My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Bids - Water Treatment Chemicals 2017-2018 - Chemrite, Inc.
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2017
>
Opening of Bids
>
Opening of Bids - Water Treatment Chemicals 2017-2018 - Chemrite, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2025 12:16:09 PM
Creation date
3/15/2017 2:35:08 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
3/14/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6. Accidental release measures <br />Personal precautions, <br />Keep unnecessary personnel away. Keep upwind. Do not touch damaged containers or spilled <br />protective equipment and <br />material unless wearing appropriate protective clothing. Avoid inhalation of vapors and contact with <br />emergency procedures <br />skin and eyes. Wear protective clothing as described in Section 8 of this safety data sheet. Local <br />authorities should be advised if significant spillages cannot be contained. <br />Methods and materials for <br />Keep combustibles (wood, paper, oil, etc.) away from spilled material. Should not be released into <br />containment and cleaning up <br />the environment. This product is miscible in water. Stop leak if possible without any risk. Dike the <br />spilled material, where this is possible. Clean up spills immediately by sweeping or shoveling up <br />the material. Do not return spilled material to the original container; transfer to a clean metal or <br />plastic drum. To clean up potassium permanganate solutions, follow either of the following two <br />options: <br />Option # 1: Dilute to approximately 6% with water, and then reduce with sodium thiosulfate, a <br />bisuiflte or ferrous salt solution. The bisulflte or ferrous salt may require some dilute sulfuric acid <br />(10% w/w) to promote reduction. Neutralize with sodium carbonate to neutral pH, if acid was used. <br />Decant or filter and deposit sludge in approved landfill. Where permitted, the sludge may be <br />drained into sewer with large quantities of water. <br />Option # 2: Absorb with inert media like diatomaceous earth or inert floor dry, collect into a drum <br />and dispose of properly. Do not use saw dust or other incompatible media. Disposal of all <br />materials shall be in full and strict compliance with all federal, state, and local regulations <br />pertaining to permanganates. <br />To clean contaminated floors, flush with abundant quantities of water into sewer, if permitted by <br />federal, state, and local regulations. If not, collect water and treat as described above. <br />Never return spills in original containers for re -use. For waste disposal, see Section 13 of the SIDS. <br />Environmental precautions <br />Do not allow to enter drains, sewers or watercourses. Contact local authorities in case of spillage <br />to drain/aquatic environment. <br />7. Handling and storage <br />Precautions for safe handling <br />Take any precaution to avoid mixing with combustibles. Do not get this material in your eyes, on <br />your skin, or on your clothing. Do not breathe dust or mist or vapor of the solution. Use personal <br />protective equipment as recommended in Section 8 of the SIDS. If clothing becomes <br />contaminated, remove and wash off immediately. Spontaneous ignition may occur in contact with <br />cloth or paper. When using, do not eat, drink or smoke. Good personal hygiene is necessary. <br />Wash hands and contaminated areas with water and soap before leaving the work site. Avoid <br />release to the environment. <br />Conditions for safe storage, <br />Store locked up. Keep container tightly closed and in a well -ventilated place. Store in a cool, dry <br />including any incompatibilities <br />place. Store away from incompatible materials (See Section 10). Store in accordance with NFPA <br />430 requirements for Class II oxidizers. <br />8. Exposure controls/personal protection <br />Occupational exposure limits <br />US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000) <br />Components <br />Type Value <br />Sodium Permanganate <br />Ceiling 5.mg/m3 <br />(CAS 10101-50-5) <br />US. ACGIH Threshold Limit Values <br />Components Type Value Form <br />Sodium Permanganate TWA 0.1 mg/m3 Inhalable fraction. <br />(CAS 10101-50-5) <br />0.02 mg/m3 Respirable fraction. <br />US. NIOSH: Pocket Guide to Chemical Hazards <br />Components Type Value Form <br />Sodium Permanganate STEL 3 mg/m3 Fume. <br />(CAS 10101-50-5) <br />TWA 1 mg/m3 Fume. <br />Biological limit values No biological exposure limits noted for the ingredient(s). <br />Exposure guidelines Follow standard monitoring procedures. <br />F2SP-20, Sodium Permanganate SDS US <br />Revision date: 20-March-2015 Issue dale: 20-March-2015 3 / 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.