City of South Bend Central Services Division <br />Fire Service, Inc./Wheeled Coach Ambulance <br />Specification <br />CABINET "J" DOOR <br />The door to cabinet "J" shall be a clear polycarbonate slider. The door handles <br />shall be self latching when closed. The frame for the door will be hinged at the <br />top for restocking and includes two gas strut hold opens. There shall be a self <br />latching handle integral to the frame for the latching of the restocking feature. <br />This door meets SAE J3058. <br />CABINET "L1" DOOR <br />The door to cabinet "L1" shall be a clear polycarbonate slider. The door handles <br />shall be self latching when closed. This door meets SAE J3058. <br />STANDARD MANDATORY MISCELLANEOUS EQUIPMENT <br />Unless otherwise precluded elsewhere in this specification the vehicle shall be <br />equipped with the following: <br />*One five pound fire extinguisher that is ABC dry chemical multipurpose with a <br />quick release bracket. <br />*No smoking oxygen equipment signs conspicuously place in the cab and patient <br />compartment. <br />*A back up alarm, audible warning device activated when the vehicle is shifted <br />into or moving in reverse. <br />In addition, the following items shall be shipped loose in the vehicle: <br />QUALITY ASSURANCE PROVISIONS <br />Defective components shall not be furnished. Parts, equipment, and assemblies, <br />which have been repaired or modified to overcome deficiencies shall not be <br />furnished without the written approval of the purchaser. Construction methods <br />utilized shall be in accordance with industry standards. Component parts and units <br />shall be manufactured to definite standard dimensions with proper fits, clearances <br />10070-0003 11 /05/20 <br />55 <br />