Additional switches shall be added to the console when specified in this document. <br />Y N�( <br />3.7 AUDIBLE ALARM <br />An audible "Door Open" alarm shall be provided and installed in the driver's console. <br />It shall warn the driver if any compartment or module entry door on the vehicle is <br />open or ajar and the vehicle is placed into gear. <br />Y N <br />3.8 INTERCOM SYSTEM <br />A pre -wire shall be done with Department provided cables for a headset intercom <br />system. This must be verified by SBFD representative prior to installation. <br />Y N <br />3.8.1 Two (2) 22-gauge 9 wire cable shall be installed from the forward area of the <br />overhead squad bench cabinet to under the chassis radio/siren console. <br />3.9 BATTERIES <br />There shall be three (3) matching "No Maintenance" 12-volt batteries. They shall <br />total not less than 2,700 CCA with 180 minutes of reserve capacity. The batteries <br />shall be located in the OEM location under the driver step, below cab door, in a tray. <br />Add on step shall not hinder battery access. <br />A N_ <br />3.10 SEAT BASE INTERNAL 12 VOLT DC POWER <br />For certain standard internal 12-volt DC power circuits, there shall be circuit <br />protection provided by the use of manual reset breakers mounted in the outboard <br />panel of the driver's seat base. Potter & Brumfield 12 VDC breakers shall separately <br />protect the Radio Power circuit with a 40-amp breaker; the Constant Power circuit <br />with a 20-amp breaker; the Ford auto -throttle system with a 10-amp breaker; and the <br />Isolator circuit for the two (2) additional 12 VDC charging circuits required in 21-02- <br />00, a 20-amp breaker. Due to the potential danger associated with a separate <br />"battery hot" circuit, no exceptions to the above will be allowed. This Isolator circuit <br />includes a "low voltage" Schottky Diode to isolate medical equipment batteries from <br />any electrical loads. The diode shall be located and electrically connected between <br />the circuit breaker and the receptacles. Additional breakers may be added for <br />optional equipment such as power door locks, multiple radio installations or <br />compressor pumps. Additional radio leads including hot wire, ignition switched hot <br />wire and ground shall be provided. One set shall be in the front console and one set <br />in the rear action area. Each power lead shall have a 30-amp circuit breaker and <br />include one 12-volt hotwire and fuse holder with 30 amp. <br />3.11 POWER OUTLETS <br />Two (2) 12-volt power point style outlets shall be installed. One (1) shall be provided <br />in the forward section of the primary action area, above the countertop and one (1) in <br />the upper section of the ALS cabinet. <br />YKN_ <br />3.12 115 VOLT AC POWER <br />There shall be 115-volt AC wiring furnished. A three -wire system is used for <br />powering medical equipment, battery charger, etc. This electrical system, including <br />wiring and associated equipment, shall comply with AMD STD 009, 120V AC <br />Electrical Systems. The system shall incorporate a hospital grade GFI (Ground Fault <br />