Tapping Area 120° <br />)n tal Axis <br />\� Vertical Axis <br />Core Drill on d <br />Seal Water Tight <br />Maximum 1" Protrusion df <br />Into Exist. Pipe <br />Sewer Main Flow <br />NOTES: <br />1. When "df" ) "D" use wye. <br />2. When "df" < "D" use manufactured saddle or if not available cut tap pipe per sketch. <br />SEWER TAPPING STANDARD <br />(NOT TO SCALE) <br />v Ex. Water Main <br />v <br />Proposed Main <br />II Pipe and <br />th Wedge <br />Action Restraints (Typ.) <br />Ex. )Main <br />Restrain all Pipe and <br />Fittings with Wedge <br />Action Restraints (Typ.) <br />Variable Length <br />NOTES. <br />1. Proposed main may pass over existing main if existing main is deep enough to provide adequate <br />clearance between main and cover over proposed main. <br />2. All pipe, fittings and valve joints shall be restrained with wedge action restraints. <br />CROSS OVER <br />(NOT TO SCALE) <br />Precast concrete <br />adjusting rings as <br />req'd. min. 4" - Top step to be 1'-6" <br />max. 12" 24"� below top of casting <br />24"/48" eccentric reducing cone <br />(See detail for alternate flat top <br />section) <br />Steel reinforced plastic <br />manhole steps <br />-------4�-- <br />Seal section joints with <br />MH FRAME & COVER <br />Precast concrete <br />butyl rope or 0-ring manhole sections Neenah Foundry model R-1772-C <br />seal in accordance w/ East Jordan Iron Works Model 1022 <br />ASTM C-443 (an 16" P o manhole frame with solid lid or equal. <br />outside joint wrap is I „ <br />also recommended) �' co 36 <br />\ p <br />As req'd. <br />% � O <br />Waterproof \\;\ <br />pipe boots - ;, 0 0 0 0 0 <br />r 000000000®0 <br />A-LOK brand 4" MIN. <br />0 0 0 0 0 0 <br />compression gaskets or 0 0 ®0 0 <br />rubber psx' waterproof repoured invert 0 <br />boots installed at the <br />time of manufacture. 14' <br />Precast conc. <br />base or integral 8" Precast base " <br />monolithic base �22 3/4 <br />7" <br />#4 bars O 12" o.c. 6" Compacted aggregate <br />both ways or equal 7241 <br />1" <br />/2 <br />SANITARY MANHOLE Sanitary Manhole Cover <br />(Not To Scale) <br />Vitrified Plug <br />Tee Shown 90° <br />out of Position <br />Single Outlet Use <br />or Tee Double 01 <br />may be Wye or <br />Flowable Fill <br />(Removable) <br />Encasement Min. <br />6" Around Stack <br />Pipe <br />30° Curve Along <br />Radius <br />L <br />6"" <br />PLAN <br />1." Slope <br />f,.r ft. <br />Compacted <br />I�I Tren ch Wall <br />�=1 I <br />Sewer Main Flow Flowable Fill <br />(Removable) at <br />C 4 w <br />Main Branch <br />Flowable Fill T a W4, <br />(R <br />emovable) atWye Branch a <br />VER TI CAL STACK <br />NOTES: SLANT STACK <br />1. Refer to INDOT Standard Specification Section 213 for removable Fowoble fill requirements. <br />2. Wye replacement: Remove old wye, trim existing as pipe required, install new wye and pipe and <br />connect to existing pipes with Fernco couplings. <br />VERTICAL AND SLANT STACKS <br />(NOT TO SCALE) <br />Mid -run Cleanout <br />End of Line Service Lateral <br />Clean -out Pipe (Typ.) t� <br />Sewer Main <br />8" Plug <br />Min. Tarred Felt Disk <br />Service Tap or Wye Grade <br />PLAN VIEW - SERVICE LINE 8"Min. <br />CLEAN -OUTS <br />Class "A" Conc. Pad <br />O.D. Jacket Plug 16", <br />8" Min. Thickness <br />45° Elbow <br />8" Plug <br />Tarred Felt Disk Same Size as <br />Min. \ Service Lateral <br />Grade \ <br />8+m M• - - -�- - <br />Class "A" Conc. Pad <br />O.D. Jacket Plug 16", Sanitary Service Wye <br />8" Min. Thickness `\ from Building <br />45° Elbow TYPICAL MID -RUN CLEAN -OUT <br />" 0 Rod \ Some Size as <br />for Lifting Service Lateral <br />45° Elbow <br />Depth Socket <br />\ - - <br />I.D. PLUG N Z a <br />Socket 'PAP' <br />12" Blocking Class <br />Conc. <br />Min. <br />TYPICAL END OF LINE CLEAN -OUT <br />NOTES: <br />1. Insert a manhole in service lateral if its length exceeds 150 ft. <br />2. The minimum service lateral size shall be 6" diameter, placed at a minimum slope of 0.611.. Larger <br />sized service laterals shall be installed according to the minimum slopes required by 317 IAC <br />3-6-12(a). <br />TYPICAL CLEAN -OUT <br />(NOT TO SCALE) <br />1" Compression Curb <br />Stop (Ball Valve) <br />Ball Type I--45° <br />Corporation Stop <br />(1" CC Threads x 1" <br />Copper Compression or <br />approved equal <br />Finish Ground <br />Cast iron access cap (4" - 2 hole) <br />X <br />Service shut-off box C) <br />(Tyler 95E or approved equal) <br />Shut-off box rod <br />Brick <br />E <br />Z3 <br />E <br />1 " Type "K" Service o <br />Pipe to Establishment CD <br />L� <br />1 " Type "K" Copper Service <br />(Perpendicular to Main) <br />For 1 " & 2" Services, a Twin Strap <br />Nylon or Epoxy Coated Saddle is Req'd. <br />Water Main <br />NOTES. <br />1. Service shut-off box shall be placed in the public right-of-way in grass between curb and sidewalk. <br />2. For a 2" service the corporation stop shall be located at 90° (level). <br />TYPICAL WATER SERVICE CONNECTION <br />(NOT TO SCALE) <br />SECTION 5 - WATER WORKS <br />Fire Hydrant (Restrained With <br />Wedge Action Restraints) <br />6" Gate Valve (Restrained With <br />Wedge Action Restraints) w/ Box <br />f <br />6" x Min. 13" i r in Po <br />IL <br />x _" x 6" Tee (Restrained O +� Hydrant Drainage Pft (See NM 2) <br />With Wedge Action Restraints) <br />6' x Min. 24" <br />0 - Fire Hydrant (Restrained With <br />Wedge Action Restraints) <br />6' x Min. 24" <br />6' Gate Valve (Resbained Wlih <br />Wedge Action RestrahKs) w/ Box <br />77- 6' x Min. 13" <br />x _" x 6" Tee (Restrained <br />With Wedge Action Restraints) <br />PLAN <br />NOTES: <br />1. Any subgrade disturbed beneath hydrant shall be thoroughly compacted or suitable <br />material shall be furnished, placed and compacted to provide a firm foundation for the <br />hydrant. <br />2. Hydrant drainage: To prevent freezing of the hydrant barrel if it were not drained, a <br />drainage pit 2'x2'x2' shall be excavated below the hydrant and filled with course gravel <br />or crushed stone mixed with sand to a depth of 6" above the hydrant opening, <br />providing sufficient aggregate void space to more than equal the volume of the barrel. <br />The drainage pit should neither be near, nor have a connection to a sewer. <br />3. Hydrant painting: Hydrants to be painted red, white and blue per manufacturers paint <br />specs. <br />4. All pipe, fitting and valve joints shall be restrained with wedge action restraints. <br />REF STD SPEC SEC 5-2.6 and 5-3.10 <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />\\\\\,\\\illlllfr!lii,��i <br />GI ST�jiO� t�s' <br />No. <br />• = PE10809510 ! ~ <br />`: STATE OF <br />S/ONAL-�.��`��\ <br />EFFECTIVE DATE: June 26, 2016 CITY OF SOUTH BEND <br />Item Revision Approved Date <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />STANDARD <br />FIRE HYDRANT ASSEMBLY 5-11 <br />WATER DISTRIBUTION <br />CONSTRUCTION NOTES <br />1. Water main, domestic and fire services, <br />materials and construction shall be in <br />accordance with the construction <br />standards of the City of South Bend, <br />AWWA Standards, and these Construction <br />Drawings. <br />2. Water main (4-inch diameter and larger) <br />shall be Class 50 ductile iron and pipe <br />fittings shall be Class 250 ductile iron <br />mechanical joint meeting the requirements <br />of the jurisdictional municipality and AWWA <br />C-110 or AWWA C-111. Water main joints <br />shall be bell and spigot with elostomeric <br />rubber gaskets. Joints shall be push -on <br />or mechanical, unless otherwise noted in <br />the plans. Mechanical joint fittings shall <br />be restrained by a mega -lug flange or <br />grip ring meeting the jurisdictional <br />municipality's latest specifications. <br />3. Water services (less than 4-inch diameter) <br />shall be Type 'K' Copper. <br />4. All gate valves shall be resilient sealed <br />and meet or exceed AWWA C509 (standard <br />for resilient wedge seated valves) and the <br />jurisdictional municipality standards. <br />Valves shall be rated for 200 psi working <br />water pressure with mechanical joints and <br />open left (counterclockwise). Valves shall <br />be anchored with restrained joints and <br />thrust blocking. Valves shall be installed <br />with standard cast iron valve boxes, plumb <br />over the wrench nut of the valve and to <br />finished grade, and have a round <br />plug -type cover embossed with "WATER". <br />5. Retainer glands shall be provided on all <br />valves and fittings in accordance with the <br />jurisdictional municipality standards. <br />6. Water service shall have a minimum cover <br />of 5 feet. <br />7. Water pipe shall be bockfilled in <br />accordance with the requirements as set <br />forth in the plans for rigid pipe beneath <br />pavement. <br />8. Maintain a minimum horizontal clear <br />separation 10 feet between water and <br />sewer pipes. Where water and sewer pipes <br />cross, maintain a minimum vertical clear <br />separation of 18 inches. If separation <br />cannot be met, the sewer pipe shall be <br />constructed of water grade pipe meeting <br />AWWA Standards for a distance of 10 feet <br />each side of the water pipe. At crossings, <br />one full length of water pipe shall be <br />installed so that the joints will be as for <br />from the sewer pipe as possible. <br />9. All tees, plugs, valves, dead ends, <br />reducers, and bends shall be installed with <br />a restrained joint in accordance with the <br />City of South Bend standards. <br />SANITARY SEWER CONSTRUCTION NOTES <br />1. All sewer main materials and construction <br />shall be in accordance with City of South <br />Bend Construction Standards and <br />Specifications. <br />2. Sanitary sewer fittings shall conform to <br />the requirements of ASTM D3034 with a <br />minimum wall thickness of SDR 35, as <br />defined in 7.4.1, and molded in one piece <br />with elostometric joints and minimum <br />socket depths as specified in Sections <br />6.2 and 7.3.2. PVC material shall have a <br />cell classification of 12454-8 and C <br />as defined in ASTM D 1784. <br />3. Contractor shall supply os-built record <br />drawings to the Owner and Engineer upon <br />completion of work. <br />4. Testing: The following tests are to be <br />performed. <br />a) Infiltration and exfiltration of water and <br />exfiltration of air under pressure. <br />b) Negative air pressure test for <br />manholes. <br />c) Deflection test for PVC pipes. <br />C <br />o-0 <br />W <br />° on -0> <br />E O D <br />_ <br />>> N <br />a <br />goo, <br />V <br />U <br />U <br />U <br />Q <br />-E <br />a� <br />oa)� C <br />o <br />w <br />Z <br />6 <br />O <br />Z <br />0 <br />U <br />= <br />>o <br />Zi <br />coZ <br />C Q <br />a <br />� ZOO U m <br />� <br />04 <br />�m�� Q o <br />> 0 V 7 0 <br />1. <br />U') U) -0 o <br />Q U <br />Q W <br />m <br />W W H <br />ad <br />ADO <br />Q H <br />Z W <br />W 3: W <br />H <br />ZOO <br />_ N <br />0 � <br />CL <br />W LJ <br />H <br />H <br />U <br />UJ <br />Q <br />W <br />0 <br />Z <br />O <br />U <br />H <br />Z <br />r�0 <br />w <br />LZ <br />w <br />LU <br />v7 <br />DRAWN BY: <br />PHW <br />DESIGNED BY: <br />JWL <br />PM REVIEW: <br />JWL <br />QA/QC REVIEW: <br />JWL <br />DATE: 07/29/2024 <br />SEAL: <br />W <br />_ No. 19400622 <br />o STATE OF <br />� a v <br />°`10\\\\ <br />SIGNATURE: <br />DATE: 07-29-2024 <br />SCALE: <br />HORZ: AS SHOWN <br />VERT: N/A <br />ACI JOB # <br />19-0582 <br />SHEET NO. <br />C791 <br />