Hydraulic lines <br />& Plumbing: <br />Electronic <br />Manual <br />Spreader <br />Control: <br />All hydraulielines, pipes, hoses, and fittings shall beof <br />sufficient capacity to accommodate the volume of oil <br />without undue heating or turbulence in the system. A 2" <br />suction linewith a minimum SAE rating of 100-134 must be <br />used between the reservoir and the inlet of the pump. This <br />suction hose shall be secured on both ends via heavy duty <br />banding straps, radiator hose clamps unacceptable. All of <br />the pressure hoses, including the signal sensing lineto the <br />pump must have.swivel fittings on BOTH ends and have a <br />minimum SAE rating of 100-R2. Return lines and the case <br />drain line must have aminimum SAE rating of 100-131. <br />All fittings shall be JI C. Push on clamp fittings are not <br />acceptable. <br />Hydraulic lines shall be routed to minimize interference <br />with equipment and chassis components requiring periodic <br />servicing. Appropr+ate: support brackets, grommets, and tie <br />wraps shal I be provi ded to protect I i nes from abrasion, <br />cutting and impact damage. Hoses shall not be installed <br />near manifold or exhaust pipes so as to. be affected by <br />extreme heat. Thereshatl be no pipefitting used with any <br />high pressure lines. Any and all hydraulic quick disconnect <br />couplings used for spreader system and snow plow <br />reversing system shall be of the bulkhead mounted style <br />and be rigidly attached without the use of any hose clamp <br />arrangements (loose hose ends are NOT acceptable). Couplersto <br />be mounted to side of dump bed so they do not get covered with <br />material or broken. Dust cap for male ends and dust plug for <br />female ends must be attached to couplers. M axi mum distance <br />allowed between support clamps on all hydraulic hoses shall be <br />approximately 24". <br />The spreader control will utilize PWM technology to <br />control the variable feed and spread widths. The feed rate <br />knob will accommodate different sexttingswhilethe <br />spread width knob will also accommodate 9 settings. The <br />control head will have power switch with an indicator <br />lamp to provide status on the operation of the controller. Unit to be <br />mounted for safe use by driver. <br />Controller shall be Storm Guard Freedom 2 controller. <br />Spreader control shall have ability to be touch screen with usb data <br />download. <br />TEPwiring harness. <br />Screw on cap and plug set for motor sensor connection. <br />Detai I ed operators manual. <br />19 <br />SNO <br />YES NO <br />