Laserfiche WebLink
§ 1.1.11.1 Consultants retained Under Basic Services: <br />J Structural Engineer: <br />Siqueira, LLC, Individual <br />Brian Siqueira <br />15635 Embers Drive <br />Mishawaka, IN 46545 <br />Telephone Number: (734) 341-3881 <br />Fax Nunnbcr: (574) 258-5224 <br />,2 Mechanical Engineer: <br />3 Electrical Engineer: <br />Prodecomm Engineering, General Corporation <br />Jim Sabinas <br />PO Box 910 <br />North Liberty, IN 46544 <br />§ 1.1.11,2 Consultants retained under Supplemental Services; <br />§ 1.1.12 Other Initial Information on which the Agreement is based: <br />I. it is understood that Mechanical HVAC will be limited as the facility will be a cold storage building, <br />except suspended gas fired units may be required to keep the space at a minimum of 45 to 50 degrees. <br />2. Site design is included, but will entail basic site utilities and on site storage of storm retention using swales <br />or drywells (Civil/Landscape/Site utilities, etc.). If a SWPPP plan is required or a comprehensive storm <br />retention assessment of the entire maintenance Facility Campus is required by the City of SB <br />engineering, additional fees Would be required. This would be assessed at the end of Phase I <br />Preliminary Design. <br />3. Schematic Design is based upon the Program sent to the Architect on 12.18.17. Minor changes or <br />adjustments from this Program can be incorporated into the Construction Documents. Major changes <br />may incur additional fees. <br />4.The building will be designed in accordance with the applicable Indiana Building Code, A submittal <br />to the local building official will be required for review /approval and for pulling a local permit <br />for construction, <br />5. All permit fees from local or state authorities to be paid by Owner/Contractor and are not included <br />in the design fee. <br />6. Variances, special uses, investigation, research and preparation of easements and/or rezoning are not included. <br />7. Hazardous materials investigation and abatement not included, <br />8. Energy and econornic analysis, lifecycle and energy cost analysis is not included.. <br />9. LEED Certification design and/or Green Building Certification or Commissioning is not included. <br />10, Disassembly and testing of existing equipment and systems is not included, <br />AIA Document B1011m-2017. Copyright@ 1974, 1978,1987, 1997, 2007 and 2017 by The American Institute of Architects. AH rights reserved. YVARNIM3:! <br />Init, ThW AW Document is pirotected lby U3, Copyright Law aind lirftrurlatjop al UnaLftherized roliprovfigctioin oirdishIbuflon offlMs AIA111 Docuirirwnt, <br />5 <br />or any 1podion of R, may result hi severe cW and a!�iflinflnall penalUes, and wHi I.w prosecuted to Me rnaximurn wftnt possIbW undoV the kmyy� This <br />document was produced by AIA software at 12:50:45 on 01 /1612018 under Order No. 2731703659 which expires on 01/1612019, and is not for resale, <br />User Notes: (389ADA1C) <br />