Laserfiche WebLink
10083-0016 <br />CITY OF SOUTH BEND <br />components. The locks shall be a KeyOne Plus lock cylinder with a reversible <br />key. The KeyOne Plus system allows the lock core to be removed with a special <br />key and allows it to be rekeyed for additional security and keying fleets the same, <br />The rear trailing door shall have a patented side release paddle handle that <br />removes the necessity of reaching inside the patient compartment door. The door <br />entry system shall have been tested to 100,000 cycles. <br />The locking system shall be from the locking handle by aluminum push rods. The <br />patient compartment doors will be equipped with an inside door lock. All entry <br />doors shall have horizontal aluminum reinforcements welded to the door frame <br />and the entry doors shall have closed cell block foam insulation. <br />Handle, Module Compt, Trimark, Black/Chrome, STD <br />COMPARTMENT DOOR LATCHES, HINGES AND HARDWARE <br />When the doors are opened, the hinges, latches and door checks shall not protrude <br />into the patient compartment. All compartment doors shall employ the same type <br />of locking hardware. All door latches shall comply with FMVSS 206. The locking <br />devices shall be two stage rotary latches and shall be in accordance with FMVSS. <br />There shall be two door latches, one at the top and one at the bottom, controlled <br />by a single locking handles. The latches shall look into an adjustable Nader type <br />pin located in the door frame. The Nader will utilize a captive nut to provide <br />adjustment and replacement without loss of the nut plate. <br />The compartment door handles shall be Trimark OEM style handle with a large <br />enough space for gloved hands to operate the handle. The door handles shall be <br />free floating with 1008 cold rolled steel mechanical components with Nitrotee <br />treated wear components. The locks shall be a KeyOne Plus lock cylinder with a <br />reversible key. The KeyOne Plus system allows the lock core to be removed with <br />a special key and allows it to be rekeyed for additional security and keying fleets <br />the same. The compartment door entry system shall have been tested to 50,000 <br />cycles. The door handle shall be mounted to the exterior door panel using <br />mechanical fasteners and rubber gaskets that will eliminate the possibility of <br />electrolysis. All doors shall have closed cell block foam insulation. <br />ELECTRIC DOOR LOCK PACKAdE OPTIONS: Click to add <br />Door Locks,Electric, Trimark. (1)DOOR,--Entry Doo <br />POWER DOOR LOCKS <br />The module entry doors shall include power door locks that enable remote <br />activation. <br />08127/18 <br />19 <br />