HomeMy WebLinkAboutApproving a Contract Between Wastewater Treatment Plant E.R. Knapp & Co Amount $258,385.00ORDINANCE No. 5097 -69 Passed by the Common Council of the City of South Bend, August 11, �9 69 Presented by me to the Mayor of the City of South Bend, Approved and signed by August 12, 19 69 City Clerk of Common Council Clerk IDEAL tOJEWPRESS ORDINANCE NO. 5097 -69 AN ORDINANCE APPROVING A CONTRACT BETWEEN THE WASTEWATER TREATMENT PLANT OF SOUTH BEND, INDIANA AND E. R. KNAPP & COMPANY, ROCHESTER, INDIANA, FOR CONSTRUCTION AND INSTALLATION OF GAS MIXING EQUIPMENT MANUFACTURED BY RALPH B. CARTER COMPANY IN THE TOTAL AMOUNT OF $258,385.00. BE IT ORDAINED BY THE COMMON COUNCIL OF THE CITY OF SOUTH BEND, INDIANA: SECTION I: That the contract entered into between the Wastewater Treatment Plant and E. R. Knapp & Company, Rochester, Indiana, on the 21st day of July 1969, pursuant to advertising and receipt of bids, as the construction and installation is necessary in the opera- tion of said Wastewater Treatment Plant, is hereby approved and confirmed. SECTION II: This Ordinance shall be in full force and effect from and after its adoption and approval by the Mayor. 1st & 2nd READING 7 -76 -69 COMMITTEE OF THE WHOLE 8 -11 -69 PUBLIC HEARING 8 -11 -69 3rd READING8 -11 -69 NOT APPROVED REFERRED PASSED 8 -11 -69 M mbed r of the Common Council iN CLERK'S ULL - JUL 2 4 1969 ';ATHRYN L. BLOUGH 7Y CLERK, SOUTH BEND, IND: 0 July 23, 1969 TO: Members of the Common Council RE: Gas Mixing Equipment - Wastewater Treatment Plant FROM: John L. Hunter, Superintendent of Utilities The proposed Ordinance for $258,385 is for the necessary construc- tion, installation work, and gas mixing equipment to be done by E. R. Knapp &,.Company. We are attaching the report submitted by Clyde E. Williams & Associates, Incorporated, showing the analysis of bids, description and comparisons of the two systems which were bid, cost comparisons and recommendations. This will give you the "why's" on the bids and the systems. This system is needed to improve our digesters which are deficient in heating and mixing of sludge in this area. It conforms to our overall improvement plan for the plant as outlined in Clyde E. Williams' report of 1965. Due to the complexity of the program, we would appreciate the time necessary to explain the systems in more detail. We will be pleased to answer any questions necessary to satisfy yourselves that this is a needed improvement to our plant. Enclosures n� John L. Hunter r J ERK'S OV . JUL 2 4 1969 'CATHRYN L. BLOUSH Y CLERK, SOUTH BEND, IND. CITY OF SOUTH BEND REPORT ON GAS MIXING & HEATING EQUIPMENT FOR TWO (2) DIGESTER Analysis of Bids Low Bid based on Alternate "A" as submitted by E. R. Knapp & Co.,. -_$ Rochester, Indiana-------------------------------- Low Bid based on Alternate "B" as submitted by C & C Construction 'Co. , - -$ 3 °, Fort Wa ne,. Indiana---------- -- --- --- ----'-- - -' - -- Difference between lowest bids based on low for Alternate "A" and low for 7 Z 6 Alternate " B,'---------------------- ---- -------- - -= - -$ Description & Comparison of Two Systems: Alternate "A" Under Alternate . "A ",.the gas mixing equip- ment is as manufactured by Ralph B. Carter Company and is the patented full bore expendable piston type bubble, introducing a minimum amount of gas into the mass of sludge in order to produce a maximum turnover, pumpage. Approximately 7.5 c.f.m. divided by 0.54 (Volume of piston bubble) = 14 pulsations per minute in a 12" tube pumping approximately 1400 g.p.m.:with a tube velocity of 4 feet per second. Six 12" diameter tubes each equipped with expendable piston bubble type guns will be installed in each roof. For mixing without heating one compressor is used which operates two guns (Pumping rate+ 2800 g.p.m.), then two more guns in sequence and finally the other two guns until all six guns have been operated in sequences, completely around the digester. The normal horsepower requirement for gas mixing being two .(2) horsepower. For heating all six guns are operated si- multaneously with a total requirement of 5.,horsepower per digester. The bubble producer is like a cone fulcrum set into inverted cylinder. The size of opening for discharge of bubble being approxi- mately 2- 1/2 ".. Plugging or malfunction is extremely unlikely. Alternate "B" - Alternate "B" the gas mixing equipment is as manufactured by P.F.T. as is described as the "Pearth" system. Under this system,.approximately 300 c.f.m. is injected into a vertical 1 -1/2" diameter pipe (called a lance). On the sidewalls and near the lower end a number of small holes are drilled to let the compressed gas release.carrying upward with it a flow.- This system is an unrefined air lift of tthe an inefficient type,but should provide a pumpage rate' as high or higher than the Carter aero -gun. COMPARISONS (Carter) Aero -Gun 1) Six separate motorized gas valves (one for each gun) Class 1, Div.l Explosion proof. Any one valve may be isolated or malfunction but will not interfere with the others. 2) Two compressors (2 h.p. & 3 h.p.) are provided for each digester. System can function with one compres- sor under malfunction. 3) Piston bubble checked as operational since 1963 as maintaining a bubble as providing 3.5 to 4 f.p.s. velocities entirely through- out the pipe heating barrel to ensure cleansing velocity and inhibit caking under heating conditions. 4). Two flame traps and flame check provided to protect all gas lines from compres- sor area to roof. 5) steel, corrosion proof materials in pressure gauges,.and regulators. 6) Suction line to gas dome low velocity self- draining type (P.F.T.) Pearth 1) One -only rotary valve in which a malfunction means all gas mixing tubes are affected by the malfunction. 2) One compressor (25 h.p.) provided for each digester. System is inoperative if compressor malfunctions. 3) Indiscriminate emission of bubbles providing poor assurance of cleaning velocity throughout pipe heating barrel. 4). One flame arrestor on suction line only. 5) Appears to be standard bronze elements. 6) Suction line to gas dome drip - pot type, high velocity (pos- sibly could draw in-air if a leak occuried). COST COMPARISON Higher capital cost of Alternate "A" over Alternate "B " ---------------- $19,726.00 ANNUAL COST OF ALTERNATE "A" FOR ADDITIONAL INVESTED MONEY: AND ELECTNIM POWER: Assume lost. of interest of invested funds 5% per annum on $ 19,726.00 -------------- ------- $ (H.P. in winter = 80% of 10 =.8 H.P. for five months = .8 x5 - 40 H.P. months in spring, fall, and summer =.30% of 10 = 3 x7 = 21 H.P. months) 61 H.P. months K.W.H.'s = (61) (.746) (2.4) (30).= . 32,600 986.00 Annual Power ' Cost.@. 14/ K .W.H.----------------- --- --- --- 326.00 TOTAL ANNUAL COST $ 1,306.00 ANNUAL COST OF ALTERNATE "B" FOR ELECT" fG; POWER 50 H.P. running. continuously K.W.H.'s = (50) (.346) (24) (365) = ,325,000 Annual Power Cost @ 1 <2/ K.W.H.-------- ----- --- --------- $ 3,250.00 Annual Savings by Selecting Alternate "A" Aero - Hydraulic by Carter Company------------- - - - - - -- $ 1,944.00 Comments & Rdcommendations Alternate "A" Telephone calls were made to verify the Carter principle, the conclusions being that the piston bubble is as ciaimedr; and rela- tively trouble free. The equipment is of superior construction and design and has a factor':' of reliability of 4:1 on the compressors and 6:1 on the gas system over "Pearth" by P.F.T. We recommend the "Carter: aero- hydraulic system as being a satisfactory system of superior construction, reliability, less maintainence and much cheaper to operate. The difference in initial capital cost is more than justified. Inspection Trip & Conclusion A trip was made to "St' kne &.Hanover" Plants in Chicago by Mr. Louis Rague, Mr. Casimir Bp,and the writer. Though not yet operating at Chicago, the aero -guns by Carter were visually inspected as to construction and principle including compressors and components. The Pearth System, in operation in Chicago have caused considerable trouble in operation. The main trouble being high froth - ing which has forced sludge out and up around the floating covers. This problem in winter with freezing conditions has been quite serious. To minimize the problem,.the 15' lances were cut to 51. This did not cure the problem, but did reduce it. Now this system can only dis- turb the top surface of the digester and does not perform the service for which it was intended. The apparent cause of this frothing ap- pears to be pumping such high volumes of gas through the sludge media and stripping therefrom foaming elements. We recommend against the Pearth System, which in our opinion has a far greater hazard in opera- 7E lacks in reliability, and has a high operational cost. CLYDE E. WILLIAMS & ASSOCIATES, INC. Bernard E. Brennan fdIIUtritl# u Itpart August 11, 1969 Xv 24c Tomm u Mouncil of Up Cug of £►mall Jktux Your Committee of the Whole to whom was referred AN ORDINANCE APPROVING A CONTRACT BETWEEN THE WASTEWATER TREATMENT PLANT OF SOUTH BEND, INDIANA AND E. R. KNAPP & COMPANY, ROCHESTER, INDIANA, FOR CONSTRUCTION AND INSTALLATION OF GAS MIXING EQUIPMENT MANUFACTURED BY RALPH B. CARTER COMPANY IN THE TOTAL AMOUNT OF $258,385.00. Respectfully report that they have examined the matter and that in their opinion the Ordinance go to the Council as favorable. William W. Grown s Chairman