Laserfiche WebLink
Representation by Derek Wright,Access Properties, 623 East LaSalle Avenue <br /> STAFF REPORT <br /> CONCERNING APPLICATION FOR A <br /> CERTIFICATE OF APPROPRIATENESS <br /> Date: June 5,2017 <br /> Application Number: 2017-0605 <br /> Property Location: 821 Ashland <br /> Architectural Style/Date/Architect or Builder: American Foursquare/1901 <br /> Property Owner: Robert&Carlotta Levy <br /> Landmark or District Designation: Chapin Park Local/National Historic District,ordinance#9574-05 <br /> Rating: Contributing <br /> DESCRIPTION OF STRUCTURE/SITE:This 2-story wood frame house with square plan sits upon a brick foundation. The <br /> hip roof has asphalt shingles,and a brick chimney offset from the peak with three simple corbel courses. The house front <br /> features a full height bay with windows. Windows are wood 1/1 wood double hung with diamond pattern muntins on front <br /> far,ade. A hipped roof garage is at the rear of property. <br /> ALTERATIONS:House has had aluminum siding,storm windows and doors added. In 1949 the front porch was removed and <br /> a front stoop was added,with a small plastic porch roof over the entrance. <br /> APPLICATION ITEMS:Demo garage structure,haul away debris. Pad will remain,possibly for extra parking since very <br /> limited street parking. South Bend Code Enforcement affirmed demo.(Stan Molenda) <br /> DESCRIPTION OF PROPOSED PROJECT:Owner proposes to tear down garage. Building is composed of several garage <br /> structures/additions,some block,some frame,in varying conditions,all of which are to be demolished. The 1932 Portage <br /> Township Assessor's card lists a 2-car(19x19)block garage noted in 1949 as being used as a shop,as well as a 1 car(24x 12) <br /> wood garage. There is also a note from 1955 listing a 23.5x24 concrete slab car port. Demolition order on garage was affirmed <br /> at June 18,2015 Code Enforcement meeting. Debris will be hauled away,but concrete pad will be retained to provide extra <br /> parking. <br /> PRESERVATION SPECIALIST REPORT: <br /> June 9,2017 <br /> I had received a call from Derek of Access Properties giving me permission to enter the building last evening.I went first thing <br /> this morning and was able to take interior photographs.There are multiple sections to the structure.There is an apartment in there <br /> as well.The roof has collapsed in the"breezeway"between the apartment and garage.The roof of the garage itself has two areas <br /> that have holes and deterioration.The pads of the garages are in fine condition and could be reused even for just parking.The <br /> additions are really where the deterioration is the worst.The makeshift walls are rotted through and the exterior walls are a <br /> combination of block and doors.The two strongest walls are those that run north and south and are part of the original garage <br /> structure,but the removal of the rear wall and all the additional weight of the newer walls on the original has begun to pull the <br /> structure apart.The argument could be made to save the original small garage structure;however,the roof and framework of that <br /> roof would still have to be removed and rebuilt as well as the rear wall rebuilt.It may be more effective to tear down and rebuild <br /> a solid larger structure that utilizes the entire pad area.The main house is currently used as multi-unit apartments(4,I believe by <br /> the number of mail boxes) <br /> Steve Szaday,Preservation Specialist <br /> STANDARDS AND GUIDELINES: <br /> CHAPIN PARK LOCAL HISTORIC DISTRICT <br /> V.GENERAL <br /> A.Buildings in the district should not be demolished except where a building poses a threat to <br /> the public safety,and demolition is the only alternative.Documentation of interior and exterior <br /> features of the original buildings,especially homes rated as historically significant,is <br /> encouraged.Measured drawings and photographs may be submitted to-the Historic <br /> Preservation Commission for safekeeping and future reference. <br /> STAFF RECOMMENDATION:While evidence from the Assessor's card shows several of the garages have been on the <br /> property for some time,the current arrangement of connected garage structures does not contribute to the historic character of the <br /> property. Demolition has been affirmed by South Bend Code Enforcement. Due to significant deterioration of the later additions <br /> and compromised integrity of the altered original garage,staff recommends demolition of the entire garage,and retention of the <br /> concrete pad,and would further recommend owner propose a new garage design to be built in the future. <br /> Elicia Feasel,Executive Director <br /> Deb Parcell,Deputy Director <br /> Commissioner Gordon moved to approve application as submitted. Seconded by Commissioner <br /> Anderson. Six in favor,none opposed. <br /> Vote: 6—0 <br /> COA#2017-0605 Approved. <br /> 16 <br />