that that of the tallest existing structure and no less than that of the lowest existing structure in <br />the same block. Facade proportions shall be established by permitting no structure with a facade wider or narrower than those <br />existing in the same block. Additions to existing buildings shall be related in height and proportion to the existing structure. <br />Recommended <br />Contemporary designs should be compatible in character and mood to the building or neighborhood. <br />Prohibited <br />Additions may not be constructed that would change the existing facade of a building, alter its scale or architectural character, or <br />add new height. <br />Not Recommended <br />New stories should not be added, nor should existing stories be removed, which would destroy important architectural details, <br />features or spaces of the building. Any style or period of architecture that is incompatible with what exists should not be <br />permitted in the new additions. <br />B. BUILDING MATERIALS IN NEW CONSTRUCTION <br />Wall materials in the district range from brick, clapboard, shingles and masonry to aluminum siding. <br />Required <br />Exterior materials used on a new structure shall be compatible in type, scale, texture, and color with adjacent structures. Materials <br />used on an addition to an existing structure shall relate to the existing or original materials of that structure. As much of the <br />original structure as possible shall be retained so that the addition could be removed without damage to the basic structure and <br />appearance of the building. <br />Recommended <br />Aluminum or vinyl siding may be used when it is the only feasible alternative. This siding should be compatible in size and style <br />and with the materials of other buildings in the district. <br />Prohibited <br />Inappropriate materials such as asbestos, asphalt, cast stone, or artificial brick may not be used. <br />Not Recommended <br />Glass blocks should not be used. Concrete block should not be used for anything other than foundations <br />STAFF RECOMMENDATION: Staff recommends approval as the project conforms to the guidelines for Edgewater Place. <br />Catherine D. Hostetler, Director <br />On a motion by Tom Gordon with a second by Kevin Buccellato to conditionally approve based <br />on enclosing the rafter tails with inspection by Preservation Specialist. <br />Vote: 6 —1. <br />Lynn Patrick — Reason: The design didn't come before the commission until after installation and <br />because Commissioner Patrick, as a resident of this neighborhood, is familiar with this project <br />and the manner in which it was pursued. <br />COA#2014-1125 Approved Conditionally. <br />2. 1049 Riverside Drive COA#2014-1125A Riverside Drive <br />Representation by Ann Price, owner <br />STAFF REPORT <br />CONCERNING APPLICATION FOR A <br />CERTIFICATE OF APPROPRIATENESS <br />Date: December 2, 2014 <br />Application Number: 2014-1125A <br />Property Location: 1049 Riverside Drive <br />Architectural Style/Date/Architect or Builder: Gable FronU1909/Huffman House <br />Property Owner: Ann Graham Price <br />Landmark or District Designation: Riverside Drive LHD <br />Rating: Contributing <br />DESCRIPTION OF STRUCTURE/ SITE: A 2 `/2 storey rectangular plan house set upon a concrete block foundation. Roof is <br />asphalt shingle. Walls are a combination of wide and narrow clapboard and wood shingles. There is a full width front porch, <br />screened in. Windows are 1/1 wood double hung with storms. <br />ALTERATIONS: Non -original addition in rear with rubber membrane roof. <br />APPLICATION ITEMS: Install 6" gutters to replace obsolete half -round style (no available contractors for in-kind <br />replacement). <br />DESCRIPTION OF PROPOSED PROJECT: Owner has applied to install a common 6" K -style aluminum seamless gutter <br />system throughout the house to replace deteriorated half -round. Owner has contacted multiple contractors requesting to replace <br />the half -round gutters in-kind, to no avail. <br />STANDARDS AND GUIDELINES: <br />II. EXISTING STRUCTURES <br />B. ROOFS ANDROOFING <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.