South Bend Redevelopment Commission <br />Ignition Park ACM Demolition Proposal — Batch 2 <br />9/23/2011 Page 3 <br />ADDITIONAL CHARGES <br />Commercial Buildings (2) $ 200.00 <br />Category I Flooring on concrete: 2 @ $60.00 120.00 <br />TOTAL PROJECT FEE — 9 Structures $2,930.00 <br />The quoted fee for Labor is a fixed amount based on 9 structures, independent of the number of <br />suspect asbestos - containing materials encountered and samples. The number of structures takes into <br />account any multiple structures at combined addresses, except as noted for warehouses. This fee will <br />not be exceeded without prior written justification and approval. <br />Analyses of samples for suspect asbestos - containing materials (ACM) will be invoiced at the stated <br />unit costs. The number of suspect asbestos containing materials (ACM) per structure based on our <br />previous experience with structures of similar size, age and construction is expected to average 6 by <br />PLM per structure. This includes brittle, potentially friable Category II suspect materials. We intend <br />to assume that Category I non - friable materials (resilient flooring, flooring adhesive, asphalt roofing, <br />gaskets) are ACM and do not anticipate the need to sample these at this time. These can remain with <br />the structures for demolition. Older linoleum consisting of two separable layers will be considered <br />Category II potentially friable and sampled if encountered. The only Category I material that will be <br />sampled is resilient flooring attached to concrete, to allow the concrete to be recycled. The actual <br />number of samples needed will be determined in the field. It is not expected to vary greatly from the <br />number quoted. The Commission will be billed for the actual number of samples collected. <br />BASIS OF PROPOSAL <br />The above pricing is based on the following assumptions: <br />• Commission to provide ready access to each structure <br />• Commission to assure that each structure is unoccupied <br />Ready access includes keys or the typical chipboard or plywood sheeting over doors fastened with <br />hex head or #2 square drive multipurpose screws. Locked doors either alone or underneath this <br />sheeting are not considered "ready access ". <br />IDEM allows the demolition of residences with non - friable Category I and II materials in place, <br />except when intentionally burned. We propose to assume such materials to be ACM and document <br />them as such, including their quantities, on the IDEM Notification and in our survey reports. <br />Although it rarely occurs, severely water - damaged resilient flooring, normally a Category I non - <br />friable material even for demolition, may be encountered and need to be classified as potentially <br />friable for demolition. A confirming analysis for this type of material will be needed and is done by <br />TEM. TEM analysis for Category I flooring on concrete is included in this pricing, but if potentially <br />friable Category I flooring is encountered the need for this additional analysis will be brought to the <br />Commission's attention for action. <br />TIME OF COMPLETION <br />• from receipt of the formal Notice -to- Proceed to completion of the field survey -- 1 week <br />