Laserfiche WebLink
CASCADE ENGINEERING <br />Date: July 17, 2009 <br />P.O. No.: ISE15448 <br />Report No.:3182829GRR-001C <br />Reference No.: 09-0603-202466 <br />Page 3 of 11 <br />VOLUMETRIC LOADING CAPACITY TEST A: <br />Date Tested: 06/22/09 <br />Description of Samples: <br />Part Description: <br />Sample Condition: <br />Test Procedure: <br />Test Method: <br />Water Temp: <br />Number of Specimens Tested: <br />96 Cart <br />Production <br />Place the empty container on a scale and record the <br />weight. Place the empty container in a tank full of <br />water with a temperature of 59'F ± 9 `F. Fill the <br />container up to the rim and then place the container <br />on a scale. Record the difference from the full <br />container and the empty container. <br />62 ° <br />Two (2) Carts <br />Acceptance Criteria: <br />Accuracy of measurement must be ± 2 % of the measured capacity of the container. <br />Results: <br />Sample Description <br />Actual Capacity <br />% Difference <br />96 Universal <br />95.76 <br />-.25 <br />96 Automatic <br />95.75 <br />26 <br />The submitted samples meet the acceptance level criteria. <br />