Laserfiche WebLink
Softener System Selected is: CT'M-150-PF Multi -tank System <br />The CTM will Provide (Each Unit): <br />Continuous Flow, gpm <br />59 @ 15 psi loss <br />It <br />Peak Flow, gpm <br />76 @ 25 psi loss <br />Min. Recommended Flow, gpm <br />:3.5 <br />Resin Quantity, ft3 <br />5 <br />Unit Capacity, kgr <br />148 @ 75 lbs Salt <br />Maximum Capacity, kgr <br />150 @ 75 Ibs Salt <br />Minimum Capacity, kgr <br />100 @ 30 lbs Salt <br />Tank Size, in. <br />18x65 <br />Tank Area, ft' <br />1.77 <br />Freeboard, in. <br />23 <br />Regeneration Data for Recommended Brine System (Each Unit)* <br />Brine Tank Size, in. <br />Max. Salt Load, Ilbs <br />Number of IRegens/Salt Fill <br />Salt Usage, lbs/Regen <br />System Requirements: <br />Operating Press., psi <br />Operating Temp., *F <br />Pipe Conn, in NPT... <br />Inlet, in. <br />Outlet, in. <br />Drain, in. <br />Shipping Weight, lbs... <br />Duplex <br />Triplex <br />Quad <br />Operating Weight, Ibs, <br />Duplex <br />Triplex <br />Quad <br />Overall Dimensions, in.... <br />Width x Height x Depth <br />Duplex <br />Triplex <br />Quad <br />2440 <br />6010 <br />8 <br />:75 <br />35-125 <br />40-120 <br />2 or 1.5 <br />2 or 1.5 <br />1.5 <br />881 <br />1304 <br />1950 <br />2116 <br />2779 <br />3687 <br />80 x 85 x 20 <br />108 x 85 x 20 <br />136 x 85 x 20 <br />�Backwash Flow Req'd, gpm 8 <br />Recond. Water Req'd, gals 272 <br />Total Regen Time, min. 76 <br />Voltage : 120 Volts AC, 50/60 Hz, 1 Ph <br />Full Load, Amps : < 1 <br />Generated by the Culligan CAARD Program Page 1 of 11 <br />