Laserfiche WebLink
Valen Light eSI-IINr Solar L€:D Lighting Systems <br />Batteries- Batteries need to have the following characteristics <br />1JA Batteries must have a high temperature electrolyte capable of -39 to i-69 degrees Celsius <br />1.1.2 Autonomy for discharge regulated to 20% of the total battery capacity after 1 night <br />operation <br />1.1.3 Utilize 4 Batteries wired in Series / Parallel <br />14.4 Batteries are to be stored inside the pole <br />1A.5 Batteries must have stainless steel terminals <br />1.1.6 Batteries must be GEL type with high temperature electrolyte <br />1.1.7 Batteries must be considered NON -Dangerous goods, non -spillable and meet air shipment <br />safety standards, <br />1.1.8 High current recharge 0.8°C - 1.0"C <br />1.1.9 High current discharge battery that can be discharged at 30'C within 8 seconds with no <br />damage to the battery <br />1.1.10 Self Discharge Residual Capacity is more than 90%after 90 days 77"F (25°C) <br />1.1.11 No acid mist emission when charging or discharging <br />1.1.12 Batteries mast have a 5 year, full warranty, Prorated warranties will not be acceptable, <br />Electronics- System electronics need to have the following characteristics <br />2.1.1 3 x 2 pole DC Double pole Circuit breakers <br />2.1.2 Pre. Configured Quick Connect terminal strip for LAMP, SOLAR and BATTERIES <br />2.1.3 LED Drivers located In the control board and not the LED lamp <br />2.1.4 All battery series and parallel wiring is to be terminated into the terminal block with type <br />bridges to form the series / parallel connections <br />2.1.5 Integrated 2-year data logger provides insight into the system operation, status, voltage, and <br />current. <br />2.1.6 Deep discharge protection. <br />2.1.7 Ambient Temperature of -40C to -t60C <br />2,1.8 Integrated temperature sensing. <br />2.1.9 Field adjustable operation profile. <br />2.1.10 Provisions must be made for control box to be slip -mounted inside pole above top battery, <br />with enclosure opening directly accessible through access hatch. <br />2.1.11 Intelligent environmental adaptive energy preservation <br />Pale- The solar pole needs to have the following characteristics <br />3.1.1 Hot dipped Galvanized steel <br />3.1.2 Multi -Section Pole with Integrative 360 Degree swivel Panel Bracketing <br />3.1.3 Pole load rating Is to suit a minimum of 80 MPH wind speeds <br />3.1.4 Base section to Include vandal lockable control access hatch <br />3.1.5 Pole bottom section to include internal stackable mounting shelf <br />3.1.6 Bottom Integrative enclosure section minimum 7.87" to maximum 11.8r' width. <br />3.1.7 Bottom Integrative enclosure section minimum 74.80" height. <br />3AA Anchor Bolt must be high tensile steel M30 type bolts with Min. Yield Strength (Ksi) = 640 MPa <br />(93Ksi); Min. Tensile Strength (Ksi) = 800 MPa (1161(sij <br />3.1.9 Pole bottom section Integrative battery enclosure structure to house batteries & electronics. <br />11.10 Access hatch must be sized to accommodate battery Installation and removal. <br />