Laserfiche WebLink
Public Parks <br /> ADA Barrier Priorites <br /> 1Facility Accessible 2.Access to Goods and 3.Usability of Rest Rooms 4.Additional Access <br /> Approach/Entrance Services <br /> Parking spaces earmarked for Space between wall and desk Restrooms require signage and No ADA Barrier Present <br /> the disabled need to be not compliant;need at least lighter or powered doors. <br /> reconfigured such that they are 36".Doorway into south room Otherwise 100%compliant. <br /> situated as close as practicable requires widening to at least <br /> to accessible entrances.They 32".Restroom doors too heavy, <br /> must be painted appropriately, cannot require more than 5 lbf <br /> and display code-compliant to open.Fire alarms must be <br /> signage.One space for every flashing kind.Any permanent <br /> © eight(8)disabled spots must directional signage must be <br /> Howard Park Senior be van accessible,with brought up to code.Kitchen <br /> Center appropriate stripes and counter seemingly too high <br /> 604 E.Jefferson Blvd. signage.Signs should be (unless there is a lower <br /> placed that direct people auxiliary section available). <br /> toward accessible entrances as <br /> well.Entrance itself needs to be <br /> widened(32'minimum)and <br /> the door is too heavy.Install <br /> lighter door or add power <br /> assistance. <br /> Not all objects protruding into Not applicable Pictograms and symbols are Not applicable <br /> the circulation paths can be either not used to identify rest <br /> detected by a person with a rooms or,if they are used,there <br /> visual disability using a cane. are no raised characters or <br /> O Kennedy Park Baseballiamond parking There are nospots accavailable.essible braille included below them. <br /> There is not a wheelchair- <br /> 2700 Westmoor St. accessible stall.There are no <br /> grab bars.The distance from <br /> the floor to the bottom of the <br /> lavatory apron is too small. <br /> IMPORTANT!Since this Fire alarms must be the sort No ADA Barrier Present No ADA Barrier Present <br /> assessment was done,the law that flash when activated. <br /> has been updated,and Signage mounted a little too <br /> swimming pools now have their high and not up to code(Braille, <br /> ® Kennedy Park Pool own standards for compliance. raised lettering,etc.) <br /> 2700 Westmoor St. This was not an issue when the <br /> assessment was originally <br /> taken,but data should be <br /> gathered and adjustments <br /> made. <br /> Doors to entrance could not be All doors inside the building There are no signs to indicate No ADA Barrier Present <br /> opened with a closed fist cannot be opened with a closed where the accessible restroom <br /> fist is at inaccesible restroom. <br /> OCharles Black Signs mounted at accesible <br /> Recreation Center restroom does not have <br /> 3419 W.Washington St. pictorgrams or braille to <br /> indicate restroom.There is 28 <br /> inches from the ground to the <br /> bottom of lavatory apron. <br /> Sidewalk needed paving as of Interior doors inoperable to Restrooms need compliant No ADA Barrier Present <br /> assessment(parking lot some individuals with mobility signage.Not quite enough <br /> entrance).Green trash cans impairments(they should be room for wheelchair access <br /> placed in such a way as to able to be opened with a closed (needs to be 36'path to all <br /> obstruct entrance.Not enough fist).Obstacles along routes not fixtures),perhaps move privacy <br /> space on latch side of exterior detectable to individuals using wall toward lockers if <br /> door;requires powered and/or a cane(specifically the water possible/not unduly expensive. <br /> O Leeper Park Tennis automatic door opener. fountain,see§IV).Fire alarms Stall doors must be operable, <br /> Courts must flash when activated. inside&out,with a closed fist. <br /> 907 Riverside Dr. Directional signs too high Mirror mounted too high <br /> (should be 60'from centerline (should have lower edge under <br /> to floor),and not up to code 40"). <br /> (braille,raised lettering,etc.). <br /> No data present for controls <br /> (light switches,cabinets,etc.), <br /> these should be at an <br /> accessible height. <br /> Attachment 3-9 <br />