All cabinetry shall be sealed and molded to the floor with bright -anodized aluminum <br />molding. All interior materials, cabinetry, vinyl, foam, and installation used shall meet <br />or exceed FMVSS 302 requirements on flammability of interior materials (where <br />applicable). <br />8.4 COUNTERTOPS <br />The countertop in the primary action area of the patient compartment shall be non - <br />wood material, laminated with a minimum .028" stainless steel. The top shall be a <br />pan style with all seams sealed. <br />8.4.1 The countertop in the second action area of the patient compartment shall be <br />non -wood material, laminated with a minimum .028" stainless steel. The top shall be <br />a pan style with all seams sealed. <br />9.0 PATIENT COMPARTMENT LIGHTS <br />Patient compartment lighting shall consist of eight (8), LED dome lights with polished <br />bezels, switched from the action area control console. These lights shall be high <br />intensity LED with clear lenses. The lights shall be activated in separate banks of <br />four (4) lights each. There shall be one (1) bank over the squad bench and one (1) <br />bank over the primary cot. Two (2) switches shall be provided in the action area <br />console, each with high/offllow positions for independent operation of each bank. All <br />eight (8) LED dome lights shall be activated on "LOW" when either the curbside entry <br />door or rear entry doors are opened. There shall be a three -minute time delay <br />system activated by opening the entry doors. This system shall be battery hot and <br />turn the lights "OFF" at the three -minute pre-set time. No ceiling light shall protrude <br />into the patient compartment by more than 1.25". <br />9.0.1 THINLITE LIGHTS <br />Four (4) Trucklite model #80251C 18" LED panel lights, recessed into the ceiling <br />shall also be provided and installed. One (1) on/off position switch shall be provided <br />in the action area console. <br />9.0.2 An LED strip light shall be provided and installed in the primary action area. <br />This light shall have a manual "on/off' switch. <br />9.0.3 A rotary timer system shall be provided for the fluorescent lights. The system <br />shall be preset to automatically turn the lights off after activating. The timer shall be <br />from 5-60 minutes. <br />The patient compartment interior lights must meet the requirements set forth in AMD <br />Standard Test 016 Patient Compartment Lighting. <br />10.0 CEILING HEADLINER <br />47 <br />Y ✓N <br />Y ✓N <br />Y ✓N <br />Y-VIN— <br />Y_�,/N_ <br />Y A <br />