Laserfiche WebLink
Public Parks <br /> ADA Barrier Priorites <br /> Facility 1.Accessible 2.Access to Goods and 3.Usability of Rest Rooms 4.Additional Access <br /> Approach/Entrance Services <br /> Ramps on lower level Assessor indicated plants No ADA Barrier Present No ADA Barrier Present <br /> potentially noncompliant:their needed to be trimmed back <br /> ratio is 1:8.It is,however,right from the walkways,and that fire <br /> on the line and the steepest alarms&emergency systems <br /> slope allowed under the law. needed to be made compliant <br /> The one at the entrance is also (i.e.the type of alarms with <br /> problematic because it covers flashing strobes).Assessor <br /> more than 30 inches of rise, indicated restroom signage was <br /> which requires a landing to be too glossy(this can be <br /> Potawatomi added.One parking space problematic for the visually <br /> Conservatory must additionally be designated impaired).Replace with <br /> 2105 Mishawaka Ave. as van-accessible(w/8'access something closer to a matte or <br /> aisles),and have signage eggshell finish.Other than <br /> indicating it as such. finish,signs compliant. <br /> Additionally,interior doors are <br /> too heavy.Lighter doors must <br /> be installed(or,alternatively,be <br /> made automatic or power- <br /> assisted). <br /> Railings need to be installed The tables protrude too much Need to add accessible Need to provide cup dispensers <br /> and ramps must have non-slip into public areas.Signs need to signage,placed to the side of for fountains with spouts that <br /> surface material put down.The be provided that have raised the door,60"to centerline.For are too high.Need to place a <br /> only accessible entrance is a letters,Grade II Braille,and that doorways and passages,if cane-detectable barrier on each <br /> service enterance.There are meet all other requirements for symbols are used,add side of water fountains at floor <br /> no signs indicating an permanent room or space supplementary verbal signage level. <br /> accessible entrance because signage.Legibility requirements with raised characters and <br /> there is no accessible entrance. for signs need to be reviewed braille below pictogram symbol. <br /> The threshold to the entrance is and signs should be replaced Need to replace stall door <br /> too high so a short ramp should as needed to meet the handles with lever or loop <br /> ® Potawatomi be put in. requirments for character size, handles. <br /> contrast,and finish.The tops of <br /> 2000 wall St.Pool <br /> the tables or counters are too <br /> high and should be lowered or <br /> auxiliary tables/counters should <br /> by provided.The counter and <br /> surrounding furnishings should <br /> be rearranged to create space <br /> to pass items.A call button <br /> needs to be provided. <br /> It would appear that there are Any directional or informational Signage should be posted No ADA Barrier Present <br /> spaces in the zoo which are sign on the interior of a building indicating where accessible <br /> open to the public but which should provide Braille,unless restrooms are.Other than that. <br /> lack suitable ramps. that sign is mounted up high restrooms compliant <br /> Unfortunately,there aren't any (greater than 80").If mounted <br /> measurements provided.The lower.and if the sign <br /> ADA mandates that any area designates a permanent area <br /> open to the public should have (say,a gift shop)the sign <br /> barriers removed to the should have Braille,raised <br /> maximum extent feasible;it lettering,or pictograms to aid <br /> ® Potawatomi Zoo may be helpful to trace a route the visually impaired.A sign <br /> 500 S.Greenlawn Ave. from the disabled spaces in the like that should be mounted <br /> parking lot,making a note to with its centerline 60"from the <br /> add ramps wherever the path ground,and on the latch side of <br /> crosses curbs or steps.• an entrance.Counters where <br /> cashiers are present,or where <br /> food is sold should be 36"from <br /> the ground or lower.If that is <br /> not feasible,a lowered section <br /> or portion would be helpful. <br /> Attachment 3-10 <br />