HomeMy WebLinkAboutEncroachment & Revocable Permit - Verizon Wirelenss October 13, 2026 Matthew Ament Colliers Engineering & Design for Verizon Wireless matt@terraltd.com RE: Encroachment into Public Right-of-Way – 1044 E. Angela Blvd. (eastbound) Dear Matthew: At its October 13, 2026 meeting, the Board of Public Works approved your request for the replacement of streetlight pole with small cell equipment at 1044 E. Angela Blvd. This encroachment was approved subject to the improvements not becoming a safety hazard. Enclosed please find copies of the permit and application. The encroachment will be permitted to remain and continue until such time as the Board of Public Works of the City of South Bend shall determine that such encroachment is in any way impairing or interfering with the highway or with the free and safe flow of traffic thereon. Said encroachment shall not in any way prejudice or preclude the City’s rights with respect to the future use of that portion of the right-of-way. If, at any time, the City of South Bend determines that it is necessary to revoke the encroachment permit, you, or the future property owner will be responsible for any and all costs associated with the removal of the encroachment and returning your property to its pre-existing state. Sincerely, /s/Hillary Horvath Hillary Horvath, Clerk ENCROACHMENT APPLICATION INSTRUCTIONS City of South Bend – Board of Public Works 215 Doctor M.L.K. Jr Blvd; Suite 400 South Bend, IN 46601 Dear Resident or Business: Thank you for your interest in applying for permission to encroach upon the City’s right-of- way. An encroachment occurs when a neighbor builds something on or overhanging another neighbor’s property. Encroachments on City property can occur when a resident or business owner builds a canopy, signage, awnings, brick mailboxes, planters, and more on City streets, sidewalks, or other City property. All encroachments upon the City’s right-of-way must be approved by the Board of Public Works. PROCESS Once your application is received, it will be reviewed by City personnel and presented at a City of South Bend Board of Public Works meeting for approval. Upon approval, a signed copy of your permit and agreement will be emailed or mailed to you. Note: The encroachment review and approval process can take four to six (4-6) weeks, depending on the complexity of the request. Permits may be revoked at any time. APPLICATION CHECKLIST Below is a checklist of items that must be included with your submission: Completed and signed Encroachment Application Photos of the area where the encroachment will take place. Complete description of the encroachment (i.e. canopy, banner, planter, underground utilities, signage, etc.) Plans and Specifications Signature and Legal Name Signed Revocable Permit Completed applications should be mailed or delivered to: City of South Bend – Board of Public Works 215 Doctor M.L.K. Jr Blvd; Suite 400 South Bend, IN 46601 QUESTIONS The City of South Bend looks forward to working with you! If you have any questions, contact City Engineering at 574.235.9251 or PWengineering@southbendin.gov ENCROACHMENT APPLICATION City of South Bend – Board of Public Works 215 Doctor M.L.K. Jr Blvd; Floor 4 South Bend, IN 46601 PROPERTY OWNER INFORMATION: Name of Business/Homeowner: ______________________________________________________________ Address: _______________________________________________________________________________________ City/State/Zip: _________________________________________________________________________________ Phone:______________________________ Email: ____________________________________________________ ENCROACHMENT INFORMATION: Location of Encroachment: ___________________________________________________________________ Encroachment Description: ___________________________________________________________________ CL Road to R/W Line: _________________________________ Size of Encroachment:________________ Distance of R/W: _____________________________________ Amount in R/W: ______________________ INSTALLER'S INFORMATION: Business Name: ________________________________________________________________________________ Address: _______________________________________________________________________________________ City/State/Zip: _________________________________________________________________________________ Phone:______________________________ Email: ____________________________________________________ Signature: ______________________________________________________________________________________ Printed Name: _________________________________________________________________________________ INCLUDE THE FOLLOWING ITEMS WITH YOUR APPLICATION: Photos of the area where encroachment will take place. Plans and Specifications Completed Agreement AFFIRMATION I, the undersigned do hereby certify and affirm that all the information given in this application is accurate and correct. I understand that encroachments must in no way impair the highway or free and safe flow of traffic thereon and may be revoked at any time. Signature of Applicant: Date: Printed Name of Applicant: ____________________________________________________________________ REVOCABLE PERMIT RECOGNITION OF ENCROACHMENT UPON CITY OF SOUTH BEND-CONTROLLED PROPERTY AND PROVISIONS ALLOWING TEMPORARY CONTINUANCE OF SAME Company/Homeowner Name _____________________________________________ , hereafter, the “APPLICANT.” The encroachment will be permitted to remain and continue under the following terms and conditions: 1)Until such time as the BOARD OF PUBLIC WORKS (“BOARD”) of the CITY OF SOUTH BEND (“CITY”) shall determine that such encroachment is in any way impairing or interfering with the highway or with the free and safe flow of traffic thereon; 2)Said encroachment shall not in any way prejudice or preclude the CITY’S rights with respect to the future use of the portion of the right-of-way; 3)The encroachment as it now exists shall in no manner be added to or enlarged in its present scope or dimensions; 4)In the event of change of ownership of the fixture or any other item of personal property which constitutes the aforesaid encroachment, this permit shall become null and void; 5)The CITY shall not be liable to APPLICANT for any damages caused to APPLICANT that arise out of or is incidental to any activity and/or incidences authorized by this permit; 6)In consideration of the granting of this Permit by the BOARD, APPLICANT shall indemnify, hold harmless and defend the CITY from and against any and all actions or causes of action which the CITY may suffer or incur by reason of bodily injury, including death, to any person or persons, or by reason of damage to or destruction of any property, including the loss thereof, arising out of or in any manner connected with any activity and/or incidences authorized by this permit and/or any activities and/or incidences incidental thereto, or which the CITY may sustain or incur in connection with any litigation, investigation, or other expenditures incidental thereto, including any suit instituted by the CITY to enforce the obligation of this agreement of indemnity. It is the intent of the parties hereto that the APPLICANT shall indemnify the CITY under this indemnification clause to the fullest extent permitted by law. This approval shall be binding upon everyone past or present, claiming any interest in and to the aforementioned encroachment. ACCEPTANCE OF TERMS AND CONDITIONS I accept and agree to be bound by all of the terms and conditions of this permit. Submitted By: Signature: Date: BOARD OF PUBLIC WORKS APPROVAL President Member Member Member Member Attest Revised on 9.14.21 DESCRIPTION REVISIONS SHEET NUMBERSHEET TITLEDATE:PROJECT #:CHECKED BY:DRAWN BY:NO.BYDATE A B C ISSUED FOR REVIEW ADD RFDS& UTIL. COOR; ISSUED FOR PERMITTING UPDATED PER LATEST RFDS TO C-BAND ONLY 02/19/26 09/08/26 10/06/26 RC/DK MM/DK DKMDG# 5000971310W ANGELA1044 E ANGELA BLVDSOUTH BEND, IN 46617ACTAZ08/22/25265-0841701 GOLF ROAD, TOWER 2, SUITE 400 ROLLING MEADOWS, IL 60008 PHONE: (847) 619-5397 FAX: (847) 706-7415T-1TITLE SHEETSITE NAME: W ANGELAREGIONAL MAPVICINITY MAPPROJECT INFORMATIONJURISDICTION:OCCUPANCY:ZONING:LATITUDE: 41.692722° / 41° 41' 33.80" N (1A CERTIFICATION)SITE COORDINATES:CITY OF SOUTH BENDUNINHABITED-LONGITUDE: -86.235878° / 86° 14' 09.16" W (1A CERTIFICATION)ELEVATION: ±740' (1A CERTIFICATION)N.T.S.N.T.S.1044 E ANGELA BLVDSOUTH BEND, IN 46617PROJECT TYPEATTACHMENTSREVISIONSHEETDRAWING INDEXSITELOCATIONSITELOCATIONCONSULTANT TEAMCONSTRUCTION:OPERATIONS:APPROVALSRF:REAL ESTATE:EQUIPMENT ENGINEERING:STRUCTURAL:TERRA CONSULTING GROUP600 BUSSE HIGHWAYPARK RIDGE, IL 60068(847) 698-6400PROJECTCONSULTANT:SURVEYOR:POLE DESIGN:SITE AQ.:1POLE SPECIFICATIONS (DWG # A59944)-2LIGHT POLE FOUNDATION DESIGN-L-1SITE SURVEY-PHONE: (847) 619-5397 FAX: (847) 706-7415ROLLING MEADOWS, ILLINOIS 600081701 GOLF ROAD, TOWER 2, SUITE 400T-1 TITLE SHEET CLP-1AERIAL LOCATION & EXHIBIT PHOTOBC-1SITE PLANBANT-1 EXISTING SITE ELEVATIONSAANT-2PROPOSED SITE ELEVATIONSCANT-2APROPOSED SITE DIMENSIONSCANT-3PROPOSED ANTENNA CONFIGURATION CANT-4EQUIPMENT DETAILSCANT-4AMETER BASE INFORMATIONCANT-4BH-FRAME DETAILSCANT-5CABLE DIAGRAMCANT-6FIBER DROP CABLE DETAILSCANT-7FIBER DROP CABLE DETAILSCE-1, E-1AUTILITY ROUTING PLANBE-2UTILITY ROUTING DETAILSCE-2AUTILITY DESIGN DETAILSBE-3GROUNDING PLAN & DETAILSCS-1/S-2STRUCTURAL DETAILSCSP-1SPECIFICATIONSBTC-1/ TC-2TRAFFIC CONTROL PLANAUTILITIES:FUZE PROJECT #:17342460POWER SOURCE ADDRESS:T.B.D.NOTE TO GENERAL CONTRACTOR:ALL WORK MUST CONFORM TO VERIZON WIRELESSCONSTRUCTION INSTALLATION STANDARDS AND ALL APPLICABLECODES AND ORDINANCES. CONTRACTOR SHALL ALSO VERIFYTHE RFDS AGAINST THE PLANS AND POLE DESIGN/STRUCTURAL.CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DESIGNER ANDVERIZON WIRELESS IN WRITING OF ANY DISCREPANCIES BEFOREPROCEEDING WITH THE WORK.MDG LOCATION I.D.: 5000971310APPLICANT:CONSTRUCTION TYPE:REAL ESTATE MANAGER:CONSTRUCTION MANAGER:POLE OWNER:CITY OF SOUTH BENDPOLE NUMBER:N/AVERIZON WIRELESS1701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008POLE INSTALLATION DATE:N/AFIBER: MCI METRO ATS KATHERINE MARTIN (224) 283-795622" x 34" IS FULL SCALE11" X 17" IS HALF SCALECO-LOCATION ON MUNICIPAL LIGHT POLETAREQ YASIN (312) 725-0033EXISTING MUNICIPAL POLE TO BE REMOVED. PROPOSED VERIZONWIRELESS SMALL CELL EQUIPMENT ON REPLACEMENT MUNICIPAL POLE.POWER TO BE DELIVERED VIA UNDERGROUND. FIBER TO BE DELIVEREDVIA UNDERGROUND (BY OTHERS).KNOW WHAT'S BELOW. CALL BEFORE YOU DIG.Call 811, 1-800-382-5544CONTACT INDIANA 811 TWO WORKING DAYSBEFORE STARTING PROJECTTERRA CONSULTING GROUP600 BUSSE HIGHWAYPARK RIDGE, IL 60068(847) 698-6400ASM CONSULTANTS, INC.16 E. WILSON STREETBATAVIA, IL 60510(630) 879-0200ROB LAHRMAN (847) 809-7481VALMONT INDUSTRIES, INC.20805 EATON AVE.FARMINGTON, MN 55024(651) 463-8990POWER: INDIANA MICHIGAN POWER ACCT. # 04359815307 TIMOTHY MARTIN (574) 236-4920 TERRA CONSULTING GROUP600 BUSSE HIGHWAYPARK RIDGE, IL 60068(847) 698-6400NOTE:DRAWING SET FOR MUNICIPAL REVIEWONLY AND NOT FOR CONSTRUCTION. DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415AERIAL LOCATION & EXHIBIT PHOTO LP-11SCALE: N.T.S. AERIAL LOCATION 2 SCALE: N.T.S. EXHIBIT PHOTO OF POLE PROPOSED SMALL CELL INSTALLATION FRONT SIDE SIDE PHOTO OF EXISTING POLE PHOTO OF EXISTING POLE PHOTO OF EXISTING POLESCALE = N.T.S. UGE UGE UGE UGE UGE UGE UGE UGE UGE UGEGAS GAS GAS GAS GASUGTUGTUGTUGT UGT UGT UGT UGT UGT UGT UGEUGE UGE UGE UGEGASGASGAS GAS GAS GAS GAS UGT UGT UGT UGT UGT UGT UGT DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415C-1 SITE PLAN 0 SCALE 1" =22" x 34" PRINT IS THE FULL SCALE FORMAT. ANY SIZE OTHER THAN THAT IS AT REDUCED SCALE. 5'10"20'10'1 SCALE: 1" = 10' SITE PLAN EXISTING BUILDING EXISTING LIGHT POLE TO BE REMOVED AND REPLACED WITH NEW LIGHT POLE IN SAME LOCATION. PROPOSED LESSEE ANTENNA AND EQUIPMENT TO BE INSTALLED ON REPLACEMENT LIGHT POLE. SEE ANT-2 FOR DETAILS. APPROXIMATE LOCATION OF PROPOSED QUAZITE BOX WITH MHT (BY FIBER PROVIDER). KNOW WHAT'S BELOW. CALL BEFORE YOU DIG. Call 811, 1-800-382-5544 CONTACT INDIANA 811 TWO WORKING DAYS BEFORE STARTING PROJECT W ANGELA BLVD - WESTBOUND W ANGELA BLVD - EASTBOUND EXISTING CONCRETE CURB EXISTING GRASS AREA EXISTING CONCRETE SIDEWALK EXISTING BRICK PAVER BORDER EXISTING LANDSCAPE MEDIAN EXISTING CONCRETE PAVEMENT EXISTING STREET LIGHT AND TRAFFIC SIGNAL LIGHT WITH MAST ARM EXISTING BUILDING OVERHANG EXISTING SYMBOLS & UTILITIES LEGEND UNDERGROUND ELECTRIC FENCE LINE UGE UNDERGROUND FIBERUGF UNDERGROUND GAS LINEGAS OHE OHF OHT OVERHEAD ELECTRIC OVERHEAD FIBER OVERHEAD TELCO UTILITY LINE PROPOSED SYMBOLS & UTILITIES LEGEND UNDERGROUND FIBERUGF OVERHEAD FIBEROHF LIGHT POLE UTILITY POLE UNDERGROUND POWERUGE OVERHEAD POWEROHE QUAZITE BOXMETER STORM SEWER LINE SANITARY SEWER LINE WATERMAIN LINE LIGHT POLE UTILITY POLE ELECTRIC PEDESTAL ELECTRIC HANDHOLE ELECTRICAL METER GAS METER SANITARY SEWER MANHOLE OPEN GRATE STORM MANHOLE STORM CURB INLET STORM SEWER MANHOLE WATER VALVE VAULT WATER SERVICE VALVE FIRE HYDRANT SIGN MAILBOX TRANSFORMER PAD COMM. HANDHOLE W/POST MARKER COMMUNICATION PEDESTAL 10"Ø COMM. HANDHOLE COMM. HANDHOLE FOUND 3/4" IRON PIPE FOUND OR SET CUT CROSS BUILDING ASPHALT CONCRETE DECIDUOUS TREE NON-DECIDUOUS TREE UNDERGROUND TELCO UGT NOTE: 1.VERIZON WIRELESS G.C. TO FIELD LOCATE ALL SUBSURFACE UTILITIES PRIOR TO CONSTRUCTION. 2.VERIZON WIRELESS G.C. TO REPAIR ALL GROUND SURFACE DAMAGES FROM CONSTRUCTION BACK TO EXISTING CONDITIONS. Telephone (630) 273-2500 Fax (630) 273-2600 E-MAIL advanced@advct.com Advanced Surveying & Mapping 1 SCALE: 1" = 4' ENLARGED SITE PLAN EXISTING LIGHT POLE TO BE REMOVED AND REPLACED WITH NEW LIGHT POLE IN SAME LOCATION. PROPOSED LESSEE ANTENNA AND EQUIPMENT TO BE INSTALLED ON REPLACEMENT LIGHT POLE. SEE ANT-2 FOR DETAILS. APPROXIMATE LOCATION OF PROPOSED QUAZITE BOX WITH MHT (BY FIBER PROVIDER). EXISTING GRASS AREA APPROXIMATE LOCATION OF PROPOSED QUAZITE BOX FOR POWER ROUTE (BY VERIZON WIRELESS G.C.). APPROXIMATE LOCATION OF PROPOSED QUAZITE BOX FOR POWER ROUTE (BY VERIZON WIRELESS G.C.).±2'-8"EXISTING CONCRETE SIDEWALK EXISTING BRICK PAVER BORDER DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415EXISTING SITE ELEVATIONS ANT-1SCALE: 3/8" = 1'-0" ±1 PROPOSED EAST ELEVATION SCALE: 3/8" = 1'-0" ±2 PROPOSED SOUTH ELEVATION 22" x 34" PRINT IS THE FULL SCALE FORMAT. ANY SIZE OTHER THAN THAT IS AT REDUCED SCALE. 22" x 34" PRINT IS THE FULL SCALE FORMAT. ANY SIZE OTHER THAN THAT IS AT REDUCED SCALE. GRADE EXISTING TOP OF CONCRETE FDN: 0'-8" ± A.G.L. TOP OF DECORATIVE BASE: 4'-0" ± A.G.L. TOP OF LUMINAIRE: 18'-6" ± A.G.L. OVERALL POLE HEIGHT: 20'-0" ± A.G.L. TOP OF BANNER ARM 13'-9" ± A.G.L. TOP OF POLE: 14'-9" ± A.G.L. TOP OF CAP: 15'-1" ± A.G.L. BOTTOM OF BANNER ARM 9'-9" ± A.G.L. GRADE EXISTING TOP OF CONCRETE FDN: 0'-8" ± A.G.L. TOP OF DECORATIVE BASE: 4'-0" ± A.G.L. TOP OF LUMINAIRE: 18'-6" ± A.G.L. OVERALL POLE HEIGHT: 20'-0" ± A.G.L. TOP OF BANNER ARM 13'-9" ± A.G.L. TOP OF POLE: 14'-9" ± A.G.L. TOP OF CAP: 15'-1" ± A.G.L. BOTTOM OF BANNER ARM 9'-9" ± A.G.L. NOTE: THIS DRAWING IS FOR EXHIBIT AND LAYOUT PURPOSES ONLY. ELEVATIONS WERE CREATED OFF OF FIELD MEASUREMENTS BY THE ENGINEER. EXISTING LUMINAIRE TO BE REMOVED AND RELOCATED TO REPLACEMENT POLE EXISTING DECORATIVE METAL LIGHT POLE AND BASE TO BE REMOVED AND REPLACED EXISTING LUMINAIRE SUPPORT ARM TO BE REMOVED AND REPLACED EXISTING FOUNDATION TO BE REMOVED AND REPLACED EXISTING BANNERS AND SUPPORT ARMS TO BE REMOVED AND RELOCATED TO REPLACEMENT POLE EXISTING AUDIO SPEAKER TO BE REMOVED AND RELOCATED TO REPLACEMENT POLE EXISTING LUMINAIRE TO BE REMOVED AND RELOCATED TO REPLACEMENT POLE EXISTING DECORATIVE METAL LIGHT POLE AND BASE TO BE REMOVED AND REPLACED EXISTING LUMINAIRE SUPPORT ARM TO BE REMOVED AND REPLACED EXISTING FOUNDATION TO BE REMOVED AND REPLACED EXISTING BANNERS AND SUPPORT ARMS TO BE REMOVED AND RELOCATED TO REPLACEMENT POLE EXISTING AUDIO SPEAKER TO BE REMOVED AND RELOCATED TO REPLACEMENT POLE DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415PROPOSED SITE ELEVATIONS ANT-2 NOTE: GENERAL CONTRACTOR TO PAINT PROPOSED EQUIPMENT SHERWIN-WILLIAMS B54B00155 BLACK, OR EQUIVALENT. SCALE: 3/8" = 1'-0" ±1 PROPOSED EAST ELEVATION SCALE: 3/8" = 1'-0" ±2 PROPOSED SOUTH ELEVATION 22" x 34" PRINT IS THE FULL SCALE FORMAT. ANY SIZE OTHER THAN THAT IS AT REDUCED SCALE. 22" x 34" PRINT IS THE FULL SCALE FORMAT. ANY SIZE OTHER THAN THAT IS AT REDUCED SCALE. NOTES: 1.FIBER TO BE CLEAN AND TESTED PRIOR TO CONNECTING TO RRUS. 2.GENERAL CONTRACTOR TO INSTALL GROMMETS ON ALL POLE OPENINGS FOR VERIZON EQUIPMENT. 3.THIS DRAWING IS FOR EXHIBIT AND LAYOUT PURPOSES ONLY. PLEASE REFER TO STRUCTURAL REPORTS PREPARED BY VALMONT INDUSTRIES, INC. (POLE) AND TERRA CONSULTING GROUP (FOUNDATION). SEE ELECTRICAL SHEETS FOR PROPOSED UNDERGROUND UTILITY INFORMATION. PROPOSED CONCRETE FOUNDATION (BY VERIZON WIRELESS G.C.). SEE ATTACHMENT SHEET 2 FOR DETAILS.SEE ELECTRICAL SHEETS FOR PROPOSED UNDERGROUND UTILITY INFORMATION. PROPOSED CONCRETE FOUNDATION (BY VERIZON WIRELESS G.C.). SEE ATTACHMENT SHEET 2 FOR DETAILS. PROPOSED #2 GREEN STRANDED COPPER GROUND WIRE ROUTED UP POLE INTERIOR PROPOSED SECONDARY SERVICE CONDUCTORS ROUTED UP POLE TO SQUARE D LOAD CENTER. PROPOSED PREFABRICATED HANDHOLE (TYP.) PROPOSED SQUARE D LOAD CENTER (Q08-16L100RB/CU) TO BE BANDED TO POLE PROPOSED LGX PANEL TO BE BANDED TO POLE PROPOSED DROP CABLES FROM QUAZITE BOX TO FIBER BOX PROPOSED ALUMINUM POLE (BY VERIZON WIRELESS G.C.). SEE ATTACHMENT SHEET 1 FOR DETAILS. PROPOSED C-BAND ANTENNA (ERICSSON AIR 1672 )TO BE INSTALLED ON POLE EXISTING AUDIO SPEAKER REINSTALLED ON REPLACEMENT POLE EXISTING BANNERS AND BANNER ARMS REINSTALLED ON REPLACEMENT POLE EXISTING LUMINAIRE REINSTALLED ON PROPOSED CROOK ARM PROPOSED #2 GREEN STRANDED COPPER GROUND WIRE ROUTED UP POLE INTERIOR PROPOSED SECONDARY SERVICE CONDUCTORS ROUTED UP POLE TO SQUARE D LOAD CENTER. PROPOSED PREFABRICATED HANDHOLE (TYP.) PROPOSED SQUARE D LOAD CENTER (Q08-16L100RB/CU) TO BE BANDED TO POLE PROPOSED LGX PANEL TO BE BANDED TO POLE PROPOSED DROP CABLES FROM QUAZITE BOX TO FIBER BOX PROPOSED ALUMINUM POLE (BY VERIZON WIRELESS G.C.). SEE ATTACHMENT SHEET 1 FOR DETAILS. PROPOSED C-BAND ANTENNA (ERICSSON AIR 1672 )TO BE INSTALLED ON POLE EXISTING AUDIO SPEAKER REINSTALLED ON REPLACEMENT POLE PROPOSED PREFABRICATED FESTOON CASTING, GFCI RECEPTACLE. EXISTING BANNERS AND BANNER ARMS REINSTALLED ON REPLACEMENT POLE EXISTING LUMINAIRE REINSTALLED ON PROPOSED CROOK ARM PROPOSED CROOK ARM (SEE ATTACHMENT SHEET 1) PROPOSED PREFABRICATED FESTOON CASTING, GFCI RECEPTACLE. NOTES: G.C. TO REFER TO RFDS SHEET FOR THE FINAL EQUIPMENT CONFIGURATION AND VERIFY WITH LESSEE PM PRIOR TO CONSTRUCTION REGARDING EQUIPMENT AVAILABILITY. DESCRIPTION REVISIONS SHEET NUMBERSHEET TITLEDATE:PROJECT #:CHECKED BY:DRAWN BY:NO.BYDATE A B C ISSUED FOR REVIEW ADD RFDS& UTIL. COOR; ISSUED FOR PERMITTING UPDATED PER LATEST RFDS TO C-BAND ONLY 02/19/26 09/08/26 10/06/26 RC/DK MM/DK DKMDG# 5000971310W ANGELA1044 E ANGELA BLVDSOUTH BEND, IN 46617ACTAZ08/22/25265-0841701 GOLF ROAD, TOWER 2, SUITE 400 ROLLING MEADOWS, IL 60008 PHONE: (847) 619-5397 FAX: (847) 706-7415PROPOSED SITEDIMENSIONSANT-2ANOTE:GENERAL CONTRACTOR TO PAINTPROPOSED EQUIPMENT SHERWIN-WILLIAMSB54B00155 BLACK, OR EQUIVALENT.SCALE: 3/8" = 1'-0" ±1PROPOSED EAST ELEVATIONSCALE: 3/8" = 1'-0" ±2PROPOSED SOUTH ELEVATION22" x 34" PRINT IS THE FULL SCALEFORMAT. ANY SIZE OTHER THANTHAT IS AT REDUCED SCALE.22" x 34" PRINT IS THE FULL SCALEFORMAT. ANY SIZE OTHER THANTHAT IS AT REDUCED SCALE.NOTES:1.FIBER TO BE CLEAN AND TESTED PRIOR TO CONNECTING TO RRUS.2.GENERAL CONTRACTOR TO INSTALL GROMMETS ON ALL POLEOPENINGS FOR VERIZON EQUIPMENT.3.THIS DRAWING IS FOR EXHIBIT AND LAYOUT PURPOSES ONLY.PLEASE REFER TO STRUCTURAL REPORTS PREPARED BYVALMONT INDUSTRIES, INC. (POLE) AND TERRA CONSULTINGGROUP (FOUNDATION).GRADEEXISTINGBOTTOM OF LOAD CENTER:18'-3" ± A.G.L.℄ OF C-BAND (AIR1672) ANTENNAS:25'-6" ± A.G.L.BOTTOM OF LGX PANEL:16'-6" ± A.G.L.TOP OF POLE:27'-8" ± A.G.L.NOMINAL MOUNTING HEIGHT:18'-5" ± A.G.L.BOTTOM OF BANNER ARM9'-9" ± A.G.L.4'-0"℄ OF FESTOON CASTING, GFCI:12'-10" ± A.G.L.NOMINAL MOUNTING HEIGHT:18'-5" ± A.G.L.TOP OF CONCRETE FDN:0'-8" ± A.G.L.BOTTOM OF LOAD CENTER:18'-3" ± A.G.L.℄ OF C-BAND (AIR1672) ANTENNAS:25'-6" ± A.G.L.BOTTOM OF LGX PANEL:16'-6" ± A.G.L.TOP OF POLE:27'-8" ± A.G.L.BOTTOM OF BANNER ARM9'-9" ± A.G.L.℄ OF FESTOON CASTING, GFCI:12'-10" ± A.G.L.TOP OF CONCRETE FDN:0'-8" ± A.G.L.NOTES:G.C. TO REFER TO RFDS SHEET FOR THE FINAL EQUIPMENTCONFIGURATION AND VERIFY WITH LESSEE PM PRIOR TOCONSTRUCTION REGARDING EQUIPMENT AVAILABILITY. DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415PROPOSED ANTENNA CONFIGURATION ANT-3PROPOSED ANTENNA CONFIGURATION N.T.S.1 RF EMISSIONS REPORT REQUIRED DATE OF REPORT: _________________________ YES NO NOTE: G.C. TO INSTALL ANTENNAS USING CENTERLINE FROM PROPOSED ELEVATIONS SHEET SCALE: N.T.S.2 ANTENNA AZIMUTH SECTOR - ALPHA AZIMUTH 75° SECTOR - BETA AZIMUTH 170° SECTOR - GAMMA AZIMUTH 275° DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415EQUIPMENT DETAILS ANT-4AIR1672 INFORMATION N.T.S. NOTE: G.C. TO APPLY 3M FILM TO NR ANTENNAS TO MATCH COLOR OF POLE. ERICSSON AIR1672 AIR1672 B77D HEIGHT WIDTH DEPTH WEIGHT WO PROTRUDING ITEMS 20.5"7.9"5.7" 26.5 LBSW/ PROTRUDING ITEMS 21.0"8.0"5.9" SIZE AND WEIGHT: 1 SCALE: N.T.S LGX PANEL DETAILS FRONT VIEW SIDE VIEW 10.0"12.0"TOP VIEW ISOMETRIC 12.0"6.0" 10.0" WEIGHT = 20 POUNDS NOTE: 1.LC TO LC BLOCK TO BE INSTALLED IN LGX PANEL. 2.INTERIOR OF LGX PANEL IS FABRICATED BY MEADE ELECTRIC CO. INC. 2 DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415METER BASE INFORMATION ANT-4A NOTES: METER BASE INSPECTION PRIOR TO ENERFIZING SERVICE, CONTACT: SOUTH BEND BUILDING DEPARTMENT 215 S DOCTOR M.L.K. JR BLVD, SOUTH BEND, IN 46601 (574) 235-9554 DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415ANT-4B H-FRAME SCALE: 1/2" = 1'-0" ±2 H-FRAME SOUTH ELEVATION SCALE: 1/2" = 1'-0" ±3 H-FRAME WEST ELEVATION 6'-0" MIN.18" MIN.5'-6"MAX.4'-6' MIN7'-0"GRADE EXISTING GRADE EXISTING PROPOSED UNDERGROUND SECONDARY SERVICE PROPOSED STUB UP CONDUIT PROPOSED UNDERGROUND SECONDARY SERVICE TO LOAD CENTER ON THE SUBJECT POLE LOCATED ON E ANGELA BLVD 8'-0" PROPOSED GROUND ROD (SEE SHEET E-3 FOR GROUNDING DETAILS) PROPOSED GROUND WIRE (SEE SHEET E-3 FOR GROUNDING DETAILS) PROPOSED UNDERGROUND SECONDARY SERVICE TO SC_EDDY_COMMON_NAPOLEON SITE (LOCATED AT ADDRESS: 1145 N EDDY ST. SOUTH BEND, IN 46617) 8'-0" PROPOSED GROUND ROD (SEE SHEET E-3 FOR GROUNDING DETAILS) PROPOSED GROUND WIRE (SEE SHEET E-3 FOR GROUNDING DETAILS) PROPOSED UNDERGROUND SECONDARY SERVICE TO LOAD CENTER ON THE SUBJECT POLE LOCATED ON E ANGELA BLVD1'-6"4'-6"SCALE: 1/2" = 1'-0" ±1 H-FRAME PLAN VIEW 5'-0" MAX APPROVED METER MAIN, 4 TERMINAL/ RINGLESS, LEVEL BYPASS, 2 POSITIONS, 120/240V, 1Ø. MILBANK #U5972-XT-LIS-BLG APPROVED METER MAIN, 4 TERMINAL/ RINGLESS, LEVEL BYPASS, 2 POSITIONS, 120/240V, 1Ø. MILBANK #U5972-XT-LIS-BLG 4 SCALE: N.T.S H-FRAME FOUNDATION DETAIL GRADE 3' MIN4.5'6"1.5' 5' MAX. Ø3" STD. GALVANIZED PIPE 12 GA UNISTRUT (TYP.) SPACED AS NEEDED PER MOUNTING PATTERN (P1000 "SL" SERIES OR APPROVED EQUAL) Ø1/2" U-BOLT FOR Ø3" STD. PIPE (TYP.) CONCRETE PIER (TYP.) (4) #5 BARS EQUALLY SPACED (TYP.) #3 TIES @ 12" O.C. (TYP.) VIRGIN SOIL OR COMPACTED BACKFILL WITH MINIMUM BEARING CAPACITY OD 2,000 PSF (TYP.) CONCRETE STRENGTH: f 'c = 3,000 PSI Rebar: Grade 60 SCH 40 PVC CONDUIT PVC TO PVC ADAPTOR SCH 80 PVC CONDUIT (36" RADIUS) PVC CAP 6" MIN.CONTRACTOR SHALL FURNISH AND INSTALL ENGRAVED PLASTIC LABELS "VERIZON WIRELESS, W ANGELA" & "VERIZON WIRELESS, EDDY STREET" AND PLACE ABOVE RESPECTIVE ELECTRIC METER SOCKETS DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415CABLE DIAGRAM ANT-5 100A LOAD CENTER W/ DISCONNECT AIR1672 #2 AIR1672 #1AIR1672 #3 BBU SCALE: N.T.S CABLE DIAGRAM1 T-SFP28 25G 191.4-196.1 THz I-TEMP FIBER STRAND NEW SET OF (3) CONDUCTORS (TYP. OF 1 PER NEW ANTENNA) NOTES: G.C. TO REFER TO RFDS SHEET FOR THE FINAL EQUIPMENT CONFIGURATION AND VERIFY WITH LESSEE PM PRIOR TO CONSTRUCTION REGARDING EQUIPMENT AVAILABILITY. NOTES: ALL CABLES TO BE OUTDOOR RATED. METER BiDi CPRI CONNECTION RDH10281/1 (TYP.) BiDi CPRI CONNECTION RDH10281/2 (TYP.) DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415FIBER DROP CABLE DETAILS ANT-6 COMMSCOPE PART: MHT - 06H200U - A0500F PORT POSITION FIBER PAIR FIBER STRAND BAND 1 1 1/2 28/39 GHz / CBRS 2 2 3/4 SPARE 3 3 5/6 SPARE 4 4 7/8 SPARE 5 NOT USED NOT USED NOT USED 6 NOT USED NOT USED NOT USED DIMENSIONS Cable Length 152.40 m | 500.00 ft Depth 89.00mm | 3.50 in Height 298.00 mm | 11.73 in Outer Cable Dimensions 4.5 x 8.1 mm (1.78 x 0.32 in) Weight, without cable 0.99 kg | 2.18 lb Width 130.30 mm | 5.13 in DESCRIPTION LENGTH METERS (FEET) PART NUMBER VERIZON MMID VERIZON SSID TALLEY ITEM#GRAYBAR SKU# 2-Fiber Singlemode Hardened Drop Cable HMFOC to LC Duplex Connector 1 (3)DFJ-2S320-1M 10819842 11353467 ANDDFJ-2S320-1M 26366619 3 (10)DFJ-2S320-3M 10819816 11353468 ANDDFJ-2S320-3M 26411796 4 (13)DFJ-2S320-4M 10819815 11353469 ANDDFJ-2S320-4M 26146138 5 (16)DFJ-2S320-5M 10819817 11353470 ANDDFJ-2S320-5M 26411797 10 (33)DFJ-2S320-10M 10819809 11353471 ANDDFJ-2S320-10M 26049847 15 (49)DFJ-2S320-15M 10829412 11365573 ANDDFJ-2S320-15M 26146139 20 (66)DFJ-2S320-20M 10819810 11353472 ANDDFJ-2S320-20M 26146137 25 (82)DFJ-2S320-25M 10819811 11353473 ANDDFJ-2S320-25M 26411795 30 (98)DFJ-2S320-30M 10819830 11353474 ANDDFJ-2S320-30M 26056017 50 (164)DFJ-2S320-50M 10819831 11353475 ANDDFJ-2S320-50M 26146140 Full AXS Weatherproofing Shroud Moisture seal for fiber connections -FA-FWS-E-250 ***--ANDFA-FWS-E-250 25762741 MECHANICAL CHARACTERISTICS ORDERING INFORMATION TALLEY ITEM#GRAYBAR SKU# TOTAL LENGTH (TIP-TO-TIP)WEIGHT INDIVIDUAL BULK*INDIVIDUAL INDIVIDUAL 4-PORT TERMINAL 443 mm (1.45 ft)0.21 kg (7.4 ounces)MPF-0448M1R43F-P MPF-0448M1R43F -25851266 8-PORT TERMINAL 643 mm (2.1 ft)0.21 kg (7.4 ounces)MPF-0848M1R43F-P MPF-0848M1R43F -25851267 12-PORT TERMINAL 843 mm (2.8 ft)0.21 kg (7.4 ounces)MPF-1248M1R43F-P MPF-1248M1R43F -25851268 OPTICAL CHARACTERISTICS INSERTION LOSS, MAXIMUM REFLECTANCE, MAXIMUM OPTITAP®SINGLE-FIBER CONNECTOR 0.40 dB ≤ 65 dB OPTITIP®MULTI-FIBER CONNECTOR 0.62 dB ≤ 65 dB * BULK ORDER QUANTITIES 4-PORT TERMINAL BULK ORDERS HAVE 8 UNITS 8-PORT TERMINAL BULK ORDERS HAVE 6 UNITS 12-PORT TERMINAL BULK ORDERS HAVE 6 UNITS PRODUCT CLASSIFICATION Product Type Wireless Fiber Cable Assemblies Product Series FiberFeed FHBDW GENERAL SPECIFICATIONS Connector A, quantity 1 Connector B, quantity 2 Interface, Connector A Hardened SC/APC (Straight) Interface, Connector B LC Duplex (Straight) Cable Black Jacket Rating Outdoor Total Fibers, quantity (2) G.657.A2 Fibers OPTICAL SPECIFICATIONS Fiber Mode Singlemode Fiber Type G.657.A2 Insertion Loss, Typical (measured at 1310 and 1550 nm)0.75dB DESCRIPTION LENGTH METERS (FEET) PART NUMBER TALLEY ITEM#GRAYBAR SKU# 2-Fiber Singlemode Drop Assembly (2) Hardened SC/APC to (1) LC Duplex 3.05 m (10.0')FHBDW-H2Q22-0010F ANDFHBDW-H2Q22-001 0F 26411798 10.67 m (35.0')FHBDW-H2Q22-0035F ANDFHBDW-H2Q22-003 5F 26411799 15.24 m (50.0')FHBDW-H2Q22-0050F ANDFHBDW-H2Q22-005 0F 26411800 22.86 m (75.0')FHBDW-H2Q22-0075F ANDFHBDW-H2Q22-007 5F 26550098 30.48 m (100.0')FHBDW-H2Q22-0100F ANDFHBDW-H2Q22-010 0F 26411801 45.72 m (150.0')FHBDW-H2Q22-0150F ANDFHBDW-H2Q22-015 0F 26411802 76.20 m (250.0')FHBDW-H2Q22-0250F ANDFHBDW-H2Q22-025 0F 26550191 6 4 2 5 3 1 N.T.S. COMMOSCOPE MHT SPECIFICATIONS & PORT ASSIGNMENTS1 NOTE: G.C. TO PROVIDE CABLE PROTECTION FOR EXPOSED FIBER CABLES ONLY N.T.S. CORNING OPTISHEATH MULTIPORT FLEX TERMINAL & ORDERING CHART3 N.T.S. COMMOSCOPE HEKIAX MHT DROP CABLE ORDERING CHART2 N.T.S. COMMOSCOPE HELIAX FLEX TERMINAL DROP CABLE SPECIFICATIONS & ORDERING CHART4 5.13" 3.5"11.73" DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415FIBER DROP CABLE DETAILS ANT-7 DESCRIPTION PART NUMBER TALLEY ITEM#GRAYBAR SKU# ConcealFab PIM Shield Snap-in Adapter 900860-10 CFB900860-10 26548533 ConcealFab PIM Shield Channel Runner Kit 900360-10 CFB900360-10 26399940 ConcealFab PIM Shield Plastic Snap-In, 4-7mm (3/16 - 1/4 in.)PSPS-0407-10 CFBPSPS-0407-10 26548536 ConcealFab PIM Shield Plastic Snap-In, 7-10mm (3/8 in.)PSPS-0710-10 CFBPSPS-0710-10 26548537 ConcealFab PIM Shield Plastic Snap-In, 10-14mm (1/2 in.)PSPS-1014-10 CFBPSPS-1014-10 26548538 ConcealFab PIM Shield Plastic Snap-In, 14-17mm (5/8 in.)PSPS-1417-10 CFBPSPS-1417-10 26548539 ConcealFab PIM Shield Cable Strap, Acetal (16 in.)900443-16-50 CFB900443-16-50 26399943 ConcealFab PIM Shield Cable Strap, Acetal (27 in.)900443-27-25 CFB900443-27-25 26399944 ConcealFab PIM Shield Snap-In Adapter (1 pos.)900939-10 -26552151 ConcealFab PIM Shield Snap-In Adapter Cube (5 pos.)900945-10 CFB900945-10 26552152 ConcealFab PIM Shield Hybrid Snap-In, 13-19mm (1/2 - 5/8 in.)PSHS-1319-10 CFBPSHS-1319-10 26376988 ConcealFab PIM Shield Hybrid Snap-In, 26-30mm (1 in.)PSHS-2630-10 CFBPSHS-2630-10 26376989 ConcealFab PIM Shield Hybrid Snap-In, 36-42mm (1-1/2 to 1-5/8 in.)PSHS-3642-10 CFBPSHS-3642-10 26548534 ConcealFab PIM Shield Hybrid Snap-In, 48-52mm (1-7/8 to 2 in.)PSHS-4852-10 CFBPSHS-4852-10 26548535 ConcealFab PIM Shield Cable Cushion, 4.5-6.5mm (3/16 - 1/4 in.) Installed in Hybrid Snap-In PSHS-1319-10 PSCC-1001-10 CFBPSCC-1001-10 26399947 ConcealFab PIM Shield Cable Cushion, 6.6-8.5mm (1/4 - 5/16 in.); Installed in Hybrid Snap-In PSHS-1319-10 PSCC-1002-10 CFBPSCC-1002-10 26399948 ConcealFab PIM Shield Cable Cushion, 8.6-10.5mm (5/16 in.); Installed in Hybrid Snap-In PSHS-1319-10 PSCC-1003-10 CFBPSCC-1003-10 26399949 ConcealFab PIM Shield Cable Cushion, 10.6-12.5mm (7/16 - 1/2 in.); Installed in Hybrid Snap-In PSHS-2630-10 PSCC-2001-10 CFBPSCC-2001-10 26376990 ConcealFab PIM Shield Cable Cushion, 12.6-15.5mm (1/2 - 5/8 in.); Installed in Hybrid Snap-In PSHS-2630-10 PSCC-2002-10 -26552171 ConcealFab PIM Shield Cable Cushion, 15.6-17.5mm (5/8 - 11/16 in.); Installed in Hybrid Snap-In PSHS-2630-10 PSCC-2003-10 -26552172 ConcealFab PIM Shield Cable Cushion, 19.6-30.3mm (7/8 to 1-3/16 in.); Installed in Hybrid Snap-In PSHS-4852-10 PSCC-4001-10 -26552173 ConcealFab PIM Shield Multi-Function Cable Support Base 901043-10 CFB901043-10 26548019 ConcealFab PIM Shield Multi-Function Snap-In Adapter 901044-10 CFB901044-10 26548531 ConcealFab PIM Shield Multi-Function Snap-in Adapter 901045-10 CFB901045-10 26548532 ConcealFab PIM Shield Cable Support Rail 900363-6 CFB900363-6 26399942 Commscope SnapTak Hanger, 7.1 -10mm (5/16 - 3/8 in.)SSH-710 ANDSSH-710 26097980 Commscope SnapTak Hanger, 4-7mm (3/16 - 1/4 in.)SSH-47 ANDSSH-47 26097979 Commscope SnapTak Hanger, 10.1-14mm (7/16 - 1/2 in.)SSH-1014 ANDSSH-1014 26097981 Commscope SnapTak Hanger, 14.1-16mm (9/16 - 5/8 in.)SSH-1416 ANDSSH-1416 26097982 Commscope Snap-in Hanger Adapter SA-3C ANDSA-3C 26506170 Commscope PIM-Free Snap-in Hanger Adapter SA-1C ANDSA-1C 26159522 Commscope PIM-Free Multifunction Adapter for SnapTak Hangers SA-1TR ANDSA-1TR 26380916 Commscope PIM free isolator for SnapStak cable hangers SA-ISO ANDSA-ISO 26513146 Commscope PIM free angle adapter UA-3C ANDUA-3C 26517586 Commscope SnapWrap Cable Management (Pkg of 10 or 100) SWH-200-10 SWH-200-100 ANDSWH-200-10 NO GB ID Commscope Heliax Excess Discrete Fiber Coiling Reel (accommodates 16ft of excess 7mm (1/4 in.) fiber; stackable)FBR-COIL-S ANDFBR-COIL-S 26550277 Commscope 2-Run Fiber Hanger Block, 5-7mm (1/4 in.)BHD-4MM ANDBHD-4MM 25960110 900860-10 (FOR POLE/WALL MOUNT) SSH-710 (SNAPTAK HANGER) SSH-47 (SNAPTAK HANGER) 900360-10 (FOR RAIL MOUNT) PSPS-XXXX-10 (FOR CABLE SUPPORT MOUNT) 900443-XX-XX (FOR CABLE SUPPORT MOUNT) 900939-10 (SUPPORTS SNAP-IN CABLE HANGERS) 900945-10 (SUPPORTS SNAP-IN CABLE HANGERS) PSHS-XXXX-10 (FOR CABLE SUPPORT MOUNT) PSCC-XXXX-10 (FOR HYBRID SNAP-IN) SSH-1416 (SNAPTAK HANGER) SA-3C (SNAP-IN HANGER ADAPTER) SSH-1014 (SNAPTAK HANGER) SA-1TR (SNAP-IN HANGER ADAPTER) SWH-200-XX (SNAPWRAP CABLE MANAGEMENT STRAP) SA-ISO (ISOLATOR FOR SNAPSTAK CABLE HANGERS) SA-1C (SNAP-IN HANGER ADAPTER) FBR-COIL-S (FIBER COILING REEL) 901045-10 (SUPPORTS HYBRID SNAP-IN HANGERS) 901043-10 (SUPPORTS THREADED ROD) 901044-10 (SUPPORTS SNAP-IN STYLE CABLE HANGERS) BHD-4MM (2-RUN FIBER HANGER BLOCK) 900363-6 (SUPPORTS CHANNEL RUNNER KITS) N.T.S. PIM MITIGATION MOUNTING HARDWARE & ORDERING CHART1 NOTE: 1.G.C. TO ATTACH GHOST TERMINAL TO HANDLE WALL. 2.DO NOT LEAVE FIBER TERMINAL ON THE GROUND UNATTACHED. UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGEGAS GAS GAS GAS GAS GAS GAS GAS UGT UGT UGT UGT UGT UGT UGT UGT UGT UGEUGE UGE UGE UGE UGE UGE UGEUGEUGEUGEUGE UGE UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEDESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415E-1 ROUTING PLAN UTILITYSCALE = N.T.S.SCALE = 1" = 4'SEE SHEET E-1, DETAIL-2 FOR ENLARGED UTILITY ROUTING PLAN FA FBVF SCALE: 1" = 6'2 ENLARGED UTILITY ROUTING PLAN NOTE: 1.VERIZON WIRELESS G.C. TO FIELD LOCATE ALL SUBSURFACE UTILITIES PRIOR TO CONSTRUCTION. 2.VERIZON WIRELESS G.C. TO REPAIR ALL GROUND SURFACE DAMAGES FROM CONSTRUCTION BACK TO EXISTING CONDITIONS. 3.FIBER ROUTE IS PRELIMINARY. SEE FIBER PROVIDER DRAWINGS FOR FINAL FIBER SURVEY. SCALE: N.T.S.4 PHOTO OF EXISTING POWER SOURCE SCALE: 1" = 6'3 ENLARGED UTILITY ROUTING PLAN EXISTING GRASS AREA EXISTING GRASS AREA W ANGELA BLVD NAPOLEON STREET SCALE: N.T.S.1 UTILITY ROUTING PLAN NOTE: POWER PLAN PARTIALLY CREATED OFF OF AERIAL IMAGE AS BOUNDARY SURVEY DID NOT INCORPORATE THE POWER SOURCE LOCATION. VA PA VB VC VERIZON WIRELESS - UTILITY KEYED NOTES: VA VERIZON WIRELESS G.C. TO INSTALL (1) 3" SCH40 CONDUIT FROM METER BASE STUBED UP AT BASE OF EXISTING UTILITY POLE WITH LONG SWEEP ELBOW. (±10' ). G.C. TO INSTALL ONLY AFTER ALL THE MAKE READY WORK IS COMPLETE. VERIZON WIRELESS G.C. TO INSTALL METER BASE ON PROPOSED H-FRAME. SEE METER DIAGRAM ON SHEET ANT-4A. VERIZON WIRELESS G.C. TO INSTALL CONDUIT AND CONDUCTORS FROM METER TO QUAZITE BOX (±830'). SEE SINGLE-LINE DIAGRAM ON SHEET E-2 FOR DETAILS. VERIZON WIRELESS G.C. TO INSTALL QUAZITE BOX NEAR BASE OF POLE TO REDUCE CONDUIT SIZE. SEE SINGLE-LINE DIAGRAM ON SHEET E-2 FOR DETAILS. VERIZON WIRELESS G.C. TO INSTALL CONDUIT FROM QUAZITE TO BASE OF POLE, AND PULL CONDUCTORS TO LOAD CENTER (±30'). SEE SINGLE-LINE DIAGRAM ON SHEET E-2 FOR DETAILS. VERIZON WIRELESS G.C. TO PULL DROP CABLES FROM PROPOSED QUAZITE BOX TO FIBER BOX (±25'). VB VC VD VE VF POWER PROVIDER - POWER KEYED NOTES: PA POWER PROVIDER TO MAKE CONNECTION TO POWER SOURCE FIBER PROVIDER - FIBER KEYED NOTES: FA APPROXIMATE LOCATION OF PROPOSED QUAZITE BOX WITH MHT (BY FIBER PROVIDER). PROPOSED 2" SCH 40 CONDUIT FOR FIBER OPTIC CABLE FROM PROPOSED QUAZITE BOX, THROUGH FOUNDATION TO BASE OF POLE (BY FIBER PROVIDER) FB MATCH LINE "A" SEE SHEET E-1A DETAIL 1 & 2 SEE SHEET E-1, DETAIL-3 FOR ENLARGED UTILITY ROUTING PLAN EXISTING LIGHT POLE TO BE REMOVED AND REPLACED WITH NEW LIGHT POLE IN SAME LOCATION. PROPOSED LESSEE ANTENNA AND EQUIPMENT TO BE INSTALLED ON REPLACEMENT LIGHT POLE. SEE ANT-2 FOR DETAILS. VCVD VE SCALE = 1" = 4'PA EXISTING LIGHT POLE TO BE REMOVED AND REPLACED WITH NEW LIGHT POLE IN SAME LOCATION. PROPOSED LESSEE ANTENNA AND EQUIPMENT TO BE INSTALLED ON REPLACEMENT LIGHT POLE. SEE ANT-2 FOR DETAILS. PA KNOW WHAT'S BELOW. CALL BEFORE YOU DIG. Call 811, 1-800-382-5544 CONTACT INDIANA 811 TWO WORKING DAYS BEFORE STARTING PROJECTN EDDY STW ANGELA BLVD VC NAPOLEON ST UTILITY PROVIDER INDIANA MICHIGAB POWER REPRESENTATIVE TOTAL DISTANCE TO POWER SOURCE INDIANA MICHIGAN POWER TIMOTHY MARTIN (574) 236-4920 ±830'N EDDY STEXISTING R.O.W. LINE UGE UGE UGE GAS GASUGTUGTUGTUGT UGT UGE UGE UGE UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEGASGASGASUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEDESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415E-1A ROUTING PLAN UTILITY SCALE: N.T.S.1 ENLARGED UTILITY ROUTING PLAN VERIZON WIRELESS - UTILITY KEYED NOTES: VA VERIZON WIRELESS G.C. TO INSTALL (1) 3" SCH40 CONDUIT FROM METER BASE STUBED UP AT BASE OF EXISTING UTILITY POLE WITH LONG SWEEP ELBOW. (±10' ). G.C. TO INSTALL ONLY AFTER ALL THE MAKE READY WORK IS COMPLETE. VERIZON WIRELESS G.C. TO INSTALL METER BASE ON PROPOSED H-FRAME. SEE METER DIAGRAM ON SHEET ANT-4A. VERIZON WIRELESS G.C. TO INSTALL CONDUIT AND CONDUCTORS FROM METER TO QUAZITE BOX (±830'). SEE SINGLE-LINE DIAGRAM ON SHEET E-2 FOR DETAILS. VERIZON WIRELESS G.C. TO INSTALL QUAZITE BOX NEAR BASE OF POLE TO REDUCE CONDUIT SIZE. SEE SINGLE-LINE DIAGRAM ON SHEET E-2 FOR DETAILS. VERIZON WIRELESS G.C. TO INSTALL CONDUIT FROM QUAZITE TO BASE OF POLE, AND PULL CONDUCTORS TO LOAD CENTER (±30'). SEE SINGLE-LINE DIAGRAM ON SHEET E-2 FOR DETAILS. VERIZON WIRELESS G.C. TO PULL DROP CABLES FROM PROPOSED QUAZITE BOX TO FIBER BOX (±25'). VB VC VD VE VF POWER PROVIDER - POWER KEYED NOTES: PA POWER PROVIDER TO MAKE CONNECTION TO POWER SOURCE FIBER PROVIDER - FIBER KEYED NOTES: FA APPROXIMATE LOCATION OF PROPOSED QUAZITE BOX WITH MHT (BY FIBER PROVIDER). PROPOSED 2" SCH 40 CONDUIT FOR FIBER OPTIC CABLE FROM PROPOSED QUAZITE BOX, THROUGH FOUNDATION TO BASE OF POLE (BY FIBER PROVIDER) FB SCALE: N.T.S.2 ENLARGED UTILITY ROUTING PLAN NOTE: 1.VERIZON WIRELESS G.C. TO FIELD LOCATE ALL SUBSURFACE UTILITIES PRIOR TO CONSTRUCTION. 2.VERIZON WIRELESS G.C. TO REPAIR ALL GROUND SURFACE DAMAGES FROM CONSTRUCTION BACK TO EXISTING CONDITIONS. 3.FIBER ROUTE IS PRELIMINARY. SEE FIBER PROVIDER DRAWINGS FOR FINAL FIBER SURVEY. NOTE: POWER PLAN PARTIALLY CREATED OFF OF AERIAL IMAGE AS BOUNDARY SURVEY DID NOT INCORPORATE THE POWER SOURCE LOCATION. KNOW WHAT'S BELOW. CALL BEFORE YOU DIG. Call 811, 1-800-382-5544 CONTACT INDIANA 811 TWO WORKING DAYS BEFORE STARTING PROJECT W ANGELA BLVD N EDDY STN EDDY STNAPOLEON ST EXISTING SYMBOLS & UTILITIES LEGEND UNDERGROUND ELECTRIC FENCE LINE UGE UNDERGROUND FIBERUGF UNDERGROUND GAS LINEGAS OHE OHF OHT OVERHEAD ELECTRIC OVERHEAD FIBER OVERHEAD TELCO UTILITY LINE PROPOSED SYMBOLS & UTILITIES LEGEND UNDERGROUND FIBERUGF OVERHEAD FIBEROHF LIGHT POLE UTILITY POLE UNDERGROUND POWERUGE OVERHEAD POWEROHE QUAZITE BOXMETER STORM SEWER LINE SANITARY SEWER LINE WATERMAIN LINE LIGHT POLE UTILITY POLE ELECTRIC PEDESTAL ELECTRIC HANDHOLE ELECTRICAL METER GAS METER SANITARY SEWER MANHOLE OPEN GRATE STORM MANHOLE STORM CURB INLET STORM SEWER MANHOLE WATER VALVE VAULT WATER SERVICE VALVE FIRE HYDRANT SIGN MAILBOX TRANSFORMER PAD COMM. HANDHOLE W/POST MARKER COMMUNICATION PEDESTAL 10"Ø COMM. HANDHOLE COMM. HANDHOLE FOUND 3/4" IRON PIPE FOUND OR SET CUT CROSS BUILDING ASPHALT CONCRETE DECIDUOUS TREE NON-DECIDUOUS TREE UNDERGROUND TELCO UGTSCALE = N.T.S.SCALE = N.T.S.MATCH LINE "A" SEE SHEET E-1A DETAIL 2 MATCH LINE "A" SEE SHEET E-1A DETAIL 1 EXISTING R.O.W. LINE EXISTING BUILDING EXISTING CONCRETE SIDEWALK EXISTING LANDSCAPING AREA (TYP.) EXISTING HANDHOLES (TYP.) EXISTING BRICK PAVER AREA (TYP.) VC VC SEE SHEET E-1, DETAIL-3 FOR ENLARGED UTILITY ROUTING PLAN PA EXISTING R.O.W. LINE EXISTING EASEMENT EXISTING BUILDING EXISTING R.O.W. LINE VC EXISTING R.O.W. LINE EXISTING BUILDING EXISTING LANDSCAPING AREA (TYP.) EXISTING BRICK PAVER AREA (TYP.) EXISTING PARKING AREA (TYP.) SEE SHEET E-1, DETAIL-2 FOR ENLARGED UTILITY ROUTING PLAN EXISTING LIGHT POLE TO BE REMOVED AND REPLACED WITH NEW LIGHT POLE IN SAME LOCATION. PROPOSED LESSEE ANTENNA AND EQUIPMENT TO BE INSTALLED ON REPLACEMENT LIGHT POLE. SEE ANT-2 FOR DETAILS. DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415E-2 ROUTING DETAILS UTILITY 2 AMERICAN NATIONAL STANDARDS INSTITUTE AMERICAN SOCIETY FOR TESTING MATERIALS NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NATIONAL FIRE PROTECTION ASSOCIATION INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS A.N.S.I. UNDERWRITERS LABORATORIES, INC. N.F.P.A. N.E.M.A. I.E.E.E. A.S.T.M. U.L. NATIONAL ELECTRIC CODEN.E.C. UTILITY NOTES: THESE NOTES AND ACCOMPANYING DRAWINGS COMPLEMENT THE PROVISIONS AND INSTALLATIONS BY THE ELECTRICAL CONTRACTOR, OF ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED TO INSTALL THE ELECTRICAL WORK COMPLETE IN CONNECTION WITH THIS VERIZON WIRELESS SITE AND SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. THE PROVISIONS, INSTALLATION, AND CONNECTION OF A GROUNDING ELECTRODE SYSTEM COMPLETE WITH SECONDARY GROUNDING, AND CONNECTIONS TO THE INCOMING ELECTRICAL DISTRIBUTION EQUIPMENT. 2. THE PROVISION AND INSTALLATION OF AN OVERHEAD ELECTRICAL SERVICE OR UNDERGROUND ELECTRICAL SERVICE AND ALL ASSOCIATED WIRE AND CONDUIT AS REQUIRED AND/OR INDICATED ON PLANS. 3. THE PROVISION, INSTALLATION OF CONDUIT AND CONNECTIONS FOR LOCAL FIBER SERVICE. 4. THE FURNISHING AND INSTALLATION OF THE ELECTRICAL SERVICE ENTRANCE CONDUCTORS, CONDUITS, METER SOCKET, AND CONNECTIONS TO THE SERVICE EQUIPMENT. 5. TWO INCH (2") AND THREE INCH (3") DIAMETER PVC CONDUITS SCHEDULE 40. 6. ALL PVC CONDUITS SHOULD BE LEFT WITH NYLON PULL CORD FOR FUTURE USE. 7. EXCAVATION, TRENCHING, AND BACKFILLING FOR CONDUIT(S), CABLE(S), AND EXTERNAL GROUNDING SYSTEM. WORK INCLUDES: CODES, PERMITS, AND FEES: 1. ALL REQUIRED PERMITS, LICENSES, INSPECTIONS AND APPROVALS SHALL BE SECURED AND ALL FEES FOR SAME PAID BY CONTRACTOR. 2. THE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CODES: STATE, LOCAL AND NATIONAL, AND THE DESIGN, PERFORMANCE CHARACTERISTICS AND METHODS OF CONSTRUCTION OF ALL ITEMS AND EQUIPMENT SHALL BE IN ACCORDANCE WITH THE LATEST ISSUE OF THE VARIOUS APPLICABLE STANDARD SPECIFICATIONS OF THE FOLLOWING AUTHORITIES: RACEWAYS AND WIRING: 1. WIRING OF EVERY KIND MUST BE INSTALLED IN CONDUIT, UNLESS NOTED OTHERWISE, OR AS APPROVED BY THE ENGINEER. 2. UNLESS OTHERWISE SPECIFIED, ALL WIRING SHALL BE COPPER (CU) TYPE THWN, SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. 4. RACEWAYS SHALL BE GALVANIZED STEEL, SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, UNLESS OTHERWISE NOTED. ALL RACEWAYS SHALL BE APPROVED FOR THE INSTALLATION. 5. PULL OR JUNCTION BOXES SHALL BE PROVIDED AS REQUIRED TO FACILITATE INSTALLATION OF RACEWAYS AND WIRING. PROVIDE JUNCTION AND PULLBOXES FOR CONDUIT RUNS WITH MORE THAN (360) DEGREES OF BENDS. 6. PROVIDE A COMPLETE RACEWAY AND WIRING INSTALLATION, PERMANENTLY AND EFFECTIVELY GROUNDED IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE AND LOCAL CODES. 7. ALL STEEL CONDUIT SHALL BE BONDED AT BOTH ENDS WITH GROUNDING BUSHING. GENERAL NOTES: SEE DETAILS AND SCHEDULES ON DRAWINGS AND SPECIFICATIONS FOR MEANING OF ABBREVIATIONS AND ADDITIONAL REQUIREMENTS AND INFORMATION. CHECK ARCHITECTURAL, STRUCTURAL AND OTHER MECHANICAL AND ELECTRICAL DRAWINGS FOR SCALE, SPACE LIMITATIONS, COORDINATION, AND ADDITIONAL INFORMATION, ETC. REPORT ANY DISCREPANCIES, CONFLICTS, ETC. TO ENGINEER BEFORE SUBMITTING BID. ALL EQUIPMENT FURNISHED BY OTHERS (FBO) SHALL BE PROVIDED WITH PROPER MOTOR STARTERS, DISCONNECTS, CONTROLS, ETC. BY THE ELECTRICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. THE ELECTRICAL CONTRACTOR SHALL INSTALL AND COMPLETELY WIRE ALL ASSOCIATED EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WIRE DIAGRAMS AND AS REQUIRED FOR A COMPLETE OPERATING INSTALLATION. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF (FBO) EQUIPMENT PRIOR TO ROUGH-IN OF CONDUIT AND WIRING TO AVOID CONFLICTS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE COMPLETE ELECTRICAL SERVICE WITH LOCAL UTILITY COMPANY FOR A COMPLETE OPERATIONS SYSTEM, INCLUDING TRANSFORMER CONNECTIONS, CONCRETE TRANSFORMER PADS, IF REQUIRED, METER SOCKETS, PRIMARY CABLE RACEWAY REQUIREMENTS, SECONDARY SERVICE, ETC. PRIOR TO SUBMITTING BID TO INCLUDE ALL LABOR AND MATERIALS. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN THE BID ANY OPTIONAL OR EXCESS FACILITY CHARGES ASSOCIATED WITH PROVIDING ELECTRICAL SERVICE FROM LOCAL UTILITY COMPANY. VERIFY BEFORE BIDDING TO INCLUDE ALL COSTS. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE FAULT CURRENT WITH THE LOCAL UTILITY COMPANY PRIOR TO SUBMITTING BID. ADJUST A.I.C. RATINGS OF ALL OVER CURRENT PROTECTION DEVICES IN DISTRIBUTION EQUIPMENT AS REQUIRED TO COORDINATE WITH AVAILABLE FAULT CURRENT FROM LOCAL UTILITY COMPANY. ALL GROUNDING RODS PROVIDED BY THE POWER OR TELEPHONE UTILITY COMPANIES MUST BE TIED INTO THE MAIN EXTERNAL GROUND RING. COORDINATION WITH UTILITY COMPANY: 3. ALL EXPOSED WIRING TO THE LOAD CENTER AND/OR DISCONNECT BOX TO BE PROTECTED BY BLACK LIQUID TIGHT COUNDUIT 3 SCALE: N.T.S. QUAZITE PULL BOX DETAIL18"NOTE: ALL STUB-UP CONDUITS INSIDE PULL BOXES WILL BE 6" FROM TOP OF BOX AND HAVE PULL STRINGS AND CAPS QUAZITE LOGO SKID RESISTANT SURFACE MS-86 Ø 3/8 [10] S.S. FLAT WASHER 2 PLACES 3/8 - 7 X 3 1/2 [89] S.S. HEX HEAD AUGER BOLT 2 PLACES 2X Ø 5/8 [16] THRU W/ Ø1 1/4 [32] X 1/2 [13] DEEP C'BORE PG1324HH00FA4 PG1324PW501 (OPTIONAL)25"15- 1 / 2 " PG1324B623 1/2 [13] X 4 [102] PULL SLOT W/ Ø 3/16 [5] CENTER PIN 2 PLACES Q08-16L100RB LOAD CENTER SPECS N.T.S. FRONT VIEW SIDE VIEW TOP VIEW 8.88"12.65"BREAKER DIAGRAM 4.27"12.65"8.88"4.27"SEE BREAKER DIAGRAM 2.50" Ø MAX.0.28" Ø (3 HOLES) KNOCKOUTS SYMBOL IN MM 0.50 13.0 A 0.75 19.0 B 1.00 25.0 C 1.25 32.0 D A, B, C, D (BOTH SIDES) A, B, C, D A, B, C, D (REAR) A, B, C, D A, BA A, BA WEIGHT = 9.73 POUNDS 100 AMP - 8/16 MAIN LUG. LOAD CENTER LOAD NEUTRAL(S)SERVICE BOND #2 TO NEUTRAL BUSS BOND SCREW LOAD GROUNDS MAIN LUGS NOT USED (A & B) NEUTRAL 00 N 0 B G LINE 1 LINE 2 0 A PK2MB 0 0 0 0 A B A B A B 0 0 0 A B SPARE RETAINING CLIP PER NEC C-BAND ANTENNAS 1 & 2 1P TANDEM 15A QOT1515 C-BAND ANTENNAS 3 & SPARE 1P TANDEM 15A QOT1515 LOAD 7 LOAD 800 QOT1515 0LOAD 5 LOAD 6LOAD 1 LOAD 2 SPARESERVICE MAIN DISCONNECT DUAL POLE 60AMP QO260 LOAD 3 LOAD 4 SPARE SPARE 2 4 1 CONDUIT ROUTING DIAGRAM SCALE: N.T.S. GRADE CONTRACTOR SHALL BUILD INTO THE PRICE OF THE BID THE COST OF TWO (2) MOBILIZATIONS: 1) POWER/FIBER PERMIT PULLED PRIOR TO BUILDING PERMIT AND PRELIMINARY WORK (SMART JACK ON A STICK, ETC) COMPLETED PRIOR TO GENERAL CONSTRUCTION 2) RETURN TO COMPLETE GENERAL ELECTRICAL CONSTRUCTIONUGPUGP UGPUGPUGPGRADE PROPOSED LOAD CENTER W/ DISCONNECT. 8 POSITION BREAKER DROP CABLES ROUTED UP INTERIOR OF POLE TO FIBER BOX (BY VERIZON WIRELESS G.C.) LESSEE LIGHT POLE UGFUGFUGFPROPOSED FIBER BOX SECONDARY CONDUCTORS ROUTED UP INTERIOR OF POLE TO DISCONNECT (BY VERIZON WIRELESS G.C.) NOTE: 1. FIBER TO BE CLEAN AND TESTED PRIOR TO CONNECTING TO RRUS. 2. FIBER STRANDS TO BE FED THROUGH CONDUIT BY VERIZON WIRELESS G.C. EXISTING POWER SOURCE (BY OTHERS) PROPOSED FOUNDATION PROPOSED LESSEE GROUND ROD "E" F A C D FIBER DEMARC (DESIGN AND PERMITTING BY OTHERS) LEGEND (1) NEW 2" SDR 11 HDPE UNDERGROUND CONDUIT FOR POWER FROM NEW LESSEE METER TO NEW LESSEE HANDHOLE NEAR SUBJECT POLE BASE (1) 2" SCH. 40 PVC CONDUIT FOR POWER FROM QUAZITE HANDHOLE TO LOAD CENTER GC TO RE-ROUTE UNDERGROUND CONDUIT FOR STREET LIGHTING THROUGH NEW CONCRETE FOUNDATION "F""A""B" POWER CONDUIT FROM POWER SOURCE TO METER PEDESTAL B "C" "D" E (1) 2" SCH. 40 PVC CONDUIT FOR FIBER FROM QUAZITE HANDHOLE TO FIBER BOX FIBER QUAZITE BOX POWER QUAZITE BOX WITH REDUCER SPLICE (WHEN APPLICABLE) (BY VERIZON WIRLESS G.C.) 30" MIN.PROPOSED METER NOTE: REDUCER SPLICE SPEC: CONDUCTOR: #12-350 PORTS: 2, IN-LINE LISTING: UL 486D,SUBMERSIBLE BASIS: BURNDY UGS350ULDB FUSEHOLDER SPEC: CONDUCTOR: #4 LINE, #4 LOAD QTY. COND. PER TERM. : 1 TYPE: BREAKAWAY BASIS: BUSSMANN HEB/ HET SERIES PHASE: HEB-JW-RLC-J NEUT: HET-JW-RLC-J SUBMERSIBLE BOOT: Y NOTE: COORDINATE SPEC WITH CONDUCTOR SIZES BURIED QUAZITE HANDHOLE FOR POWER CONNECTIONS 3/4" Ø 8'-0" COPPER CLAD GROUND ROD LOAD CENTER (SQUARE D MODEL #:QO816L100RB), W/60A MAIN BREAKER W/RETAINER CLIP (SQUARE D MODEL #: PK2MB) (3) #4 AWG AND (1) #8 AWG GRND CU XHHW-2 WIRES FROM QUAZITE HANDHOLE TO LOAD CENTER N.T.S. SINGLE LINE DIAGRAM 60A 2P 7 3 & 4 8 15A (TANDEM) 15A (TANDEM) 15A (TANDEM) 15A (TANDEM) (SPARE) G N BREAKER CONFIGURATION PER RFDS EQUIPMENT C-BAND #1 C-BAND #2 C-BAND #3BREAKER POSITIONSPOWER SERVICE (BY UTILITY PROVIDER) REMOVE BONDING SCREW "L" LENGTH OF POWER ROUTE FROM POWER SOURCE TO PEDESTAL L = 300' #1 AWG. CU XHHW-2, (1) #6 AWG CU GND IN 2" Ø HDPE 300 < L ≤ 600 L.F.(3) 3/0 XHHW, IN 4" Ø HDPE 600 < L ≤ 900 L.F.(3) #250KCMIL XHHW, IN 4" Ø HDPE NOTE: SERVICE FEEDER BASIS OF DESIGN: SERVICE ENTRANCE CONDUCTORS ARE BASED ON DESIGN LOAD OF 60A AND ARE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3%. CONTRACTOR SHALL VERIFY ALL LUG SIZES AND COORDINATE REQUIREMENTS WITH UTILITY PROVIDER. 100A 2P G N APPROVED METER MAIN, 4 TERMINAL/ RINGLESS, 2 POSITIONS, 120/240V, 1Ø. MILBANK #U5972-XT-LIS-BLG LEGEND GROUNDING WIRE AC POWER CONDUCTORS NEUTRAL CONDUCTOR GRNBLKREDWHTWHT BLK RED GRN 3"Ø CONDUIT BY VERIZON WIRELESS G.C., CONDUCTORS BY UTILITY PROVIDER SEE TABLE FOR CORRECT CONDUCTOR SIZE NEW IN-LINE FUSE (TYP. PER CONDUCTOR) NOTES: 1.C-BAND ANTENNA WIRE SIZE: (2) #12, (1) #12G IN 3/4" C (TYP. OF 3). 6 SPARE5 SPARE 2 SPARE1 SPARE DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415E-2A DESIGN DETAILS UTILITY 1 SCALE: N.T.S. DISCONNECT PEDESTAL (MEANS OF FIRST MAIN DISCONNECT) GROUND WIRE CONNECTED TO NEUTRAL BUSBAR NEUTRAL BONDING JUMPER INSTALLED TO BOND NEUTRAL TO GROUND 2 SCALE: N.T.S. QUAZITE HANDHOLE IN-LINE FUSES INTALLED ON CONDUCTORS COMING FROM POWER SOURCEGROUND WIRE TO DISCONNECT PEDESTAL TO GROUND ROD GROUND WIRE TO LOAD CENTER CONNECTED TO GROUND ROD CONDUITS ARE TERMINATED ADEQUATELY BELOW TOP OF BOX, ALLOWING CABLES TO BEND FREELY WITHOUT KINKS OR DAMAGE BOTTOM OF QUAZITE BOX SHOULD BE FILLED WITH CRUSHED GRAVEL NOT DIRT VERIZON'S WILLIAM FRICK LABEL INSTALLED 3 SCALE: N.T.S. LOAD CENTER (VERIZON DISCONNECT) BONDING SCREW REMOVED PHASE TAPING-NEUTRAL DO NOT USE MAIN LUG EARTH GROUND CONDUCTOR TO GROUND BUS PHASE TAPING-GROUND CONNECT ALL EQUIPMENT GROUNDS TO GROUND BUS - VERIZON REQUIRED G.C. TO F&I HUBBEL LIQUID-TIGHT CONDUIT FITTING (OR APPROVED EQUIVALENT); MATCH SIZE AND COLOR OF THE CONDUIT LIQUID-TIGHT CONDUIT MATCHING POLE COLOR INSTALLED WHEN ROUTING CONDUCTORS FROM BOTTOM OF LOAD CENTER GREEN PHASE TAPE NEEDS TO BE INSTALLED ON GROUND WIRE BELOW LOAD CENTER STRAIN RELIEF CABLE GRAB CONNECTOR PREFERED BY VERIZON PLASTIC INSULATED BUSHING MAIN BREAKER RETAINING BLOCK INSTALLED - VERIZON REQUIRED MAIN DISCONNECT BREAKER LABELED AS "MAIN" DO NOT USE MAIN LUG IMPORTANT NOTES: · WHEN ROUTING POWER AND NEUTRAL THROUGH A DISCONNECT PEDESTAL OR A METERED DISCONNECT, THAT DISCONNECT PEDESTAL OR METERED DISCONNECT WILL BE THE MEANS OF FIRST MAIN DISCONNECT. A NEUTRAL BONDING JUMPER NEEDS TO BE INSTALLED TO BOND NEUTRAL TO GROUND INSIDE THE DISCONNECT PEDESTAL OR METERED DISCONNECT. **INSIDE THE LOAD CENTER ON THE POLE, THE GREEN BONDING SCREW HAS TO BE REMOVED AND THE NEUTRALS AND GROUNDS SEPARATED. · VERIZON REQUIRES THAT ALL EQUIPMENT GROUNDS BE TERMINATED AT GROUND BUSBAR · IF ROUTING CONDUCTORS FROM POLE HANDHOLE TO BOTTOM OF LOAD CENTER, NON-METALLIC LIQUID TIGHT FLEXIBLE CONDUIT MATCHING POLE COLOR SHALL BE USED, OTHERWISE, ROUTE CONDUCTORS FROM BACK OF LOAD CENTER · ANY CONDUCTOR USED AS NEUTRAL MUST HAVE A WHITE INSULATION OR HAVE A WHITE BAND WRAPPED AROUND CONDUCTOR (PHASE TAPING) - NEC REQUIRED · ANY CONDUCTOR USED AS GROUND MUST HAVE A GREEN INSULATION OR HAVE A GREEN BAND WRAPPED AROUND CONDUCTOR (PHASE TAPING) - NEC REQUIRED · WILLIAM FRICK LABELS TO TAG ALL POWER CABLES SHALL BE INSTALLED IN THE FOLLOWING PLACES: **AT SERVICE CONNECTION POINT AT POWER SOURCE (RISER POLE, GROUND TRANSFORMER, POWER PEDESTAL, MANHOLE) **INSIDE QUAZITE HANDHOLE **IN HANDHOLE ON POLE · THE FOLLOWING INFORMATION TO BE PLACED ON THE WILLIAM FRICK TAG: **UTILITY NAME: "VERIZON" **SERVICE TYPE: "POWER" **VZW SITE ID **UTILITY COMPANY NB ACCT # **24/7 EMERGENCY NUMBER: 1-800-264-6620 · QUAZITE HANDHOLE SHALL BE INSTALLED ON 4"-6" MINIMUM OF 3/4" CRUSHED GRAVEL · LABEL TO IDENTIFY MAIN BREAKER TO BE INSTALLED ON MAIN BREAKER OR AT MINIMUM BE IDENTIFIED IN THE LEGEND DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415E-3 AND DETAILS GROUNDING PLAN 2 Type VN Type VS Type GT Type TA Type HS Type GY Type GR Type NC Type VV Type XB EXOTHERMIC AND HARGER ULTRAWELD OR APPROVED EQUAL EXOTHERMIC WELD DETAILS HORIZONTAL CABLE TAP TO VERTICAL STEEL SURFACE OR THE SIDE OF HORIZONTAL PIPE THROUGH CABLE TO TOP OF GROUND ROD. TEE OF HORIZONTAL RUN AND TAP CABLES. HORIZONTAL CABLE TAP TO HORIZONTAL STEEL SURFACE OR PIPE. CABLE OFF SURFACE. CABLE TAP DOWN AT 45° TO VERTICAL STEEL SURFACE OR SIDE OF HORIZONTAL OR VERTICAL PIPE. THROUGH CABLE TO SIDE OF GROUND ROD THROUGH VERTICAL CABLE TO VERTICAL STEEL SURFACE OR TO THE SIDE OF EITHER HORIZONTAL OR VERTICAL PIPE CABLE TAP TO TOP OF GROUND ROD THROUGH AND TAP CABLES TO GROUND ROD CROSS OF HORIZONTAL CABLES. LAPPED AND NOT CUT 1. ALL GROUNDING CONNECTIONS SHALL BE MADE BY THE EXOTHERMIC PROCESS CONNECTIONS SHALL INCLUDE ALL CABLE TO CABLE, SPLICES, ETC. ALL CABLE TO GROUND RODS, GROUND RODS SPLICES AND LIGHTNING PROTECTION SYSTEM AS INDICATED. GROUND FOUNDATION ONLY AS INDICATED BY PM. ALL MATERIALS USED (MOLDS, WELDING, METAL, TOOLS, ETC.) SHALL BE BY EXOTHERMIC PROCESS AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND PROCEDURES. GROUND CONDUCTOR SHALL HAVE A MINIMUM 24" BENDING RADIUS. 2. ALL EXOTHERMIC CONNECTIONS ON GALVANIZED SURFACES SHALL BE CLEANED THOROUGHLY AND COLORED TO MATCH SURFACE WITH (2) TWO COATS OF SHERWIN-WILLIAMS GALVITE (WHITE) PAINT B50W3 (OR EQUAL) OR SHERWIN- WILLIAMS SILVERBRITE (ALUMINUM) B59S11 (OR EQUAL). 3. ALL ELECTRICAL & MECHANICAL GROUND CONNECTIONS SHALL HAVE ANTI-OXIDANT COMPOUND APPLIED TO CONNECTION GROUNDING ELECTRODE SYSTEM NOTES: 6. UTILITY COMPANY COORDINATION: ELECTRICAL CONTRACTOR SHALL CONFIRM THAT ALL WORK IS IN ACCORDANCE WITH THE RULES OF THE LOCAL UTILITY COMPANY BEFORE SUBMITTING THE BID, THE CONTRACTOR SHALL CHECK WITH THE UTILITY COMPANIES SUPPLYING SERVICE TO THIS PROJECT AND SHALL DETERMINE FROM THEM ALL EQUIPMENT AND CHARGES WHICH THEY WILL REQUIRE AND SHALL INCLUDE THE COST IN THE BID. 7. GROUND TEST: GROUND TESTS SHALL BE PERFORMED AS REQUIRED BY LESSEE STANDARD PROCEDURES. GROUND GRID RESISTANCE SHALL NOT EXCEED 5 OHMS. 8. CONTRACTOR SHALL SUBMIT THE GROUND RESISTANCE TEST REPORT AS FOLLOWS: 5/8" DIAMETER x 8'-0" LONG COPPER CLAD GROUND ROD (HARGER-588) 5/8" DIAMETER X 8'-0" LONG COPPER CLAD GROUND ROD WITH INSPECTION WELL #2 AWG TNND SOLID BARE COPPER WIRE MINIMUM 42" BELOW GRADE (HARGER-L2) EXOTHERMIC WELD 1. ONE (1) COPY TO OWNER REPRESENTATIVE 2. ONE (1) COPY TO ENGINEER 3. ONE (1) COPY TO KEEP INSIDE EQUIPMENT ENCLOSURE LEGEND: UGE UNDERGROUND POWER LINE UGF UNDERGROUND FIBER LINE OHE OVERHEAD POWER LINE GAS GAS LINE OHT OVERHEAD TELCO LINE MECHANICAL CONNECTION 1 KNOW WHAT'S BELOW. CALL BEFORE YOU DIG. Call 811, 1-800-382-5544 CONTACT INDIANA 811 TWO WORKING DAYS BEFORE STARTING PROJECT N.T.S. TYPICAL GROUNDING SCHEMATIC #2 GREEN STRANDED COPPER CONDUCTOR GRADE POLE 100 AMP LOAD CENTER FIBER BOX (2) LESSEE GROUND RODS 6' #2 AWG CU BONDING CONDUCTOR #4 AWG SOLID BARE COPPER CONDUCTOR (TYP. FOR TAIL CONNECTIONS) AIR1672 (TYP.) COMPRESSION CONNECTOR (TYP.) 3 4 1 NOTE: ELECTRICAL CONTRACTOR TO INSTALL GROUND ROD AS BEST FIT. IN SOME INSTANCES, SITE CONDITIONS MAY DICTATE GROUND ROD PLACEMENT. DETAIL IS FOR SCHEMATIC PURPOSES ONLY. SCALE: N.T.S. TYPICAL NODE GROUNDING PLAN HOMERUN GROUND FROM ANTENNA BRACKET 1 2 LIGHT POLE GROUND ROD 6 4 3 5 TYPICAL KEYED GROUNDING NOTES #2 GREEN STRANDED COPPER CONDUCTOR, 42" BELOW GRADE (TYPICAL) MINIMUM 24" BENDING RADIUS 5/8" DIAMETER X 8'-0" LONG COPPER CLAD GROUND ROD (HARGER-588) WITH EXOTHERMIC CONNECTION 1 2 ENCLOSURE GROUND (TYP.) IN 1/2" DIAMETER SCHEDULE 40 PVC CONDUIT 4 ELECTRIC METER AND ELECTRIC SERVICE GROUNDING, COORDINATE ALTERNATE WITH PM5 3 #2 AWG TNND SOLID COPPER CONDUCTOR 42" BELOW GRADE GROUND H-FRAME POST TO GROUND LEAD WITH #2 AWG SOLID BARE TINNED COPPER GROUND WIRE ENCASED IN 3/4" SEALTITE LFNC-B, EXTEND SEALTITE 18" BELOW GRADE (TYP. OF 2) 6 METER GROUND ROD DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415STRUCTURAL DETAILS S-1SCALE: N.T.S LGX PANEL LOAD CENTER SCHEMATIC RADIO & EQUIPMENT MOUNT POLE STAINLESS STEEL CLAMP (TYP.) SCHEMATIC C-BAND ANTENNA MOUNT SCALE: N.T.S. POLE/PIPE PROPOSED 3/4" HEAVY DUTY STAINLESS STEEL BANDING, COMMSCOPE OR APPROVED EQUAL PROPOSED POLE MOUNTING KIT 1 2 DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415STRUCTURAL DETAILS S-21SCALE: N.T.S CITY OF SOUTH BEND BRICK PAVER REPLACEMENT DETAIL CITY OF SOUTH BEND COMMERCIAL SIDEWALK DETAIL SCALE: N.T.S2 NOTES: BRICK PAVER PREPARATION 1.REMOVE ORGANIC, UNSTABLE OR UNCONSOLIDATED MATERIAL FROM SITE, VERIFY CONFORMANCE OF SUBGRADE PREPARATION, COMPACTED DENSITY AND ELEVATIONS TO SPECIFIED REQUIREMENTS. 2.CLEAN AND RE-USE EXISTING STREET BRICK PAVERS REMOVED DURING SITE DEMOLITION. REMAINING PAVERS NOT USED WILL BE RETURNED TO THE CITY. 3.PLACE COMPACTED AGGREGATE NO. 53 TO LINES AND GRADE. 4.SPREAD #12 LIMESTONE CHIPS EVENLY OVER CRUSHED STONE BASE COURSE AND SCREED RAILS. (SCREED TO 1 INCH MINIMUM THICKNESS: a) DO NOT SPREAD #12 LIMESTONE CHIPS BEYOND AREA TO BE COVERED BY PAVERS THE SAME DAY. PRIOR TO RECOMMENCEMENT OF WORK, REMOVE, REPLACE AND RE-SCREED #12 LIMESTONE CHIPS NOT COVERED WITH PAVERS THE PREVIOUS WORK DAY. b) DO NOT DISTURB SCREEDED SETTING BED. RE-SCREED DISTURBED SETTING BED. 5.LAY PAVERS BY HAND IN PATTERN(S) MATCHING EXISTING LAYOUT. a) LAY FULL PAVERS FIRST. b) MIX PAVERS FROM AT LEAST TWO PALLETS TO PRODUCE UNIFORM COLOR BLENDS. 6.PROVIDE 1/16 INCH TO 3/16 INCH WIDE JOINTS BETWEEN PAVERS. ADJUST PAVERS TO FORM STRAIGHT BOND LINES AND APPROPRIATE JOINT WIDTHS. MAXIMUM BOND LINE VARIATION SHALL BE +-_INCH OVER A 50 FOOT STRING LINE. 7.FILL GAPS AT PAVED AREA EDGES WITH CUT PAVERS. a) CUT PAVERS SHALL NOT BE SMALLER THAN 1/3 (ONE-THIRD) OF A WHOLE PAVER EXCEPT WHERE PATTERN IS TO BE MAINTAINED AND A SMALLER PIECE IS SURROUNDED BY A FULL PAVER AND CONCRETE BANDING. 8.DO NOT PERMIT TRAFFIC, INCLUDING CONSTRUCTION EQUIPMENT, ON PAVERS BEFORE INITIAL COMPACTION AND JOINT FILLING. DISTURBED AREAS OF PAVERS SHALL BE TAKEN UP, THE SETTING BED RE-SCREEDED AND PAVERS RE-LAID. 9.VIBRATE PAVERS INTO SETTING BED USING A HIGH FREQUENCY/LOW-AMPLITUDE PLATE COMPACTOR CAPABLE OF 3,000 LBF TO 5,000 LBF AT A 75 TO 100 HZ FREQUENCY. PROTECT PAVERS FROM CHIPPING DURING COMPACTION BY USING A RUBBER MATT, RUBBER ROLLERS OR OTHER APPROVED MATERIALS PLACED OVER PAVERS. DO NOT COMPACT WITHIN 6 FEET OF UNRESTRAINED EDGES. REMOVE CRACKED OR DAMAGED PAVERS AND REPLACE WITH NEW UNITS. 10.AFTER PAVERS ARE FULLY SETTLED AND FREE FROM MOVEMENT, SIMULTANEOUSLY SPREAD, SWEEP AND COMPACT DRY #12 LIMESTONE CHIPS INTO JOINTS UNTIL THEY ARE COMPLETELY FILLED AND CHIPS NO LONGER FALLS INTO JOINTS. 11.PROTECT AREAS NOT COVERED WITH CUT AND COMPACTED PAVERS WITH WATERPROOF COVERING OVERNIGHT. NOTES: BRICK PAVER PREPARATION 1.CLASS "A" CONCRETE TO BE USED IN ALL WALKS AND APPROACHES. 2.UTILITY POLES, HYDRANTS, ETC. MUST BE WRAPPED WITH 1/2" EXPANSION MATERIAL PRIOR TO CONCRETE POUR. 3."CURING CONCRETE"- AS PER INDOT STANDARD SPECIFICATIONS SECTION 501 (PARAGRAPH 501.20). USE A CURING COMPOUND IMMEDIATELY (WHITE MEMBRANE ONLY ACCEPTED CURE). 4.CONCRETE FORMS SHALL BE AT LEAST AS HIGH AS THE THICKNESS OF THE ITEM SHOWN. LUMBER OF NOMINAL DIMENSION SHALL NOT BE USED IF LESS THAN THE DESIGN THICKNESS. 5.PROPER COMPACTION PER INDOT STANDARD SPECIFICATION SECTION 604 (PARAGRAPH 604.03(B)) IS REQUIRED FOR ALL WALKS AND APPROACHES. 6.BLANKETS SHALL BE UTILIZED ON CONCRETE WHEN TEMPERATURE IS EXPECTED TO FALL BELOW 50°F. 7.A PEDESTRIAN ACCESS ROUTE (4'-0" MIN. WIDTH, 1.5% MAX. CROSS SLOPE) SHALL BE PROVIDED WITHIN ALL COMMERCIAL SIDEWALKS. DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415SP-1 SPECIFICATIONS DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415TC-1 CONTROL PLAN TRAFFIC NOTES: 1.DETAIL PROVIDED IS FOR REFERENCE ONLY. REFER TO THE CURRENT VERSION OF WORK ZONE TRAFFIC CONTROL GUIDELINES BY INDIANA DEPARTMENT OF TRANSPORTATION TRAFFIC CONTROL FOR MORE INFORMATION. 2.VERIZON WIRELESS G.C. TO BE FAMILIAR WITH THE CURRENT VERSION OF INDIANA DEPARTMENT OF TRANSPORTATION STANDARDS FOR TRAFFIC CONTROL. 3.VERIZON WIRELESS G.C. TO PROVIDE OTHER METHODS OF TRAFFIC CONTROL DEEMED APPLICABLE PER JOB LOCATION AND CONDITIONS. DESCRIPTIONREVISIONSSHEET NUMBER SHEET TITLE DATE: PROJECT #: CHECKED BY: DRAWN BY:NO.BYDATEABCISSUED FOR REVIEWADD RFDS& UTIL. COOR; ISSUED FOR PERMITTINGUPDATED PER LATEST RFDS TO C-BAND ONLY02/19/2609/08/2610/06/26RC/DKMM/DKDKMDG# 5000971310 W ANGELA 1044 E ANGELA BLVD SOUTH BEND, IN 46617 AC TAZ 08/22/25 265-0841701 GOLF ROAD,TOWER 2, SUITE 400ROLLING MEADOWS, IL 60008PHONE: (847) 619-5397FAX: (847) 706-7415TC-2 CONTROL PLAN TRAFFIC NOTES: 1.DETAIL PROVIDED IS FOR REFERENCE ONLY. REFER TO THE CURRENT VERSION OF WORK ZONE TRAFFIC CONTROL GUIDELINES BY INDIANA DEPARTMENT OF TRANSPORTATION TRAFFIC CONTROL FOR MORE INFORMATION. 2.VERIZON WIRELESS G.C. TO BE FAMILIAR WITH THE CURRENT VERSION OF INDIANA DEPARTMENT OF TRANSPORTATION STANDARDS FOR TRAFFIC CONTROL. 3.VERIZON WIRELESS G.C. TO PROVIDE OTHER METHODS OF TRAFFIC CONTROL DEEMED APPLICABLE PER JOB LOCATION AND CONDITIONS. 2" DIA. ALUMINUM COUPLING LOCATED54" UP FROM BUTT OF POLE &ORIENTATED 270° RIGHT OF HANDHOLE"E" OVERALL POLE HEIGHTPOLE SHAFT FABRICATED FROM6063-T4 ALUMINUM TUBE (POLEASSEMBLY IS HEAT TREATED TOT6 CONDITION AFTER WELDING)6.22" O.D. @ POLE TOPFACTORY INSTALLED VIBRATIONDAMPENER LOCATED "I" FROMBUTT OF POLE"2ND HH""3RD HH""4TH HH""5TH HH"(3) 2 3/8" x 4" EXTERNALLY REINFORCEDALUMINUM HANDHOLE OPENING &ALUMINUM DOOR, WITH A GASKET(1) 2 3/8" x 4" EXTERNALLY REINFORCEDALUMINUM HANDHOLE OPENING &ALUMINUM DOOR, WITH A GASKET(1) 2 3/8" x 4" EXTERNALLY REINFORCEDALUMINUM HANDHOLE OPENING &ALUMINUM DOOR, WITH A GASKET"1ST HH"OPEN POLE TOP"6TH HH"EXTERNAL FESTOON CASTING,GFCI RECEPTACLE, & COVER(SEE "DIMENSION TABLE")"ARM" NOMINAL MOUNTING HEIGHT"H" NOMINAL MOUNTING HEIGHT4'-9" SMOOTH(4) NON-BREAKAWAY BANNERARMS FOR (2) 24" WIDE BANNERSLOCATED 90° & 270° RIGHT OFHANDHOLE (SEE "PAGE 2")"BAN. ARMS"4'-0""FESTOON" NOMINAL MOUNTING HEIGHTSINGLE BISHOPS CROOK ARM W/(4) 1/2"-13 x 2" LG. SS BOLTS,(4) 1/2" SS SPLIT-LOCK WASHERS, &(4) 1 1/4" O.D. SS FLAT WASHERS(SEE "ARM DETAIL", "DIMENSION TABLE"; &SEE "POLE MOUNTING PLATE DETAIL" ON "PAGE 2")FOOTING, REINFORCINGROD, AND PVC CONDUIT(BY OTHERS)CAST ALUMINUM ANCHOR BASE BENEATHTWO-PIECE AVALON ALUMINUM CLAMSHELL(SEE "DETAIL A" & "DETAIL B")90°180°270°BISHOPS CROOK ARM,BANNER ARMS0°1ST HANDHOLE,6TH HANDHOLE,EXTERNAL FESTOONORIENTATION DETAIL12 FLAT FLUTE2ND HANDHOLE,3RD HANDHOLE,4TH HANDHOLE,5TH HANDHOLE,2" COUPLING,BANNER ARMSBUTT OF POLETO BOTTOM OFANCHOR BASE(4) 1"-8 x 36" LG. PARTIALLYGALVANIZED ANCHOR BOLTS(MIN. YIELD STRENGTH 55 KSI)13 1/2" DIA. MIN.BOLT CIRCLE15" DIA. MAX.BOLT CIRCLE(4) BOLT SLOTSDETAIL BDETAIL A5" BASEHEIGHT12 15/16"7/32"3/8"10" O.D. x "WALL"@ BUTT OF POLE"1ST HH"4" x 6" REINFORCED ALUMINUMHANDHOLE OPENING WITH5/16"-18 HOLE FOR A GROUNDCONNECTOR AND FLUSHFITTING ALUMINUM DOOR,WITH A GASKETALUMINUMPOLE SHAFT51"NOTE: CLAMSHELLNOT SHOWN9 5/8" I.D.TWO-PIECE AVALONALUMINUM CLAMSHELL(ONE HALF SHOWN)26 1/4" O.D.ARM DETAILR15"9 1/2"40 1/16"8 1/2"1 1/2" SCH. 80(1.900" x .200" WALL)ALUMINUM PIPE ARM(6061-T6 ALLOY)24 7/16"56"2 1/2"TYP.(2) 1 1/2" SCH. 80(1.900" x .200" WALL)ALUMINUM PIPE SUPPORTS(6061-T6 ALLOY)4"4" W. x 1/2" THK.RECTANGULAR ALUMINUM(6061-T6 ALLOY)3/4" I.D. RUBBER GROMMET1 1/2" ZINC BUTT CAP3/16"CHG'D CLAM & FLUTE, MV'D COUPLING04-23-261PTPSCAST ANCHOR BASE FLUTED POLE1ALUMINUM ALLOYPOWDER PAINT - BLACK DBLVERIZON - TERRA CONSULTING - W ANGELATHE WILL GROUPPTP02-02-26A5994412DIMENSION TABLEEHIWALL1ST HH2ND HH3RD HH4TH HH5TH HH6TH HHFESTOONARMBAN. ARMS27'-0"17'-10"16'-0".219"1'-6"LOC.@ 0°14'-6"LOC.@ 270°17'-0"LOC.@ 270°19'-9'LOC.@ 270°23'-3"LOC.@ 270°26'-0"LOC.@ 0°12'-1"LOC. @ 0°15'-5"LOC.@ 90°9'-1"LOC. @90° & 270°Valmont Industries, Inc. Structures Division20805 Eaton Ave Farmington, Minnesota 55024-7932Phone: (651) 463-8990 (800) 899-7577Fax: (651) 463-3349**CONFIDENTIAL**The information contained in this drawing is privileged and confidential,and may be protected from disclosure. Please be aware that any use ordissemination of this drawing may be subject to legal restriction or sanction.TITLE:MODEL NO.:MATERIAL:FINISH:PROJECT:SOLD TO:SHIP TO:P.O. NO:REP:REVDATEREVISION DESCRIPTIONBY/PAGE:DWG NO:DATE:APPR BY:CHK'D BY:DWN BY:QTY:POLE RATING (PER AASHTO 2013):3-SEC GUST WIND SPEED: 90 MPH MAXEXISTING FIXTURE: 1.79 SQ. FT. MAX. AND 32 LBS MAX.ANTENNA & MOUNT @ 29'-6" A.G.L.: 3.57 SQ. FT. AND 64 LBS(3) 5G RADIOS @ 25'-4" A.G.L.: 4.2 SQ. FT. AND 80 LBS TOTAL4G EQUIPMENT @ 22'-0" A.G.L.: 8 SQ. FT. AND 199 LBSLOAD CENTER @ 19'-0" A.G.L.: 0.94 SQ. FT. AND 10 LBSLGX PANEL @ 16'-0" A.G.L.: 1 SQ. FT. AND 20 LBSSPEAKER @ 14.5FT A.G.L.: 1 SQ. FT. AND 10 LBSMETER SOCKET @ 5.5 FT A.G.L.: 1 SQ. FT. AND 10 LBSTWIN 48IN x 24IN NON BKWY BANNERS WITHLOWER ARMS @ 9.75FT A.G.L.25 LBS OF CABLE (AXIALLY LOADED)1111 (2) 2 1/4" DIA. DISKS1/8"(2) 1 1/4" SCH. 80(1.660" O.D. x .191" WALL)ALUMINUM PIPE ARMS(6061-T6 ALLOY)AAALUMINUM SHAFT1 1/2"2 1/2"25"(2) 1/4"-20 x 2 1/2" LG. SS HEX BOLTS(2) 1/4"-20 SS NYLON-INSERTHEX LOCKNUTS(4) 1/4" I.D. x 5/8" O.D. SS WASHERSSECTION A-A(2) 2" O.D. x .250" WALL x 2 1/2" LG.ALUMINUM TUBE COUPLINGS(BORED TO 1.695" I.D.)(6063-T6 ALLOY)TYP.TYP.3/8"BANNER ARM DETAIL3/4"2 1/2"2"4"12"2 1/2"3/4"Ø1" WIRE ACCESS HOLE(EDGES DEBURRED)DRILL & TAP(4) 1/2"-13 HOLES THRUPLATE & POLE WALL7/16"7/8"3/16"3/16"TOP VIEWTYP.(2) Ø3/8" ALUMINUMRODS FOR WELDING(6061-T6 ALLOY)POLE MOUNTING PLATE DETAIL(LESS POLE SHAFT)6" ALUMINUM SHAFT MOUNTINGEXTRUSION (6061-T6 ALLOY)CHG'D MOUNTING04-23-261PTPSDETAILSALUMINUM ALLOYPOWDER PAINT - BLACK DBLVERIZON - TERRA CONSULTING - W ANGELATHE WILL GROUPPTP02-02-26A5994422Valmont Industries, Inc. Structures Division20805 Eaton Ave Farmington, Minnesota 55024-7932Phone: (651) 463-8990 (800) 899-7577Fax: (651) 463-3349**CONFIDENTIAL**The information contained in this drawing is privileged and confidential,and may be protected from disclosure. Please be aware that any use ordissemination of this drawing may be subject to legal restriction or sanction.TITLE:MODEL NO.:MATERIAL:FINISH:PROJECT:SOLD TO:SHIP TO:P.O. NO:REP:REVDATEREVISION DESCRIPTIONBY/PAGE:DWG NO:DATE:APPR BY:CHK'D BY:DWN BY:QTY:1 SHEET NUMBER:W ANGELA 27' ALUMINUM POLE SOUTH BEND, IN TCG PROJECT # 265-084 S-1 ELEVATION VIEW8'-2"2'-6" DIA. A C B GRADE FOUNDATION NOTES: 1.TOWER AND FOUNDATION DESIGN HAS BEEN COMPLETED IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING CODE AND THE TIA-222-H STANDARD. 2.CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4,000 PSI, IN ACCORDANCE WITH ACI 318-11. 3.REBAR TO CONFORM TO ASTM A615 GRADE 60. 4.ALL REBAR TO HAVE A MINIMUM OF 3” CONCRETE COVER. 5.ALL EXPOSED CONCRETE CORNERS TO BE CHAMFERED 3/4”. 6.THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING FACTORED LOADS: MOMENT = 25 K-FT AXIAL = 1 K SHEAR = 2 K 7.TOTAL CONCRETE VOLUME: 2 CUBIC YARDS 8.FOUNDATION HAS BEEN DESIGNED USING THE USING THE FOLLOWING PRESUMPTIVE SOIL PROPERTIES PROVIDED IN ANNEX F OF TIA-222 H STANDARD: UNIT SOIL WEIGHT: 110 PCF COHESION: 500 PSF ULTIMATE BEARING CAPACITY: 3000 PSF ANCHOR RODS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS (1) 2" Ø CONDUIT SLEEVE FOR POWER & (1) 2" Ø CONDUIT SLEEVE FOR FIBER (2 TOTAL) REINFORCING BAR SCHEDULE ITEM QUANTITY SIZE SPACING A 9 #6 EQUALLY B 2 #4 (2) BARS WITHIN TOP/BOTTOM 5" C 9 +/-#4 12" O.C.42" MAX.B30" MIN.(2) 1" Ø CONDUIT FOR TOWER GROUND LEADS 7'-6"0'-8"(2) 2" Ø CONDUIT FOR STREET LIGHTING PROPOSED PROJECT POLE: Latitude: N 41° 41' 33.80" Longitude: W086° 14' 09.16" CE E E E E E E E E E E E E E E EGAS GAS GAS GAS GAS GAS GAS GASCCCCCCC C C C C C Brick Paver Border 4 Story Brick Building Bench Electric Outlet Asphalt Pavement (Variable Width, Public Right of Way) ANGELA BOULEVARD Concrete Curb Concrete Curb and Gutter Street Light and Traffic Signal Light with Mast-Arm C C C ES S Concrete Sidewalk Concrete Wall Traffic Signal Box on Pad Overhang 6" 740.61 740.76 740.75 740. 7 8 740.81 740.6 9 740.84 740.65 740.65 740.43 740.42 740.41 740.57 740.37 739.86 739.83 740. 2 7 739.84 740.04 740.18 739.86 739.79 740. 1 1 740.28 740.42 740.45 740.48 740.44 740.43 740.33 740.67 740.3 2 740.23 740.35 739.95 739.91 740.4 4 740.41 740.40 740.43 740.39 740.65 740.67 740.75 740.70 740.76 740.7 9 740.81 740.86 740.65 740.87 740.78 7 4 0 . 7 5 740.78 740.72 740.64 740.64 740.38 740. 3 7 740.08 740.34 739.85 740.00 739.87 739.78 739.68 739.62 739.50 739.96 739.94 739. 9 3 740.06 739.61 740.08 739.55 739.83 740.30 740.47 739.99 740.47 739. 9 4 740.05 740.48 740.89 740.83 740.18Concrete Pavement Landscape Median Brick Paver SITE BENCHMARK: Chiseled Square on Concrete Walk Elevation = 740.41 EDDY STREET COMM O N S M A J O R S U B D I V I S I O N (SECTION ONE) LOT 1 Tax ID: 71-08-01-229- 0 0 3 . 0 0 0 - 0 2 6 Grass South Right of Way Line 20.8'55.7' Concrete Wall North Line of Lot 1 Communication Marked Clear Existing Light Pole Storm Sewer ManholeS Irrigation Control Valve THAT PART OF THE PUBLIC RIGHT OF WAY OF ANGELA BOULEVARD LYING NORTH OF AND ADJACENT TO LOT 1 IN EDDY STREET COMMONS MAJOR SUBDIVISION (SECTION ONE) ACCORDING TO THE PLAT THEREOF RECORDED AUGUST 26, 2008 AS DOCUMENT 0828220, IN THE OFFICE OF THE RECORDER, ST JOSEPH COUNTY, INDIANA. PROJECT NO. CHECKED BY: KWS SITE DESIGNATION INFORMATION: 770687 DRAWN BY: EM NOT TO SCALE PREPARED FOR: SMALL CELL - SITE SURVEY CNVDADE & MA EINYV SU R P IPA N G GPutting the Pieces Together.... Since 1984 JOB No.: 265-084 THERE WAS NO SNOW COVER, BUT PILED PLOWED SNOW UP TO 6" AT THE TIME OF THE FIELD SURVEY. RIGHT OF WAY SHOWN HEREON ARE BASED UPON THE RECORDED SUBDIVISION PLATS UNLESS NOTED OTHERWISE. THE SURVEYOR EXPRESSES NO OPINION AS TO THE ACCURACY OF ANY UNDERGROUND UTILITIES WHEN NOT READILY VISIBLE FROM THE SURFACE. IT IS RECOMMENDED THAT THE APPROPRIATE GOVERNMENTAL AGENCY, MUNICIPALITY AND/OR UTILITY COMPANY BE CONTACTED FOR VERIFICATION. THE TAX ID NUMBER FOR THE PROPERTY LYING SOUTH OF AND ADJACENT TO THE PROJECT POLE IS 71-09-06-101-002.000-026. SEE SHEET 2 OF 2 FOR THE SURVEYOR'S REPORT. A CURRENT TITLE REPORT WAS NOT FURNISHED TO US FOR OUR USE IN PREPARING THIS SURVEY. THEREFORE THERE MAY BE ADDITIONAL EASEMENTS AND/OR SERVITUDES EFFECTING THIS PROPERTY WHICH ARE NOT SHOWN ON THIS SURVEY. SOURCE BENCHMARK: NGS MONUMENT DESIGNATION - F 20 PID - ME0108 STATE / COUNTY - IN / ST JOSEPH USGS QUAD - SOUTH BEND WEST (2019) ELEVATION = 737.37 (NAVD88) BENCHMARK INFO UNDERGROUND UTILITY LOCATE 811 TICKET # 25121804174 ORDERED: 12/18/2025 MARKED BY: 12/23/2025 LEGEND LOCATION MAP SURVEYOR'S CERTIFICATE SURVEY NOTES LEGAL DESCRIPTION STATE OF ILLINOIS SS COUNTY OF KANE I, KEITH W. STODDARD, AN INDIANA REGISTERED LAND SURVEYOR, DO HEREBY CERTIFY THAT THE PLAT SHOWN HEREON, BEING COMPLETED IN THE FIELD ON 12/23/2025 IS A CORRECT REPRESENTATION OF A SURVEY PERFORMED AT AND UNDER MY DIRECTION. THIS SURVEY MEETS THE MINIMUM TECHNICAL STANDARDS FOR A LAND BOUNDARY AND TOPOGRAPHIC SURVEY SET FORTH BY INDIANA STATE LAW. ALL DIMENSIONS ARE IN FEET AND DECIMAL PARTS THEREOF. GIVEN UNDER MY HAND AND SEAL THIS 28TH DAY OF JANUARY, A.D. 2026. L-1SHEET 1 OF 2 PREPARED BY: PHONE: (847) 619-5397 FAX: (847) 706-7415 ROLLING MEADOWS, ILLINOIS 60008 1701 GOLF ROAD, TOWER 2, SUITE 400 O' 10' 20' 40' 11" X 17" PRINT IS THE FULL SCALE FORMAT OF THIS SURVEY. ANY OTHER SIZE IS AT AN ADJUSTED SCALE. SCALE : 1" = 20' 89 MILS 5°1' CENTER OF QUAD MAP DECLINATION AT 0°32' UTM GRID AND 2022 MAGNETIC NORTH 9 MILS MN GN BEARINGS SHOWN HEREON ARE BASED ON INDIANA STATE PLANE, EAST ZONE, NAD83 (2011) BASIS OF BEARING MEAN MAGNETIC DECLINATION OBTAINED FROM U.S.G.S. 7 1/2 MINUTE SERIES MAP SOUTH BEND EAST QUADRANGLE STATE OF INDIANA LATITUDE: N 41° 41' 33.80" LONGITUDE: W086° 14' 09.16" AT CENTER OF PROJECT POLE COMPLIES WITH F.A.A. 1/A ACCURACY REQUIREMENTS REVISION FIELD SURVEY COMPLETED12/23/20251. 01/28/20252.FINAL SURVEY COMPLETED NO.DATE KEITH W. STODDARD INDIANA REGISTERED LAND SURVEYOR NO. 20000004 LICENSE EXPIRES 7/31/2026 OFOE RDLS20000004 N STATE OFK A L ND IR N US D RV AI oN .!!OYE A RANWTIH OS E S . SI T D AD PLW ANGELA 5000971310 1044 E ANGELA BLVD SOUTH BEND, IN 46617 ST JOSEPH COUNTY Underground Communication LineC 740.48 Spot Elevation Communication ManholeC Underground Storm Line E Underground Electric Line ASM Consultants, Inc. Professional Land Surveying and Engineering 16 E Wilson St - Batavia IL 60510 (630) 879-0200 - advanced@advct.com Professional Design Firm #184-006014 expires 4/30/2027 COPYRIGHT 2026, ASM CONSULTANTS, INC. ALL RIGHTS RESERVED.c Depressed Curb Storm Curb Inlet Underground Gas LineGAS Electric ManholeE Communication Handhole Building Asphalt Pavement Concrete Pavement Traffic Signal Light Brick Pavers 6" Deciduous Tree and size in inches SITE 4 Story Brick Building Asphalt Pavement (Variable Width, Public Right of Way) ANGELA BOULEVARD Concrete Curb Concrete Curb and Gutter Concrete Sidewalk EDDY STREET COMMONS MAJOR SUBDIVISION (SECTION ONE) LOT 1 South Right of Way Line (80' Public Right of Way)EDDY STREET Tax ID: 71-08-01-229-003.000-026(Variable Width, Public Right of Way) NAPOLEON BOULEVARDN.02°44'02"W. 512.14'S.78°02'36"E. 47.16'S.89°21'11"E. 130.00'N.88°23'08"E. 24.38'S.00°20'45"E. 504.25'(S.78°02'36"E. 47.16')(S.89°21'11"E. 130.00')(N.88°23'08"E. 24.38')(N.02°44'02"W. 512.14')(S.00°20'45"E. 504.25')(N.88°57'46"W. 179.14') N.88°57'46"W.179.14'West Right of Way LineNorth Line of Lot 1 PROJECT NO. CHECKED BY: KWS SITE DESIGNATION INFORMATION:DRAWN BY: EM NO.DATE REVISION FIELD SURVEY COMPLETED 2. 1. 770687 12/23/2025 01/28/2026 L-2SHEET 2 OF 2 PREPARED BY: PREPARED FOR: SMALL CELL - SITE SURVEYCN VDADE & MA EINYV SUR P IPA N G GPutting the Pieces Together.... Since 1984 0' 40' 80' 160' SCALE : 1" = 80' BEARINGS SHOWN HEREON ARE BASED ON INDIANA STATE PLANE, EAST ZONE, NAD83 (2011) PHONE: (847) 619-5397 FAX: (847) 706-7415 ROLLING MEADOWS, ILLINOIS 60008 1701 GOLF ROAD, TOWER 2, SUITE 400 AS REQUIRED BY TITLE 865, ARTICLE 1, CHAPTER 12, OF THE INDIANA ADMINISTRATION CODE ("RULE 12"), THE FOLLOWING OBSERVATIONS AND OPINIONS ARE SUBMITTED REGARDING THE VARIOUS UNCERTAINTIES IN THE LOCATIONS OF THE LINES AND CORNERS ESTABLISHED IN THIS SURVEY AS A RESULT OF UNCERTAINTIES IN REFERENCE MONUMENTATION; IN RECORD DESCRIPTIONS AND PLATS; IN LINES OF OCCUPATION; AND AS INTRODUCED BY RANDOM ERRORS IN MEASUREMENT ("RELATIVE POSITIONAL ACCURACY"). THERE MAY BE UNWRITTEN RIGHTS ASSOCIATED WITH THESE UNCERTAINTIES. THIS SURVEY IS WITHIN THE ALLOWABLE RELATIVE POSITIONAL ACCURACY FOR MEASUREMENTS CONTROLLING LAND BOUNDARY'S FOR SUBURBAN SURVEYS: 0.13 FOOT (40 MILLIMETERS) PLUS 100 PARTS PER MILLION. THE PURPOSE OF THIS SURVEY WAS TO DETERMINE THE SOUTH RIGHT OF WAY LINE OF ANGELA BOULEVARD BEING ALSO THE NORTH LINE OF LOT ONE IN EDDY STREET COMMONS MAJOR SUBDIVISION (SECTION ONE). MONUMENTATION FOUND ON THE PERIMETER OF SAID SUBDIVISION WAS USED TO ESTABLISH THE BOUNDARY OF LOT 1. BEARING BASE INDIANA STATE PLANE, EAST ZONE, (NAD83-2011) NO CLEAR POSSESSION LINE DISCREPANCIES WERE OBSERVED IN THE PERFORMANCE OF THIS SURVEY. SURVEYOR'S REPORT JOB No.: 265-084 W ANGELA 5000971310 1044 E ANGELA BLVD SOUTH BEND, IN 46617 ST JOSEPH COUNTY ASM Consultants, Inc. Professional Land Surveying and Engineering 16 E Wilson St - Batavia IL 60510 (630) 879-0200 - advanced@advct.com Professional Design Firm #184-006014 expires 4/30/2027 COPYRIGHT 2026, ASM CONSULTANTS, INC. ALL RIGHTS RESERVED.c FINAL SURVEY COMPLETED BOARD OF PUBLIC WORKS AGENDA ITEM REVIEW REQUEST FORM Date 10/02/2026 Name Zach Hurst Department DPW BPW Date 10/13/2026 Phone Extension 3057 Review and Approval Required Prior to Submittal to Board Diversity Compliance and Inclusion Officer Officer Name BPW Attorney Attorney Name Dept. Attorney Attorney Name Purchasing Check the Appropriate Item Type – Required for All Submissions Professional Services Agreement Contract Proposal Open Market Contract Amendment/Addendum Special Purchase, QPA Bid Opening Bid Award Req. to Advertise Title Sheet Quote Opening Quote Award Reject Bids/Quotes Proposal Opening C/O & PCA No. PCA Chg. Order, No. Traffic Control Resolution Other: Ease./Encroach Required Information Company or Vendor Name Colliers Engineering & Design, for Verizon Wireless New Vendor Yes If Yes, Approved by Purchasing No MBE/WBE Contractor MBE WBE Completed E-Verify Form Attached Yes No Project Name West Angela Small Cell Installation Project Number Funding Source N/A Account No. Amount Terms of Contract Purpose/Description Request approval of Encroachment Permit for new Small Cell (5G) antenna for Eddy Street Commons. Matt Ament – matta@terraltd.com For Change Orders Only Amount of Increase Decrease $ ($ ) Previous Amount $ Current Percent of Change: Increase Decrease % ( %) New Amount $ Total Percent of Change: Increase Decrease % ( %) Time Extension Amount: New Completion Date: