My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
September 2003
sbend
>
Public
>
Historic Preservation
>
Meeting Minutes
>
HPC Meeting Minutes 2003
>
September 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2019 1:16:16 PM
Creation date
6/8/2020 10:11:17 AM
Metadata
Fields
Template:
South Bend HPC
HPC Document Type
Minutes
BOLT Control Number
1001360
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SEP -09-2003 10:27 WCS INDIANA OFFICE 5742877711 P.12/20 <br />)IVISION 8- QOORS & WRUP_QWj <br />SECTION 08550- WOOD WINDOWS <br />PART 1 - GENERAL <br />1.1 RELATED DOCUMENTS <br />A. Drawings and general provisions of the Contract, including General and Supplementary <br />Conditions and Division 1 Specification Sections, apply to this Section. <br />1.2 SUMMARY <br />A. This Section includes the following aluminum -clad wood -framed window product types: <br />1. Awning windows. <br />2. Casement windows. <br />3. Double -hung windows. <br />4. Fixed windows. <br />5. Decorative non-operative fixed windows. <br />1.3 DEFINITIONS <br />A. C: Commercial. <br />B. Performance grade number, included as part of the AAMA/NWWDA product designation <br />code, is actual design pressure in pounds force per square foot (pascals) used to determine <br />structural test pressure and water test pressure. <br />C. Structural test pressure, for uniform load structural test, is equivalent to 150 percent of <br />design pressure. <br />D. Minimum test size is smallest size permitted for performance class (gateway test size). <br />Products must be tested at minimum test size or at a size larger than minimum test size to <br />comply with requirements for performance class. <br />1.4 PERFORMANCE REQUIREMENTS <br />A. General: Provide wood windows capable of complying with performance requirements <br />indicated, based on testing manufacturer's windows that are representative of those <br />specified and that are of test size indicated below: <br />1. Minimum size required byAAMA/NWWDA 101 /1,S.2. <br />2. Minimum size required by gateway performance requirements for determining <br />compliance with AAMA/NWWDA 101/I.S.2 for both gateway performance <br />requirements and optional performance grades. <br />3. Size indicated. <br />B. AAMA/NWWDA Performance Requirements: Provide wood windows of the performance <br />class and grade indicated that comply with AAMA/NWWDA 101 /I.S.2. <br />1. Performance Class: C. <br />South Bend Community School Corp. 09550-1 07-4965-01 <br />Plan Z and CPF Projects Bid Group 14 <br />Jefferson Intermediate Center Window Replacement <br />
The URL can be used to link to this page
Your browser does not support the video tag.