HomeMy WebLinkAboutEncroachment & Revocable Permit - 1044 E Angela Blvd - O'Rourke's Public House November 24, 2026 Tony Halsey KRG Eddy Street Commons LLC thalsey@kiterealty.com RE: Encroachment into Public Right-of-Way – 1044 E. Angela Blvd., Suite 103 Dear Tony: At its November 24, 2026 meeting, the Board of Public Works approved your request to install a pergola structure at 1044 E. Angela Blvd., Suite 103. The encroachment approval is subject to the following condition: • The structure must successfully pass inspection and receive approval from the Building Department. Additionally, the improvements must not create or contribute to a safety hazard. The Board also offers the following recommendation: • The structure should be designed to allow for easier deconstruction and removal, if necessary, while maintaining safe conditions and ensuring that the improvements do not create or contribute to a safety hazard. The encroachment will be permitted to remain and continue until such time as the Board of Public Works of the City of South Bend shall determine that such encroachment is in any way impairing or interfering with the highway or with the free and safe flow of traffic thereon. Said encroachment shall not in any way prejudice or preclude the City’s rights with respect to the future use of that portion of the right-of-way. If, at any time, the City of South Bend determines that it is necessary to revoke the encroachment permit, you, or the future property owner will be responsible for any and all costs associated with the removal of the encroachment and returning your property to its pre-existing state. Sincerely, /s/Hillary Horvath Hillary Horvath, Clerk INTEROFFICE MEMORANDUM BOARD OF PUBLIC WORKS DATE: TO: October 9, 2026 Kyle Ludlow, Engineering Department Derek Erquhart, Fire Department Chris Dressel, Community Investment FROM: Hillary Horvath, Clerk; PWengineering@southbendin.gov SUBJECT: ENCROACHMENT RECOMMENDATION Revocable Encroachment – KRG Eddy Street Commons LLC LOCATION: 1044 E Angela Blvd., Suite 103 PLEASE INSERT YOUR RECOMMENDATIONS IN THE APPROPRIATE FIELD BELOW, BASED ON THE FOLLOWING CRITERIA: 1. It has been determined that this encroachment in no way impairs the highway or with the free and safe flow of traffic thereon, and it is recommended that the encroachment be permitted to remain. 2. Said encroachment shall not in any way prejudice or preclude the City’s rights with respect to the future use of the portion of the right-of-way. ENGINEERING: Favorable Recommendation; would advise that structure be designed to be more easily deconstructable (Recommendation provided after consulting with Streets Department – Coby Deal) COMMUNITY INVESTMENT: Favorable recommendation (recognizing the revocable condition of a granted request) FIRE: Favorable Recommendation (must pass inspection from the Building Department) DATE: ALLIANCE ARCHITECTSALL RIGHTS RESERVEDSHEET NO.2026cO'ROURKE'S PATIO ENCLOSURE KITE Realty Group 1044 E. Angela Blvd., Suite 103 South Bend, IN 4661710/7/26G1.0INDEX OF DRAWINGS OWNERARCHITECTALLIANCE ARCHITECTS929 LINCOLNWAY EAST, SUITE 200SOUTH BEND, IN 46601(574) 288-2052O'ROURKE'S PATIO ENCLOSUREKITE Realty GroupG1.0COVER SHEET; INDEX OF DRAWINGS; CODE ANALYSISC1-100SITE LAYOUT OVERALL PLAN; PLANTER SECTIONS1PERGOLA FOUNDATION & ROOF FRAMING PLANSS2FOUNDATION DETAILSS3STRUCTURAL CONNECTION DETAILS; GENERAL NOTESE0.1ELECTRICAL LEGEND, NOTES, SCHEDULESE0.2ELECTRICAL SPECIFICATIONSE1.1ELECTRICAL PLAN1044 E. ANGELA BLVD., SUITE 103SOUTH BEND, INDIANA 46617KRG EDDY STREET COMMONS, LLC30 S. MERIDIAN STREETINDIANAPOLIS, IN 46204(317) 577-5600CIVIL ENGINEERTHE TROYER GROUP, INC.550 UNION STREETMISHAWAKA, IN 46544(574) 259-9976STRUCTURAL ENGINEERSILVER CREEK ENGINEERING, INC.7225 WOODLAND DRIVE, SUITE 200INDIANAPOLIS, IN 46278(317) 297-5610ELECTRICAL ENGINEERALLIANCE ARCHITECTS929 LINCOLNWAY EAST, SUITE 200SOUTH BEND, IN 46601(574) 288-2052GENERAL CONTRACTORTHE SMART PERGOLA12958 BRIGHTON AVE.CARMEL, IN 46032(317) 682-4072BUILDING CODE ANALYSISAPPLICABLE CODES675 IAC 12-4-12EXISTING BUILDINGS; ADDITIONS OR ALTERATIONS675 IAC 13-2.6-12INDIANA BUILDING CODE, 2014 EDITION (IBC, 2012 EDITION, WITH INDIANA AMENDMENTS), CHAPTER 11: ANSI A117.1 – 2009675 IAC 16.4 INDIANA PLUMBING CODE, 2012 EDITION (IPC 2006, WITH INDIANA AMENDMENTS)675 IAC 17-1.8 INDIANA ELECTRICAL CODE 2009 EDITION (NFPA 70-2008, WITH INDIANA AMENDMENTS)675 IAC 18-1.6 INDIANA MECHANICAL CODE 2014 EDITION (IMC 2012, WITH INDIANA AMENDMENTS)675 IAC 19-4 EDITION INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1, 2007, WITH INDIANAAMENDMENTS)675 IAC 22-2.5 INDIANA FIRE CODE, 2014 EDITION (IFC 2012 EDITION, WITH INDIANA AMENDMENTS)ADA 2010 AMERICANS WITH DISABILITIES ACT STANDARDS FOR ACCESSIBLE DESIGN,AS PUBLISHED BY THE US DEPARTMENT OF JUSTICE (SEPT. 15, 2010)ALTERATION TO EXISTING BUILDINGSADDITIONS OR ALTERATION MAY BE MADE WITHOUT REQUIRING THE ENTIRE EXISTING BUILDING,STRUCTURE, OR SYSTEM TO COMPLY WITH ALL THE REQUIREMENTS OF THE RULES OF THECOMMISSION PROVIDED:THE CONSTRUCTION WORK WITHIN THE SCOPE OF ALTERATIONS SHALL CONFORM TO THEREQUIREMENTS FOR NEW CONSTRUCTION.THE ALTERATION SHALL NOT CAUSE THE EXISTING ELEMENT TO BECOME NONCOMPLIANTWITH EITHER THE REQUIREMENTS FOR NEW CONSTRUCTION OR WITH THE APPLICABLERULES OF THE COMMISSION OR ITS PREDECESSOR AGENCIES IN EFFECT AT THE TIME THEORIGINAL CONSTRUCTION OR INSTALLATION WAS MADE.INDIANA BUILDING CODE (IBC 2012)SECTION 304 EXISTING OCCUPANCY CLASSIFICATIONASSEMBLY GROUP A-2: RESTAURANT/BARSECTION 602 CONSTRUCTION CLASSIFICATIONEXISTING CONSTRUCTION, TYPE IIIB CONSTRUCTION.SECTION 704 EXTERIOR WALLSCOVERED UNDER PREVIOUS SHELL APPROVAL BY OTHERS.SECTION 705 FIRE WALLSCOVERED UNDER PREVIOUS SHELL APPROVAL BY OTHERS.SECTION 903 AUTOMATIC SPRINKLER SYSTEM; AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE PROVIDED IN ACCORDANCE W/ 903.3.1.1 (EXISTING).OCCUPANCY GROUP A: REQUIRED, PROVIDED.SECTION 907 FIRE ALARM907.2.1 GROUP A: MANUAL FIRE ALARM SYSTEM MINIMUM (EXISTING).SECTION 1004 OCCUPANT LOADTABLE 1004.1.1 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANTEXISTING:BAR AREAS147 S.F. / 5 = 30 OCCUPANTS351 S.F. / 5 = 70 OCCUPANTSDINING ROOMS 1698 S.F. / 15 = 111 OCCUPANTS185 S.F. / 15 = 12 OCCUPANTS377 S.F. / 15 = 25 OCCUPANTSKITCHEN 1451 S.F. / 200 = 7 OCCUPANTSOFFICE 59 S.F. / 100 = 1 OCCUPANTADDED:EXTERIOR DINING446 S.F. / 15 = 30 OCCUPANTS286 TOTAL OCCUPANTSQ:\Alliance Projects\Kite\O'Rourkes Patio\Drawings\AutoCAD\G1.0 COVER SHEET.dwg, 10/7/2026 4:30:23 PM, DWG To PDF Alliance - High Res.pc3 G G G G G G G G G G G E E E E E E E E E EE E E E E E E E E ST ST ST ST ST ST ST ST ST STSTE E E E E E E E E E E E ST ST (Asph) (Asph) (Sdwk) (Sdwk)(Sdwk) (Grass)(Grass) (Bench)(Bench)(Brk) (Brk) (Brk) (Bldg)(Bldg) (Bldg) (Conc)(Conc)(Conc) (Conc) (Conc)9'-7"51'-6"8'-2"5'-10"6'-8"11'-1"38'-1"6'-10"6'-10"12'-5"6'-0" (Conc)5'-0"4'-0"5'-0"7'-0"1'-4"1'-4"4'-1"6'-10"5'-8"10'-10"3'-0"5'-0"4'-4"8'-2"1'-4"10" 1'-4" 6'-8"1'-0"VariesNew Concrete Wall and Footing; See Structural Plan Compacted Aggregate (Min. 6") Concrete Sidewalk Aluminum Column; Refer to Architectural Plans for Additional Details Downspout Pipe Through Aluminum Column; Provide Opening in Wall for Outlet to Planter Planting Soil, 12" Depth Moisture Barrier Free Draining Fill Material Filter Fabric4"Provide 4" Weep Hole; Refer to Plan for Location NORTHNORTH C1-100 Site Layout Overall Plan #### 1" = 5' BWC MWRSite Improvements ForClient Name:O'ROURKE'S PUBLIC HOUSE1044 E ANGELA BLVDSOUTH BEND, IN 46617SHEET MARKDATEISSUED FORDRAWN BY:CHECKED BY: SCALE: SHEET TITLE PROJECT NUMBER troyergroup.com troyergroup.comALL IDEAS, DESIGNS, AND PLANS INDICATED OR REPRESENTED BY THE DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF THE TROYER GROUPAND ARE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE SPECIFIC PROJECT. NONE OF THE IDEAS, DESIGNS, OR PLANS SHALL BEUSED BY OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WITHOUT THE WRITTEN PERMISSION OF THE TROYER GROUP.WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALLDIMENSIONS AND CONDITIONS ON THE JOB AND SHALL NOTIFY THIS OFFICE OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BYTHESE DRAWINGS. IF THERE ARE DISCREPANCIES BETWEEN ANY ELECTRONIC FILE AND THE ORIGINAL, THE SEALED ORIGINAL SHALL GOVERN.PLOTTED: 10/07/2026 @ 3:38 PM, SAVED: 10/7/2026 @ 3:38 PM, BY: bcape, FILE: G:\projects\PS\Alliance Architects\O'Rourkes Patio\Design\Sheets\C1-100.dwgCopyright ©2026 00 5'10' LEGEND Storm Sewer Sanitary Sewer Underground Fiber Optic Underground Electric Underground Gas Underground Water Underground Traffic Conduit Storm Inlet Electric Manhole Traffic Manhole Traffic Control Cabinet Light Pole Sprinkler Control Valve (Text)Existing Conditions GENERAL NOTES 1.The Troyer Group, Inc. is not responsible for the accuracy of the existing conditions plan. Errors or omissions from the survey, changes to the project site after the survey was performed, or other factors may contribute to the discrepancies between this plan and job site conditions. Record drawings were used to supplement where no current survey data was generated. It is the responsibility of the contractor to determine current existing conditions prior to bidding the project. 2.Contractor shall call Indiana 811 or submit an Online Ticket with Exactix to begin the process for locating utilities and wait the required number of working days for utility locates prior to any excavation work. Protecting marked and unmarked utility locations are the sole responsibility of the Contractor. Damages to utilities shall be remedied by the Contractor at the discretion of the Owner to the satisfaction of the Owner at no additional cost to the Owner. 3.All edges of disturbed pavement shall be saw cut, full depth, to achieve clean, straight lines between existing and new pavement. 4.Contractor shall protect existing conditions, including pavement and subgrade facilities, not marked for demolition. Damages to existing conditions not marked for demolition shall be remedied by the Contractor at the discretion of the Owner to the satisfaction of the Owner at no additional cost to the Owner. 5.Contractor shall remove any hardscape elements not indicated in the survey that conflict with new improvements at the discretion of the Owner. 6.Contractor shall field verify all existing conditions. If discrepancies are discovered by the Contractor, the Contractor shall notify the Owner and Engineer immediately for coordination to remedy discrepancies. 7.Dispose of removed materials on a continuous and daily basis as needed. An accumulation of trash debris will not be permitted. 8.Refer to Architectural drawings for pergola dimensions and additional information. Murphy's Ice Cream Shoppe O'Rourke's Public House App. R/W App. R/W Refer to Architectural Plans for Pergola Details ST EH Th SC VKEYNOTES Protect Existing Planter Box Protect Existing Seat Wall Protect Existing Weep Hole in Seat Wall Protect Existing Sprinkler Control Valve 1 2 3 22 1 1 3 3 Verify Location and Protect Exist. Fiber Optic Line; Contractor Shall Coordinate w/ Owner if Exist. Fiber Optic Line is in Conflict w/ Proposed Improvements to Determine Relocation Plan Angela Blvd Approx. Disturbance Limits 1,170 Sft (0.03 Ac) Concrete Footing (Typ.); Refer to Architectural Plans for Additional Details Provide Minimum Clear Width of 5'-0" on Exist. Sidewalk to Maintain Pedestrian Access (Typ.) Remove and Relocate Exist. Planter Wall and Footing, Remove and Replace Planter Fill Material; Refer to Detail 1 This Sheet for Additional Information 4 4 Provide 4" Dia. Weep Hole Through North Face of Wall; Refer to Detail 1 This Sheet for Additional Information Scale: 1/2" = 1'-0" PLANTER SECTION1 THE SMART PERGOLA12958 BRIGHTON AVE.CARMEL, IN 46032S1O'ROURKE'S PUBLIC HOUSESOUTH BEND, IN THE SMART PERGOLA 12958 BRIGHTON AVE. CARMEL, IN 46032S2O'ROURKE'S PUBLIC HOUSE SOUTH BEND, IN THE SMART PERGOLA 12958 BRIGHTON AVE. CARMEL, IN 46032S3O'ROURKE'S PUBLIC HOUSE SOUTH BEND, IN BLED WALL SCONCE WITH ALUMINUM HOUSING ACRYLIC LENS, 700 LUMEN PACKAGE AT 10WATTS, 3000K, FINISH TO BE SELECTED BY ARCHITECT.MODEL LI000758-02B OR PRE APPROVED EQUALALIGHT FIXTURE SCHEDULEDESCRIPTIONSYMBOLVOLTCEILINGTYPEMOUNTINGREMARKSMANUFACTURERFIXTUREWATTAGEELECTRICAL LEGENDLEDCOL0R10 WATTS120WALLN/A3000KDAZUMALI000758-02BNOTES1. ALL ACRYLIC LENSES SHALL BE A MINIMUM 1/8" THICK.2.ALL LIGHT FIXTURES MARKED AS EMERGENCY LIGHTS (EM) SHALL BE EQUIPPED WITH BATTERY INVERTER CONNECTED TO A LOCAL UNSWITCHED CIRCUIT.3.ALL EMERGENCY/EXIT LIGHT FIXTURES SHALL BE CONNECTED TO A LOCAL UNSWITCHED LEG OF THE CIRCUIT INDICATED ON THE DRAWINGS.COMBINATION LED EMERGENCY/ EXIT LIGHT WITH GREEN LETTERS WITH WHITEPOLYCARBONATE HOUSING. WITH UNIVERSAL MOUNTING, SEALED NICAD BATTERY BACK UP W/REMOTE CAPACITY, FACES AND ARROWS AS INDICATED ON DRAWINGS.UNVCOMPASSCCGBOR EQUAL<5 WATTSUNIVERSALVARIESSSSINGLE POLE SWITCHSWITCH AND PILOT LIGHTD0-10 VDC LOW VOLATGE LIGHT DIMMER20A, 125V DUPLEX RECEPTACLE"WP" AT ANY RECEPTACLE SYMBOL INDICATES IT IS A WEATHERPROOFDEVICE WITH INTEGRAL GROUND FAULT CURRENT PROTECTION.WPRECEPTACLE MOUNTING HEIGHT = 1'-6"UNLESS NOTED "+" AT ANY RECEPTACLESYMBOL = 44" MOUNTING HEIGHT OR AS INDICATEDDUPLEX RECEPTACLE WITH INTEGRAL GROUND FAULT INTERRUPTERMOTOR LOCATIONNON-FUSED DISCONNECT SWITCH. 30A OR AS INDICATED.FUSED DISCONNECT SWITCH. 30A DISC. WITH XXXA FUSE OR AS INDICATED.CCONTROL/POWER CONNECTIONJJUNCTION BOX30A30/XXXJxx'xx' LOCATIONCC.B.COMB.DISC.E.C.G.C.H.O.A.LTG.MFG'R.M.C.M.D.P.O.L.RCPT.W.P.CONDUITCIRCUIT BREAKERCOMBINATIONDISCONNECTELECTRICAL CONTRACTOR/TRADEGENERAL CONTRACTOR/TRADEHAND-OFF-AUTOMATICLIGHTINGMANUFACTURERMECHANICAL CONTRACTOR/TRADEMAIN DISTRIBUTION PANELBOARDOVERLOADRECEPTACLEWEATHERPROOFABOVE FINISHED FLOORA.F.F.ABOVE FINISHED GRADEA.F.G.BELOW FINISHED CEILINGB.F.C.LAY IN GRIDL.I.G.1.ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL, STATE, AND LOCALCODES IN FORCE AT THE TIME OF BIDDING, INCLUDING, BUT NOT LIMITED TO,THE INDIANA CONSTRUCTION RULES AND NATIONAL ELECTRICAL CODE.2.DRAWINGS ARE DIAGRAMMATIC AND GENERALLY INDICATIVE OF WORKREQUIRED. THIS CONTRACTOR SHALL VERIFY IN FIELD ACTUAL DIMENSIONSAND LOCATIONS AND COORDINATE ELECTRICAL EQUIPMENT LOCATIONS WITHACTUAL EQUIPMENT PROVIDED PRIOR TO INSTALLATION OF ROUGH-INS. WHEREREQUIRED, ELECTRICAL ITEM LOCATIONS, MOUNTING HEIGHTS, ETC. SHALL BEREVISED AS REQUIRED TO ACCOMMODATE ADJACENT CASE WORK, COUNTERSAND OTHER EQUIPMENT AT NO ADDITIONAL COST TO THE OWNER.3.ALL CONDUITS SHALL BE CONCEALED WITHIN WALLS, CEILINGS OR FLOORSUNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR PRE-APPROVED BYTHE ARCHITECT/ENGINEER.4.INSTALL A SEPARATE GROUNDING CONDUCTOR, INSULATED GREEN, IN ALLCONDUITS. WHERE WIRING COUNTS ARE INDICATED ON DRAWINGS, THESEWIRING COUNTS EXCLUDE THE GROUNDING CONDUCTOR, HOWEVER,GROUNDING CONDUCTOR IS REQUIRED.5.MAINTAIN ACCURATE RECORDS OF ALL CHANGES MADE DURINGCONSTRUCTION. PROVIDE A NEATLY MARKED SET OF BLUEPRINTS TO THEENGINEER/ARCHITECT AT COMPLETION OF THE PROJECT, INDICATING ALL FIELDCHANGES.6.INCREASE BRANCH CIRCUIT CONDUCTORS TO ACCOMMODATE FOR VOLTAGEDROP. 120V CIRCUITS OVER 100' SHALL BE #10 AWG MINIMUM.7.ALL DEVICES, EQUIPMENT, FIXTURES, ETC., MUST BE GROUNDED BY USE OF APROPERLY SIZED GROUNDING CONDUCTOR. MECHANICAL/ELECTRICAL BONDSOF THE METALLIC RACEWAY SYSTEM SHALL ALSO BE MAINTAINED. REFER TOMECHANICAL PLANS FOR EXACT LOCATION OF MECHANICAL EQUIPMENT ANDLOCATE DISCONNECT SWITCHES IN ACCORDANCE WITH THE N.E.C.8.UNLESS OTHERWISE NOTED, ALL DEVICE ELEVATIONS REFER TO CENTER OFOUTLET BOX. (SEE SPECIFICATIONS.) DIV. 26 SHALL VERIFY ALL OUTLETLOCATIONS WITH OTHER TRADES.9.ALL RECEPTACLES SHOWN BACK-TO-BACK IN WALLS SHALL BE SEPARATED BY 8"MINIMUM.10.PROVIDE "SEAL-OFFS" WHEN PIPING PASSES THROUGH AREAS OF DIFFERENTAMBIENT TEMPERATURES AND/OR HAZARDOUS AREAS.11.PROVIDE AND INSTALL INSULATED COPPER GROUND BONDING JUMPER (SIZEDPER NEC) ACROSS INLET AND OUTLET PIPING OF ALL MECHANICAL UNITS ANDJUNCTIONS WHERE NON-METALLIC OR DISSIMILAR METALS INTERRUPT THEPATH TO GROUND. THESE ITEMS SHALL INCLUDE BUT ARE NOT LIMITED TO THEFOLLOWING:A. WATER HEATERSB. WATER METERC. WATER SOFTENERS14.ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CUTTING ANDPATCHING REQUIRED FOR THE PROPER INSTALLATION, SUPPORT, ORANCHORAGE OF ELECTRICAL EQUIPMENT. E.C. SHALL LAYOUT CAREFULLY INADVANCE WHERE CUTTING, CHANNELING OR DRILLING IS NECESSARY FOR THEPROPER COMPLETION OF ELECTRICAL WORK. COORDINATE WITH OTHERTRADES AS REQUIRED.GENERAL ELECTRICAL NOTESBELOW FINISHED GROUNDB.F.G.SLINE VOLTAGE FAN SPEED CONTROLLER. FURNISHED BY M.C. INSTALLED BY E.C.FPCPHOTOELECTRIC CONTROLPPPOWER PACK FOR LOW VOLTAGE MOTION SENSOR. SENSOR SWITCH OR EQUALMDLOW VOLTAGE MOTION SENSOR. SENSOR SWITCH CM SERIES OR EQUALMDLINE VOLTAGE MOTION SENSOR. SENSOR SWITCH CMR SERIES OR EQUALLVDT12 HR DIAL TIMER INTERMATIC MODEL #FF412H (OREQUAL) WITH SILVER COVERPLATE AND BLACK KNOBSURFACE MOUNTED PANELBOARDEXISTING ELECTRICSERVICE TO BUILDING.EXISTING PANEL "MA"600 AMP, 120/208 VOLT,3Ø,4WNOTE 1KWHNGEXISTINGELECTRICMETER.DETAIL NOTES:1. (4) #3/0, #6G, IN 2" C. ROUTE ABOVE ACCESSIBLE CEILING.4.2" DIAMETER, LED DOWNLIGHT FIXTURE, 24 VOLT, 6 WATT INPUT, 550 LUMEN OUTPUT,DIMMABLE, COMPLETE WITH POWER SUPPLY.RECESSED246 WATTS3000KN/ABY OWNERPTIME CLOCK - TORK MODEL 'DGLC' OR EQUALTCEXISTINGPANEL "MB"200 AMP,120/208 V,3Ø,4WEXISTINGPANEL "K"200 AMP,120/208 V,3Ø,4WNEWPANEL "MB2"200 AMP,120/208 V,3Ø,4WELECTRICAL EQUIPMENT SCHEDULEDESCRIPTIONMARKRADIANT HEATER:HEAVY DUTY CEILING MOUNTED, WHITE POWDER PAINT FINISH, 65 CFM, 10,239 BTUH, 3KW, 14.45 AMPS, 208V/1PH/60HZ. COMPLETE WITH WALL MOUNTED CONTROLS ANDRELAY PANEL, THERMAL CUT-OUT AND DISCONNECT SWITCH.INFRATECH 'C' SERIES "CD6024" OR EQUAL. PROVIDED BY OTHERS.CEILING FAN:72" DIAMETER, 6 BLADE, FINISH TO BE SELECTED BY OWNER, NO DOWNLIGHT, HANDHELD REMOTE, EC MOTOR, 120 VOLTBIG ASS FAN MAMMOTH OUTDOOR FAN MODEL NO. MM1-72 XXCF-1RH-1POWER SHADE:ROLLER SHADE, 120 VOLT, COMPLETE WITH CONTROLS. PROVIDED BY OTHERS,SOMFY SERIES 500 OR EQUAL.PS-1LIGHT FIXTURES AND POWER SUPPLY BY OTHERS.FIXTURES AND POWER SUPPLY TO BE INSTALLED BYE.C.GENERAL DEMOLITION NOTES1.THE ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING A BIDAND DETERMINE THE EXACT SCOPE OF DEMOLITION WORK.2.THE SUBMISSION OF A PROPOSAL WILL BE CONSIDERED AS EVIDENCE THAT THECONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE.CLAIMS MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND LABORBECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED IF THEYCOULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE.3.THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR PROTECTION OF ALLEXISTING BUILDING COMPONENTS DURING DEMOLITION/CONSTRUCTION. ALLCOSTS FOR LOCATING, REMOVING, REPLACING, OR RELOCATING SHALL BEINCIDENTAL TO DEMOLITION/CONSTRUCTION. ALL DAMAGES WHICH OCCURDURING DEMOLITION/CONSTRUCTION SHALL BE REPAIRED WITH LIKE MATERIALAT NO ADDITIONAL COST TO THE OWNER.4.WHERE WALLS TO REMAIN ARE DAMAGED BY THE REMOVAL OF ANY ELECTRICALEQUIPMENT, THIS CONTRACTOR SHALL PATCH AS REQUIRED TO MATCHADJACENT SURFACES.5.THE OWNER RETAINS FIRST SALVAGE RIGHTS TO ALL EQUIPMENT. ITEMS THATTHE OWNER WISHES TO RETAIN SHALL BE DELIVERED TO THE OWNERSSTORAGE AREA. ALL OTHER MATERIALS SHALL BE REMOVED FROM THE SITEIMMEDIATELY.6.COORDINATE SCHEDULE OF DEMOLITION WORK WITH THE OTHER TRADES.COORDINATE SHUTDOWN OF MAIN SERVICES WITH OWNER (I.E. POWER,TELEPHONE, ETC.).7.IF EXISTING CIRCUITS TO REMAIN ARE DISRUPTED DURING DEMOLITION ORCONSTRUCTION REPAIR AND REROUTE AS REQUIRED.NOT TO SCALEONE-LINE DIAGRAM1E0.1DATE: ALLIANCE ARCHITECTSALL RIGHTS RESERVEDSHEET NO.2026cO'ROURKE'S PATIO ENCLOSURE KITE Realty Group 1044 E. Angela Blvd., Suite 103 South Bend, IN 4661710/7/26E0.1INDIAN A RE GI STEREDSTATE OFPE11100682No.BR A DLEY A. WHITEPROFESSIONAL ENG INEER Q:\Alliance Projects\Kite\O'Rourkes Patio\Drawings\AutoCAD\E0.1 ELECTRICAL LEGEND, NOTES, LIGHT FIXTURE SCHEDULE.dwg, 10/7/2026 9:48:07 AM, DWG To PDF Alliance - High Res.pc3 SECTION 260000ELECTRICALPART 1: GENERAL1.1GENERALA.THE WORK INDICATED IN THIS DIVISION AND ON THE ELECTRICAL DRAWINGS IS SUBJECT TO THE REQUIREMENTS OF THE INSTRUCTIONS TO BIDDERS (DIVISION 0) ANDGENERAL CONDITIONS (DIVISION 1). THESE ARE HEREBY INCLUDED BY REFERENCE. THE CONTRACTOR IS DIRECTED TO EXAMINE ALL PORTIONS OF THE BIDDOCUMENTS AS THEY PERTAIN TO THE WORK COVERED BY THIS DIVISION OF THE SPECIFICATIONS AND TO INCLUDE ALL COSTS IN BID FOR ALL ELECTRICAL WORK ASCALLED FOR BY THE COMPLETE BID DOCUMENTS.B.PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT AND CONTRACTOR SERVICES NECESSARY FOR THE COMPLETE INSTALLATION OF EQUIPMENT INDICATEDHEREIN AND ON THE DRAWINGS, COMPLETE WITH ALL RELATED SERVICES. REVIEW ALL EXISTING BUILDING CONDITIONS AS THEY RELATE TO ELECTRICAL WORK ANDINCLUDE COSTS IN BID. COORDINATE REQUIREMENTS WITH OTHER TRADES AS REQUIRED.C.ALL WORK SHALL BE PERFORMED BY EXPERIENCED PERSONNEL QUALIFIED TO CARRY OUT THE WORK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS,LOCAL CODES AND AS SPECIFIED HEREIN. THE CONTRACTOR SHALL PROVIDE APPROPRIATE QUALIFICATIONS AND RECORDS OF PAST EXPERIENCE FOR PERSONNELAND SUBCONTRACTORS WHEN REQUESTED BY THE ENGINEER/ARCHITECT FOR REVIEW AND APPROVAL.D.THE ELECTRICAL CONTRACTOR/TRADE SHALL BE RESPONSIBLE FOR COORDINATION AND DISTRIBUTION OF WORK TO HIS SUBCONTRACTORS AND SHALL VERIFYCOMPLETENESS OF SUBMITTALS AND WORK.E.CONTRACTOR SHALL NOT CUT ANY BEAM OR COLUMNS OR ANY PORTION OF STRUCTURAL SYSTEM WITHOUT SPECIFIC PERMISSION. CONTRACTOR SHALL COORDINATEWITH OWNER/ARCHITECT/ENGINEER.F.DIVISION OF RESPONSIBILITY FOR VARIOUS ASPECTS OF THE WORK SHALL BE AS OUTLINED IN DIVISIONS 0 AND 1OF THE SPECIFICATIONS. RESPONSIBILITY FORCOORDINATION WITH OTHER TRADES IS THE RESPONSIBILITY OF ALL TRADES.1.2CONTRACT DOCUMENTSA.THE ELECTRICAL DRAWINGS LISTED IN THE DRAWING INDEX, TOGETHER WITH THESE SPECIFICATIONS, ARE AN INTEGRAL PART OF THE ELECTRICAL CONTRACT. WHATIS CALLED FOR IN ONE IS AS BINDING AS IF CALLED FOR IN BOTH. IN CASE OF CONFLICT, THE GREATER QUANTITY OR BETTER QUALITY IS TO PREVAIL, SUBJECT TO THEAPPROVAL OF THE ENGINEER/ARCHITECT.B.THE ELECTRICAL AND MECHANICAL DRAWINGS ARE DIAGRAMMATIC ONLY, BUT ARE TO BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION OF THE PROJECT ANDWORK OF OTHER TRADES WILL PERMIT. MINOR CHANGES FROM THESE DRAWINGS, NECESSARY TO COORDINATE WITH THE WORK OF OTHER TRADES AND TO MAKETHE WORK OF THIS CONTRACTOR CONFORM TO THE PROJECT AS CONSTRUCTED, ARE TO BE MADE AT NO ADDITIONAL COST TO THE OWNER.C.ELECTRICAL AND MECHANICAL DRAWINGS ARE NOT TO BE SCALED FOR THE PURPOSE OF EQUIPMENT INSTALLATION. ALL MEASUREMENTS TO BE DERIVED FROMARCHITECTURAL AND SHOP DRAWINGS AND COORDINATED WITH FIELD CONDITIONS. ALL MEASUREMENTS MUST BE VERIFIED. THE CONTRACTOR IS RESPONSIBLE FORALL WORK FITTING INTO PLACE IN A SATISFACTORY AND WORKMANLIKE MANNERD.INCREASED COST OF WIRING RESULTING FROM INCREASED ELECTRICAL RATINGS OVER THAT SHOWN ON THE ELECTRICAL DRAWINGS IS TO BE BORNE BY THECONTRACTOR FURNISHING THE EQUIPMENT.E.INCLUDE CONTROL WIRING, AS CALLED FOR ON THE DRAWINGS AND SPECIFICATIONS (AND INDICATED AS BEING BY THE ELECTRICAL CONTRACTOR OR TRADE), ASELECTRICAL WORK AND COORDINATE WITH THE MECHANICAL CONTRACTOR.F.ARRANGE WORK FOR MAXIMUM CLEARANCE AND ACCESSIBILITY TO ALL WORK OF THIS TRADE AS WELL AS OTHER TRADES. COORDINATE WITH EXISTING CONDITIONS.1.3ALLOWANCESA.SEE DIVISION 1 OF THE SPECIFICATIONS.1.4CODES, STANDARDS AND PERMITSA.ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL CODES IN FORCE AT TIME OF BIDDING, INCLUDING BUT NOT LIMITED TO THE NATIONALELECTRICAL CODE. IN ADDITION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND INSPECTION APPROVALS AS THE WORKPROGRESSES. ANY WORK WHICH IS COMPLETED WITHOUT THESE APPROVALS AND FOUND TO BE UNACCEPTABLE SHALL BE CORRECTED BY THE CONTRACTOR AT NOADDITIONAL COST.B.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PAYMENT OF ALL FEES ASSOCIATED WITH INSPECTIONS, PERMITS AND UTILITY CONNECTIONS UNLESS OTHERWISEINDICATED.C.ALL STANDARDS REFERENCED IN THIS DIVISION OR ON THE DRAWINGS SHALL COMPLY WITH THE LATEST EDITION IN FORCE. MATERIAL AND EQUIPMENT FURNISHEDAND INSTALLED UNDER THESE SPECIFICATIONS WHICH, IN THE OPINION OF THE ENGINEER/ARCHITECT, DO NOT COMPLY WITH THE STANDARDS OF THE ORGANIZATIONSLISTED, ARE TO BE REPLACED WITHOUT ADDITIONAL COST TO THE OWNER. STANDARDS SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING:NFPANATIONAL FIRE PROTECTION ASSOCIATIONULUNDERWRITERS' LABORATORIESNEMANATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATIONIEEEINSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERSICEAINSULATED CABLE ENGINEERS ASSOCIATIONSASTMAMERICAN SOCIETY FOR TESTING AND MATERIALS1.5DEFINITIONSA.CONCEALED: EMBEDDED IN WALLS, CEILINGS, FLOORS OR OTHER SPACES. NOT EXPOSED TO VIEW.B.EXPOSED: NOT CONCEALED OR INSTALLED UNDERGROUND.C.FURNISH, PROVIDE: TO SUPPLY, INSTALL, CONNECT AND PUT INTO OPERATION.D.WORK: WIRING, EQUIPMENT, RACEWAYS, COORDINATION, ETC. AS REQUIRED BY THE CONTRACT DOCUMENTS FOR A COMPLETE AND OPERATING SYSTEM.1.6MATERIALS AND EQUIPMENTA.WHERE "APPROVED EQUAL" CLAUSE IS INDICATED, IT MEANS MATERIAL, APPARATUS, EQUIPMENT AND SUPPLIES HAVING RECOGNIZED STANDARDS OF QUALITY ANDPERFORMANCE WHICH, IN THE JUDGEMENT OF THE ENGINEER/ARCHITECT, WILL MEET THE DESIGN AND SPECIFICATION REQUIREMENTS. MATERIAL AND EQUIPMENT BYMANUFACTURERS OTHER THAN THOSE LISTED IN THE PLANS OR SPECIFICATIONS MUST BE SUBMITTED TO THE ENGINEER/ARCHITECT FOR APPROVAL NOT LATER THANTEN (10) WORKING DAYS PRIOR TO THE DUE DATE FOR BIDS.B.WHERE "OR EQUAL" CLAUSE IS INDICATED, IT MEANS MATERIAL AND EQUIPMENT OF EQUAL OR BETTER QUALITY AND PERFORMANCE THAN THAT LISTED IN THE PLANSAND SPECIFICATIONS, EXCEPT THAT NO APPROVAL PRIOR TO BIDDING IS REQUIRED.1.7SHOP DRAWINGS AND SUBMITTALSA.PROVIDE ALL SUBMITTALS AS CALLED FOR IN DIVISION 1OF THE SPECIFICATIONS, INCLUDING SHOP DRAWINGS, SAMPLES, MATERIAL LISTS, SCHEDULE OF VALUE, ETC.SHOP DRAWINGS SHALL BE COMPLETELY REVIEWED AND APPROVED BY THE CONTRACTOR AND TRADE FURNISHING THE EQUIPMENT (INDICATED BY THECONTRACTOR’S APPROVAL STAMP) PRIOR TO SUBMITTING TO THE ENGINEER/ARCHITECT.B.WHERE SHOP DRAWING SUBMITTALS ARE ASSEMBLED IN A FOLDER OR BOUND SETS, ALL FOLDERS OR SETS ARE TO BE IDENTICAL AND EACH SET MUST CONTAIN ANINDEX OF THE ITEMS ENCLOSED IN THE SET OR FOLDER. QUANTITY OF ORIGINAL COLOR SAMPLES REQUIRED SHALL BE COORDINATED WITH THE ARCHITECT.C.REVIEW AND APPROVAL OF SHOP DRAWINGS BY THE ENGINEER/ARCHITECT IS FOR GENERAL CONFORMITY TO DESIGN INTENT ONLY. THIS REVIEW DOES NOTAUTHORIZE CHANGES TO THE CONTRACT SUM OR RELIEVE THE CONTRACTOR IN ANY WAY OF HIS CONTRACT OBLIGATIONS.1.8ELECTRICALA.COORDINATE ALL WORK REQUIRING ELECTRICAL CONNECTION WITH THE CONTRACTOR PROVIDING THE EQUIPMENT. EXCEPT AS OTHERWISE INDICATED, ADDITIONALINTERNAL WIRING, AUTOMATIC CONTROL WIRING, PROTECTIVE DEVICES, ETC. ASSOCIATED WITH WORK FURNISHED BY THE OTHER TRADES SHALL BE FURNISHED BYTHE TRADE SUPPLYING THE EQUIPMENT.B.VERIFY VOLTAGE AND PHASE CHARACTERISTICS OF THE ELECTRICAL SERVICE AND COORDINATE WITH MECHANICAL EQUIPMENT AS REQUIRED.C.WHERE ELECTRICAL RATINGS OF EQUIPMENT INCREASE OVER THOSE INDICATED ON THE APPROVED CONSTRUCTION DOCUMENTS, THE CONTRACTOR PROVIDING THEEQUIPMENT SHALL PAY ADDITIONAL COSTS OF WIRING AND ELECTRICAL EQUIPMENT FOR PROPER ELECTRICAL SERVICE TO THE EQUIPMENT.D.PROVIDE SUBMITTALS FOR THE FOLLOWING:1.RACEWAYS2.CONDUCTORS3.WIRING DEVICES4.DISTRIBUTION EQUIPMENT5.OVERCURRENT PROTECTION6.LIGHT FIXTURES7.FIRESTOPPINGE.PROVIDE ARC FLASH WARNING LABELS ON ELECTRICAL EQUIPMENT AS REQUIRED BY THE NATIONAL ELECTRICAL CODE. ELECTRICAL EQUIPMENT SHALL INCLUDE BUTIS NOT LIMITED TO THE FOLLOWING:1.SWITCHBOARDS2.PANELBOARDS3.DISCONNECT SWITCHES1.9PAINTING AND FINISHINGA.UNLESS OTHERWISE INDICATED IN OTHER DIVISIONS OF THE SPECIFICATIONS, AT NO ADDITIONAL COST TO THE OWNER, REPAINT ALL PATCHED AREAS TO MATCHORIGINAL FINISH WHERE HOLES OR CHASES HAVE BEEN CUT TO RECEIVE ELECTRICAL WORK. REPAINT PATCHED AREAS WITH TWO (2) COATS OF PAINT TO MATCHSURROUNDING AREAS; BLEND AS REQUIRED.B.UNLESS OTHERWISE INDICATED IN OTHER DIVISIONS OF THE SPECIFICATIONS, AT NO ADDITIONAL COST TO THE OWNER, GIVE ALL FABRICATED STEEL SUPPORTS,HANGERS, BRACKETS AND PLATFORMS INSTALLED UNDER THIS CONTRACT TWO (2) COATS OF HIGH-GRADE ENAMEL.C.TOUCH UP MARRED SURFACES OF EQUIPMENT HOUSING WITH ENAMEL OF A COLOR TO MATCH.1.10DEMOLITIONA.BEFORE STARTING DEMOLITION WORK, REVIEW ALL REQUIREMENTS FOR FINAL REMODELING WORK SO THAT USABLE EXISTING SYSTEM COMPONENTS, AS REQUIREDFOR COMPLETION OF THE NEW WORK, ARE NOT DESTROYED. COORDINATE ALL WORK WITH THE OTHER CONTRACTORS.B.ALL ELECTRICAL EQUIPMENT AND CIRCUITS THAT ARE DAMAGED OR DESTROYED DURING DEMOLITION, AND ARE NOT CALLED OUT TO BE REMOVED ON THE DRAWINGS,MUST BE RESTORED TO ORIGINAL CONDITION.C.PROVIDE ALL LABOR, MATERIALS AND NECESSARY COORDINATION FOR DEMOLITION WORK AS CALLED FOR BY THE CONTRACT DOCUMENTS. REMOVAL SHALL BEPARTIAL OR COMPLETE AS CALLED FOR AND SHALL BE COORDINATED WITH OTHER TRADES AND NEW CONSTRUCTION. WORK SHALL ALSO INCLUDE MISCELLANEOUSITEMS RELATED TO WORK INDICATED WHERE NOT REUSED FOR NEW CONSTRUCTION.D.THE CONDITION OF THE SITE, BUILDINGS AND SURROUNDINGS SHALL BE ACCEPTED AS FOUND. RESPONSIBILITY FOR CONDITIONS ARE SOLELY THE RESPONSIBILITY OFTHE CONTRACTOR.E.WORK PRACTICES AND JOB CONDITIONS SHALL MEET ALL STATE, FEDERAL AND LOCAL REQUIREMENTS TO PROTECT LIFE AND PROPERTY.F.PROVIDE SHORING AND/OR BRACING AS REQUIRED TO PROTECT AGAINST COLLAPSE OR SETTLING.G.VERIFY WORK TO BE PERFORMED BEFORE PROCEEDING. WORK TO REMAIN SHALL BE PROTECTED AND, IF DAMAGED, SHALL BE RESTORED TO LIKE NEW CONDITION.WHERE DEMOLITION DRAWINGS INDICATE THE REMOVAL OF RECEPTACLES, LIGHT FIXTURES, ETC., REROUTE BRANCH CIRCUITS AS REQUIRED SO THAT ADDITIONALEXISTING DEVICES AND EQUIPMENT CONNECTED TO THIS BRANCH CIRCUIT REMAIN IN SERVICE. WHERE ARCHITECTURAL DRAWINGS INDICATE WALLS, CEILINGS,FLOORS, PARTITIONS, ETC. TARGETED FOR REMOVAL, THIS CONTRACTOR SHALL ALSO PROVIDE ALL ASSOCIATED ELECTRICAL DEMOLITION WORK WHETHER OR NOTSPECIFICALLY INDICATED ON THE ELECTRICAL DRAWINGS. WHERE MECHANICAL DRAWINGS INDICATE MECHANICAL EQUIPMENT TARGETED FOR REMOVAL THISCONTRACTOR SHALL PROVIDE ALL ASSOCIATED ELECTRICAL DEMOLITION WORK WHETHER OR NOT SPECIFICALLY INDICATED ON THE ELECTRICAL DRAWINGS. IF NOOTHER EQUIPMENT IS CONNECTED TO BRANCH CIRCUIT IT SHALL BE REMOVED COMPLETE BACK TO BRANCH PANELBOARD. THIS SHALL INCLUDE REMOVAL OFRACEWAYS TO ½" BELOW SURFACE TO REMAIN, WHERE RACEWAYS ENTER FLOORS, WALLS OR CEILINGS.H.PLUG, CAP OR DISCONNECT ACTIVE LINES AND SERVICES AS APPLICABLE. WORK SHALL BE PERFORMED BY QUALIFIED, LICENSED PERSONNEL.I.IF ANY MATERIALS WHICH MIGHT BE CLASSIFIED AS HAZARDOUS WASTE ARE LOCATED, THE OWNER SHALL BE NOTIFIED. THE CONTRACTOR SHALL THEN WAIT UNTILNOTIFIED THAT HAZARDOUS WASTE HAS BEEN REMOVED BEFORE CONTINUING WITH WORK.J.TURN OVER ANY PERSONAL PROPERTY DISCOVERED DURING THE DEMOLITION PROCESS TO THE OWNER.K.DEBRIS SHALL BE REMOVED FROM THE SITE ON A REGULAR BASIS. IF DEBRIS REMAINS AFTER COMPLETION OF DEMOLITION OR IS ALLOWED TO OBSTRUCT OTHEROPERATIONS, THE OWNER AND ENGINEER/ARCHITECT RESERVE THE RIGHT TO HAVE MATERIAL REMOVED. ALL COSTS OF SAID REMOVAL WILL BE BILLED TO THECONTRACTOR OR CHARGED AGAINST CONTRACTOR PAY REQUESTS AT THE DISCRETION OF THE OWNER AND ENGINEER/ARCHITECT. LEAVE SITE IN A NEAT ANDORDERLY CONDITION.L.PROTECT AREAS TO REMAIN FROM WEATHER. WEATHER DAMAGE SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.1.11RECORD DRAWINGA.PROVIDE ELECTRICAL RECORD DRAWINGS AS CALLED FOR IN DIVISION 1 AND INCLUDE ALL PERTINENT INFORMATION NOT SHOWN AND ALL CHANGES FROM THEORIGINAL PLANS: ROUTE OF ALL UNDERGROUND AND OVERHEAD FEED CONDUITS FROM THE MAIN SWITCHBOARD TO THE VARIOUS PANELS AND EQUIPMENT;INTERCONNECTING CONDUITS BETWEEN BRANCH CIRCUIT, JUNCTION BOXES, AND PANELS (ACTUAL ROUTE OF CONDUIT IS NOT REQUIRED, EXCEPT FOR CONCEALEDPANEL AND MAJOR EQUIPMENT FEEDERS, ONLY HOW THE VARIOUS BRANCH ITEMS ARE INTERCONNECTED WITH CONDUIT AND NUMBER OF WIRES); CIRCUIT NUMBERSFOR ALL ITEMS WHERE THEY DO NOT AGREE WITH THE PLANS. CIRCUIT NUMBERS ON RECORD DRAWINGS AND PANELBOARD DIRECTORIES MUST AGREE.1.12CHANGES, CONTRACT DOCUMENTSA.THE CONTRACT DOCUMENT MAY BE SUPERSEDED BY LATER REVISED DRAWINGS OR SPECIFICATION ADDENDA PREPARED BY THE ENGINEER/ARCHITECT, AND ALLREASONABLE CHANGES (UP TO 3 FEET) IN LOCATION OF EQUIPMENT PRIOR TO ITS INSTALLATION, SHALL BE MADE WITHOUT ADDITIONAL COST TO THE OWNER.1.13OPERATING AND MAINTENANCE MANUALS AND INSTRUCTIONA.PROVIDE TWO (2) BOUND SETS OF COMPLETE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS OR AS OUTLINED IN DIVISION 1OF THESE SPECIFICATIONS.MANUALS SHALL ALSO INCLUDE SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT, COMPLETE PARTS LISTS, ACOMPLETE NARRATIVE EXPLAINING HOW EACH SYSTEM IS INTENDED TO OPERATE, COPIES OF ORIGINAL SHOP DRAWINGS, ELECTRICAL CONTRACTOR’S NAME ANDADDRESS WITH SUBCONTRACTOR LISTS OF NAMES AND ADDRESSES, WARRANTIES, WARNINGS, ETC. GENERIC INSTRUCTIONS SHALL HIGHLIGHT APPLICABLESECTIONS, WHEN NEEDED, TO DIFFERENTIATE FROM NON-RELEVANT EQUIPMENT.B.UPON COMPLETION OF THE WORK, AND AT A DESIGNATED TIME, PROVIDE INSTRUCTIONS TO THE OWNER'S REPRESENTATIVE IN OPERATION AND MAINTENANCE OF ALLMECHANICAL EQUIPMENT. NOTIFY ENGINEER/ARCHITECT OF SCHEDULED TIME AND PLACE.C.TURN OVER TO OWNER ALL TOOLS SUPPLIED WITH EQUIPMENT.1.14WORKMANSHIPA.INSTALL ALL MATERIALS AND EQUIPMENT IN A NEAT AND WORKMANLIKE MANNER AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, ASAPPROVED BY THE ENGINEER/ARCHITECT TO CONFORM WITH THE CONTRACT DOCUMENTS.B.PROVIDE TESTING AND START-UP FOR ALL EQUIPMENT AS RECOMMENDED BY MANUFACTURER UNLESS DIRECTED OTHERWISE.1.15SUPERVISIONA.HAVE A THOROUGHLY COMPETENT SUPERINTENDENT IN CHARGE OF THE WORK AT ALL TIMES, EXPERIENCED IN THE WORK TO BE DONE UNDER THIS CONTRACT.REPLACE ANYONE NOT DEEMED CAPABLE BY THE ENGINEER/ARCHITECT UPON REQUEST IMMEDIATELY, BY ONE WHO IS SATISFACTORY. A SATISFACTORYSUPERINTENDENT, ONCE ASSIGNED, IS NOT TO BE REMOVED WITHOUT THE CONSENT OF THE ENGINEER/ARCHITECT.1.16TESTSA.AFTER THE INSTALLATION IS COMPLETED, AND AT SUCH TIME AS THE ENGINEER/ARCHITECT MAY DIRECT, THE CONTRACTOR IS TO CONDUCT AN OPERATING TEST FORAPPROVAL. DEMONSTRATE EQUIPMENT TO OPERATE IN ACCORDANCE WITH THE REQUIREMENTS OF THIS SPECIFICATION. PERFORM TESTS IN THE PRESENCE OF THEENGINEER/ARCHITECT OR HIS AUTHORIZED REPRESENTATIVE. THE CONTRACTOR IS TO FURNISH ALL INSTRUMENTS AND PERSONNEL REQUIRED FOR THE TESTS. THECONTRACTOR IS TO SUBMIT, IN WRITING, TO THE ENGINEER/ARCHITECT UPON COMPLETION OF THE PROJECT, THE MEASURED GROUND RESISTANCE OF EACH GROUNDROD, INCLUDING LOCATION OF THE ROD AND THE RESISTANCE AND SOIL CONDITIONS AT THE TIME THE MEASUREMENTS WERE MADE.1.17GUARANTEES AND WARRANTIESA.ALL LABOR, MATERIALS AND EQUIPMENT SHALL BE GUARANTEED BY THE CONTRACTOR AND WARRANTED BY THE MANUFACTURER FOR A PERIOD OF ONE YEAR FROMTHE DATE OF FINAL ACCEPTANCE BY THE OWNER, UNLESS LONGER PERIOD IS SPECIFIED FOR SPECIFIC EQUIPMENT. LAMP GUARANTEE IS LIMITED TO REPLACING ALLDEFECTIVE OR NON-OPERATING LAMPS INSTALLED UNDER THIS CONTRACT AT TIME OF SUBSTANTIAL COMPLETION.B.THE CONTRACTOR SHALL MAKE ALL NECESSARY REPAIRS AND ALTERATIONS DURING THE GUARANTEE PERIOD AS MAY BE REQUIRED BY THE OWNER OR ARCHITECTFOR CORRECT SYSTEM OPERATION AND TO COMPLY WITH THE DRAWINGS AND SPECIFICATIONS. THESE REPAIRS AND ALTERATIONS SHALL BE AT NO ADDITIONALCOST TO THE OWNER.C.THE OWNER RESERVES THE RIGHT TO MAKE EMERGENCY SYSTEM REPAIRS WITHOUT VOIDING THE CONTRACTOR'S GUARANTEE.1.18TEMPORARY SERVICEA.FURNISH AND MAINTAIN TEMPORARY POWER AND LIGHTING SYSTEM FOR WORK WITHIN BOUNDARIES OF CONSTRUCTION. REMOVE AT COMPLETION OF PROJECT.VERIFY SAFE USE OF SYSTEM. TEMPORARY LIGHTING SHALL MEET OSHA MINIMUM LEVELS FOR TYPE OF WORK BEING PERFORMED.1.19UTILITY COORDINATIONA.THE TERM UTILITY SHALL APPLY TO ELECTRICAL, TELEPHONE, NATURAL GAS OR CABLE TELEVISION UTILITIES, AS REQUIRED BY WORK OF THIS CONTRACT.B.COORDINATE NEW SERVICES WITH OWNER AND UTILITY COMPANIES AS APPLICABLE.C.COORDINATE ANY ELECTRIC UTILITY OUTAGE WITH THE OWNER. FURNISH TEMPORARY POWER CONNECTIONS AS REQUIRED TO MAINTAIN OWNER OPERATIONS FOREXTENDED OUTAGES EXCEEDING 8 HOURS. CONTRACTOR SHALL INCLUDE IN BASE BID COST ALL EXPENSES TO PERFORM AFTER-HOURS PRE-ARRANGED OUTAGES.PART 2: PRODUCTS2.1RACEWAYSA.PROVIDE AND INSTALL RACEWAYS AS REQUIRED FOR THE NEW WORK. ALL CONDUITS WILL BE CONCEALED BELOW GRADE OR WITHIN THE STRUCTURAL ELEMENTS OFTHE BUILDING. RACEWAYS WILL BE RIGID METAL CONDUIT (RMC), INTERMEDIATE METALLIC CONDUIT (IMC), OR ELECTRICAL METALLIC TUBING (EMT) AS ALLOWED BYTHE NEC. MINIMUM RACEWAY SIZE WILL BE THREE-QUARTER (3/4) INCH.B.HEAVY WALL PVC CONDUIT MAY BE USED BELOW GRADE, IN CONCRETE SLABS OR WHERE NOT EXPOSED TO PHYSICAL DAMAGE. PROVIDE RIGID METAL CONDUIT (RMC)WHERE INSTALLED ABOVE GRADE AND EXPOSED TO ELEMENTS.2.2CONDUCTORSA.CONDUCTORS WILL BE THHN, THWN, OR XHHW, SIZED AS INDICATED AND INSTALLED IN ACCORDANCE WITH THE NEC. NO. 12 AWG WILL BE THE MINIMUM CONDUCTORSIZE ALLOWED FOR BRANCH CIRCUIT WIRING. BRANCH CIRCUIT LENGTHS EXCEEDING ONE HUNDRED FEET (100') FOR 120-VOLT CIRCUITS AND OF 277 VOLTS, MORETHAN TWO HUNDRED THIRTY FEET (230') LONG, FROM PANEL TO LOAD CENTER, TO BE NO. 10 AWG MINIMUM.B.CLASS 1 REMOTE-CONTROL AND SIGNAL CIRCUIT CONDUCTORS WILL NOT BE LESS THAN NO. 14 AWG. CLASS 2 LOW-ENERGY REMOTE-CONTROL AND SIGNAL CIRCUITCONDUCTORS WILL NOT BE LESS THAN NO. 16 AWG.C.PROVIDE IDENTIFYING WIRE COLORS AS FOLLOWS:COLOR CODE WIRE FOR 120/208 VOLT, THREE PHASE, FOUR WIRE SYSTEMS AS FOLLOWS:1.A-PHASE: BLACK2.B-PHASE: RED3.C-PHASE: BLUE4.NEUTRAL: WHITE5.GROUND: GREEN2.3WIRING DEVICESA.PROVIDE WIRING DEVICES AND PLATES AS INDICATED BY THE CONTRACT DOCUMENTS. UNLESS OTHERWISE INDICATED, DEVICES WILL BE STANDARD NEMACONFIGURATIONS FOR THE PARTICULAR APPLICATION.B.ALL DEVICES AND PLATES WILL BE SPECIFICATION-GRADE, 20-AMP MINIMUM, UNLESS OTHERWISE INDICATED OR REQUIRED. COORDINATE COLOR AND TYPE WITH THEARCHITECT/OWNER PRIOR TO ORDERING.C.PROVIDE DEVICES AS MANUFACTURED BY COOPER WIRING, HUBBELL, GENERAL ELECTRIC OR PASS & SEYMOUR.2.4DISCONNECTING MEANSA.PROVIDE HEAVY-DUTY TYPE SAFETY SWITCHES OR MOTOR-RATED TOGGLE SWITCHES AS INDICATED ON THE DRAWINGS AND AS REQUIRED BY THE NEC.B.DISCONNECT SWITCHES ARE TO BE INSTALLED WITHIN SIGHT OF ALL EQUIPMENT REQUIRING A MEANS OF DISCONNECT. OUTDOOR ENCLOSURES WILL BE NEMA 3R.2.5MOTOR PROTECTIONA.OVERLOAD DEVICES WILL BE OF THE MANUALLY RESET TYPE UNLESS OTHERWISE NOTED. SIZES FOR THERMAL OVERLOADS WILL BE DETERMINED FOR THE ACTUALMOTOR PROVIDED WITH EACH PIECE OF EQUIPMENT IN THE FIELD. PHASE-LOSS RELAYS ARE REQUIRED FOR ALL THREE-PHASE MOTORS. SIZE AND INSTALL OVERLOADDEVICES IN ACCORDANCE WITH MANUFACTURER'S AND NATIONAL ELECTRICAL CODE REQUIREMENTS.B.PROVIDE THERMAL OVERLOAD PROTECTION FOR ALL MOTORS. WHERE MOTORS ARE NOT PROVIDED WITH INTERNAL THERMAL OVERLOAD PROTECTION, PROVIDEPROTECTION AS A PART OF CONTROLLER OR DISCONNECT.C.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DIRECTION OF MOTOR ROTATION. DAMAGE TO MOTORS, EQUIPMENT OR SYSTEMS, DUE TO IMPROPER ROTATION, WILLBE REPAIRED OR REPLACED AT NO ADDITIONAL COST TO OWNER.2.6BRANCH/DISTRIBUTION PANELBOARDSA.PANELBOARDS WILL BE "BOLT-ON" CIRCUIT BREAKER TYPE, 10,000 AIC MINIMUM FOR 120-VOLT AND 14,000 AIC MINIMUM FOR 277-VOLT. PROVIDE COMPLETE WITH ALLBREAKERS AS NOTED, A DEAD FRONT ASSEMBLY AND HINGED COVER WITH A LOCK.B.WHERE REQUIRED, PROVIDE PANELBOARDS THAT ARE LABELED AS SERVICE ENTRANCE EQUIPMENT.C.PROVIDE CIRCUIT DIRECTORY FRAME AND CARD WITH CLEAR PLASTIC COVERING ON THE INSIDE OF EACH PANELBOARD DOOR. DIRECTORIES WILL BE TYPED. PROVIDENEW DIRECTORIES IN EXISTING PANELBOARDS TO WHICH NEW BRANCH CIRCUITS ARE CONNECTED.2.7POWER DISTRIBUTION EQUIPMENTA.POWER DISTRIBUTION EQUIPMENT IS TO BE PROVIDED BY CUTLER-HAMMER, GENERAL ELECTRIC, SIEMENS OR SQUARE D.2.8LIGHT FIXTURES AND LAMPSA.PROVIDE AND INSTALL ALL LIGHT FIXTURES, AND RELATED EQUIPMENT AND COMPONENTS, INCLUDING ALL LAMPS, NECESSARY TO MAKE A COMPLETE AND OPERATINGLIGHTING SYSTEM AS INDICATED ON THE DRAWINGS.B.TAKE NOTE OF SPECIAL CEILING SYSTEMS, SLOPES, ETC. FURNISH FIXTURES OF A TYPE SUITABLE FOR INSTALLATION IN THE VARIOUS CEILING SYSTEMS. FIXTURESWILL BE COMPLETE WITH ALL REQUIRED MOUNTING ACCESSORIES AND HARDWARE.C.PROVIDE CONCRETE BASES, SHIMS, THREADED MOUNTING RODS, MOUNTING TEMPLATES, ETC. AS REQUIRED FOR EXTERIOR LIGHTING.2.9GROUNDING:A.PROVIDE GROUNDING FOR ALL EQUIPMENT AND SERVICES IN ACCORDANCE WITH THE NEC. PROVIDE GROUNDING CONDUCTORS IN ALL METALLIC AND NONMETALLICRACEWAYS. NOTE THAT GROUNDING CONDUCTORS ARE NOT INDICATED ON THE DRAWINGS (WHERE WIRE COUNTS ARE SHOWN) BUT ARE REQUIRED TO BE PROVIDEDIN ALL RACEWAYS.B.GROUNDING CONDUCTORS TO BE COPPER WIRE, OF THE SIZE REQUIRED BY THE NATIONAL ELECTRIC CODE OR AS SHOWN ON THE CONTRACT DRAWINGS. MAKE ALLCONNECTIONS AND SPLICES IN THE GROUNDING SYSTEM BY MEANS OF SOLDERLESS CONNECTORS.C.UNLESS OTHERWISE SHOWN ON THE CONTRACT DRAWINGS, ABOVE-GRADE GROUNDING CONNECTIONS SHALL BE MECHANICAL COMPRESSION TYPE.D.GROUNDING BUSHINGS SHALL BE INSULATED TYPE. INSTALL GROUND BUSHINGS ON ALL FEEDERS ENTERING EXISTING PANELS, WHERE PANELS DO NOT HAVE ASEPARATE GROUND BUS.PART 3: EXECUTION3.1GENERALD.INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, UL LISTING REQUIREMENTS AND ACCEPTED PRACTICES.E.PROVIDE APPROPRIATE FIRESTOPPING MATERIAL AROUND ALL PENETRATIONS THROUGH FIRE-RATED WALLS.3.2COORDINATIONA.TO AVOID CONFLICTS, COORDINATE EXACT PLACEMENT OF ELECTRICAL ITEMS AND ELEVATION OF CONDUIT ROUTES WITH OTHER TRADES PRIOR TO INSTALLATION.ANY CONFLICTS THAT CANNOT BE RESOLVED BETWEEN TRADES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER/ARCHITECT IN WRITING AND RESOLVEDBEFORE PROCEEDING.B.TEMPERATURE CONTROL WIRING AS CALLED FOR OR REFERENCED BY THE ELECTRICAL DRAWINGS AND SPECIFICATIONS WILL BE PROVIDED BY THE ELECTRICALCONTRACTOR. ALL ADDITIONAL WIRING REQUIRED TO PROVIDE A COMPLETE SYSTEM OF TEMPERATURE REGULATION IS TO BE PROVIDED BY THE TEMPERATURECONTROL TRADE. THE TEMPERATURE CONTROL TRADE WILL PROVIDE ALL NECESSARY DRAWINGS AND COORDINATION TO THE ELECTRICAL CONTRACTOR FORDETERMINING PANEL LOCATIONS, CONNECTION POINTS, WIRE COUNTS, ETC.3.3ACCESSIBILITYA.MAINTAIN ACCESSIBILITY TO ALL EQUIPMENT FOR OPERATION, MAINTENANCE AND REPAIR.3.4CUTTING AND PATCHINGA.LAY OUT WORK CAREFULLY IN ADVANCE. WHERE CUTTING CHANNELING, CHASING OR DRILLING OF FLOORS, WALLS, PARTITIONS, CEILINGS OR OTHER SURFACES ISNECESSARY, THE WORK IS TO BE CAREFULLY DONE. ANY DAMAGE TO THE BUILDING, PIPING OR OTHER EQUIPMENT IS TO BE REPAIRED BY SKILLED MECHANICS OF THETRADES INVOLVED AT NO ADDITIONAL COST TO THE OWNER. THIS CONTRACTOR/TRADE WILL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING RELATED TO THEWORK OF THIS DIVISION OF THE SPECIFICATIONS.B.UNLESS OTHERWISE INDICATED IN OTHER DIVISIONS OF THE SPECIFICATIONS, AT NO ADDITIONAL COST TO THE OWNER, REPAINT ALL PATCHED AREAS TO MATCHORIGINAL FINISH WHERE HOLES OR CHASES HAVE BEEN CUT TO RECEIVE ELECTRICAL WORK. REPAINT PATCHED AREAS WITH TWO (2) COATS OF PAINT TO MATCHSURROUNDING AREAS; BLEND AS REQUIRED.C.GIVE ALL FABRICATED STEEL SUPPORTS, HANGERS, BRACKETS, EXPOSED CONDUITS, PANELBOARD BOXES AND PLATFORMS INSTALLED UNDER THIS CONTRACT, TWO(2) COATS OF HIGH GRADE ENAMEL.END OF SECTIONDATE: ALLIANCE ARCHITECTSALL RIGHTS RESERVEDSHEET NO.2026cO'ROURKE'S PATIO ENCLOSURE KITE Realty Group 1044 E. Angela Blvd., Suite 103 South Bend, IN 4661710/7/26E0.2INDIAN A RE GI STEREDSTATE OFPE11100682No.BR A DLEY A. WHITEPROFESSIONAL ENG INEER Q:\Alliance Projects\Kite\O'Rourkes Patio\Drawings\AutoCAD\E0.2 ELECTRICAL SPECIFICATIONS.dwg, 10/7/2026 9:58:17 AM, DWG To PDF Alliance - High Res.pc3 AAAAAAAAAAAAAAAAAABBBBEXTG. PANEL 'MB'120/208V, 3 PH, 4W200 AMP, 42 POLEEXTG. PANEL 'MA'120/208V, 3 PH, 4W600 AMPNEW PANEL 'MB2'NOTE 9NOTE 3EXTG.PANEL 'K'RH-1RH-1RH-1RH-1RH-1RH-1RH-1JJJJJCF-1CF-1NOTE 8NOTE 460AWP60AWP60AWP60AWP60AWP60AWP60AWPTOCONTROLLER'MB2'4'MB2'4TOCONTROLLERTOCONTROLLERTOCONTROLLERNOTE 1'MB2'1'MB2'3TOCONTROLLERTOCONTROLLERTOCONTROLLERTO EXTG. EXTERIOR LIGHTING CIRCUIT FORPOWER AND CONTROL. ALL CONDUIT ANDSURFACE MOUNTED RACEWAY TO BE HIDDEN.+7'-0"A.F.G.+7'-0"A.F.G.+7'-0"A.F.G.+7'-0"A.F.G.NOTE 21.TYPE 'A' LIGHT FIXTURES TO BE PROVIDED BY OTHERS. E.C. TO INSTALL AND WIRE BACK TO SWITCHAND PANEL. (TYPICAL (18) LOC'S).2.(2)#8, #10G, IN 3/4" C. TO RADIANT HEAT CONTROL PANEL.3.EXISTING SPEAKER TO BE RELOCATED TO CLEAR NEW CONSTRUCTION. EXTEND WIRING ASREQUIRED.4.EXISTING EMERGENCY LIGHT TO BE REMOVED. PROVIDE BLANK COVERPLATE AT EXISTING JUNCTIONBOX LOCATION.5.RADIANT HEATER (RH-1) TO BE PROVIDED BY OTHERS. E.C. TO INSTALL AND WIRE BACK TO CONTROLPANEL AND SWITCHES.6.150 AMP FEED TO (4) RELAY CONTROL PANEL. FEED WITH (2)#2/0, #6 G, IN 2" C. ROUTE CONDUITSABOVE ACCESSIBLE CEILING.7.110 AMP FEED TO (3) RELAY CONTROL PANEL. FEED WITH (2)#1, #6 G, IN 1 1/2" C. ROUTE CONDUITSABOVE ACCESSIBLE CEILING.8.RADIANT HEATER RELAY CONTROL PANELS BY OTHERS. ONE (4) RELAY PANEL (RHP-4) AND ONE (3)RELAY PANEL (RHP-3). COORDINATE EXACT LOCATION WITH OWNER PRIOR TO ROUGH-IN. PROVIDECONTROL WIRING FROM CONTROL PANEL TO SWITCH LOCATION AS REQUIRED.9.PROVIDE AND INSTALL NEW SURFACE MOUNTED 120/208V, 3 PH, 4 W, 22KAIC, 24 POLE ELECTRICALPANEL. SQUARE D NQ OR EQUAL. COORDINATE EXACT LOCATION OF PANEL WITH OWNER PRIOR TOINSTALLATION. PROVIDE AND INSTALL 200A/3P CIRCUIT BREAKER IN PANEL 'MA' TO FEED PANEL 'MB2'.FEED WITH (4)#3/0, #6 G, IN 2" C. ROUTE CONDUITS ABOVE ACCESSIBLE CEILING.10.PROVIDE AND INSTALL A SURFACE MOUNTED WEATHERPROOF RECEPTACLE WITH AN IN-USE COVER.COORDINATE EXACT LOCATION WITH OWNER PRIOR TO ROUGH-IN.11.LIGHT SWITCH(ES), CEILING FAN CONTROLLERS, RADIANT HEATER CONTROLS TO BE COORDINATEDAND LOCATED PER OWNER.12.CONDUIT FOR PAGODA FEEDS TO BE LOCATED ABOVE L.I.G. CEILING AND COOLER. BOXES ANDCONDUIT IN PAGODA TO BE WEATHERPROOF OR LIQUIDTITE AS REQUIRED. ALL BOXES ON EXTERIOROF BUILDING TO BE WEATHERPROOF.NOTE 2NOTE 2NOTE 2NOTE 2NOTE 2NOTE 2NOTE 6NOTE 7RHP-3RHP-4TO PNL'MB2'TO PNL'MB2'NOTE 8WPWP'MB2'6'MB2'6DS FCS FCS TCS TCS TCDDDNOTE 11WOMEN'SMEN'SCLRFZRBEERKITCHENOFFICERESTROOMDISHWASHINGSTORAGESTORAGESTAIRSNOTE 12'MB2'4'MB2'4'MB2'4PS-1PS-1PS-1PS-1PS-1NEW PERGOLA STRUCTUREREFER TO PERGOLA DRAWINGSFOR ADDITIONAL INFORMATION.PLANTERPLANTERELECTRICAL PLAN NOTES:VEST.BAR/DININGSCALE: 1/4" =1'-0"ELECTRICAL PLANNORTHE1.1DATE: ALLIANCE ARCHITECTSALL RIGHTS RESERVEDSHEET NO.2026cO'ROURKE'S PATIO ENCLOSURE KITE Realty Group 1044 E. Angela Blvd., Suite 103 South Bend, IN 4661710/7/26INDIAN A RE GI STEREDSTATE OFPE11100682No.BR A DLEY A. WHITEPROFESSIONAL ENG INEER Q:\Alliance Projects\Kite\O'Rourkes Patio\Drawings\AutoCAD\E1.1 ELECTRICAL PLAN.dwg, 10/7/2026 9:58:59 AM, DWG To PDF Alliance - High Res.pc3 Encroachment Permit Application — O'Rourke's Pergola Page 1 of 1 ENCROACHMENT PERMIT APPLICATION October 7, 2026 City of South Bend — Board of Public Works 215 Dr. Martin Luther King Jr. Blvd., Suite 400 South Bend, IN 46601 RE: Encroachment Permit Application O'Rourke's Public House Pergola 1044 East Angela Blvd. South Bend, IN 46617 Dear Members of the Board: On behalf of KRG Eddy Street Commons, LLC (Kite Realty Group), Alliance Architects respectfully submits the enclosed application for an Encroachment Permit and Revocable Permit for a new pergola at O'Rourke's Public House at Eddy Street Commons. The installer is The Smart Pergola, Carmel, Indiana. The pergola is a free-standing structure located adjacent to the existing building and is not structurally connected to it. It is 13'-5½" in height and has a total area of 525 square feet, of which 370 square feet lies within the right-of- way, extending 9'-6" into it. The pergola is bounded by an existing planter wall that was constructed under a previously approved Encroachment Permit. In plan, the pergola does not reduce the area available in the right-of- way beyond that planter wall; it extends the encroachment only in elevation, above the short planter wall. The existing sidewalk is not affected by this structure. A minimum clear width of 5'-0" is maintained on the sidewalk for pedestrian access, and the pergola will not impair the safe and free flow of pedestrian or vehicular traffic. The runoff from the new roof will be discharged into the flanking planters so that ice will not build up on the pedestrian routes around the pergola. The following are enclosed for the Board's review: the completed and signed Encroachment Application, the signed Revocable Permit, photographs of the area and a rendering of the proposed pergola (Attachment A), and the plans and specifications (Sheets G1.0, C1-100, S1, S2, and E0.1–E1.1). Please contact me at (574) 288-2052 or amollison@alliarch.com with any questions. Thank you for your consideration. Sincerely, ALLIANCE ARCHITECTS Andrew J. Mollison, AIA Principal Enclosures cc: Mr. Tony Halsey, KRG Eddy Street Commons, LLC Mr. Ross Atteberry, The Smart Pergola ATTACHMENT A — SITE PHOTOGRAPHS AND RENDERING Encroachment Permit Application O'Rourke's Public House Pergola 1044 East Angela Blvd. South Bend, IN 46617 Artist's rendering of the proposed pergola with vinyl shades drawn. ATTACHMENT A — SITE PHOTOGRAPHS AND RENDERING (continued) Photo 1 — Overall view of the building frontage and existing planter wall. ATTACHMENT A — SITE PHOTOGRAPHS AND RENDERING (continued) Photo 2 — Existing planter wall and sidewalk at the pergola location. ATTACHMENT A — SITE PHOTOGRAPHS AND RENDERING (continued) Photo 3 — Existing planter wall corner and sidewalk.