Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
CITY OF SOUTH BEND, INDIANA CONTRACTOR'S QUOTE FOR PUBLIC WORK PROJECT NAME: PROJECT NO. WWTP Server Room Fire Suppression System 124-038R QUOTES DUE Tuesday, February 11, 2025, by 9:00 a.m. Local Time. Sealed electronic bids are to be submitted by email to bpwbids(absouthbend in. gov. (Must be completed for all quotes. Please type or print) Date: February 11, 2025 Firm: Address: 302 Tyler Street City/State/Zip: Email Address: LaPorte, IN 46350 Larson -Danielson Construction Co., Inc. Telephone Number: ( 219 ) 362-2127 Chad Becker, PM cmbaldconstruction.com Brian Larson, President btl@ldconstruction.com Agent of Bidder (if Applicable): NIA Pursuant to notices given, the undersigned offers to furnish labor and/or material necessary to complete the public works project of: WWTP Server Room Fire Suppression System the City of South Bend, Indiana, in accordance with plans and specifications prepared by: The City of South Bend, Department of Public Works and dated Version 02/23/2022 for the sum of (enter the Total Quote as shown on the Proposal) One Hundred Seventy -Three Thousand, Eight Hundred Dollars ($173,800.00 (Enter Sum of Total Quote plus Alternates shown on Proposal) (Numerical) If alternative quotes apply, the undersigned submits a proposal for each in accordance with the notice. Any addendums attached will be specifically referenced at the applicable page. If additional units of material included in the contract are needed, the cost of units must be the same as that shown in the original contract if accepted by the City of South Bend. If the quote is to be awarded on a unit basis, th4ite ation of the units shall be shown on a separate attachment. By t; ,•,ELARSON-DANIELSON (Signature) SEAL CONSTRUCTION CO., INC. Brian T. Larson, President (Printed Name of Person Signing) The above quote is accepted this Subject to the following conditions: BOARD OF PUBLIC WORKS Elizabeth A. Maradik, President Gary A. Gilot, Member Murray L. Miller, Member Version 03/15/2024 ACCEPTANCE day of C Joseph R. Molnar, Vice President Briana N. Micou, Member Theresa Heffner, Clerk Page - 16 Public Works Quote QUOTE/PROPOSAL CITY OF SOUTH BEND PROJECT NAME WWTP Server Room Fire Suppression System PROJECT NO. 124-038R Tuesday, February 11, 2025, by 9:00 a.m. Local Time. Sealed electronic bids are to be submitted by email to QUOTES DUE bpwbids(a)southbend in.gov. Item No. Description Quantity Unit Unit Price Total Amount 1 Server room fire suppression 1 Lump Base Bid $172,480.00 system, materials and labor Sum 2 Alternate 1 - Clean agent suppression system 1 year inspection service. Firm: Larson -Danielson Construction Co., Inc. Address: 302 Tyler Street City/State/Zip: Alternate 1 $1,320.00 LaPorte, IN 46350 Telephone Number: ( 219 ) 362-2127 Fax Number: ( 219 ) 362-2848 By (Signature) Brian T. Larson, President (Printed Name of Person Signing) Version 03/15/2024 Page - 27 Public Works Quote LARSON DANIELSON Construction Company, Inc. QUALITY CONSTRUCTION SINCE 1908 302 Tyler Street - LaPorte, Indiana 46350 (219) 362-2127 • Fax (219) 362-2848 City of South Bend Public Works Project 124-038R Bid Clarification Sheet 02/ 1 1 /2025 1. Acknowledge 124-038R WWTP Server Room Fire Suppression System Quote Specifications document received on 01/10/2025. 2. The base bid includes an estimate cost of $1,000 for local, state & federal permit fees. Adjustment to the final cost may change once the final permit fee is determined. 3. Includes a Bid Bond of 5% for the Base Bid & any Alternates. 4. Excludes any MBE & WBE participation. S. Excludes all sales tax. A tax exemption form is required for credit, otherwise this will be additional to bid. 6. All work is figured for standard weekday working hours, M-F 7:00am — 3:30pm. Excludes Holidays & Premium Time. 7. Excludes all allowances. 8. Excludes any prevailing wage requirements. 9. Excludes demolition of any existing Fire Suppression System (if required). 10. Excludes any costs for the abatement of asbestos -containing materials. This is by the City of South Bend. 11. Excludes any cost for the State Variance Fee as this will be by the City of South Bend. 12. Excludes any cost for the Insurance Underwriter Approval. This will be by the City of South Bend. 13. Excludes any Fire Watch for the installation of materials/systems as this isn't required by the G.C. or Subcontractors for the new work. The City of South Bend is responsible for the Fire Watch of the existing building & equipment. To our knowledge this isn't necessary as the existing equipment is manned 24/7. 14. Excludes performance bond costs. 15. The start & completion date for this project will be agreed upon by the client & Larson Danielson based on the requirements for the Construction Design Release, Permitting, Lead Times of Materials, accessibility of Room 114 & Room 115 & scheduling of the project compiled from subcontractors & vendors. The duration of the project will be (120) calendar days from the date agreed upon. 16. The Description of Work on page 6 & 7 from the Notice to Bidders is the complete scope of work used for the furnishing of equipment, material, labor for the design & installation of the Server Room Fire Suppression System. 17. Excludes any 3D Modeling & Coordination. 18. Excludes tying into the existing SCADA system. 19. Excludes any/all costs associated with removal of an existing Fire Alarm System. We were informed by the City of South Bend that there isn't an existing Fire Alarm System. 20. Excludes any/all programming of the Fire Suppression System other than what is required by the Fire Suppression System Installer. 21. Excludes all data/network connections. 22. Excludes all HVAC temperature controls. Electrician to provide & install contactors & relays adjacent & wired in series with existing disconnect switches (on fan unit indoors) to lock our fans upon alarm. Electrician to also wire relay to shut down outdoor condensing units upon alarm activation. 23. Existing Mitsubishi units & piping to remain as is. As far as the dampers for the Mitsubishi system, there are none. They are a self-contained unit. The louver you see on the units in the pictures is what blows the air. That's why they need to be interlocked to the fire alarm system to shut them down when the alarm goes off. There is no way to put dampers on them. Excludes any work or warranty for the existing HVAC equipment/systems. Existing thermostats to remain on the wall as is. 24. No raised floor in protected space was identified. 25. Assumes that the existing restrooms facilities can be used by construction workers. 26. Excludes any responsibility of the existing double window unit for purposes of sealing the room. 27. Work not listed in the Description of Work or different to assumptions listed will be completed by approved Change Order. 28. Excludes working in, around & over equipment that is located in the construction area. There must be an adequate room for construction equipment, demolition, unloading & staging of materials, construction of new spaces & storage of tools at the immediate site location. All equipment is to be moved out & reinstalled once completed by others. www.ldconstruction.com Equal Opportunity Employer When the prospective Contractor is unable to certify to any of the statements below, it shall attach an explanation to this Affidavit. CONTRACTOR'S NON -COLLUSION AND NON -DEBARMENT AFFIDAVIT, CERTIFICATION REGARDING INVESTMENT WITH IRAN, EMPLOYMENT ELIGIBILITY VERIFICATION, NON-DISCRIMINATION COMMITMENT AND CERTIFICATION OF USE OF UNITED STATES STEEL PRODUCTS OR FOUNDRY PRODUCTS (Must be completed for all quotes and bids. Please type or print) STATE OF Indiana SS: LaPorte COUNTY The undersigned Contractor, being duly sworn upon his/her/its oath, affirms under the penalties of perjury that: 1. Contractor has not, nor has any other member, representative, or agent of the firm, company, corporation or partnership represented by him, entered into any combination, collusion or agreement with any person relative to the price to be bid by anyone at such letting nor to prevent any person from bidding nor to induce anyone to refrain from bidding, and that this bid is made without reference to any other bid and without any agreement, understanding or combination with any other person in reference to such bidding. Contractor further says that no person or persons, firms, or corporation has, have or will receive directly or indirectly, any rebate, fee, gift, commission or thing of value on account of such sale; and 2. Contractor certifies by submission of this proposal that neither contractor nor any of its principals are presently debarred, suspended, proposed for debarment, declared ineligible, or voluntarily excluded from participation in this transaction by any Federal department or agency; and 3. Contractor has not, nor has any successor to, nor an affiliate of, Contractor, engaged in investment activities in Iran. a. For purposes of this Certification, "Iran" means the government of Iran and any agency or instrumentality of Iran, or as otherwise defined at Ind. Code § 5-22-16.5-5, as amended from time -to -time. b. As provided by Ind. Code § 5-22-16.5-8, as amended from time -to -time, a Contractor is engaged in investment activities in Iran if either: i. Contractor, its successor or its affiliate, provides goods or services of twenty million dollars ($20,000,000) or more in value in the energy sector of Iran; or ii. Contractor, its successor or its affiliate, is a financial institution that extends twenty million dollars ($20,000,000) or more in credit to another person for forty-five (45) days or more, if that person will (i) use the credit to provides goods and services in the energy sector in Iran; and (ii) at the time the financial institution extends credit, is a person identified on list published by the Indiana Department of Administration. 4. Contractor does not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the Contractor subsequently learns is an unauthorized Version 03/15/2024 Page - 24 Public Works Quote alien. Contractor agrees that he/she/it shall enroll in and verify the work eligibility status of all of Contractor's newly hired employees through the E-Verify Program as defined by I.C. 22-5-1.7-3. Contractor's documentation of enrollment and participation in the E-Verify Program is included and attached as part of this bid/quote; and 5. Contractor shall require his/her/its subcontractors performing work under this public contract to certify that the subcontractors do not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the subcontractor subsequently learns is an unauthorized alien, and that the subcontractor has enrolled in and is participating in the E-Verify Program. The Contractor agrees to maintain this certification throughout the term of the contract with the City of South Bend, and understands that the City may terminate the contract for default if the Contractor fails to cure a breach of this provision no later than thirty (30) days after being notified by the City. 6. Persons, firms, partnerships, corporations, associations, or joint venturers awarded a contract by the City of South Bend through its agencies, boards, or commissions shall not discriminate against any employee or applicant for employment in the performance of a City contract with respect to hire, tenure, terms, conditions, or privileges of contract or employment, or any matter directly or indirectly related to contracting or employment because of race, sex, religion, color, national origin, ancestry, gender expression, gender identity, sexual orientation, or due to age or disability that does not affect that person's ability to perform the work. In awarding contracts for the purchase of work, labor, services, supplies, equipment, materials, or any combination of the foregoing including, but not limited to, public works contracts awarded under public bidding laws or other contracts in which public bids are not required by law, the City, its agencies, boards, or commissions will consider the Contractor's good faith efforts to obtain participation by those subcontractors certified by the State of Indiana as a Minority Business ("MBE") or as a Women's Business Enterprise ("WBE") as a factor in determining the lowest, responsible, responsive bidder. Contractors seeking the award of a City contract cannot be required to award a subcontract to an MWBE; however, they may not unlawfully discriminate against said MBE/WBE. On goal -eligible contracts, Contractors are required to either meet both MBE and WBE utilization goals or demonstrate that the Contractor has made good faith efforts to obtain participation from MBE and WBE subcontractors. A finding of noncompliance or a discriminatory practice shall prohibit that Contractor from being awarded a City contract for a period of one (1) year from the date of such determination, and such determination may also be grounds for terminating the contact to which the discriminatory practice or noncompliance pertains. 7. The undersigned Contractor agrees that the following nondiscrimination commitment shall be made a part of any contract which it may henceforth enter into with the City of South Bend, Indiana or any of its agencies, boards or commissions. Contractor agrees not to discriminate against or intimidate any employee or applicant for employment in the performance of this contract with privileges of employment, or any matter directly or indirectly related to employment, because of race, religion, color, sex, gender expression, gender identity, sexual orientation, handicap, national origin or ancestry. Breach of this provision may be regarded as material breach of contract. Version 03/15/2024 Page - 25 Public Works Quote I, the undersigned bidder or agent as contractor on a public works project, understand my statutory obligations to the use of steel products or foundry products made in the United States (I.C. 5-16- 8-1). I hereby certify that I and all subcontractors employed by me for this project will use steel products or foundry products made in the United States on this project if awarded. I understand I have an affirmative duty to notify the City in my bid that my proposal does not include the use of steel products or foundry products made in the United States. I understand it is my sole obligation and responsibility to provide a justification to the City, subject to review and approval, why the cost of United States made steel or foundry products is unreasonable. Prior to award and upon submission of bid which does not use steel products or foundry products made in the United States, the City, through its director of public works, shall make a determination if the price of United States made steel or foundry is unreasonable. I understand that violations hereunder may result in forfeiture of contractual payments. I hereby affirm under the penalties of perjury that the facts and information contained in the foregoing bid for public works are true and correct. Dated this 11th day of February , 20 25 IS LARSON-DANIELSON CONSTRUCTION CO., INC. Subscribed and sworn to before me this 11 th My Commission Expires February 11, 2032 County of Residence Larson -Danielson Construction Co., Inc. Contractor/Bidder (Fi ) 'g� , - Signature of Contractor/Bidder or Its Agent Brian T. Larson, President Printed Name and Title day of February 2025 Notary Public LaPorte CATHY A SALE mp•�fi�'= My Commission Expires February 11, 2032 Commission Number NP0679923 'p'�?;'• LaPorte County Version 03/15/2024 Page - 26 Public Works Quote OHIO FARMERS INSURANCE COMPANY Westfield Group 1 Park Circle, P O Box 5001, Westfield Center, Ohio 44251-5001 Conforms to Document A31 OTM - 2010 Bid Bond CONTRACTOR: SURETY: (Name, legal status and address) (Name, legal status and principal place of business) Larson -Danielson Construction Co., Inc. OHIO FARMERS INSURANCE COMPANY 302 Tyler St. 1 Park Circle, PO Box 5001 La Porte, IN 46350 Westfield Center, OH 44251-5001 OWNER: (Name, legal status and address) City of South Bend Department of Public Works 227 West Jefferson Blvd, Suite 130ON South Bend, IN 46601 BOND AMOUNT: Five Percent (5%) of the attached bid PROJECT: (Name, location or address, and Project number, if any) WWTP Server Room Fire Suppression System Project No. 124-038R The Contractor and Surety are bound to the Owner in the amount set forth above, for the payment of which the Contractor and Surety bind themselves, their heirs, executors, administrators, successors and assigns, jointly and severally, as provided herein. The conditions of this Bond are such that if the Owner accepts the bid of the Contractor within the time specified in the bid documents, or within such time period as may be agreed to by the Owner and Contractor, and the Contractor either (1) enters into a contract with the Owner in accordance with the terms of such bid, and gives such bond or bonds as may be specified in the bidding or Contract Documents, with a surety admitted in the jurisdiction of the Project and otherwise acceptable to the Owner, for the faithful performance of such Contract and for the prompt payment of labor and material furnished in the prosecution thereof; or (2) pays to the Owner the difference, not to exceed the amount of this Bond, between the amount specified in said bid and such larger amount for which the Owner may in good faith contract with another party to perform the work covered by said bid, then this obligation shall be null and void, otherwise to remain in full force and effect. The Surety hereby waives any notice of an agreement between the Owner and Contractor to extend the time in which the Owner may accept the bid. Waiver of notice by the Surety shall not apply to any extension exceeding sixty (60) days in the aggregate beyond the time for acceptance of bids specified in the bid documents, and the Owner and Contractor shall obtain the Surety's consent for an extension beyond sixty (60) days. If this Bond is issued in connection with a subcontractor's bid to a Contractor, the term Contractor in this Bond shall be deemed to be Subcontractor and the term Owner shall be deemed to be Contractor. When this Bond has been furnished to comply with a statutory or other legal requirement in the location of the Project, any provision in this Bond conflicting with said statutory or legal requirement shall be deemed deleted herefrom and provisions conforming to such statutory or other legal requirement shall be deemed incorporated herein. When so furnished, the intent is that this Bond shall be construed as a statutory bond and not as a common law bond. Signed and sealed this 11th day of F Davi Merkel, Vice President (Witness) .bruary 1ytrnTgo� 2025 c-rP-Mle4 sent CONSTRUCTION CO., I Larson -Danielson C s Co., Inc. (Principal) n (Seal) / Brian T. Larson, President (Title) Ctitiy OHIO FARMERS INSURANCE COMPANY _ Kathy Henrich (Witness) (Surety) (Seal) B4�.' 9G, _ Lisa Ebert, rney-in-Fact (Title) Printed with permission from The American Institute of Architects (AIA) and the Surety & Fidelity Association of America (SFAA) by Westfield Group . Westfield Group vouches that the language in the document conforms exactly to the language used in AIA Document A310T11 2010. General POWER. NO. 1304762 18 Power Westfield Insurance Co. of Attorney Westfield National Insurance Co. CERTIFIED COPY Ohio Farmers Insurance Co. Westfield Center, Ohio Know All Men by These Presents, That WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY, corporations, hereinafter referred to Individually as a "Core any" and collectively as "Companies," duly , organized and existing under the laws of the State of Ohio, and having Its principal office In Westfield Center, Medina County, Ohio, do by these resents make, constitute and appoint ONALD L. ROSENBAUM, CATHERINE E. MYERS, KATHY D. HENRICH, JENNIFER S. SALAT, LISA EBERT, RICHARD CARLSON, KILEA GIRTEN, MARISSA HAEMKER, KYLE ROSENBAUM, STACY RUTKOWSKI, JOINTLY OR SEVERALLY of LA PORTE and State of IN Its true and lawful Attorney(s)-In-Fact, with full power and authority hereby conferred In Its name, place and stead, to execute, acknowledge and deliver any and all bonds, recognizances, undertakings, or other Instruments or contracts of suretyship in any penal limit, and to bind any of the Companies thereby as fully and to the same extent as If such bonds were signed by the President, sealed with the corporate seal of the applicable Company and duly attested by Its Secretary, hereby ratifying and confirming all that the said Attorney(s)-In-Fact may do In the premises. Said appointment Is made under and by authority of the following resolution adopted by the Board of Directors of each of the WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY: "Be It Resolved, that the President, any Senior Executive, any Secretary or any Fidelity & Surety Operations Executive or other Executive shall be and Is hereby vested with full power and authority to appoint any one or more suitable persons as Attorney(s)-In-Fact to represent and act for and on behalf of the Company subiect to the following provisions: The Attorney-lh-Fact may be given full power and authority for and In the name of and on behalf of the Company, to execute, acknowledge and deliver, any and all bonds, recognizances, contracts, agreements of Indemnity and other conditional or obligatory undertakings and any and all. notices and documents canceling or terminating the Company's liability thereunder, and any such Instruments so executed by any such Attorney -in -Fact shall be as binding upon the Company as If signed by the President and sealed and. attested by the Corporate Secretary." "Be It Further Resolved, that the signature of any such designated person and the seal of the Company heretofore or hereafter affixed to any power of attorney or any certificate relating thereto by facsimile, and any power of attorney or certificate bearing facsimile signatures or facsimile seal shall be valid and binding upon the Company with respect to any bond or undertaking to which It Is attached." (Each adopted at a meeting held on February 8, 2000). In Witness Whereof, WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY have caused these presents to be signed by their National Surety Leader and Senior Executive and their corporate seals to be hereto affixed this 01st day of MAY A.D., 2024 . Corporate moouny n N„r„ WESTFIELD INSURANCE COMPANY seals,�"tyYA(p�, r P{1�N iN%,,,, •" 1�5Ptf � WESTFIELD NATIONAL INSURANCE COMPANY Affixed ��O,r"'yy'•• d'� �9�;:'" ':`;•G,p; "F" „• .•c( OHIO FARMERS INSURANCE COMPANY 16 �Illth1�' V :N.. SA:/l'il. Vim_ 03 sg0' fie: ' = State of 'I, County of Medina ss.: nl *,,.,,..,., ,•rtar.l....••'" By: GaryiWtupmr:rNatio, na urety Leader and Senior Executive On this 01st day of MAY A.D., 2024 , before me personally came Gary W. Stumper to me known, who, being by me duly sworn, did depose and say, that he resides In Medina, OH; that he Is National Surety Leader and Senior Executive of WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY, the companies described in and which executed the above Instrument; that he knows the seals of said Companies; that the seals affixed to said Instrument are such corporate seals; that they were so affixed by order of the Boards of Directors of said Companies; and that he signed his name thereto by like order. Notaal Seel +°'fit RNLI S ae Affixed )iCQ±: \111ii'•.. an �E State of Ohio County of Medina ss.: 4�al6 David A. Kotnik, Attorney at Law, Notary Public My Commission Does Not Expire (Sec. 147.03 Ohio Revised Code) I, Frank A. Carrino, Secretary of WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY, do hereby certify that the above and foregoing Is a true and correct copy of a Power of Attorney, executed by said Conpantes, which Is still in full force and effect; and furthermore, the resolutions of the Boards of Directors, set out in the Power of Attorney are In full force and effect. In Witness Whereof, I have hereunto set my hand and affixed the seals of said Companies at Westfield Center; Ohio, this 11th day of February A•D•,2025 �.N .Lrury ,I....lmuunr urnl ddao \a4UflA,yCF7► ' ,o'P4\oNAL y ��{�11tRiEkffps � / 1 Secretary h7� pro NtSEAL"m s Frank A. Carrino, Secretary �'+...nl�.�.e` ''yi '' .. 0 r %• . a• . of ^, .. :. 'w a q, 'nr411 - � rI1nIVNr . .. Illl„*1.111 • BPOAC2 (combined) (05-24) CITY OF SOUTH BEND EQUAL EMPLOYMENT OPPORTUNITY CONTRACTING PROVISIONS DIVERSITY UTILIZATION It is the policy of the City of South Bend to provide equal employment and business opportunity for all persons, partnerships, companies, and corporations in accordance with the rules, regulations and guidelines of the applicable federal, state and local laws. This policy of equal employment and business opportunity shall apply to every contractor or subcontractor bidding or holding a public contract with the City of South Bend. In furtherance of this policy, the following Equal Opportunity Clauses are hereby made a part of every construction contract entered into by the City of South Bend and all subcontractors entered into pursuant to any such contract and the bidder hereby certifies that it/he/she will abide by these provisions. The contractor will not discriminate against any applicant or employee because of race, color, religion, sex, national origin, or handicap. The contractor will take affirmative action to ensure that all applicants or employees are treated fairly and equitably. Such action shall include but not be limited to the following: hiring, up -grading, demotion or transfer, recruitment, advertising, lay-offs or termination, rates of pay or other forms of compensation and selection for training including apprenticeship programs. The contractor shall agree to post in conspicuous places available to employees and applicants, notices to be provided setting forth the provisions of the Non -Discrimination Clause. The contractor will, in all solicitations or advertisements for employees placed by or on behalf of the contractor, state that all qualified applicants will receive consideration for employment without regard to race, color, religion, sex, or national origin. The contractor will send to each labor union or representative of workers with which it / he/she has a bargaining agreement or other contract or understanding, a notice to be provided, advising the labor union or worker's representatives of the contractor's commitment under this section, and shall post copies of the notices in conspicuous places available to applicants and employees. The contractor will comply with all provisions of Executive Order 11246 (as amended by 11375) and of the rules, regulations and relevant orders of the Department of Labor. Subpart B --Contractors' Agreements Sec. 202. Except in contracts exempted in accordance with Section 204 of this Order, all Government contracting agencies shall include in every Government contract hereinafter entered into the following provisions: "During the performance of this contract, the contractor agrees as follows:" "(1) The contractor will not discriminate against any employee or applicant for employment because of race, color, religion, sex, or national origin. The contractor will take affirmative action to ensure that applicants are employed, and that employees are treated equally during employment, without regard to their race, color, religion, sex or national origin. Such action will include, but not be limited to the following: employment, upgrading, demotion, or transfer; recruitment or recruitment advertising; layoff or termination; rates of pay or other forms of compensation; and selection for training, including apprenticeship. The contractor agrees to post in conspicuous places, available to employees and applicants for employment, notices to be provided by the contracting officer setting forth the provisions of this nondiscrimination clause." "(2) The contractor will, in all solicitations or advertisements for employees placed by or on behalf of the contractor, state that all qualified applicants will receive consideration for employment without regard to race, color, religion, sex or national origin." Version 03/15/2024 Page - 17 Public Works Quote "(3) The contractor will send to each labor union or representative of workers with which i t/ he/she has a collective bargaining agreement or other contract of understanding, a notice, to be provided by the agency contracting officer, advising the labor union or workers' representative of the contractor's commitments under Section 202 of Executive Order No. 11246 of September 24, 1965, and shall post copies of the notice in conspicuous places available to employees and applicants for employment." "(4) The contractor will comply with all provisions of Executive Order No. 11246 of September 24, 1965, and of the rules and regulations, and relevant orders of the Secretary of Labor." "(5) The contractor will furnish all information and reports required by Executive Order No. 11246 of September 24, 1965, and by the rules, regulations, and orders of the Secretary of Labor, or pursuant thereto, and will permit access to his books, records, and accounts by the contracting agency and the Secretary of Labor for purposes of investigation to ascertain compliance with such rules, regulations, and orders." "(6) In the event of the contractor's noncompliance with the nondiscrimination clauses of this contract or with any of such rules, regulations, or orders, in this contract may be cancelled, terminated or suspended in whole or in part and the contractor may be declared ineligible for further Government contracts in accordance with procedures authorized in Executive Order No. 11246 of September 24, 1965, and such other sanctions may be imposed and remedies invoked* as provided in Executive Order No 11246 of September 24, 1965, or by rule, regulations, or order of the Secretary of Labor, or as otherwise provided by law." "(7) The contractor will include the portion of the sentence immediately preceding paragraph (1) and the provisions of paragraphs (1) through (7) in every subcontract or purchase order unless exempted by rules, regulations, or orders of the Secretary of Labor issued pursuant to Section 204 of Executive Order 11246 of September 24, 1965, so that such provisions will be binding upon each subcontractor or vendor. The contractor will take such action with respect to any subcontract or purchase order as the administering agency may direct as a means of enforcing such provisions including sanctions for noncompliance: Provided, however, that in the event a contractor becomes involved in, or is threatened with, litigation with a subcontractor or vendor as a result of such direction by the administering agency the contractor may request the United States to enter into such litigation to protect the interests of the United States." The applicant further agrees that it will be bound by the above equal opportunity clause with respect to its own employment practices when it participates in federally assisted construction work: Provided, that if the applicant so participating is a State or local government, the above equal opportunity clause is not applicable to any agency, instrumentality or subdivision of such government which does not participate in work on or under the contract. The applicant agrees that it will assist and cooperate actively with the administering agency and the Secretary of Labor in obtaining the compliance of contractors and subcontractors with the equal opportunity clause and the rules, regulations, and relevant orders of the Secretary of Labor, that it will furnish the administering agency and the Secretary of Labor such information as they may require for the supervision of such compliance, and that it will otherwise assist the administering agency in the discharge of the agency's primary responsibility for securing compliance. The applicant further agrees that it will refrain from entering into any contract or contract modification subject to Executive Order 11246 of September 24, 1965, with a contractor debarred from, or who has not demonstrated eligibility for, Government contracts and federally assisted construction contracts pursuant to the Executive Order and will carry out such sanctions and penalties for violation of the equal opportunity clause as may be imposed upon contractors and subcontractors by the administering agency or the Secretary of Labor pursuant to Part II, Subpart D of the Executive Order. In addition, the applicant agrees that if it fails or refuses to comply with these undertakings, the administering agency Version 03/15/2024 Page - 18 Public Works Quote may take any or all of the following actions: Cancel, terminate, or suspend in whole or in part this grant (contract, loan, insurance, guarantee); refrain from extending any further assistance to the applicant under the program with respect to which the failure or refund occurred until satisfactory assurance of future compliance has been received from such applicant; and refer the case to the Department of Justice for appropriate legal proceedings. * Corrected to read "invoked". In the original text the word "involved" was printed in error. Version 03/15/2024 Page - 19 Public Works Quote MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN The City of South Bend, Indiana has shown its commitment to addressing Minority and Women's Business Enterprise ("MWBE") participation in public contracting through the adoption of the City of South Bend Ordinance No. 10761-21. Persons, partnerships, corporations, associations, or joint ventures awarded a contract by the City of South Bend through its agencies, boards, or commissions shall not discriminate against any employee or applicant for employment in the performance of a City contract with respect to hire, tenure, terms, conditions, or privileges of employment, or any matter directly or indirectly related to employment because of race, sex, religion, color, national origin, ancestry, age or disability that does not affect that person's ability to perform work. Minority and Women's Business Enterprises are described in the Ordinance. A list of MBEs and WBEs (both certified and non -certified) can be found on the Indiana Department of Administration website: http://www.in.gov/idoa/. Documentation shall be provided with the bid that states the MBEs and WBEs that will be contracted, the dollar amount of the work that will be performed by the MBEs and WBEs on the project and the percentage of the dollar amount as it relates to the total bid amount by using Form MBE-1.0, MBE Utilization Plan, and Form WBE-1.0, WBE Utilization Plan. The City, its agencies, boards, or commissions requires the Contractor's good faith efforts to obtain participation by those Contractors classified as MBEs and WBEs. Failure to either meet the MBE and WBE goals or to provide evidence of good faith efforts for the bid will be grounds for rejecting a bid as non -responsive. Bidders shall demonstrate good faith efforts to have active participation from MWBEs on this Project and supply written documentation evidencing such efforts by using Forms MBE-2.0, Evidence of Good Faith Efforts and WBE- 2.0, Evidence of Good Faith Efforts and Forms MBE-2.1, MBE Contacted and WBE-2.1, WBE Contacted. Such documentation shall include, but is not limited to, the following items: a. A listing of all M/WBEs contacted including: (1) the name and address of the M/WBE; (2) the date of contact; (3) the type of contact (i.e., phone call, written solicitation, etc.); (4) the nature or type services or goods requested; and (5) the result of the contact. b. Written evidence of outreach and copies of email exchanges inviting and receiving bids, quotes or other responses from M/WBEs or other documentation of efforts to encourage and secure competitive responses from M/WBE and local businesses to be included in the benefits of building this Project. c. Written documentation of letters of introduction, invitations to forging majority/minority strategic alliances for capacity building, including but not limited to, mentoring, extensions of assistance on payroll, insurance, bonding, line of credit, technical skills or business skills. d. From time to time, projects will undergo a scope change prior to completion. This scope change will inevitably impact the Contractor's usage of MWBE's and the originally submitted Utilization Plan. It is the request of the City that when a project scope change occurs, the applicable Contractor shall utilize its best efforts to contract with M and W Subcontractors in a proportional manner as required by the scope change. All bidders are actively encouraged to reach out to the M/WBEs in St. Joseph County, Indiana, other Indiana counties, and Berrien County, Michigan to utilize a good faith effort to forge constructive and lasting business partnerships. Notwithstanding the foregoing, the award and performance of all City contracts shall comply with applicable federal, state, and local laws. The City reserves the right to request verification of goal implementation throughout the course of the project. If a goal exists, the winning respondent is contractually obligated to utilize the M/WBE's firms in a manner consistent with what was represented in its quote submission to the City. Deviations to the utilization plan must be requested in writing and approved by the City. The City reserves the right to initiate a change order in the amount equal to the difference in any subcontractor utilization if the utilization plan change is not approved. Version 03/15/2024 Page - 20 Public Works Quote CITY OF SOUTH BEND'S GUIDELINES FOR GOOD FAITH EFFORTS BY CONTRACTORS IN MEETING MWBE CONTRACT GOALS Under the City of South Bend's Minority and Women's Business Enterprise (MWBE) Inclusion Program Plan (COSB Inclusion Plan), the City of South Bend (the City) is authorized to set "contract specific" goals to increase MWBE participation in City contracts and procurements. MWBE participation goals are set based on availability of MWBE contractors within the City's geographic market area identified in the City's Disparity Study. For contractors bidding on a construction, services, supplies or equipment contract where goals have been set for all or parts of the project, below is information relevant to "good faith efforts" to meet the contract goal. When the City sets a contract goal, that means MWBE's are in fact available to perform work on the contract. Project bidders must try diligently to meet the goal. Failure to make a good faith effort may result in rejection of your bid as non -responsive to the contract. Good faith efforts means actions undertaken by a contractor to achieve a contract goal which, by their scope, intensity, and appropriateness to the objective, can be reasonably expected to fulfill the Program's goals (City's Inclusion Plan, Section 4.B., No. 21). A good faith effort is fully reviewable by the City. Where a contract goal is not met, contractors must provide as much information as possible to help the City assess the contractor's good faith efforts to achieve the goal. Inadequate proof of good faith efforts may result in a finding that the contractor was non -responsive, causing its bid to be rejected even if it is the lowest. Good faith efforts require active, aggressive efforts by the prime contractor to obtain the contract MWBE participation goal. Mere pro forma efforts are not good faith efforts. To satisfy the good faith efforts test: • A prime contractor may not reject a MWBE's bid solely because it is not the lowest bid received from subcontractors. If the MWBE's costs are reasonable and not excessive, the MWBE's quote or bid presumptively should be accepted on a contract requiring goals even if the MWBE's bid is not the lowest one received. However, if an MWBE's bid or quote is unreasonable or excessive, the prime contractor may reject the bid on that basis. The contractor has the burden of demonstrating the excessiveness or unreasonableness of the MWBE's bid or quote. Because the City must determine whether a MWBE quote was unreasonable or excessive, Contractors must provide the City with copies of each MWBE and non MWBE quote submitted to the bidder when a non-MWBE was selected over an MWBE. • A contractor may not reject a MWBE as being unqualified without sound reasons based on a thorough investigation of the MWBE's capabilities. If a prime contractor rejects a MWBE as unqualified, the Contractor must provide the City with good reasons for this. The MWBE's industry standing or membership in a specific group, organization, political or social affiliation (example: union v. non -union) is not a basis to reject the MWBE for lack of qualification. • The ability or desire of a prime contractor to perform the work of the contract with its own organization team does not relieve the prime contractor of the need to make good faith efforts to use MWBE sub contractors to meet the contract goal. Version 03/15/2024 Page - 21 Public Works Quote EXAMPLE: Total Project Estimate is $500,000. An MWBE goal of 10% is set for a specific part of the project, i.e., $50,000. Only one MWBE submits a quote to the prime Contractor, and it is $50,000. A non MWBE submits a quote of $45,000. Rejecting the MWBE bid may not meet the requirement of making a good faith effort to meet the contract goal because: 1) the MWBE quote is within the goal percentage and dollar amount set for MWBE participation on the project; 2) selection of the MWBE quote guarantees that the contractor meets the set goal and that its bid will be deemed responsive; and 3) the difference between the MWBE and non MWBE quotes is not significant in terms of the overall contract amount (i.e., 1 % of total contract). If the MWBE's quote is $53,000 and the non-MWBE bid is $50,000, it may yet not be demonstrative of a good faith effort to reject the MWBE solely because the MWBE's quote is not the lowest. The excess is not greatly significant to the total contract cost, and it could reasonably be expected to be made up elsewhere in the contract while guaranteeing full goal compliance. The above examples are illustrative only. The City will make a fair and reasonable judgment as to good faith efforts based on all information and documentation provided by bidders and taking into account the Quality, Quantity, and Intensity of the efforts made by a contractor to meet the contract goal. GOOD FAITH EFFORTS MATERIALS TO BE INCLUDED WITH BID If a contractor's bid does not meet the goal set for the contract, the contractor must submit evidence of good faith efforts with its bid so the City can determine whether the contractor is a responsive bidder. If the contractor's bid meets the MWBE goal, evidence of good faith effort is not required, but it would be prudent to include some evidence in case an error was made. The information required of a contractor who has not achieved the contract goal to show good faith efforts can be found in the South Bend Inclusion Program Plan at Section 8.B.3.d. as follows: (b) Where the bidder cannot achieve the contract goal, the bidder must provide proof of having made good faith efforts to meet the goal. In making this determination of whether to issue a goal waiver, the City will consider, at a minimum, the bidder's efforts to: (1) Solicit through all reasonable and available means (e.g., attendance at pre -bid meetings, advertising and written notices) the interest of all MWBEs in the scopes of work of the contract. The contractor shall provide interested MWBEs with timely, adequate information about the plans, specifications, and requirements of the contract to allow such firms to respond to the solicitation. The bidder must follow up initial solicitations with interested MWBEs. (2) Select portions of the work to be performed by MWBEs in order to increase the likelihood that the contract goal will be achieved. This includes, where appropriate, breaking out contract work items into economically feasible units to facilitate participation, even when the bidder would otherwise prefer to perform these work items with its own forces. It is the bidder's responsibility to make a portion of the work available to MWBEs and to select those portions of the work or material needs consistent with the availability of such firms to facilitate their participation. (3) Negotiate in good faith with interested MWBEs. Evidence of such negotiation includes the names, addresses, and telephone numbers of firms that were contacted; a description of the information provided regarding the plans and specifications for the work selected for subcontracting; and why agreements could not be reached. The bidder may not reject MWBEs as being unqualified without sound reasons based on a thorough investigation of their capabilities. That there may be some additional costs involved in finding and using MWBEs is not in itself sufficient reason for a bidder's failure to meet the contract goal, as long as such costs are reasonable. The ability or desire of a bidder to perform the work of a Contract with its own organization does not relieve it of the responsibility to make good faith efforts on all scopes of work within which subcontracting opportunities are available. (4) Make efforts to assist interested MWBEs in obtaining bonding, lines of credit, or insurance as required by the City or the bidder, where appropriate. (5) Make efforts to assist interested MWBEs in obtaining necessary equipment, supplies, materials, or related assistance or services, where appropriate. Version 03/15/2024 Page - 22 Public Works Quote Materials that should be submitted to support a contractor's good faith efforts include: • Copies of advertisements, notices, or solicitations from contractor to MWBE's-- to include date and time of issuance; • A list of all locations where advertisements or notices to MWBE's were placed or solicitations sent; • Copies of communication between contractor and MWBE's in response to contractor's advertisements, notices, or solicitations; • Proof of contractor's break-out of contract items into units feasible for performance by WMBE's; • Proof of communications between the contractor and MWBE regarding negotiations for agreements, and why agreement could not be reached, as stated more specifically in above Subsection (b) (3); • Proof of bids or quotes from MWBE's and those from non MWBE's when non MWBE's bid or quote is used; • Proof of efforts made by contractor to assist MWBE to participate in contract, where appropriate; and • Any other information tending to show that Contractor made active, aggressive efforts to meet the MWBE participation goal but despite good faith efforts was unable to do so. Version 03/15/2024 Page - 23 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN' FORM MBE-1.0 MBE UTILIZATION PLAN This completed form should be supplied with Bids that pertain to City of South Bend Public Works Projects involving MBE participation. It is the bidder's sole responsibility to verify whether any listed minority or woman business meets the MBE qualifications. ***Goals should be calculated based on the Base Bid only.*** Project Number: 124-038R Project Name: WWTP Server Room Fire Suppression System Bidder: N/A Total Bid Amount: N/A MBE Goal: 0% Page of Name &Address of MBE Primary Contact Person (Name/Telephone) Scope of Work to be Performed (Attach scope/schedule if you need additional space) Dollar Amount of MBE Component Percentage of Total Bid/Proposal N/A Submitted by: Print Name Signature ***Goals should be calculated based on the Base Bid only.*** Version 03/15/2024 Page - 28 Public Works Quote Date CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM WBE-1.0 WBE UTILIZATION PLAN This completed form should be supplied with Bids that pertain to City of South Bend Public Works Projects involving WBE participation. It is the bidder's sole responsibility to verify whether any listed minority or woman business meets the WBE qualifications. ***Goals should be calculated based on the Base Bid only.*** Project Number: 124-038R Project Name Bidder: N/A WWTP Server Room Fire Suppression System Total Bid Amount: N/A WBE Goal: 0% Page of Name & Address of WBE Primary Contact Person (Name/Telephone) Scope of Work to be Performed (Attach scope/schedule if you need additional space) Dollar Amount of WBE Component Percentage of Total Bid/Proposa I N/A Submitted by: Print Name Signature ***Goals should be calculated based on the Base Bid only.*** Version 03/15/2024 Page - 29 Public Works Quote Date CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM MBE-2.0 EVIDENCE OF GOOD FAITH EFFORTS This completed form should be included as part of the Bids documents related to City of South Bend Public Works Projects requiring Good Faith Efforts to obtain MBE participation. Project Number: 124-038R Date: Project Name: WWTP Server Room Fire Suppression System Bidder: Contact Person: Telephone: Address: City: State: Zip: Email: To determine whether a bidder has demonstrated good faith efforts to reach the MBE utilization goal set forth in the City of South Bend Public Works Project Specifications, the City and its agencies, boards, or commissions, REQUIRE ALL of the following Good Faith Efforts as listed in the table below*: N/A EVIDENCE OF GOOD FAITH EFFORTS MBE LIST(S): The bidder reviewed 1) the City of South Bend's Minority and Women Business Enterprise Inclusion Program Plan; 2) the list of certified MWBEs provided by the City; and 3) the Indiana Department of Administration list of Minority and Women Owned Businesses (both certified and non -certified) found N/A at: http://www.in.gov/idoa/. GOOD FAITH EFFORTS TO OBTAIN MBE PARTICIPATION The bidder shall initial each item below, as evidence of its good faith efforts to obtain MBE participation in the awarded contract. I affirm that I reviewed the City of South Bend's Minority and Women Business Enterprise Inclusion Program Plan and the Indiana Department of Administration's certified list of Indiana Minority and Women Business Enterprises, found on their website (hftp://www.in.gov/idoa). I affirm that I have made good faith efforts to select portions of the contract work to be performed by MBEs, including, where appropriate, breaking out contract work items into economically feasible units to facilitate MBE participation. I affirm that I have made good faith efforts to solicit through all reasonable and available means the interest of all MBEs in the scopes of work of the contract. I affirm that I attended all pre -bid meetings scheduled by the City of South Bend to inform MBEs of contracting and subcontracting opportunities. I affirm that I advertised in general circulation and/or trade association publications concerning subcontract opportunities and allowed MBEs reasonable time to respond to such advertisements. I affirm that I performed any and all necessary steps to provide written notices in a manner reasonably calculated to inform MBEs of subcontracting opportunities and allowed sufficient time for MWBEs to participate effectively. I affirm that I followed up on initial solicitations with interested MBEs. I affirm that I negotiated with interested MBEs in good faith, including providing such MBEs with adequate information about the plans, specifications and other requirements of the subcontract. I affirm that I have made good faith efforts to assist interested MBEs in obtaining bonding, lines of credit, or insurance as required by the City or the bidder, where appropriate. Version 03/15/2024 Page - 30 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM MBE-2.0 EVIDENCE OF GOOD FAITH EFFORTS I affirm that I have made good faith efforts to assist interested MBEs in obtaining necessary equipment, supplies, materials, or related assistances or services, where appropriate. I affirm that I did not reject any MBEs as unqualified without sound business reasons based on a thorough investigation of their capabilities. CONTRACT RECORDS: The bidder has maintained the following records for each MBE that has bid on the subcontracting opportunity: 1. Name, address, and telephone number; 2. A description of information provided by the bidder or subcontractor; and 3. A statement of whether an agreement was reached, and if not, why not, including any reasons for concluding that the MBE was unqualified to perform the job. Proper demonstration of Good Faith Efforts requires your initials next to all of the above boxes. Any omissions shall be considered grounds for rejection of the bid by the Board of Public Works. The City of South Bend reserves the right to request additional information. Version 03/15/2024 Page - 31 Public Works Quote L4 CITY OF SOUTH BEND r MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN y+ FORM WBE-2.0 EVIDENCE OF GOOD FAITH EFFORTS This completed form should be included as part of the Bids documents related to City of South Bend Public Works Projects requiring Good Faith Efforts to obtain WBE participation. Project Number: 124-038R Date: Project Name: WWTP Server Room Fire Suppression System Bidder: Contact Person: Address: City: Email: State: Telephone: Zip: To determine whether a bidder has demonstrated good faith efforts to reach the WBE utilization goals set forth in the City of South Bend Public Works Project Specifications, the City and its agencies, boards, or commissions, REQUIRE ALL of the following Good Faith Efforts as listed in the table below*: N/A EVIDENCE OF GOOD FAITH EFFORTS WBE LIST(S): The bidder reviewed 1) the City of South Bend's Minority and Women Business Enterprise Inclusion Program Plan; 2) the list of certified MWBEs provided by the City; and 3) the Indiana Department N/A of Administration list of Minority and Women Owned Businesses (both certified and non -certified) found at: http://www.in.gov/idoa/. GOOD FAITH EFFORTS TO OBTAIN WBE PARTICIPATION The bidder shall initial each item below, as evidence of its good faith efforts to obtain WBE participation in the awarded contract. I affirm that I reviewed the City of South Bend's Minority and Women Business Enterprise Inclusion Program Plan and the Indiana Department of Administration's certified list of Indiana Minority and Women Business Enterprises, found on their website (hftp://www.in.gov/idoa). I affirm that I have made good faith efforts to select portions of the contract work to be performed by WBEs, including, where appropriate, breaking out contract work items into economically feasible units to facilitate MWBE participation. I affirm that I have made good faith efforts to solicit through all reasonable and available means the interest of all WBEs in the scopes of work of the contract. I affirm that I attended all pre -bid meetings scheduled by the City of South Bend to inform WBEs of contracting and subcontracting opportunities. I affirm that I advertised in general circulation and/or trade association publications concerning subcontract opportunities and allowed WBEs reasonable time to respond to such advertisements. I affirm that I performed any and all necessary steps to provide written notices in a manner reasonably calculated to inform WBEs of subcontracting opportunities and allowed sufficient time for WBEs to participate effectively. I affirm that I followed up on initial solicitations with interested WBEs. I affirm that I negotiated with interested WBEs in good faith, including providing such WBEs with adequate information about the plans, specifications and other requirements of the subcontract. I affirm that I have made good faith efforts to assist interested WBEs in obtaining bonding, lines of credit, or insurance as required by the City or the bidder, where appropriate. Version 03/15/2024 Page - 32 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM WBE-2.0 EVIDENCE OF GOOD FAITH EFFORTS I affirm that I have made good faith efforts to assist interested WBEs in obtaining necessary equipment, supplies, materials, or related assistances or services, where appropriate. I affirm that I did not reject any WBEs as unqualified without sound business reasons based on a thorough investigation of their capabilities. CONTRACT RECORDS: The bidder has maintained the following records for each WBE that has bid on the subcontracting opportunity: 1. Name, address, and telephone number; 2. A description of information provided by the bidder or subcontractor; and 3. A statement of whether an agreement was reached, and if not, why not, including any reasons for concluding that the WBE was unqualified to perform the job. "Proper demonstration of Good Faith Efforts requires your initials next to all of the above boxes. Any omissions shall be considered grounds for rejection of the bid by the Board of Public Works. The City of South Bend reserves the right to request additional information. Version 03/15/2024 Page - 33 Public Works Quote CITY OF SOUTH BEND ` NIA MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM MBE-2.1 MBE CONTACTED This completed form should be supplied with Bids that pertain to City of South Bend Public Works Projects requiring Good Faith Efforts to contact MBEs. It is the bidder's sole responsibility to verify whether any listed minority or woman business meets the MBE qualifications. Attach additional pages if necessary. PAGE OF Project Number: 124-038R MBE Participation Goal Project Name: WWTP Server Room Fire Suppression System Bidder: By: (Signature) (Title) (Date) MBE Firm N/A Owner or Contact at MBE Firm Telephone: Fax: Email: TYPE OF WORK SOLICITED FOR THIS PROJECT: RESULTS OF CONTACT WITH THE MBE FIRM: MBE Firm N/A Owner or Contact at MBE Firm Telephone: Fax: Email: TYPE OF WORK SOLICITED FOR THIS PROJECT: RESULTS OF CONTACT WITH THE MBE FIRM: Version 03/15/2024 Page - 34 Public Works Quote CITY OF SOUTH BEND ` N/A MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM WBE-2.1 WBE CONTACTED This completed form should be supplied with Bids that pertain to City of South Bend Public Works Projects requiring Good Faith Efforts to contact WBEs. It is the bidder's sole responsibility to verify whether any listed minority or woman business meets the WBE qualifications. Attach additional pages if necessary. PAGE OF Project Number: 124-038R WBE Participation Goal Project Name: WWTP Server Room Fire Suppression System Bidder: By: (Signature) WBE Firm N/A Owner or Contact at WBE Firm Telephone: Fax: TYPE OF WORK SOLICITED FOR THIS PROJECT: RESULTS OF CONTACT WITH THE WBE FIRM: (Title) Email: WBE Firm N/A Owner or Contact at WBE Firm Telephone: Fax: Email: TYPE OF WORK SOLICITED FOR THIS PROJECT: RESULTS OF CONTACT WITH THE WBE FIRM: (Date) Version 03/15/2024 Page - 35 Public Works Quote BADGER Extra Stored Pressure Hand Portables Halotron- I The most effective clean agent with Class A, B and C fire capability When experiencing delays, downtime and interruptions associated with extinguishing agent clean-up is simply not an option, Halotron-1 is the choice. These quality fire extinguishers contain an extremely versatile and effective multi -purpose clean extinguishing agent able to address most fire risks typically found in commercial and industrial applications. It is ideally suited for computer rooms, data storage, telecommunication, robotics or any high-tech industrial process that requires an effective clean agent having an extended discharge range. Badger Extra Halotron-1 models are an environmentally acceptable Halon-1211 alternative. Larger sized models are suitable for use on Class A, B and C fires. • Chrome plated brass valves • Stainless steel handles andlevers • Large, easy -to -pull stainless steel ring pin • Heavy-duty machined aluminum nozzles • Steel cylinder and internal siphon tube • UL Listed and USCG Approved —Meets D.O.T. requirements • 12 year hydrostatic test intervals • 6 year warranty A B C Technical Data: BADGER Extra Halotron-I Stored Pressure Extinguishers MODEL 2.5 H113-2 5 HIB-2 11.5 HIB 15 HIB PART NUMBER 24563 24567 23082 23097 CAPACITY (lb.) 2.5 5 11 15.5 CAPACITY (kg) 1.1 2.3 5.0 7.0 UL FIRE RATING 2-B:C 5-B:C 1-A:10-B:C 2-A:10-B:C AGENTTYPE Halotron-1 Halotron-1 Halotron-1 Halotron-1 CYLINDER MATERIAL Steel Steel Steel Steel VALVE MATERIAL Plated Brass Plated Brass Plated Brass Plated Brass HANDLE/LEVER MATERIAL Stainless Steel Stainless Steel Stainless Steel Stainless Steel EXPELLANT Argon Argon Argon Argon Operating Pressure @ 70° F 100 100 125 125 TEMPERATURE RANGE (° F) -40 to 120 -40 to 120 -40 to 120 -40 to 120 TEMPERATURE RANGE (° C) -40.0 to 48.9 -40.0 to 48.9 -40.0 to 48.9 -40.0 to 48.9 AGENT FLOW RATE (lb/sec) 0.28 0.63 1.25 1.20 AGENT FLOW RATE (kg/sec) 0.13 0.29 0.57 0.54 NOM. DISCHARGE TIME (sec) 9 9 11 14 DISCHARGE RANGE (ft.) 6.0 to 10.0 9.0 to 15.0 9.0 to 15.0 12.0 to 18.0 DISCHARGE RANGE (m) 1.8 to 3.0 2.7 to 4.6 2.7 to 4.6 3.7 to 5.5 UNIT HEIGHT (in.) 14.88 15.25 16.19 17.13 UNIT HEIGHT (cm) 37.8 38.7 41.1 43.5 UNITWIDTH (in.) 6.13 6.13 8.35 8.75 UNITWIDTH (cm) 15.6 15.6 21.2 22.2 UNIT DEPTH (in.) 3 4.25 7.25 7.25 UNIT DEPTH (cm) 7.6 10.8 18.4 18.4 SHIPPING WEIGHT (lb.) 6.85 10.6 23 26.5 SHIPPING WEIGHT (kg) 3.1 4.8 10.4 12.0 USCG APPROVAL n/a Type B:C Size -I Type B:C Sized Type B:C Size -II BRACKET M B-250 MB-5 H B-11 H B-11 Included Optional Optional Optional This information is subject to change without notice. Badger Fire Protection disclaims any liability for any errors or misinterpretations of the information contained therein. Contact Badger Fire Protection for your local distributor for assistance. Distributed by: Badger Fire Protection 944 Glenwood Station Lane, Suite 303 Charlottesville,VA 22901 Tel.:434.964.3200 • Fax:434.964.3202 www.badgerfire.com SS B-012 May 2013 All Rights Reserved. BADGER Sv 500 SERIES FK-5-1-12 FIRE SUPPRESSION SYSTEM The Janus Fire Systems® Sv 500 Series Clean Agent Fire Suppression System utilizes FK-5-1-12 as the extinguishing medium. FK-5-1-12 is a clear, colorless and low odor liquid perfectly suited to protect high value assets in areas that may be normally occupied, in locations where clean-up of other agents is problematic, when storage space for a fire suppression agent is restricted, or when an electrically non-conductive agent is required. Each system consists of the following components and their associated accessories: 1. Agent Storage Components - Storage components consist of the cylinder assembly(s), which contains the FK-5-1-12 agent, and the cylinder bracket(s), which holds the cylinder assembly securely in place. 2. Agent Fluid Distribution Components - Distribution components consist of the discharge nozzles used to introduce the FK-5-1-12 into a protected hazard along with the associated pip- ing system used to connect the nozzles to the cylinder assembly. 3. Trim Components - Trim components complete the installation of the suppression system and consist of connection fittings, pressure gauge, low-pressure supervisory switch, electric valve actuator, and manual valve actuator. 4. Multi -Cylinder Arrangement Components - Multi -cylinder arrangement components consist of the pneumatic valve actuator(s), actuation check valve, vent check, actuation hose, and fit- tings required for a multiple cylinder (secondary) arrangement. 5. Supplemental Components - Supplemental components include the discharge pressure switch and manifold check valve. They supplement the core equipment or complete a specific multi -cylinder configuration. 6. Control Panel - This device monitors the condition of the electric actuator, detectors, warning devices, cylinder pressure, and any manual release and abort stations. All electric or electronic devices must connect to the control panel in order to function. 7. Detection and Alarm Devices - Detection devices coupled with manual release and abort stations maximize system efficiency while audible and visual alarm devices alert staff of alarm conditions. & @FM LISTED LISTED APPA°�° Typical Clean Agent System Layout Alarm Smoke Detector Warning Sign Discharge Nozzle Manual Release & Abort Control Panel Storage Cylinder Electric Valve Actuator Cylinder Valve Cylinder Bracket DS1258 Revised: 21-Dec-2023 © 2013 Janus Fire Systems. All rights reserved (6/2013) Janus Design Suite® and Janus Fire Systems® are registered trademarks of Janus Fire Systems. EQUIPMENT DESCRIPTION The FK-5-1-12 is stored as a liquid in cylinder assemblies designed specifically for the application and charged to a fill density of between 35 Ib/ft3 (561 kg/m3) and 70 Ib/ft3 (1121 kg/m3). To ensure optimal performance, each cylinder is superpressurized with dry nitrogen to 500 psi (34.48 bar) at 70°F (21°C). An identification label is affixed to the cylinder body indicating the fill quantity of FK- 5-1-12, charging pressure, date of fill, and fill station. The Sv 500 Series supports three cylinder capacities. Fire suppression systems utilizing FK-5-1-12 are designed to be discharged within 10 seconds into a room, area, or enclosure with the structural integrity to retain the agent. The FK-5-1-12 uniformly mixes throughout the protect area achieving a minimum concentration level in accordance with NFPA 2001 and/or agency listings. 40lb 22949 22 10.0 43 19.5 36 16.3 80lb 22950 41 18.6 81 36.7 65 29.5 130lb 22951 66 29.9 131 59.4 77 35.0 The cylinder assembly is composed of a cylinder, dip tube, and cylinder valve. Cylinder Valve --C. Dip Tub( Cylinder Bracket Cylinder Cylinder Valve: The automatic release of FK-5-1-12 is controlled by a forged brass, differential pressure operated cylinder valve connected to the neck of the cylinder. The valve assembly is shipped with an anti - recoil safety plug installed in the discharge outlet and chained to the cylinder valve. Dip Tube: A threaded, rigid dip tube extends from the cylinder neck down to its bottom. Cylinder: The light walled, welded seam cylinder is manufactured according to the requirements of the U.S. Department of Transportation (USDOT) and Transport Canada (TC) for compressed gas. Internal neck threads allow connection of the cylinder valve. The cylinder is designed for mounting in a vertical po- sition only. DS1258 Revised: 21-Dec-2023 Page 2 of 10 I Valve Actuation Connection Low -Pressure Supervisory Switch Pressure Gauge 1 Discharge Outlet Anti -Recoil Pilot Actuation Safety Plug Port Pipe Plug Safety Cap Rupture Disc Low-rressure Supervisory Switch CYLINDER MOUNTING The cylinder valve has four key features: Valve Actuation Connection: Athreaded connection located on top of the cylinder valve serves as the at- tachment point for the electric (primary) or pneumatic (secondary) valve actuator. Pressure Gauge: A pressure gauge is affixed to the cylinder valve exterior as shown on the cylinder valve assembly diagram. Low -Pressure Supervisory Switch: A low-pressure supervisory switch is mounted to the cylinder valve as shown on the cylinder valve assembly diagram. Rupture Disc: A frangible rupture disc is fitted to the cylinder valve body. It functions as an emergency re- lief device in the event of excessive pressure within the cylinder. Its rupture point is between 850 psi (58.6 bar) and 1000 psi (68.9 bar). The cylinder valve has two outlets: Discharge Outlet: A 1 1 /4 in (32 mm) FNPT connection serves as the connection point for discharge piping. Pilot Actuation Port: A 3/8 in (10 mm) FNPT con- nection (shipped with a removable plug) provides a means of applying actuation pressure to the second- ary cylinder(s) or, in a single cylinder system, the dis- charge pressure switch. The port is pressurized only during the 10 second discharge period. Wall Mount Cylinder Bracket Assembly (P/N 18595) Cylinder stability is ensured by the cylinder bracket as- sembly, consisting of one strap and rail with accompany- ing bolts, nuts, and washers. The rail is slotted for ease of mounting with fasteners provided by the installer. 23.83 605 36.56 929 53.0 1346 19.93 506 32.67 830 49.10 1247 13.63 346 15.75 400 30.75 781 10.0 254 10.0 254 10.0 254 11.9 302 11.9 302 11.9 302 DS1258 Revised: 21-Dec-2023 Page 3 of 10 1 1/4" Elbow (32 mm) Recommended f r (Provided by Installer) M1ti 11/4" rJ Discharge Nipple•X Outlet (32 mm) Recommended ti (Provided by Installer) 1 1/4" Union - (32 mm) Recommended (Provided by 1 1/4" Installer) Nipple (32 mm) Pressure Recommended Gauge (Provided by Affixed to Installer) Cylinder Valve Anti -Recoil Safety Plug Shipped with Cylinder Valve ti Cylinder Valve Assembly with Trim Components Manual Valve Actuator (PIN 17001) Electric Valve Actuator (w/ Supervisory Limit Switch - P/N 20722) .1 (w/o Supervisory Limit Switch- P/N 18481) Rupture Disc Affixed to / Cylinder Valve J/ Pilot Actuation Port Low -Pressure Supervisory Switch Affixed to Cylinder Valve CYLINDER VALVE FEATURES 36" (914 mm) Leads Discharge Outlet / Connections The discharge outlet of the cylinder valve is a 1 1/4 in (32 mm) female NPT connection that is used to attach the cylinder to the discharge piping system. The suggested pipe configuration is shown to the left. Pipe and fittings are to be supplied by the installer. Low -Pressure Supervisory Switch (P/N 22858) The low-pressure supervisory switch continuously moni- tors the pressure of the cylinder. The contact configu- ration is single pole, single throw (SPST) with contacts rated 1.5 Amps at 24 VDC. Should the cylinder pressure drop to approximately 440 psi (30.3 bar), the switch con- tacts will close transmitting a signal to the system control panel. It is mounted to the cylinder valve and cannot be replaced while under pressure. Pressure Gauge (P/N 22942) NFPA2001 mandates a pressure gauge for each cylinder as a method of visually monitoring the internal pressure condition of the cylinder assembly. The pressure gauge is mounted to the cylinder valve and cannot be replaced while under pressure. DS1258 Revised: 21-Dec-2023 Page 4 of 10 TRIM COMPONENTS Trim components are required to operate the clean agent cylinder(s). 1/2" (15 mm) NPS Female \ Conduit Hub Knurled with 40" (1016 mm) leads Swivel Nut Emergency Release Button Electric Valve Actuator w/ Supervisory Limit Switch' (P/N 20722) The electric valve actuator attaches to the primary cylinder at the valve actuation connection and is utilized to automati- cally open the cylinder valve upon receipt of a signal from the control panel or other source. It operates between 17 and 30 VDC and consumes 500 mA (.5 Amps) at 24 VDC nominal with a maximum supervisory current of 30 mA (0.03 Amps). The electric valve actuator body is steel construction with a brass knurled swivel nut and a stainless steel actuation pin that depresses the valve core when energized. The limit switch contacts are normally closed when the actuator is not installed onto the cylinder valve and open when the actuator is fully installed onto the valve actuation connection at the top of the cylinder valve. Manual Valve Actuator (P/N 17001) An optional manual valve actuator attaches to the top of the electric valve actuator and provides a means to manually open the cylinder valve. The manual valve actuator consists of a brass body, stainless steel actuation pin, and steel safety ring pin. To discharge the primary cylinder manually, the ring pin is re- moved and the emergency release button is depressed forc- ing the pin in the electric valve actuator to depress the valve core of the cylinder valve. All other connected cylinders will be opened pneumatically. MULTI -CYLINDER ARRANGEMENT COMPONENTS Up to 16 cylinders (1 primary and 15 secondary) may be installed in a single arrangement, with a maximum length of 100 ft (30.48 m) of pilot actuation hose or tubing extending from the primary cyl- inder in either direction. Atypical arrangement is shown below. Discharge Variable Size Pilot Actuation Pressure Switch Flex Hose Mid Line Tee (P/N 97428) (P/N Variable) (P/N 18622) Male NPTZ anual Adapter -� Actuator Pneumatic (P/N 18625) 17001) Valve Actuator (P/N 17019) 1 1/4" (32 mm) +I Manifold Check Valve _ (P/N 18547) Electric Valve Actuator (P/N 20722) Pilot Actuation Adapter (P/N 18624) _ Pilot Actuation Check Valve (P/N 18560) 16" Flex Hose (406 mm) (P/N 18648) Discharge Manifold (Provided By Installer) Pilot Male NPT Actuation Adapter End Line Tee (P/N 18625) (P/N 18611) Primary Secondary Secondary Secondary Secondary Cylinder Cylinder Cylinder Cylinder Cylinder Typical Primary and Secondary Cylinder Arrangement Vent Check (P/N 10173) DS1258 Revised: 21-Dec-2023 Page 5 of 10 Effective January 1, 2016, NFPA 2001 requires that the removal of an electric actuator from the agent storage container discharge valve that it controls shall result in an audible and visual indication of system impairment at the system releasing control panel. 1/4" (8 mm) FNPT . 1- .. Knurled Nut I 1/4" (8 mm) MNPT 1/4" (8 mm) 37° Male JIC 1/4" (8 mm) MNPT 1/4" (8 mm) FNPT 3/8" (10 mn MNPT 1/4 37' 1/4" (8 mm) MNNPTT 1/4° 37' Male JIC Pneumatic Valve Actuator (P/N 17019) On multiple cylinder systems the electric valve actuator will open the primary cylinder and then, in a rapidly oc- curring sequence, the pneumatic valve actuator(s) will open all other cylinders using pressure from the primary cylinder. A pneumatic valve actuator attaches to the valve actu- ation connection of each secondary cylinder. It receives pressure from the pilot actuation port of the primary cyl- inder through the pilot actuation check valve. It is brass with a brass piston and pin. Vent Check (P/N 10173) The vent check is a safety device with 1/4 in (8 mm) MNPT threads that is to be installed in the pilot actuation line downstream of the pilot actuation check valve. It is used to bleed off pressure that may accumulate in the pilot actuation hose or piping minimizing the chance of inadvertent pressurization of the pneumatic actuators or discharge pressure switch. Pilot Actuation Check Valve (P/N 18560) A 1/4 in (8 mm) MNPT by 37' male JIC check valve is installed in the pilot actuation port of the primary cylinder valve with direction of flow OUT of the valve. When the valve opens, pressure will be directed through the pilot ac- tuation check valve to the pneumatic valve actuators on the secondary cylinders. The purpose of the pilot actuation check valve is to ensure the pneumatic actuator(s) remain pressurized for the entire discharge period. Pilot Actuation Adapter (P/N 18624) A 3/8 in (10 mm) MNPT by 1/4 in (8 mm) FNPT brass pipe bushing is fitted into the pilot actuation port of the primary cylinder to facilitate the attachment of the pilot actuation check valve. Pilot Actuation Mid Line Tee (P/N 18622) A 1/4 in (8 mm) 37' male JIC by MNPT brass branch tee is utilized to attach the pilot actuation line to the pneu- matic valve actuator. Male NPT Adapter (P/N 18625) A 1/4 in (8 mm) 37o male JIC by MNPT adapter fits into the pilot actuation end line tee of the final secondary cyl- inder to facilitate the attachment of the pilot actuation line. It also may be utilized to allow the attachment of flex hose to the discharge pressure switch. DS1258 Revised: 21-Dec-2023 Page 6 of 10 1/4" (I FN L 18648 18649 18650 18651 nm) r Pilot Actuation End Line Tee (P/N 18611) A 1/4 in (8 mm) FNPT by MNPT brass branch tee mounts to the final pneumatic valve actuator to facilitate attach- ment of the vent check to the pilot actuation line. Flex Hose (P/N See Chart) Flex hoses are 3/16 in (7 mm) Teflon® lined stainless steel wire braided hoses of varying lengths with 1/4 in (8 mm) 37o female JIC flare fittings. They are utilized to in- terconnect cylinders when a multi -cylinder arrangement is required. A 1/4 in (8 mm) 37o male JIC flare x male JIC flare adapter (P/N 18777) is available to connect lengths of flex hose together. 16 in (406 mm) 24 in (610 mm) 34 in (864 mm) 40 in (1016 mm) SUPPLEMENTAL COMPONENTS Supplemental components complete various system arrangements. 5 �2" (133 mm) DS1258 Revised: 21-Dec-2023 r 1/4" (8 mm) FNPT Pipe Connection k 1 1/4" (32 mm) FNPT Discharge Pressure Switch (P/N 97428) The discharge pressure switch is used in the system to provide positive indication of agent discharge and to initi- ate the shut down of equipment that may deplete agent concentration. The pressure switch is a single pole, dou- ble throw (SPDT) switch with contacts rated 15 Amps at (20 mm) 125/250/480 VAC and 0.5 Amps at 125 VDC. It has a IT Conduit NEMA 4X and IP66 enclosure. inn—tinn Manifold Check Valve (P/N 18547) In a multiple cylinder arrangement where the secondary and primary cylinders share a common manifold or in a main / reserve arrangement, a 1 1/4 in (32 mm) FNPT manifold check valve must be placed between the dis- charge outlet of each cylinder and the discharge mani- fold to prevent back flow from the manifold should the system be inadvertently discharged when one or more cylinders are disconnected for maintenance. The take- out for the valve is 1.375 in (35 mm). Page 7 of 10 DISCHARGE NOZZLES Discharge nozzles (4, 6, or 8 ports) are used to uniformly distribute the FK-5-1-12. They are performance tested to ensure that the agent is discharged within 10 seconds and properly dis- persed throughout the protected area. Maximum nozzle height for a protected space is 18 ft 4 in (5588 mm) per tier of nozzles. Additional tiers are required for heights greater than 18 ft 4 in. 39' Discharge Nozzle Cut View Discharge Nozzle Top View 3?S 360' Radial Nozzle (8 Port) 180° Sidewall Nozzle (6 Port) 90' Corner Nozzle (4 Port) 39' [11.89m] N 360' Radial Nozzle (8 Port) Arrangement 39' 180' Sidewall Nozzle (6 Port) Arrangement 24' [7.32m] \ 33.94' [10.34m] MAXIMUM 24' [7.32m] \ /5' \\\ 90° Corner Nozzle (4 Port) Arrangement 1' [305mm] MAXIMUM 1' [305mm] MAXIMUM DS1258 Revised:21-Dec-2023 Page 8 of 10 19529 19522 19515 20445 20438 20431 3/8 in (10mm) 1.436 36.5 19530 19523 19516 20446 20439 20432 1/2 in (15 mm) 1.722 43.7 19531 19524 19517 20447 20440 20433 3/4 in (20 mm) 1.926 48.9 19532 19525 19518 20448 20441 20434 1 in (25 mm) 2.176 55.3 19533 19526 19519 20449 20442 20435 1 1/4 in (32 mm) 2.500 63.5 19534 19527 19520 20450 20443 20436 1 112 in (40 mm) 2.689 68.3 19535 19528 19521 20451 20444 20437 2 in (50 mm) 3.100 78.7 Ordering Instructions: Specify the Nozzle P/N followed by a dash and the three digits representative of the drill code as provided by the Janus Design Suite® software. Example: 19529-XXX = Nozzle: 360°, 318" (10 mm), Brass (with drill code as specified) CHEMICAL PROPERTIES OF FK-5-1-12 FK-5-1-12 is formed from the elements carbon, fluorine and oxygen [CF3CF2C(0)CF(CF02 - dode- cafluoro-2-methyl pentan-3-one]. The primary extinguishing mechanism of FK-5-1-12 is heat ab- sorption, with a secondary chemical contribution from the thermal decomposition of FK-5-1-12 in the flame. FK-5-1-12 leaves no residue and is safe for use in occupied spaces. Ozone Depletion Potential (ODP) — FK-5-1-12 is a highly fluorinated ketone containing no chlo- rine or bromine. As a result, the ODP for FK-5-1-12 is zero, meaning it has no effect on strato- spheric ozone. Global Warning Potential (GWP) — FK-5-1-12 has an atmospheric lifetime of only 0.014 years. The global warning potential for all practical purposes is negligible. SAFETY CONSIDERATIONS Although the EPA Significant New Alternative Program (SNAP) lists FK-5-1-12 as acceptable for occupied spaces, NFPA Standard 2001 and SNAP list the following guidelines for human exposure: FK-5-1-12 has a NOAEL' of 10.0% v/v with no restrictions. The maximum exposure time shall not exceed five (5) minutes. Avoid any exposure greater than 10% v/v (LOAEL2). The discharge of FK-5-1-12 into a hazard may reduce visibility for a brief period. When FK-5-1-12 is exposed to extremely high temperatures, the by-product Hydrogen Fluoride (HF) will be formed. FK-5-1-12 systems are designed to discharge in 10 seconds or less in order to minimize the amount of HF formed. The Safety Data Sheet (SDS) on FK-5-1-12 should be read and understood prior to working with the agent. A cylinder containing FK-5-1-12 should be handled carefully. The anti -recoil safety device must be in place at all times when the cylinder is not connected to the discharge piping and re- strained. NOAEL (No Observed Adverse Effect Level) - The highest concentration at which no adverse toxicological or physiologi- cal effect has been observed. 2 LOAEL (Lowest Observable Adverse Effect Level) - The lowest concentration at which an adverse physiological or toxi- cological effect has been observed. DS1258 Revised: 21-Dec-2023 Page 9 of 10 229491 Cylinder Assembly, FK-5-1-12, Sv 500 Series, 40 lb 36 (16.3) (22 to 43 lb / 10.0 to 19.5 kg capacity) 229501 Cylinder Assembly, FK-5-1-12, Sv 500 Series, 80 lb 65 (29.5) (41 to 81 lb / 18.6 to 36.7 kg capacity) 229511 Cylinder Assembly, FK-5-1-12, Sv 500 Series, 130 lb 77 (35.0) (66 to 131 lb / 29.9 to 59.4 kg capacity) FK-5-1-12 FK-5-1-12Agent Variable 18595 Bracket Assembly, Cylinder, 10" (40 lb / 80 lb / 130 lb) 10.0 (4.5) 20722 Electric Valve Actuator w/ Supervisory Limit Switch (primary cylinder) 2.0 (0.9) 17001 Manual Valve Actuator (primary cylinder) 0.6 (0.3) 17019 Pneumatic Valve Actuator (secondary cylinder) 1.2 (0.5) 18560 Valve, Check, 1/4" JIC Male x 1/4" MNPT PilotActuation Check Valve 0.3 (0.1) 18624 Bushing, 3/8" MNPT x 1/4" FNPT, Brass Pilot Actuation Adapter 0.2 (0.1) 18622 Tee, 1/4" JIC Male x 1/4" MNPT, Brass PilotActuation Mid Line Tee 0.2 (0.1) 10173 Vent Check (connects to Pilot Actuation End Line Tee) 0.2 (0.1) 18625 Adapter, 1/4" MNPT x 1/4" JIC Male, Brass 0.2 (0.1) Male NPTAdapter (connects to Pilot Actuation End Line Tee) 18611 Tee, 1/4" FNPT x 1/4" MNPT, Brass PilotActuation End Line Tee 0.3 (0.1) 97428 Switch, Discharge Pressure 1.6 (0.7) 18547 Valve, Check, FNPT, 1-1/4" (32 mm) Manifold Check Valve 6.0 (2.7) 18648 Hose, Flex, 3/16", 1/4" JIC Female, 16" long 0.6 (0.3) (recommended for 40 / 80 / 130 lb cylinder arrangements) 18777 Adapter, 1/4" JIC Male x 1/4" JIC Male, Brass Flex Hose Adapter 0.2 (0.1) Variable Nozzle, 3/8", JSH 0.5 (0.2) Variable Nozzle, 1/2", JSH 0.6 (0.3) Variable Nozzle, 3/4", JSH 0.8 (0.4) Variable Nozzle, 1", JSH 1.2 (0.5) Variable Nozzle, 1-1/4", JSH 1.6 (0.7) Variable Nozzle, 1-1/2", JSH 1.7 (0.8) Variable Nozzle, 2", JSH 3.6 (1.6) Specify the Cylinder Assembly P/N followed by a dash and the fill weight in pounds expressed in three digits Example: 22949-039 - Cylinder Assembly, FK-5-1-12, Sv 500 Series, 40 lb (39 lb fill) The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. tIJANUS IF FIRE SYSTEMS" 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1258 Revised:21-Dec-2023 Page 10 of 10 W H V) w W LOS-1 KEYED LOCK -OUT STATION LOCK -OUT Features • Flush or Surface Mount NORMAL Mounts to Standard UL Listed 2-Gang Switch Box 0 LOCKED our Key Removable in Both Positions Standard with two (2) N.C. contacts (*jANvs F1&E SYSTEMS' P/N:18849 Description SIGNALING @<FM> 9 LISTED "PFFOVED The Janus Fire Systems® LOS-1 Keyed Lock -Out Station provides a keyed method to disconnect and electrically lock -out the releasing circuit of a fire suppression system. The LOS-1 comes with a key that is removable in either the normal or locked -out position. The LOS-1 has a stainless steel faceplate with functional markings and mounts to a standard UL Listed 2-gang switch box. Operation To lock -out, insert key and turn to locked -out position. Then remove key. Dimensions 5.25 in 133 mm LOK00 O O NORMAL nnndLOCKED OUT O JANU FE SYST—V 5.31 in 135 mm Schematic KEYED LOCK -OUT DS1068 Revised: 08-Oct-2015 © 2008 Janus Fire Systems. All rights reserved (12/2008) Janus Fire Systems® is a registered trademark of Janus Fire Systems. Temperature Humidity: Weight: Dimensions: Color: Contacts Rating: Terminal Connections Ordering Information 320 to 1200 F (00 to 490 C) 90% Relative Humidity at 100' F 1.2 Ibs (0.54 kg) 5.25inHx5.31 inWx3.46inD (133 mm x 135 mm x 88 mm) Face Plate — Stainless Steel with black lettering 4 amps at 30 VAC, 0.5 amps at 30 VDC 2 x 16 AWG, 1 x 14 AWG LOS-1 18849 Keyed Lock -Out Station 1.2 (0.5) N/A 99997 N.C. Contact Block - Red 0.1 (0.05) N/A 99998 N.O. Contact Block - Green 0.1 (0.05) N/A 99996 Replacement Key 0.1 (0.05) Note: UL file number S24729 The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. % NUS FIRE SYSTEMS® 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1068 Revised: 08-Oct-2015 Page 2 of 2 ARS-1 ABORT/RELEASING STATION CLEAN AGENT TO ABORT PUSH AND TO DISCHARGE LI FT HOLD COVER AND PUSH TOGGLE UP 01*JANUS FIRE $YSi F.i S' P/N:18850 Features • Flush or Surface Mount • Dual Action Manual Release • Deadman Style Abort • Mounts to Standard UL Listed 2-Gang Switch Box • Abort — SPST Contact • Manual Release — DPST Contact SA6XAlIXG U� FM LISTED APPRUVED Description The Janus Fire Systems® ARS-1 Abort/Releasing Station combines the function of a manual release station and an abort station into a single unit. The manual release is achieved with a momentary toggle switch that is protected by a red toggle guard. A lead wire seal is provided for additional security to prevent accidental operation. The abort is achieved with a yellow deadman style mushroom head pushbutton. The ARS-1 has a stainless steel faceplate with functional markings and mounts to a standard UL Listed 2-gang switch box. Operation The ARS-1 abort function is initiated by pressing and holding the yellow pushbutton. The ARS-1 release function is initiated by breaking the lead wire seal, lifting the red toggle guard, and pushing the toggle switch up. Dimensions 5.25 in 133 mm Schematics CLEAN AGENT o o O O TO ABORT PUSH AHO TO DOSCHARGIE LR7 ®LD TOGGLE P ABORT PUSHBUTTON pO�LL 49P 0 0-- -- 0 O O 0 (W�OOCJJ S� F'R` SYsr` s` MANUAL RELEASE 5.31 in I TOGGLE SWITCH 135 mm DS1069 Revised: 08-Oct-2015 © 2008 Janus Fire Systems. All rights reserved (12/2008) Janus Fire Systems® is a registered trademark of Janus Fire Systems. Temperature: 32' to 120°F (0' to 49°C) Humidity: 90% Relative Humidity at 100°F Weight: 1.2 Ibs (0.5 kg) Dimensions: 5.25 in H x 5.31 in W x 2.95 in D (133 mm x 135 mm x 75 mm) Face Plate — Stainless Steel with black lettering Color: Mushroom Head Pushbutton —Yellow Toggle Guard — Red Manual Release Toggle (DPST): 4 amps at 30 VAC Contacts Rating: 0.5 amps at 30 VDC Abort Pushbutton (SPST): 4 amps at 30 VAC 0.5 amps at 30 VDC Terminal Connections: Manual Release Toggle: Ring Terminal, 14- 18 AWG, #6 Abort Pushbutton: 2 x 16 AWG, 1 x 14 AWG Ordering Information ARS-1 18850 Abort/Releasing Station N/A 99997 N.C. Contact Block - Red N/A 99998 N.O. Contact Block - Green 121-SK 99492 Seal, Lead, Wire (Spare) Note: UL file number S24729 1.2 (0.5) 0.1 (0.05) 0.1 (0.05) 0.1 (0.05) The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. ,%JANUS FIRE SYSTEMS® 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1069 Revised: 08-Oct-2015 Page 2 of 2 BT-80 12 VOLT, 8 AH BATTERY y- M CE P/N:18641 Standard Features • Nominal Voltage: 12 Volts • Rated Capacity: 8 AH (20 hour rate) • Length: 5.94" (151 mm) • Width: 2.56" (65 mm) • Height: 3.70" (94 mm) • Total Height: 3.98" (101 mm) • Terminals: F1-Faston Tab No. 187 Overview The BT-80 sealed lead acid battery is rated at 12 Volts, 8 AH, making it of appropriate size, Amp hour rating, and proper terminal connections for use as a battery backup for Fire Alarm Systems and as an uninterruptible power supply. Dimensions in (mm) M 5.94 (151) F1 0.13 (3.2) re - _o rn � CD ri r` ri 0.19 (4.75) 0.25 (6.35) 0.03 (0.8) 2.56 (65) DS1073 Revised: 14-Apr-2021 © 2008 Janus Fire Systems. All rights reserved (12/2008) Janus Fire Systems® is a registered trademark of Janus Fire Systems. 13 Z 12 con 11 10 9 m a 0 1 2 3 5 10 20 30 60 2 3 5 10 20 MIN= �a HOURS Discharge Time Capacity 77°F(25°C) Internal Resistance, Fully Charged Battery (77°F) Capacity affected by Temperature (20 hour rate) Charge Constant Voltage Ordering Information BT-80 18641 12 Volt, 8 AH Battery 100 A 80 ix O 60 a 40 V 5'c (41'F) Charging bafam uw 4; Nwenunended. 20'c CharorkgbW,aN,a i.,.Mr dto�vvar lutl cepad[y. (68uF) Pmimged stwage ism �m eedsd and can kin teas el ulr upaelly WC (104°F) 30°C (86°F) U 0 2 4 6 8 10 12 Storage Period (Months) 20 hour rate (0.4 A) 8 AH 10 hour rate (0.74 A) 7.4 AH 5 hour rate (1.38 A) 6.9 AH 1 hour rate (4.62 A) 4.62 AH 10 MQ 104°F (40°C) 102% 77°F (25°C) 100% 32°F (0°C) 85% 5°F (-15°C) 65% Cycle: Initial Charging Current Max 2.25 A Voltage 14.4 V - 14.8 V at 77°F (25°C) Standby: Voltage 13.5 V - 13.8 V at 77°F (25°C) 6.2 (2.8) Note: Approvals/Listings maintained by and manufactured by Elk Products, Inc. Refer to www.janusfiresystems.com for MSDS. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. tt,ANUS FIRE SYSTEMS® 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1073 Revised: 14-Apr-2021 Page 2 of 2 S-24WR SELECTABLE CANDELA STROBE U� LISTED S3247 P/N:98393 Features • 24VDC units have field selectable candela options of 15, 30, 60, 75, & 110 • Super -Slide® Bracket - Ease of Supervision Testing • Checkmate® - Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input terminals accept 12 to 18 AWG • Tamperproof re-entrant style grill • Surface mount with the AVBB (Surface Mount Back Box) or mounts to standard single gang or double gang box or double workbox • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) Dimensions • 5" (12.7 cm) height x 4.5" (11.43 cm) wide x 2.5' (6.35 cm) deep Operating temperature • 32°F to 120°F (0°C to 49°C). The S-24WR is not listed for outdoor use. Use models S-24WR-WP (P/N 98395) or SLP-24WR-WP (P/N 98396) for outdoor use (Refer to DS1282 for more information.) The S-24WR is a low profile strobe that offers dependable visual alarms and the absolute lowest current available. The S-24WR 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The S-24WR has a minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. This Series is shipped with a standard 4" metal mounting plate which incorporates the popular Super -Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The S-24WR also features the patented Checkmate® - Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The S-24WR appliance isANSI/UL 464 and ANSI/UL 1971, listed for use with fire protective systems DS1280 Revised: 28-Jan-2014 © 2014 Janus Fire Systems. All rights reserved (1/2014) Janus Fire Systems® is a registered trademark of Janus Fire Systems. Super -Slide® Mounting Bracket Allows the installer to pre -wire the system, test for system supervision, remove the signal head until occupancy, switch out signals without changing mounting brackets and has locking edge connector for snap -in place installation. IC Candela selection slider switch. Depress center and slide switch to desire brightness level. Break off pin and inser into hole at the botton of the selector to loci candela setting. Signa must be removed fron bracket and pin pushes forward from backsid( out of hole to chang( candela. Checkmate® Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTE: Care should be taken to not short the test probes. To remove bezel, grip both sides of bezel and pull in a downward and outward motion. 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA 110 cd 103 mA 161 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) pow- er, see installation manual. • Janus Fire Systems does not recommend using a coded or pulsing signaling circuit with any of our strobe products. DS1280 Revised: 28-Jan-2014 Page 2 of 4 Engineering Specifications The visible signal shall be S-24WR or approved equal and shall be listed by Underwriters Laboratories, Inc. per ANSI/UL 1971 and/or ANSI/UL 464. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed Carol s goal sWal Panel s• s+ s H. H- s+ Supervised B m 0 9 Signal Circuit E HD OF i1NE FlESSiTOR NOTES: Controle sg�a Panel S. Supervised IFD N PIP PI Signal CIrcult + a EHD�F u�nE n T � ERE95ioa • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the AVSM-R control module (P/N 98377) or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM-R CONTROL MODULE DATA SHEET (DS1284) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. DS1280 Revised: 28-Jan-2014 Page 3 of 4 Ordering Information S-24WR Selectable Candela Strobe (red) AVBB-R Surface Mount Backbox, Indoor (red) HSNG-AGENT-R Bezel "AGENT" (red) HSNG-ALERT-R Bezel "ALERT" (red) Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. 98393 98378 98376 98375 The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. ,%JANUS FIRE SYSTEMS® 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1280 Revised: 28-Jan-2014 Page 4 of 4 HS-24WR HORN/STROBE U� LISTED S3247 P/N:98394 Features • 24VDC units have field selectable candela options of 15, 30, 60, 75, & 110 • Super -Slide® Bracket - Ease of Supervision Testing • Checkmate® - Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input terminals accept 12 to 18 AWG • Switch selection for high or low dBA • Switch for chime, whoop, mechanical and 2400Hz tone • Tamperproof re-entrant style grill • Switch for continuous or temporal 3 tone (not available on whoop tone) • Surface mount with the AVBB (Surface Mount Back Box) or mount to a standard single gang or double gang box or double workbox • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) Dimensions • 5" (12.7 cm) height x 4.5" (11.43 cm) wide x 2.5' (6.35 cm) deep Operating temperature • 32°F to 120°F (0°C to 49°C). The HS-24WR is not listed for outdoor use. Use models HS-24WR-WP (P/N 98397) or HSLP-24WR-WP (P/N 98398) for outdoor use (Refer to DS1282 for more information.) The HS-24WR is a low profile horn/strobe combination that offers dependable audible and visual alarms and the absolute lowest current available. The HS-24WR 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The Horn/Strobe offers a continuous or sync temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to change in the field by the use of switches. The HS-24WR has a minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. This Series is shipped with a standard 4" metal mounting plate which incorporates the popular Super -Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The HS-24WR also features the patented Checkmate® - Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The HS-24WR Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use with fire protective systems. DS1281 Revised: 28-Jan-2014 © 2014 Janus Fire Systems. All rights reserved (1/2014) Janus Fire Systems® is a registered trademark of Janus Fire Systems. Mechanical Temporal 3 ON ON ON —®OZ Mechanical - Continuous OFF ON ON cf M® 2400Hz - Temporal 3 ON OFF ON 24001-11z - Continuous OFF OFF ON Chime - Temporal 3 ON ON OFF Ef �® Chime - Continuous OFF ON OFF to Whoop ON OFF OFF Whoop OFF OFF OFF Efa'® NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs. • Switch Position 6 ON = HIGH dBA • Switch Position 6 OFF = LOW dBA Zo Super-Slide® Mounting Bracket (2= Z Allows the installer to pre -wire ` the system, test for system ll supervision, remove the signal head until occupancy, switch out signals without changing mounting brackets and has locking edge connector for snap -in place installation. Candela selection slider switch. Depress center and slide switch to desire brightness level. Break off pin and inser into hole at the botton of the selector to loci candela setting. Signa must be removed fron bracket and pin pushes forward from backsid( out of hole to chang( candela. Checkmate® Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTE: Care should be taken to not short the test probes. To remove bezel, grip both sides of bezel and pull in a downward and outward motion. DS1281 Revised: 28-Jan-2014 Page 2 of 4 15 cd 30 mA 42 mA 62-82 100 30 cd 35 mA 58 mA 62-82 100 60 cd 66 mA 97 mA 62-82 100 75 cd 80 mA 116 mA 62-82 100 110 cd 103 mA 161 mA 62-82 100 Temp 3 24001-lz 78 dBA 71* dBA 28 mA Temp 3 Mechanical 76 dBA 70* dBA 25 mA Temp 3 Chime 70* dBA 66* dBA 15 mA Continuous 24001-lz 81 dBA 74* dBA 28 mA Continuous Mechanical 80 dBA 72* dBA 25 mA Continuous Chime 70* dBA 66* dBA 15 mA Whoop 82 dBA 69* dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. • Janus Fire Systems does not recommend using a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/ UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Engineering Specifications The audible and/or visible signal shall be HS-24RW horn/strobe or approved equal and shall be listed by Underwriters Laboratories, Inc. perANSI/UL 1971 and/or ANSI/UL 464. The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. DS1281 Revised: 28-Jan-2014 Page 3 of 4 Conventional Wiring Diagrams for Emergency Notification Evacuation Series LIL Listed LIL Listed Control Control Panel °�'� Panel s� s+ s+ s- n. ri- s, s+ s• n+ H• s- H+ H- s+ H+ 1+ Supervised IP q Pip PI Supervised B G B B Signal Circuit Signal Circuit + , a ExoaruNE EH�OF TINE NESP3TOR ��� PE45 NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the AVSM-R control module (P/N 98377) or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM-R CONTROL MODULE DATA SHEET (DS1284) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. Ordering Information SH-24WR Horn/Strobe (red) 98394 AVBB-R Surface Mount Backbox, Indoor (red) 98378 HSNG-AGENT-R Bezel "AGENT" (red) 98376 HSNG-ALERT-R Bezel "ALERT" (red) 98375 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. ,%JANUS FIRE SYSTEMS® 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1281 Revised: 28-Jan-2014 Page 4 of 4 JFS-IP60 ADDRESSABLE FIRE CONTROL PANEL Illy LISTED P/N 97681 Description Features • 60 addresses available on this analog addressable system • Additional system capacity achieved via multi -point SLC modules • 99 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built -In • System Operates as Class A or Class B for SLC, P-Link and NACs • 5 Amp Power Supply, Expandable to 310 amps • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort • Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer • Cabinet will house up to 18 AH batteries • Optional two line DACT with UD-1000 that can report General, Zone or Point Information • Built in IP Communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status, Reports and Event Information The JFS-IP60 is an analog/addressable releasing fire alarm system with a total system capacity of 60 addresses. Additional capacity on the system is achieved using multi -point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electri- cal Code (NEC). The JFS-IP60 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (1/0) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Coo- per/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The JFS-IP60 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the JFS-PS1000 may be used to extend releasing capability. The NACs may be expanded using the JFS-PS1000 series intelligent power supplies. Each JFS- PS1000 adds another 10 Amps of power, 2 additional input circuits and the JFS-IP60 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the JFS- PS1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. DS1317 Revised: 23-Jul-2020 © 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire Systems. 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ • 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA • 5 Amps power for NACs, 1/0, and P-Link • 3 Amps per NAC, regulated • 1 Amp per 1/0 circuit, regulated • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp 32' to 120° (0°C to 49°C) with a maximum humidity of 93% non -condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Station (IRS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Automatic (A), Manual (M), Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pol), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The sys- tem does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. SLC Loop Accessories The control panel may be connected with up to 60 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. Combination Analog Photo Electric Smoke/Heat Detector — a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135' Fahrenheit heat detector. Analog Fixed Temperature Heat Detector that is selectable from 135°F to 185°F. Addressable Duct Smoke Detector with Form C Relay. Addressable Duct Smoke Detector. 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. Addressable Sounder Base that contains an addressable sounder module that may be con- figured for local, group and all call. Addressable CO gas detector. Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. DS1317 Revised: 23-Jul-2020 Page 2 of 6 User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: • AC Power - Green • Alarm - Red • Earth Fault -Amber • Supervisory -Amber • Silenced -Amber • Trouble - Amber • Pre -Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. Ethernet/I.P. Connection The JFS-IP60 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur -Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. P-Link The JFS-IP60 has a proprietary communication protocol that communicates through a RS-485 con- nection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version avail- able. 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. 10 amp, remote intelligent power supply with 6 NACs, 2 I/Os and a P-Link repeater. This panel is listed in conjunction with the JFS-IP60 as releasing circuits. Class A convertor that converts the SLC, NACs and P-Link connection UL listed, Dual line telephone alarm communicator LED driver expander, used to connect up to 50 LEDs in a graphic display Fire communication bridge, provides remote mounting of the Ethernet connection Fiber interface module, used to extend P-Link to multimode fiber (2 required) Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC Serial parallel gateway, allows for the connection to a serial or parallel printer Multi -Connect allows up to sixty-three IP series panels to share a single reporting technology. Two card expansion cabinet Eight card expansion cabinet Fourteen card expansion cabinet DS1317 Revised: 23-Jul-2020 Page 3 of 6 Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. Micro Input Module provides a small foot print contact module for mounting inside an enclo- sure. Single Action Addressable Pull Station. Dual Action Addressable Pull Station. Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. Zone Module is used to connect conventional 2-wire smoke detectors to the system. Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Module provides a single addressable LED that is controlled by the control panel. Speaker Module provides switching for two audio channels. Addressable LED and key switch that mounts in a single gang box. DUCTR Remote Test Switch that mounts in a single gang box. One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Dimensions roR - . : 0 T.EPTH = 3.75 " 0 0 DOOR= 16.07" g4ClBOX= 15.77" DEPTH = 3.84" s❑ LEFT SIDE BOTTOM 0 C) RIGHT SIDE DS1317 Revised: 23-Jul-2020 Page 4 of 6 JFS-IP60 Addressable Releasing Control Panel 97681 BT-80 Battery, 12V 8AH (2 Req'd) 18641 BT-1201 Battery, 12V 12AH (2 Req'd) 18642' BT-180 Battery, 12V 18AH (2 Req'd) 18643 BT-260 Battery, 12V 26AH (2 Req'd) 18644 EOLD 30050122 EOL Resistor/Diode Assembly for Releasing Circuit 187122 ' JFS-IP Series cabinets will not hold 12 AH batteries. Janus recommends using 18 AH batteries when 12 AH are required. 2 For releasing use, EOLD 3005012 must be ordered separately. n/a Spare CPU, JFS-IP60 97604 n/a EOL Resistor, 5.1 K 99950 PAD100-SLCE Analog/Addressable Loop Expansion Module 97652 JFS-ANN1 LCD Remote Annunciator 99247 JFS-ANN2 LCD Remote Annunciator 98725 LED-16 16 LED Annunciator 97644 LED-16F 16 LED Annuciator (Flush model) 97645 JFS-PS1000 Remote Intelligent Power Supply 98802 JFS-PS1000E Remote Intelligent Power Supply (room for 6 Expansion Cards) 98728 CA-6075 Class A Expander Module 99246 UD-1000 Digital Alarm Communicator Transmitter 98729 DRV-50 LED Driver Module 98529 FCB-1000 Fire Communication Bridge 98528 FIB-1000 Fiber Interface Bridge 98527 RLY-5 Relay Expander Module 98526 SPG-1000 Serial Parallel Gateway 98525 MC-1000 Multi -Connect 97651 AE-2 Two Card Expansion Cabinet 97647 AE-8 Eight Card Expansion Cabinet 98622 AE-14 Fourteen Card Expansion Cabinet 98621 DS1317 Revised: 23-Jul-2020 Page 5 of 6 PAD100-MIM Miniature Input Module 97666 PAD100-PSSA Single Action Addressable Pull Station 97654 PAD100-PSDA Dual Action Addressable Pull Station 97655 PAD100-SIM Single Input Module 97662 PAD100-DIM Dual Input Module 97663 PAD100-TRTI Two Relay Two Input Module 97665 PAD100-NAC Notification Appliance Circuit 97659 PAD100-ZM Zone Module 97660 PAD100-IM Isolater Module 97658 PAD100-RM Relay Module 97661 PAD100-LED LED Module 97656 PAD100-SM Speaker Module 97653 PAD100-LEDK LED and Key Switch 97657 PAD100-DRTS DUCTR Remote Test Switch 97678 PAD100-OROI One Relay One Input Module 97664 SLC ... Devices PAD100-PD Analog Photoelectric Smoke Detector 97670 PAD100-PHD Combination Analog Photoelectric Smoke/Heat Detector 97669 PAD100-HD Analog Fixed Temperature Heat Detector 97668 PAD100-DUCTR Addressable Duct Smoke Detector with Form C Relay 97677 PAD100-DUCT Addressable Duct Smoke Detector 97676 PAD100-6DB 6" Analog Smoke Detector Base 97671 PAD100-4DB 4" Analog Smoke Detector Base 97672 PAD100-IB Addressable Isolator Base 97673 PAD100-RB Addressable Relay Base 97675 PAD100-SB Addressable Sounder Base 97674 PAD100-CD Addressable CO Gas Detector 97667 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. tIJANUS IF FIRE SYSTEMS" 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1317 Revised: 23-Jul-2020 Page 6 of 6 PAD1OO-SIM SINGLE INPUT MODULE Features • One (1) Class B monitoring input • SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • NOTE: This addressable module does not support 2-wire smoke detectors. Specifications Operating Voltage: 24.OV + Max SLC Standby Current: 240pA Max SLC Alarm Current: 240pA Max Wiring Resistance of IDC: 100 0 Max Wiring Capacitance of IDC: 1 pF @ EOL Resistor: 5.1 K 0 LISTED Operating Temperature Range: 32 to 120°F (0 to 49°C) Operating Humidity Range: 0 to 93% (non -condensing) P/N 97662 Max no. of Module Per Loop: 127 units Dimensions: 4.17" x 4.17" x 1.14" (106 mm x 106 mm 29 mm) Mounting Options: Standard 4" Square or Double Gang Box Shipping Weight: 0.6 Ibs Description The PAD100-SIM uses one (1) SLC loop addresses when monitoring one (1) Class B circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring one (1) Class B circuit. The PAD100-SIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The PAD100-SIM is compatible with JFS-IP series addressable fire alarm control panels. The PAD100-SIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, valve tamper switches, or conventional pull stations. The module is capable of monitoring one Class B circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 1OO-SIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential dam- age to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. DS1330 Revised: 15-Dec-2017 © 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire Systems. Installation Wiring PAD100-SIM With Class 8 Circuit FROM FACP OR PREVIOUS MODULE TO NEXT MODULE END -OF -LINE RESISTOR 5.11KOHM % W PAD100-SIM Single Input Module Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. 97662 The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. *JANUS 00, FIRE S L J L F M Sw 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.j a n u s f i re s yste m s. co m DS1330 Revised: 15-Dec-2017 Page 2 of 2 PAD100-RM RELAY MODULE Features • One (1) Form C relay contact • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box goo All wiring terminals accept 22 to 12 AWG =� .j f,f Specifications ill Operating Voltage: 24.OV Max SLC Standby Current: 240pA 1 J ` Max SLC Alarm Current: 240pA Relay Contacts: 2A @30VDC, 0.5A @125VAC Operating Temperature Range: 32 to 120°F (0 to 49°C) Operating Humidity Range: 0 to 93% (non -condensing) @ Max no. of Module Per Loop: 127 units Dimensions: 4.17" x 4.17" x 1.14" 106 29 (106 mm x mm mm) LISTED Mounting Options: Standard 4" Square or Double Gang Box P/N 97661 Shipping Weight: 0.6 Ibs Description The PAD100-RM uses one (1) SLC loop address to provide one (1) Form C relay contact. The module mounts on either a 4" square or double gang box. The PAD100-RM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PAD100-RM is compatible with JFS-IP series addressable fire alarm control panels. The PAD100- RM is an interface module providing one (1) Form C relay contact. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD100-RM. The PAD100-RM uses a single device address to identify relay contacts. Before connecting a device to the SLC loop, take the following precautions to prevent potential dam- age to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. DS1331 Revised: 15-Dec-2017 © 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire Systems. Installation Wiring PAD100-RM Relay Circuit FROM FACP OR PREVIOUS MODULE TO NEXT MODULE NOTE: It is possible that the internal relay in the PAD100-RM may be shipped in the non -normal / activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. 1) FORM C CONTACTS PAD100-RM Relay Module 97661 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. *-JANUS FIRE SYSTEMS* 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1331 Revised: 15-Dec-2017 Page 2 of 2 PAD100-NAC NOTIFICATION APPLIANCE CIRCUIT Features Monitored output module that provides an additional supervised output Can be used as either a NAC or Releasing Output • NAC can be wired Class A or Class B • Monitors presence of 24 VDC Aux Power • SLC Class A, Class X, & Class B - Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG Specifications Operating Voltage: 24.OV Max SLC Standby Current: 200pA Max SLC Alarm Current: 200pA @ Aux Power Required: 16-33 VDC LISTED Output Ratings: 24 VDC, 2A EOL Resistor: 5.1 K 0 P/N 97659 EOL Resistor Diode: EOLR 3005012 (P/N 18712) for Releasing Applications (Must Be Ordered Separately) Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range: 0 to 93% (non -condensing) Max no. of Module Per Loop: 127 units Dimensions: 4.17" x 4.17" x 1.14" (106 mm x 106 mm 29 mm) Mounting Options: Standard 4" Square or Double Gang Box Description Shipping Weight: 0.6 Ibs The PAD 100-NAC module uses one (1) address on an SLC Loop. The module provides a program- mable source of power to supervise and control one (1) Class B or Class A Notification Appliance or one (1) Class B Releasing Circuit. The module requires and supervises a 24 VDC auxiliary power connection. The PAD100-NAC includes one red LED to indicate the module's status. In normal condi- tion, the LED flashes when the device is being polled by the control panel. Application The PAD100-NAC is compatible with JFS-IP series addressable fire alarm control panels. The PAD100-NAC is a monitored Notification Appliance Circuit that wires to the SLC loop to provide an additional notification circuit. When used with an addressable releasing panel, the PAD100-NAC can provide an additional releasing circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch- es on the PAD100-NAC module. Before connecting a device to the SLC loop, take the following precautions to prevent potential dam- age to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. DS1333 Revised: 23-Jul-2020 © 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire Systems. Installation NOTE: It is possible that the internal relay in the PAD100-NAC may be �4& 0 0 shipped in the non -normal / activated state. To ensure that the internal relay 0 0 is set to the normal state, connect the ° 0 module to the SLC loop and reset the ® e control panel before terminating the wiring to the modules output. Wiring Output Connected to a Notification Appliance Circuit Typical Class 8 Wiring Diagram PAD10U-NAC CLASS B END OF LINE RESISTOR 5.1KOHM Y W NOT SUITABLE FOR SYNCHRONIZATION OF NOTIFICATION APPLIANCES Typical Class A Wiring Diagram o 0 O a PREVIOUS MODULE ® - PADI ORNAC CLA55 A } } } NOTE: END -OF -LINE 70NEX7MODU r _ RESISTOR NOT DRPRE�ID =MDD LE LL ZQ ® NOTSUCABLEFDR OR NE%T MODULE NOTFNCANON A'11L1.1EI CD O Releasing Application C /� \� \� PAD1U°-NACReIe ,I,g Solenoid FROM FACE OR PREVIOUS MODULE O NOTE: END -OF -LINE DIODE ASSEMBLYREQUIRED ® ® RED BLACK TONEXTMODULE ® . K AUXILIARY 24 VOLTPOWER ® LE ® SOLENOID ROM FACP ( O NOTE: EOLDEVICE SHALL BE INSTALLED IN THE SAMEELCTRICAL ENCLOSURE ASTHE RELEASING DEVICE, PAD100-NAC Notification Appliance Circuit EOLD 3005012 EOL Resistor/Diode Assembly for Releasing Circuit Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. 97659 18712 The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. tIJANUS IF FIRE SYSTEMS" 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.janusfiresystems.com DS1333 Revised: 23-Jul-2020 Page 2 of 2 PAD100-DIM DUAL INPUT MODULE Features • Single module with dual contact monitoring inputs • Two (2) Class B or one (1) Class A monitoring inputs SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG NOTE: This addressable module does not support 2-wire smoke detectors. Specifications 0 Operating Voltage: 24.OV Max SLC Standby Current: 240pA Max SLC Alarm Current: 240pA Max Wiring Resistance of IDC: 100 0 uO�� Max Wiring Capacitance of IDC: 1 pF EOL Resistor: 5.1 K 0 Operating Temperature Range: 32 to 120OF (0 to 49°C) P/N 97663 Operating Humidity Range: 0 to 93% (non -condensing) Max no. of Module Per Loop: 127 units Dimensions: 4.17" x 4.17" x 1.14" (106 mm x 106 mm 29 mm) Mounting Options: Standard 4" Square or Double Gang Box Description Shipping Weight: 0.6 Ibs The PAD100-DIM uses one (1) SLC loop address when monitoring two (2) Class B circuits or one (1) Class A circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring two (2) separate class B circuits making it ideal for monitoring sprinkler waterflow and valve tamper switches when they are located in the same proximity. The PAD100-DIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is be- ing polled by the control panel. When an input is activated, the LED will flash at a fast rate. Application The PAD100-DIM is compatible with JFS-IP series addressable fire alarm control panels. The PAD100-DIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, valve tamper switches, or conventional pull stations. The module is capable of monitoring two sepa- rate Class B or one Class A circuits. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD100-DIM. When the PAD100- DIM is used to monitor two individual Class B cir- cuits a single device address is assigned, each input is then identified as a sub -point of the module address. For example, if the address number is assigned as "8", the first input will be "8.1" and the second input will be "8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential dam- age to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. DS1336 Revised: 30-Aug-2018 © 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire Systems. Installation Wiring PAD100-DIM With Two Class B Circuits MOVETHE"CL-A"DIP SWITCH TO"DOWN" POSITION c> FOR CLASS B WIRING FROM FACP OR OR �� p PREVIOUS 0 TO NEXTMODULE ® Nf END -OF -LINE ® J RESISTOR S.IK OHM y-,W ® en ®woi�maw� a ® G END -OF -LINE SISTOR 5E KOHM %W r r 1 PAD 100-DIM With One Class A Circuit MOVE THE"CL-A"DIP SWITCH TO"UP"POSITION FORCLASSAWIRING FROM FACP OR 0- PREVIOUS MODULE TO NEXT MODULE ® J®Pol'113g G:D ® G NOTE: END -OF -LINE RESISTOR IS NOT REQUIRED PAD100-DIM Dual Input Module 97663 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. AN U S -- FIRESYSTEMS"" 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.j a n u s f i re s yste m s. co m DS1336 Revised: 30-Aug-2018 Page 2 of 2 U D-2000 DIGITAL ALARM COMMUNICATOR Features • Allows for communication to Monitoring Station • Communicates using SIA-DCS or Ademco Contact ID Protocols • For use with JFS-IP series Addressable Panels • Status LEDs indicate operation of DACT card • Installs with ease behind main panel LCD display via User Interface bracket • Device address is set internally to address 1 • Includes two (2) RJ45 phone cords OL ra LISTED P/N 97170 Description The UD-2000 Digital Alarm Communicator Transmitter (DACT) provides for up to two (2) phone lines for communication to a monitoring station. The UD-2000 communicates using the SIADCS orAdem- co Contact ID protocols. When enabled, the DACT automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the communication is complete, the DACT will hang up. The DACT is provided with terminal blocks for each phone line and two RJ45 cords. In order for the DACT to work properly, it must be installed on a plain old telephone service (POTS) line or equivalent deemed by the authority having jurisdiction. The DACT must be installed before any other equipment to ensure it can seize the phone line. Phone lines are high voltage and should be run in a separate conduit from other circuits. The wire conductors connecting the DACT to the phone system should be 26 AWG or larger. Operating Voltage 22.0-24.OV Standby Current 16mA Alarm Current 23mA Max UD-2000s per panel 1 Dimensions 4 in W x 6 in H x 1-5/8 in D (102 mm x 152 mm x 41 mm) Operating Temperatures 32°F- 120°F (0°C - 49°C) Operating Humidity Range 10% - 93% @ 860F (30°C) (non -condensing) Mounting Options In FACP Behind keypad Shipping Weight 0.47 Ibs (0.21 kg) DS1363 Revised:09-Aug-2019 © 2019 Janus Fire Systems. All rights reserved (8/2019) Janus Fire Systems® is a registered trademark of Janus Fire Systems. RJ31X Phone Jack to UD-2000 Plain Old Telephone (POTS) lines Tip (Brown) Out to Premises Phones 1 - Grey llL 2 -Tan 3 - Black 2 4-Red - Green 6 6 - Yellow ; 7 - Blue ® 8 -Brown Line In From Telco Tip (Green) 2 Tel,'o4 \1?hone 1 ag Ti�lff Rr g Teal UD-2000 Communicator Telco Tip = Red Telco Ring = Green Phone Tip = Brown Phone Ring = Grey Installation Ring (Grey) Out to Premises Phones Ring (Red) Line In From Telco The UD-2000 DACT is connected to the control panel using the provided four -wire cable connection between P4 and UD-2000 P1. The connection is power limited and supervised. 1. Power system down. 2. Slide the UD-2000 DACT into the card guides located under the panel User Interface bracket. 3. Secure the UD-2000 DACT to the User Interface bracket using the provided #6-32 x 3/8" 4. Install the provided four -wire conductor jumper between UD-2000 P1 and P4. NOTE: Install in accordance with compatible fire alarm control panel installation manual UD-2000 DACT Installation on JFS-IP60 and JFS-IP127 Panels ° a ° ° p m o � Q ° o o o R R Screw i� It�T R U I IrP on small platform control panel DS1363 Revised:09-Aug-2019 Page 2 of 4 UD-2000 Digital Alarm Communicator 97170 Note: Approvals/Listings maintained by and manufactured by Potter Electric Signal Company. The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, except as expressly stated in the seller's sales contract or sales acknowledgment form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can all requirements be anticipated. All specifications are subject to change without notice. OJANUS Ar FIRSYSTEMS" 1102 Rupcich Drive Millennium Park Crown Point, IN 46307 TEL: (219) 663-1600 FAX: (219) 663-4562 e-mail: info@janusfiresystems.com www.j a n u s fi re s yste m s. co m DS1363 Revised:09-Aug-2019 Page 4 of 4 FM Approved Firestop Contractor FM Standard 4991 6314 W. STONER DRIVE SUITE D GREENFIELD, IN 46140 �saPtvi4j�+w� G� OFFICE: (317) 894-9111 �+ FAX: (317) 894-4333 EMAIL: ppmifirestop@ppmifirestop.com�'�hopalAss'�oc www.ppmifirestop.com February loth, 2025 078400 FIRESTOP SUBMITTAL PACKAGE PROJECT: South Bend WWTP Server Room THIS SUBMITTAL CONTAINS: • PPMI Firestop Certification ■ Hilti - Products Certification ■ Hilti - Product Data Sheets • Roxul - Product Data Sheets ■ Shop Drawings, Test Reports & Instructions U L SYSTEM INSTANCES OF USE BW-S-0001 Bottom of Wall Fire Rated Gypsum Board Wall HW-D-0077 Top of Wall Fire Rated Gypsum Board Wall to Fluted Metal Deck HW-D-0184 Top of Wall Fire Rated Gypsum Board Wall to Fluted Metal Deck W-L-1297 Metal Pipe/Conduits Through Gypsum Board Wall W-L-1465 Metal Pipe/Conduits Through Gypsum Board Wall W-L-2128 Non -Metallic Pipe Through Gypsum Board Wall W-L-2406 Non -Metallic Pipe Through Gypsum Board Wall W-L-5027 Insulated Metal Pipe Through Gypsum Board Wall W-L-5096 Insulated Metal Pipe Through Gypsum Board Wall W-L-7042 Round Duct Through Gypsum Board Wall W-L-7153 Insulated Round Duct Through Gypsum Board Wall W-L-7155 Insulated Rectangular Duct Through Gypsum Board Wall W-L-7156 Insulated Rectangular Duct Through Gypsum Board Wall System No. BW-S-0001 c VAV us Classified by ANSI/UL2079 Underwriters Laboratories, Inc. to UL 2079 and CANIULC-S115 Assembly Ratings —1 and 2 Hr (See Item 2) Nominal Joint Width - 3/4 In. L Rating at Ambient — Less than 1 CFM/Lin Ft L Rating at 400° F — Less than 1 CFM/Lin Ft c CANIULC S115 F Ratings —1 and 2 Hr (See Item 2) FT Ratings —1 and 2 Hr (See Item 2) FH Ratings —1 and 2 Hr (See Item 2) FTH Ratings —1 and 2 Hr (See Item 2) Nominal Joint Width - 3/4 In. L Rating at Ambient — Less than 1 CFM/Lin Ft L Rating at 400* F — Less than 1 CFM/Lin Ft 1. Floor Assembly— Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) structural concrete. Floor may also be constructed of any 6 in. (152 mm) thick UL Classified hollow -core Precast Concrete Units*. See Precast Concrete Units category in the Fire Resistance Directory for names of manufactures. 2. Wall Assembly — The 1 or 2 h fire -rated gypsum board/steel stud wall assembly shall be constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall or Partition Design in the UL Fire Resistance Directory. In addition, the wall may incorporate a head -of -wall joint system constructed as specified in the HW Series Joint Systems in the UL Fire Resistance Directory. The wall shall include the following construction features: A. Steel Floor Runner — Floor runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized to accommodate steel studs (Item 213). Floor runners to be provided with min 1-114 in. (32 mm) flanges. Runners secured with steel fasteners spaced 12 in. (305 mm) OC. B. Studs — Steel studs to be min 2-1/2 in. (64 mm) wide. Studs cut 1/2 to 3/4 in. (13 to 19 mm) less in length than assembly height with bottom nesting in, resting on and fastened to floor runner with sheet metal screws. Stud spacing not to exceed 24 in. (610 mm) OC. C. Gypsum Board* — Gypsum board installed to a min total thickness of 5/8 or 1-1/4 in. (16 or 32 mm) on each side of wall for a 1 or 2 hr rated wall, respectively. Wall to be constructed as specified in the individual U400 or V400 Series Design in the UL Fire Resistance Directory, except that a max 3/4 in. (19 mm) gap shall be maintained between the bottom of gypsum board and top of concrete floor. The hourly fire rating of the joint system is equal to the hourly fire rating of the wall. 3. Fill, Void or Cavity Material* Sealant — Max separation between top of floor and bottom of gypsum board is 3/4 in. (19 mm). For 1 and 2 hr rated wall assemblies, min 5/8 in. or 1-1/4 in. (16 or 1-1/4 mm) thickness of fill material, respectively, installed on each side of the wall between the bottom of the gypsum board and the top of the concrete floor, flush with each surface of the wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601S Elastomeric Firestop Sealant, CP606 Flexible Firestop Sealant, CFS-S SIL GG, FS-ONE Sealant or FS-ONE MAX Intumescent Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of M=!Ym Underwriters Laboratories, Inc. Hilti Firestop Systems January26, 2015 Co cm 0 m G�Ss rF�� System No. HW-D-0077 Assembly Rating —1 or 2 Hr (See Items 2 and 3) Classified by Nominal Joint Width — 314 In. Underwriters Laboratories, Inc. L RatingAt Ambient — Less Than 1 CFMILin Ft toUL2079 L Rating At 400OF — Less Than 1 CFMILin Ft Class II Movement Capabilities —17% Compression or Extension PenT1e%U A A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. June 22, 2023 Hilti Firestop Systems 1 of 3 System No. HW-D-0077 1. Floor Assembly — The fire -rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner described in the individual D700 or D900 Series Floor -Ceiling Design in the Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Form Units* - Max 3 in. (76 mm) deep galv steel fluted floor units. B. Concrete — Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units. C. Spray -Applied Fire Resistive Materials — (Optional, Not Shown) — Prior to or after the installation of the ceiling runner and Fill, Void or Cavity Materials (Item 3), the steel floor units may be sprayed with a min 5/16 in. (8 mm) thickness to a max 11/16 in. (17 mm) thickness of fire resistive material. GCP APPLIED TECHNOLOGIES INC — Type MK-6/HY 1A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P900 Series Roof -Ceiling Design in the UL Fire Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall assembly. The roof assembly shall include the following construction features: A. Steel Roof Deck — Max 3 in. (76 mm) deep galv steel fluted roof deck. B. Roof Insulation — Min 2-1/4 in. (57 mm) thick poured insulating concrete, as measured from the top plane of the floor units. 1 B. Roof Assembly — As an alternate to Items 1 and 1A, a fire rated protected fluted steel deck roof assembly may be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P700 Series Roof -Ceiling Design in the UL Fire Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall assembly. The roof assembly shall include the following construction features: A. Steel Roof Deck — Max 3 in. (76 mm) deep galv steel fluted roof deck. B. Spray Applied Fire Resistive Materials* — (Not Shown) —Prior to or after the installation of the steel ceiling runners, Forming Material and Fill, Void or Cavity Material (Items 2A, 3A, 3B), the roof assembly shall be sprayed with the type and thickness of fire resistive material indicated in the individual P700 Series design. GCP APPLIED TECHNOLOGIES INC — Type MK-6/HY 2. Wall Assembly — The 1 or 2 hr fire -rated gypsum board /steel stud wall assembly shall be constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Ceiling Runners — Floor and ceiling runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized to accommodate steel studs (Item 2B).Flange height of ceiling runner shall be min 1/4 in. (6 mm) greater than max extended joint width Ceiling .runner installed perpendicular to direction of fluted steel deck and secured to valleys with steel masonry anchors, steel fasteners or welds spaced 24 in. (610mm) OC before or after optional spray -applied fire resistive material is used. The use of welds to secure the ceiling runner may only be used prior to the installation of the optional spray -applied material. Al. Light Gauge Framing* -Slotted Ceiling Runner— As an alternate to the ceiling runner in Item 2A, slotted ceiling runner to consist of galv steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Slotted ceiling runner installed perpendicular to direction of fluted steel deck and secured to valleys with steel masonry anchors, steel fasteners or welds spaced 24 in. (610mm) OC before or after optional spray -applied fire resistive material is used. The use of welds to secure the ceiling runner may only be used prior to the installation of the optional spray -applied material. BRADY CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS — SLP-TRK CEMCO, LLC — CST CLARKDIETRICH BUILDING SYSTEMS — Type SLT, SLT-H MARINO/WARE, DIV OF WARE INDUSTRIES INC—Type SLT METAL-LITE INC — The System RAM SALES L L C — RAM Slotted Track SCAFCO STEEL STUD MANUFACTURING CO TELLING INDUSTRIES L L C— True -Action Deflection Track Reproduced by HILT], Inc. Courtesy of Underwriters Laboratories, Inc. HIM Firestop Systems June 22, 2023 2of3 ti ti System No. HW-D-0077 0 3 A2. Light Gauge Framing* -Vertical Deflection Ceiling Runner — As an alternate to the ceiling runners in Items 2A and 2A1, vertical deflection ceiling runner to consist of galv steel channel with slotted vertical deflection clips mechanically fastened within runner. Slotted clips, provided with step bushings, for permanent fastening of steel studs. Flanges sized to accommodate steel studs (Item 2B). Vertical deflection ceiling runner installed perpendicular to direction of fluted steel deck and secured to valleys with steel masonry anchors, steel fasteners or welds spaced 24 in. (610mm) OC before or after optional spray -applied fire resistive material is used. The use of welds to secure the ceiling runner may only be used prior to the installation of the optional spray -applied material. THE STEEL NETWORK INC — VertiTrack VTD250, VTD362, VTD400, VTD600 and VTD800 A3. Light Gauge Framing* - Notched Ceiling Runner — As an alternate to the ceiling runners in Items 2A through 2A3, notched ceiling runners to consist of C-shaped galv steel channel with notched return flanges sized to accommodate steel studs (Item 213). Notched ceiling runner installed perpendicular to direction of fluted steel deck and secured to valleys with steel masonry anchors, steel fasteners or welds spaced 24 in. (610mm) OC before or after optional spray -applied fire resistive material is used. The use of welds to secure the ceiling runner may only be used prior to the installation of the optional spray -applied material. OLMAR SUPPLY INC — Type SCR B. Studs —Steel studs to be min 2-112 in. (64 mm) wide. Studs cut 1l2 to 314 in. (13 to 19 mm) less in length than assembly height with bottom runner without attachment. When slotted ceiling runner (Item 2A1) is used, nesting in and resting on floor runner and with top nesting in ceiling steel studs secured to slotted ceiling runner with No. 8 by 112 in. (13 mm) long wafer head steel screws at midheight of slot on each side of wall. Stud spacing not to exceed 24 in. (610 mm) OC. When vertical deflection ceiling runner (Item 2A2) is used, steel studs secured to slotted vertical deflection clips, through the bushings, with steel screws at midheight of each slot. Stud spacing not to exceed 24 in. (610 mm) OC. C. Gypsum Board* — Gypsum board installed to a min total thickness of 5/8 or 1-114 in. (16 or 32 mm) on each side of wall, for 1 or 2 hr fire resistance rated walls, respectively. Wall to be constructed as specified in the individual U400 or V400 Series Design in the UL Fire Resistance Directory, except that the gypsum board is cut to fit the contour of the steel floor units with a max 314 in. (19 mm) gap. The screws attaching the gypsum board to the studs at the top of the first layer shall be located 4 in. (102 mm) from the steel floor unit valleys. The screws attaching the second layer to the steel studs shall be installed into the studs 3-112 in. (89 mm) below the valleys of the steel floor units. The hourly fire rating of the joint system is dependent on the hourly rating of the wall. 3. Fill, Void or Cavity Material* — Sealant — Max separation between bottom of floor and top of wall is 314 in. (19 mm). The joint system is designed to accommodate a max 17 percent compression or extension from its installed width. Min 1-114 in. (32 mm) thickness of fill material flush with the surface of the gypsum board for 2 hr fire rated systems or 518 in. (16 mm) thickness of fill material for 1 hr fire rated systems installed on each side of the wall between the top of the gypsum board and the bottom of the steel floor or roof deck or the spray -applied fire resistive material on the steel deck. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP606 Flexible Firestop Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. June 22, 2023 Hilt! Firestop Systems e:3of3 ASS ! Ff U� c us Underwriters Laboratories, Inc. to UL 2079 and CANIULC-S115 System No. HW-D-0184 ANSI/UL2079 Assembly Ratings —1 and 2 Hr (See Item 2) Nominal Joint Width - 314 In. Class II Movement Capabilities —17% Compression or Extension L Rating At Ambient — Less Than 1 CFM/lin ft L Rating At 400 F — Less Than 1 CFM/lin ft CAN/ULC S115 F Ratings —1 and 2 Hr (See Item 2) FT Ratings —1 and 2 Hr (See Item 2) FH Ratings —1 and 2 Hr (See Item 2) FTH Ratings —1 and 2 Hr (See Item 2) Nominal Joint Width - 3/4 In. Class II Movement Capabilities —17% Compression or Extension L Rating At Ambient — Less Than 1 CFM/lin ft L Rating At 400 F — Less Than 1 CFM/Iln ft MEL. Md Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. Hilti Firestop Systems June 26,2023 1 of 3 System No. HW-D-0184 1. Floor Assembly — The fire -rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner described in the individual D700 or D900 Series Floor -Ceiling Design in the UL Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Form Units` — Max 3 in. (76 mm) deep galv steel fluted units. B. Concrete — Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units. C. Spray -Applied Fire Resistive Materials (Optional) — (Not Shown) — Prior to or after the installation of the ceiling runner and prior to the installation of the Fill, Void or Cavity Materials (Items 2A and 3), the steel floor units may be sprayed with a min 5/16 in. (8 mm) thickness to a max 11 /16 in. (17 mm) thickness of fire resistive material. GCP APPLIED TECHNOLOGIES INC Type MK-61HY 1 A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P900 Series Roof -Ceiling Design in the UL Fire Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall assembly. The roof assembly shall include the following construction features: A. Steel Roof Deck — Max 3 in. (76 mm) deep galv steel fluted roof deck. B. Roof Insulation — Min 2-1/4 in. (57 mm) thick poured insulating concrete, as measured from the top plane of the floor units. 1 B. Roof Assembly — As an alternate to Items 1 and 1 A, a fire rated protected fluted steel deck roof assembly may be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P700 Series Roof -Ceiling Design in the UL Fire Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall assembly. The roof assembly shall include the following construction features: A. Steel Roof Deck — Max 3 in. (76 mm) deep galv steel fluted roof deck. B. Spray —Applied Fire Resistive Materials* — (Not Shown) —Prior to or after the installation of the steel ceiling runners, and prior to the installation of the Forming Material and Fill, Void or Cavity Material (Items 2A, 3A, 3B), the roof assembly shall be sprayed with the type and thickness of fire resistive material indicated in the individual P700 Series design. 2. Wall Assembly — The 1 or 2 hr fire rated gypsum board/steel stud wall assembly shall be constructed of the materials and in the manner described in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Ceiling Runners — Floor and ceiling runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized to accommodate steel studs (Item 2C). Flange height of ceiling runner shall be min 114 in. (6 mm) greater than max extended joint width. Ceiling runner installed parallel to direction of fluted steel deck, centered beneath valley, and secured with steel masonry anchors, steel fasteners or welds spaced max 24 in. (610mm) OC before or after optional spray -applied fire resistive material is used. The use of welds to secure the ceiling runner may only be used prior to the installation of the optional spray -applied material. Al. Light Gauge Framing' - Slotted Ceiling Runner — As an alternate to the ceiling runner in (Item 2A), slotted ceiling runner to consist of galv steel channel with slotted flanges sized to accommodate steel studs (Item 2C). Ceiling runner installed parallel to direction of fluted steel deck, centered beneath valley, and secured with steel masonry anchors, steel fasteners or welds spaced max 24 in. (610mm) OC before or after optional spray -applied fire resistive material is used. The use of welds to secure the ceiling runner may only be used prior to the installation of the optional spray -applied material. BRADY CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS — SLP-TRK CEMCO, LLC —CST CLARKDIETRICH BUILDING SYSTEMS — Type SLT, SLT-H RAM SALES L L C — RAM Slotted Track SCAFCO STEEL STUD MANUFACTURING CO TELLING INDUSTRIES L L C — True -Action Deflection Track MARINO/WARE, DIV OF WARE INDUSTRIES INC —Type SLT Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. June 26, 2023 Hilt! Firestop Systems 0 0 Page: 2 of 3 System No. HW-D-0184 A2. Light Gauge Framing* - Vertical Deflection Ceiling Runner —As an alternate to the ceiling runners in Items 2A and 2A1, vertical deflection ceiling runner to consist of galv steel channel with slotted vertical deflection clips mechanically fastened with runner. Slotted clip provided with step bushings for permanent fastening of steel studs. Flanges sized to accommodate steel studs (Item 2C). Vertical deflection ceiling runner installed parallel to direction of fluted steel deck, centered beneath valley, and secured with steel masonry anchors, steel fasteners or welds spaced max 24 in. (610mm) OC before or after optional spray -applied fire resistive material is used. The use of welds to secure the ceiling runner may only be used prior to the installation of the optional spray -applied material. A3. Light Gauge Framing*- Notched Ceiling Runner— As an alternate to the ceiling runners in Items 2A through 2A2, notched ceiling runners to consist of C-shaped galv steel channel with notched return flanges sized to accommodate steel studs (Item 2C). Notched ceiling runner installed parallel to direction of fluted steel deck, centered beneath valley, secured with steel masonry anchors, steel fasteners or welds spaced max 24 in. (610mm) OC before or after optional spray -applied fire resistive material is used. The use of welds to secure the ceiling runner may only be used prior to the installation of the optional spray -applied material. OLMAR SUPPLY INC — Type SCR B. Steel Attachment Clips — (Optional - Not Shown) - When spray applied fireproofing is used ceiling runner may be secured to deck with Z-shaped clips formed from min. 1 in. (25 mm) long strips of min 20 ga galv steel. Length of clips should not exceed the width (thickness) of the wall. Clips to be sized to extend through the thickness of the spray -applied fire -resistive material on the bottom of the steel deck with 1-1/2 or 2 in. (38 or 51 mm) long upper and lower legs. Legs of clips fastened to valleys of steel deck (prior to application of spray -applied fire -resistive materials) and top of ceiling runner with steel fasteners or welds. Clips spaced max 24 in. (610 mm) OC. C. Studs — Steel studs to be min 3-5/8 in. (92 mm) wide. Studs cut 1/2 to 3/4 in. (13 to 19 mm) less in length than assembly height with bottom nesting in and resting on floor runner and with top nesting in ceiling runner without attachment. When slotted ceiling runner (Item 2A1) is used, steel studs secured to slotted ceiling runner with No. 8 by 1/2 in. (13 mm) long wafer head steel screws at midheight of slot on each side of wall. When vertical deflection ceiling runner (Item 2A2) is used, steel studs secured to slotted vertical deflection clips, through bushings, with steel screws at midheight of each slot. Stud spacing not to exceed 24 in. (610 mm) OC. D. Gypsum Board* — For 1 hr assembly, one layer of 5/8 in. (16 mm) thick gypsum board is required in the individual Wall and Partition Design. For 2 hr assembly, two layers of 518 in. (16 mm) thick gypsum board is required in the individual Wall and Partition Design. For both hourly ratings, a nominal 3/4 in. (19 mm) gap shall be maintained between the top of the gypsum board and the bottom surface of the steel deck and the top row of screws shall be installed into the studs 3 in. (76 mm) below the valleys of the steel floor units. The hourly fire rating of the joint system is equal to the hourly rating of the wall. 3. Fill, Void or Cavity Material* — Sealant - Max separation between bottom of floor or roof and top of wall is 3/4 in. (19 mm). The joint system is designed to accommodate a max 17 percent compression or extension from its installed width. Min 5/8 in. (16 mm) thickness of fill material installed on each side of the wall between the top of the gypsum board and the bottom of the steel deck, flush with each surface of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 601S Elastomeric Firestop Sealant or CP 606 Flexible Firestop Sealant or CFS-S SIL GG Sealant. L Ratings apply when CP 606 or CFS-S SIL GG Sealant is used. 4. Forming Material — (Optional, Not Shown) - Mineral wool insulation, fiberglass batt insulation or polyurethane/polyethylene foam backer rod. Forming material to be recessed from both surfaces of the 2 hr fire rated wall to accommodate the required thickness of fill material. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. Hilt! Firestop Systems June 26, 2023 Page: 3 of 3 ���SIFfD System No. W-L-1297 C 1J5FRating NSI/UL2079 (ASTM E814) Classified by Underwriters Laboratories, Inc.1 and 2 Hr (See Item 1) to UL 1479 and CANIULC-S115 0 Hr L Rating at Ambient — Less than 1 CFM/Sq Ft L-Rating At 400' — Less Than 1 CFM/Lin Ft Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. July 07, 2020 Hilt! Firestop Systems ti as N r CAN/ULC S115 F Ratings —1 and 2 Hr (See Item 1) FT Rating — 0 Hr FH Ratings —1 and 2 Hr (See It1) FTH Rating — 0 Hr L-Rating At Ambient — Less Than 5.1 L/s/mz L-Rating At 2040 — Less Than 5.1 L/sle 1 of 2 System No. W-L-1297 ti N r 1. Wall Assembly — The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features. A. Studs — Wall framing shall consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* — Nom 5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300, U400, V400 or W400 Series Design in the Fire Resistance Directory. Max diam of opening is 32 in. (813 mm). The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant — One metallic pipe, conduit or tubing installed concentrically or eccentrically within the firestop system. Pipe, conduit or tube to be rigidly supported on both sides of wall assembly. The annular space between the pipe, conduit or tube and periphery of the opening shall be min 0 in (0 mm, point contact) to max 2 in. (51 mm) in 2 hr fire rated walls and min 0 in (0 mm, point contact) to max 1 in. (25 mm) in 1 hr fire rated walls. As an option, for through penetrant types 2A, 2B and 2C only in nom diameters not exceeding 4 in. (102 mm), the penetrant can be installed with continuous point contact. The following types and sizes of metallic pipes, conduit or tube may be used: A. Steel Pipe — Nom 30 in. (762 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe. B. Iron Pipe — Nom 30 in. (762 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or 6 in. diam steel conduit. D. Copper Tube — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tube. E. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -Sealant — Min 5/8 in. (16 mm) or 1-1/4 in. (32 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall, for 1 hr and 2 hr fire rated wall assemblies, respectively. A min 1/2 in. (13 mm) diam bead of fill material shall be applied at the pipelwall interface at the point contact and continuous point contact location. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP606 Flexible Firestop Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of M2= Underwriters Laboratories, Inc. Hilt! Firestop Systems July 07,2020 2of2 3S5 I F� C us Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN1ULC-S115 System No. W-L-1465 ANSI/UL1479 (ASTM E814) F Rating —1 or 2 Hr (See Item 1) T Rating — 0 and 114 Hr (See Item 1) L Rating At Ambient — Less Than 1 CFM/Sq Ft L Rating At 400 F — Less Than 1 CFM/Sq Ft CAN/ULC S115 F Ratings —1 or 2 Hr (See Item 1) FT Rating — 0 and 1/4 Hr (See Item 1) FH Rating —1 or 2 Hr (See Item 1) FTH Rating —0 and 1/4 Hr (See Item 1) L Rating At Ambient — Less Than 1 CFM/Sq Ft L Rating At 400 F — Less Than 1 CFM/Sq Ft SECTION A -A co Wall Assembly — The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced max 16 in. (406 mm) OC. Steel studs to be min 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* — Thickness, type, number of layers and orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 10 in. (254 mm). The hourly F, FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. The T, FT, FTH Ratings are 0 and 1/4 hr for 1 and 2 hr rated wall assemblies, respectively. 2. Steel Sleeve — Cylindrical sleeve fabricated from min 0.016 in. (0.41 mm) thick galv sheet steel and having a min 1 in. (25 mm) lap along the longitudinal seam. Sleeve installed by coiling the sheet steel to a diam smaller than the through opening, inserting the coil through the openings and releasing the coil to let it uncoil against the circular cutouts in the gypsum board layers. The ends of the steel sleeve shall be flush with or extend max 1 in. (25 mm) beyond each surface of the wall. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. Hilti Firestop Systems January 26, 2015 page:1 of 2 System No. W-L-1465 3. Through Penetrants — One metallic pipe, conduit or tubing installed either concentrically or eccentrically within the firestop system. The annular space between pipe, conduit or tubing and periphery of sleeve shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe — Nom 8 in. (203 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe — Nom 8 in. (203 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing or nom 6 in. (152 mm) steel conduit. D. Copper Tubing — Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe — Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe. Configuration A 4. Fill, Void or Cavity Material* — Sealant — Min 1 in. (25 mm) thickness of sealant applied within annulus, flush with both ends of sleeve. A min 1/4 in. (6 mm) diam bead of sealant to be applied at the tubing/sleeve interface at the point contact location and around the entire perimeter of the sleeve at the sleeve/gypsum board interface when the sleeve extends beyond the wall surface. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 606 Sealant, FS ONE Sealant or FS-ONE MAX Intumescent Sealant Configuration B 4. Firestop System — The firestop system shall consist of the following items: A. Packing Material — Min 5/8 in. (16 mm) thickness of min 4 pcf Mineral wool bat insulation compressed and tightly and packed in to each end of the sleeve. Packing material is to be recessed from each end of the sleeve to accommodate fill material. Al. Packing Material* - Strips — (As an alternate to Config ,B Item 4A) - Nom 5/8 in. in. (16 mm) wide precut mineral wool strips. The strips are firmly packed into the gap between penetrant and the steel sleeve Item 2 on both sides of the wall. Packing material is to be recessed from each end of the sleeve to accommodate fill material. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 767 Speed Strips B. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of sealant applied within annulus, flush with both ends of sleeve. A min 1/4 in. (6 mm) diam bead of sealant to be applied at the tubing/sleeve interface at the point contact location and around the entire perimeter of the sleeve at the sleeve/gypsum board interface when the sleeve extends beyond the wall surface. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 606 Sealant or FS ONE Sealant or FS-ONE MAX Intumescent Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of E�111111111�� Underwriters Laboratories, Inc. Hilt! Firestop Systems January 26, 2015 e: 2 of 2 �,SSIF� classified by Underwriters Laboratories, Inc. to UL 1479 System No. W-L-2128 F Rating —1 and 2 Hr (See Item 1) T Rating — 0 Hr SECTION A -A 0o N N Wall Assembly — The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-112 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (122 cm) wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 3-1/2 in. (89 mm). !. Metallic Sleeve Optional — Nom 3-1/2 in. (89 mm) (or smaller) cylindrical sleeve fabricated from min 0.016 in. thick (28 gauge) gaiv sheet steel and having a min 1-1/4 in. (32 mm) lap salong longitudinal seam. Length of sleeve to be installed flush with wall surfaces. 3. Through Penetrants — One nonmetallic pipe installed within the firestop system.. Pipe may be installed at an angle not greater than 45 degrees from perpendicular. Pipe to be rigidly supported on both sides of wall assembly. The space between pipe and periphery of opening shall be min 1/4 in. (6 mm) to max 11116 in. (17.5 mm). The following types and sizes of nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC pipe for use in closed (process or supply) I or vented (drain, waste or vent) piping systems. B. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 2 in. (51 mm) diam (or smaller) SDR13.5 CPVC pipe for use in closed (process or supply) piping systems. 4. Fill, Vold or Cavity Materials* — Sealant — For 1 hr F Rating, min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. For 2 hr F Rating, min 1-1/4 in. (32 mm) thickness of fill material applied within annulus, flush with both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant or FS-ONE MAX Intumescent Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of =M&ALJ Underwriters Laboratories, Inc. January 26, 2015 Hilt! Firestop Systems �C rF� Classified by Underwriters Laboratories, Inc. to UL 1479 A A System No. W-L-2406 F Ratings —1 and 2 Hr (See Item 1) T Ratings — 0,1/2 and 314 Hr (See Item 2) L Rating At Ambient -1.2 CFM/sq ft (See Item 313) L Rating At 400 F - Less Than 1 CFM/sq ft (See Item 313) SECTION A -A 1 Wall Assembly — The 1 or 2 hr fire -rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* — One or two layers of nom 5/8 in. (16 mm) thick gypsum board, as specified in the individual Wall and Partition Design. See Table under Item 3B for max diam of opening. 2. Through -Penetrants — One nonmetallic pipe installed within the firestop system, See Table under Item 3B for annular space required in the firestop system. Pipe to be rigidly supported on both sides of wall assembly. The following types and sizes of nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 cellular or solid core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping system. B. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 6 in. (152 mm) diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping system. C. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 40 cellular or solid core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping system. The T Rating for 2 hr fire -rated walls is 0 hr. The T Rating for 1 hr fire -rated walls is 3/4 hr for nom 1-112, 2 and 3 in. (38, 51 and 76 mm) diam through penetrants. The T Rating for 1 hr fire -rated walls is 1/2 hr for nom 4 and 6 in. (102 and 152 mm) diam through penetrants. QD N Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. HIM Firestop Systems January 26, 2015 Page: 1 of 2 1 F'�o System No. W-L-2406 m N �$s J Classified by Underwriters Laboratories, Inc. to UL 1479 3. Firestop System — The firestop system shall consist of the following; A. Fill, Void or Cavity Material* — Wrap Strip — See Table under Item 3B for min size of intumescent wrap strip. The wrap strip is continuously wrapped around the outer circumference of the pipe once and slid into the annular space such that approx 1/8 in. (3 mm) of the wrap strip protrudes from the wall surface. Wrap strip is held in place with integral fastening tape. Wrap strip installed on each surface of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 648S -1,5" US, CP 648S - 2" US, CP 648S - 3" US, CP 648S - 4" US and CP 648S - 6" US B. Fill, Void or Cavity Material* — Caulk — Min 1/4 in. (6 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. For 2 hr fire -rated walls,114 in. (6 mm) bead fill material also applied at wrap strip/gypsum wall interface. In 1 hr fire -rated walls, fill material is optional for nom 1-1/2, 2, 3 and 4 in. (38, 51, 76 and 102 mm) diam penetrants. In 2 hr fire -rated walls, fill material is optional for nom 1-1/2, 2 and 3 in. (38, 51 and 76 mm) diam penetrants. Fill material is required to be used to attain L Ratings. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant Nom Pipe Diam, in. (mm) Wrap Strip Wrap Strip Size, thick. X width, in. mm ( ) Max Diam of Opening, in. mm ( ) Annular Space, in. (mm) Min Max 1-1/2(38) CP 648S -1.5" US 3/16 x 1 (5 x 25) 2-318 (60) 3116 (5) 5/16 (8) 2 (51) CP 648S - 2" US 3/16 x 1 (5 x 25) 3 (76) 3/16 (5) 5/16 (8) 3 (76) CP 648S - 3" US 3/16 x 1-3/4 (5 x 44) 4 (102) 3/16 (5) 5/16 (8) 4 (102) CP 648S - 4" US 3/8 x 1-3/4 (10 x 44) 5-318 (137) 3/8 (10) 1/2 (13) 6 (152) CP 648S - 6" US 1/2 x 1-3/4 (13 x 44) 8 (203) 9116 (14) 13116 (21) * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 26, 2015 Hilti Firestop Systems Page: 2 of 2 us classified by Underwriters Laboratories, Inc. to UL 1479 and CANIULC-S115 System No. W-L-5027 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating — 2 Hr T Rating —1/2 Hr L Rating At Ambient — Less Than 1 CFM/sq ft L Rating At 400 F — Less Than 1 CFM/sq ft F Rating — 2 Hr FT Rating —112 Hr FH Rating — 2 Hr FTH Rating —1/2 Hr L Rating At Ambient — Less Than 1 CFM/sq ft L Rating At 400 F — Less Than 1 CFM/sq ft SECTION A -A 1. Wall Assembly — The fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* — Two layers of 5/8 in. (16 mm) thick gypsum wallboard, as specified in the individual Wall and Partition Design. Max diam of opening is 6 in. (152 mm). 2. Metallic Sleeve — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 (or thinner) steel pipe cast into wall assembly with joint compound and installed flush with wall surfaces. Reproduced by HILTI,.Inc. Courtesy of Underwriters Laboratories, Inc. Hilt! Firestop Systems January27, 2015 rl— N O to 1 of 2 System No. W-L-5027 3. Through Penetrants — One metallic pipe or tubing to be centered within the firestop system. Pipe or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or tubing may be used: A. Steel Pipe — Nom 2 in. (51 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe. B. Copper Tubing — Nom 2 in. (51 mm) diam (or smaller) Type L (or heavier) copper tubing. C. Copper Pipe — Nom 2 in. (51 mm) diam (or smaller) Regular (or heavier) copper pipe. 4. Tube Insulation — Plastics+ — Nom 314 in. (19 mm) thick acrylonitrile butadienelpolyvinyl chloride (AB/PVC) flexible foam furnished in the form of tubing. An annular space of min 1-3116 in. (30 mm) to max 1-518 in. (41 mm) is required within the firestop system. See Plastics+ (QMFZ2) category in the Recognized Component Directory for names of manufacturers. Any Recognized Component tube insulation material meeting the above specifications and having a UL 94 Flammability Classification of 94-5VA may be used. 5. Packing Material — Min 3-112 in. (89 mm) thickness of min 4.0 pcf (64 kglm3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from both surfaces of wall as required to accommodate the required thickness of fill material. 6. Fill, Void or Cavity Material* — Sealant — Min 314 in. (19 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant or FS-ONE MAX Intumescent Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 27, 2015 Hilti Firestop Systems ti N 0 W) e: 2 of 2 SS IA-, CVWIPFUs Classified by Underwriters Laboratories, Inc. to UL 1479 and CANNLCS115 System No. W-L-5096 ANSI/UL1479 (ASTM E814) CANIULC S115 F Ratings -1 and 2 Hr (See Item 1) F Ratings -1 and 2 Hr (See Item 1) T Ratings - 0, 112 and 1 (See Items 3 and 4) FT Ratings - 0, 1/2 and 1 (See Items 3 and 4) FH Ratings -1 and 2 Hr (See Item 1) FTH Ratings - 0, 1 /2 and 1 (See Items 3 and 4) I A 1 k1m,"w"MAZ r �f 1B SECTION A -A Wall Assembly — The 1 or 2 hr fire rated wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing shall consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* — Nom 518 in. (16 mm) thick, 4 ft (1.2 m) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300, U400, V400 or W400 Series Design in the Fire Resistance Directory. Max diam of openings is 14-1/2 in. (368 mm) for wood stud walls. Max diam of opening is 18-5/8 in. (473 mm) for steel studs walls or sized to the outside diam of steel sleeve (Item 2) when optional steel sleeve is used. The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. Steel Sleeve — (Optional) Max 18 in. (457 mm) diam Schedule 40 (or heavier) steel pipe sleeve inserted in opening core drilled through wall. Length of steel sleeve to be equal to thickness of wall. I— t -.N:jm Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. Hilt! Firestop Systems March 30,2015 cc 0 1 of 2 System No. W-L-5096 3. Through Penetrant — One metallic pipe or tubing installed concentrically or eccentrically within the firestgp system. Pipe or tube to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or tube may be used: A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe. When steel pipe is used, T, FT and FTH Ratings are 112 hr and 1 hr when installed in 1 and 2 hr rated walls, respectively. B. Copper Tube — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tube. When copper tube is used, T, FT and FTH Ratings are 1/2 hr and 1 hr when installed in 1 and 2 hr rated walls, respectively. C. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. When copper pipe is used, T, FT and FTH Ratings are 1/2 and 1 hr when installed in 1 and 2 hr rated walls respectively. 4. Pipe Covering* — Max. 2 in. (51 mm) thick hollow cylindrical heavy density (nom 3.5 pcf or 56 kg/m3) glass fiber units, jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory -applied SSL tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. The annular space between insulated penetrant and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). When pipe covering thickness is less than 2 in. (51 mm), T, FT and FTH Ratings are 0 hr. See Pipe and Equipment Covering -Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. 5. Fill, Void or Cavity Material* -Sealant — Min 518 in. (16 mm) or thickness of fill material applied within annulus, flush with both surfaces of wall assembly for At point contact an additional 1/2 in. (13 mm)bead of sealant shall be applied to the insulated pipe/ wall interface. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant or FS-ONE MAX Intumescent Sealant * Indicates such products shall bear the UL or cUL Certification Mark forjurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. March 30, 2015 Hilti Firestop Systems J Page: 2 of 2 �,55 I Fr C us Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 System No. W-L-7042 ANSI/UL1479 (ASTM E814) F Ratings -1 and 2 Hr (See Items 1 and 3) T Rating - 0 Hr CAN/ULC S115 F Ratings -1 and 2 Hr (See Items 1 and 3) FT Rating - 0 Hr FH Ratings -1 and 2 Hr (See Items 1 and 3) FTH Rating - 0 Hr SECTION A -A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. HIM Firestop Systems October 12, 2017 4 0 J Page:1 of 2 System No. W-L-7042 Wall Assembly — The 1 or 2 hr fire rated wallboardistud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features. A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced 24 in. (610 mm) OC. Additional framing members shall be used to completely frame the opening for all ducts greater than 20 in. (502 mm) diam. B. Gypsum Board* — For 1 hr assembly, one layer of min 518 in. (16 mm) thick wallboard as required in the individual Wall and Partition Design. For 2 hr assembly, two layers of min 518 in. (16 mm) thick wallboard as required in the individual Wall and Partition Design. Max diam of opening is 14-112 in. (368 mm) for wood stud walls and 25-112 in. (648 mm) for steel stud walls. The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant — Galy steel duct to be installed concentrically or eccentrically within the firestop system. The annular space between the duct and periphery of opening shall be 0 in. (0 mm, point contact) and max 1-112 in. (64 mm) Duct to be rigidly supported on both sides of wall assembly. A. Spiral Wound HVAC Duct — Nom 24 in. ( 610 mm) diam (or smaller) No. 28 MSG (or heavier) gals steel spriral wound duct. B. Sheet Metal Duct — Nom 12 in. (305 mm) diam (or smaller) No. 28 MSG (or heavier) galv sheet steel duct. 3. Fill, Void or Cavity Material* —Sealant — Min 5/8 in. (16 mm) and 1-114 in. (32 mm) thickness of fill material applied within annulus, flush with both surfaces of wall assembly for 1 and 2 hr F Ratings, respectively. When FS-ONE Max is used, min 518 in. (16mm) thickness for both 1 and 2 hr F Ratings. At the point contact location between duct and wallboard, a min 1/2 in. (13 mm) diam bead of sealant shall be applied at the wallboard/duct interface on both surfaces of wall assembly. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601S Elastomeric Firestop Sealant, FS-ONE Sealant, FS-ONE MAX Intumescent Sealant or CP606 Flexible Firestop Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of ftJUnderwriters Laboratories, Inc. October 12, 2017 Hilti Firestop Systems N d' 0 ti Page: 2 of 2 U�$S r Fffid CVAVUs Classified by Underwriters Laboratories, Inc. to UL 1479 and CANIULC-S115 System No. W-L-7153 ANSI/UL1479 (ASTM E814) F Ratings -1 and 2 Hr (See Item 1) T Rating -1/2 Hr I sm A CAN/ULC S115 F Ratings -1 and 2 Hr (See Item 1) FT Rating -1/2 Hr FH Ratings -1 and 2 Hr (See Item 1) FTH Rating -112 Hr SECTION A -A Wall Assembly — The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U400, V400 or W400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing shall consist of channel studs. Steel studs to be min 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. B. Wallboard, Gypsum* — 518 in. (16 mm) thick, 4 ft (122 cm) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design in the UL Fire Resistance Directory. Max diam of opening is 24 in. (610 mm). The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. IwT7 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. HIM Firestop Systems November 15, 2017 M Ln ti J Page: 1 of 2 System No. W-L-7153 2. Steel Duct — Galy steel duct to be installed concentrically or eccentrically within the firestop system. Duct to be rigidly supported on both sides of wall assembly. A. Spiral Wound HVAC Duct — Nom 20 in. (508 mm) diam (or smaller) No. 24 MSG (or heavier) galv steel spriral wound duct. B. Sheet Metal Duct — Nom 12 in. (305 mm) diam (or smaller) No. 28 MSG (or heavier) gals sheet steel duct. 3. Duct Insulation* — Nom 1-1/2 in. or 2 in. (38 or 51 mm) thick glass fiber batt or blanket (min 314 pcf or 56 kglm3) jacketed on the outside with a foil-scrim-kraft facing. Longitudinal and transverse joints sealed with aluminum foil tape. During the installation of the fill material, the batt or blanket shall be compressed 50% such that the annular space within the firestop system shall be min 114 in. (6 mm) to max 1-112 in. (38 mm). See Batts and Blankets - (BKNV) category in the Building Materials Directory for names of manufacturers. Any batt or blanket meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index 50 or less may be used. 4. Fill, Void or Cavity Material* — Sealant — Min 518 in. (16 mm) thickness of fill material applied within annulus, flush with both surfaces of wall. If voids develop after the fill materials cures, the voids shall be sealed with additional fill material. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant or FS-ONE MAX Intumescent Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. November 15, 2017 Hilti Firestop Systems M Ln T ti J 2of2 �.ss I F,fio G c VNW us Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 System No. W-L-7155 ANSI/UL1479 (ASTM E814) F Ratings —1 and 2 Hr (See Item 1) T Ratings — 0 Hr L Rating at Ambient — Less Than 1 CFM/sq ft L Rating at 400 F — Less Than 1 CFM/sq ft CAN/ULC S115 F Ratings —1 and 2 Hr (See Item 1) FT Ratings — 0 Hr FH Ratings —1 and 2 Hr (See Item 1) FTH Ratings — 0 Hr L Rating at Ambient — Less Than 1 CFM/sq ft L Rating at 400 F — Less Than 1 CFM/sq ft 1. Wall Assembly — The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U400, V400 or W400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing shall consist of min 3-1/2 in. (89 mm) wide steel channel studs spaced max 24 in. (610 mm) OC. Additional steel studs shall be used to completely frame the opening. B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design in the UL Fire Resistance Directo Max area of opening is 73.7 sq ft (6.85 m2) with a max dimension of 104 in. (2.64 m). ry. The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. 2. Steel Duct — Max 100 in. by 100 in. (2.5 by 2.5 m) galv steel duct to be installed either concentrically or eccentrically within the firestop system. The duct shall be constructed and reinforced in accordance with SMACNA construction standards. The space between the steel duct and periphery of opening shall be min 0 in. (point contact) to max 2 in. (51 mm). Steel duct to be rigidly supported on both sides of the wall assembly. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. HIM Firestop Systems December 26, 2017 Page: 1 of 2 7 Ln System No. W-L-7155 2A1. Through-Pentrating Product* — As an alterate to Item 2. Fiber cement with galvanized steel facing, 3/8 in.(10 mm) thick composite metallic duct, with a max cross -sectional area of 43.0 sq It, (4 m2) and a max individual dimension of 78 3/4 in. (2 m). Duct to be installed either concentrically or eccentrically within the firestop system such that the annular space is min 0 in. (point contact) to max 2 in. (51 mm). Duct to be rigidly supported on both sides of wall assembly. Refer to Ventilation Duct Assemblies in Vol. 2 of the Fire Resistance Directory. DURASYSTEMS BARRIERS INC — Type DuraDuct HP. 2A2. Through-Pentrating Product* —As an alternate to Item 2. Fiber cement with galvanized steel facing, 114 in. (6 mm) thick, with a max cross -sectional area of 1764 sq in. (1.14 m2), and a max individual dimension of 42 in. (1067 mm). Duct to be installed either concentrically or eccentrically within the firestop system such that the annular space is min 0 in. (point contact) to max 2 in. (51 mm). Duct to be rigidly supported on both sides of wall assembly and installed in accordance. Refer to Ventilation Duct Assemblies in Vol. 2 of the Fire Resistance Directory. DURASYSTEMS BARRIERS INC — Type DuraDuct SD. 2A3. Through-Pentrating Product* — As an alternate to Item 2. Galvanized steel faced duct panel, with a max cross -sectional area of 2450 sq in. to be installed either concentrically or eccentrically within the (1.58 m2), and a max individual dimension of 49-1/2 in. (1258 mm) Duct firestop system such that the annular space is min 0 in. (point contact) to max 2 in. (51 mm). Duct to be rigidly supported on both sides wall assembly. Refer to Ventilation Duct Assemblies in Vol. 2 of the Fire Resistance Directory. DURASYSTEMS BARRIERS INC — Type DuraDuct GNX. 3 Firestop System — The firestop system shall consist of the following: A. Packing Material — (Optional, Not Shown) — Polyethylene backer rod, mineral wool batt insulation or fiberglass batt insulation friction fitted into annular space. Packing material to be recessed from both surfaces of wall to accommodate the required thickness of fill material. Al. Packing Material — Required as specified in Table below. Min 3-3/4 in. (95 mm) or 5 in. (127 mm) thickness of min 4 pcf (64 kglm3) mineral wool batt insulation firmly packed into opening as a permanent form for 1 and 2 hr rated assemblies, respectively. Packing material to be recessed from both surfaces of wall to accommodate the required thickness of fill material. B. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. Min 114 in. (6 mm) diam bead of fill material shall be applied at the point contact location between the steel duct and the gypsum board. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CFS-S SIL GG Sealant, FS-ONE Sealant, FS-ONE MAX Intumescent Sealant or CP606 Flexible Firestop Sealant C. Steel Retaining Angles — Min No.16 gauge galv steel angles sized to lap steel duct a min of 2 in. (51 mm) and to lap wall surfaces a min of 1 in. (25 mm). When max duct dimension does not exceed 48 in. (122 cm) and duct area does not exceed 1300 in2 (8387 cm2), angles may be min No.18 gauge galv steel. Angles attached to steel duct on both sides of wall with min No.10 by 112 in. (13 mm) long steel sheet metal screws located a max of 1 in. (25 mm) from each end of steel duct and spaced a max of 6 in. (152 mm) OC. Steel angles are optional for those sides of duct that do not exceed the dimension specified in Table below, dependent on packing material, sealant and annular space as specified. Angle Max Duct Packing (Item 3C) Dimension Duct Thj6ace Material Required 24 in. 24 ga oin. max Item 3A1 No (610 mm) 25 mm) * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. December 26, 2017 Hilti Firestop Systems Paw: 2 of 2 �55 l,cr c us Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-5115 System No. W-L-7156 ANSI/UL1479 (ASTM E814) F Ratings —1 and 2 Hr (See Item 1) T Rating — 0, 1 and 2 Hr (See Item 4C) CAN/ULC S115 F Ratings —1 and 2 Hr (See Item 1) FT Rating — 0,1, and 2 Hr (See Item 4C) FH Ratings —1 and 2 Hr (See Item 1) FTH Rating — 0,1, and 2 Hr (See Item 4C) Wall Assembly — The 1 or 2 hr fire -rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing shall consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced max 16 in. (406 mm) OC. Steel studs to be min 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. Additional framing members shall be used to completely frame around opening. B. Gypsum Board* — Min 5/8 in. (16 mm) thick, 4 ft (1.2 m) wide with square or tapered edges. The gypsum board type, thickness, number of layers and orientation shall be as specified in the individual Wall and Partition Design. Max size of opening is 210 sq in. (1355 cm2) with a max width of 14-1/2 in. (368 mm) for wood studs. Max size of opening is 76.2 sq ft. (7 m2) with a max width of 105-1/2 in. (2.7 m) for steel studs. The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall in which it is installed. Steel Duct — Max 100 by 100 in. (2.5 by 2.5 m) steel duct to be installed within the framed opening. The duct shall be constructed and reinforced in accordance with SMACNA construction standards. Steel duct to be rigidly supported on both sides of wall assembly. Reproduced by HILTI, Inc. Courtesy of C2= Underwriters Laboratories, Inc. Hilt! Firestop Systems August 22, 2018 Page: 1 of 2 to Uj System No. W-L-7156 3. Batts and Blankets* — Nom 1-1/2 or 2 in. (38 or 51 mm) thick glass fiber batt or blanket (min 3/4 pcf or 12 kglm3) jacketed on the outside with a foil-scrim-kraft facing. Longitudinal and transverse joints sealed with aluminum foil tape. During the installation of the fill material, the batt or blanket shall be compressed minimum 50% such that the annular space within the Firestop system shall be min 1/2 in. (13 mm) to max 3-1/2 in. (89 mm); refer to the table below. See Batts and Blankets (BKNV) category in the Building Materials Directory for names of manufacturers. Any batt or blanket meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index 50 or less may be used. 4. Firestop System — The firestop system shall consist of the following: A. Packing Material — Min f 5m8 (91 or 2 hr fire/ ain. (124s, respectivelmm) thickn y. Packing material alk of be recessed from both surfaces of m3) mineral wool batt insulation lall to packed into opening as a permanent accommodate the required thickness of fill material. B. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. (16 mm) thickness of fill material applied within annulus, flush with both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE MAX Intumescent Sealant C. Steel Retaining Angles — Min No.16 gauge (0.059 in. or 1.5 mm) galv steel angles sized to lap steel duct a min of 2 in. 51 mm) and lap wall surfaces a min of 1 in. (25 mm). Angles attached to steel duct on both sides of wall with min No.10 steel sheet metal screws spaced a max of 1 in. (25 mm) from each end of steel duct and spaced a max of 6 in. (152 mm) OC. When max duct dimension does not exceed 48 in. (122 cm) and duct area does not exceed 1300 in2 (8387 cm2), angles may be min No.18 gauge gals steel. Angles attached to steel duct on both sides of wall with min No.10 by 112 in. (13 mm) long steel sheet metal screws located a max of 1 in. (25 mm) from each end of steel duct and spaced a max of 6 in. (152 mm) OC. In addition, see table below for additional conditions and options regarding retaining angles. Max Packing Angle (Item Max Duct Duct Insulation Annular Material 4C) T-Rating Hr Dimension Thickness Thickness Space (Item 4A) Required Required (Item 3) **24 in. (610 24 ga or in. 38 1-1/2 ( 114 in. min to 1 in, max (6 No No 0 mm) heavier mm) to 25 mm) 25 in. (635 114 in. min to 1 and 2 mm) wide by 24 ga or 2 in. (51 3-1/2 in. Yes No (Same as 45 in. (1143 heavier mm) max (6 to 89 wall rating) mm) high mm) ** Indicates that when max 1-1/2 in. (38 mm) thick insulation is used, steel angles are optional for those sides of the duct that do not exceed the dimension specified. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. August 22, 2018 HIM Firestop Systems Page: 2 of 2 FIRESTOP GUN GRADE SILICONE SEALANT CFS-S SIL GG Product description A silicone based firestop sealant that provides maximum movement in fire -rated joints, and seals through -penetration applications Product features • Halogen and solvent free • Asbestos free • Simple to use and apply • Good adhesion without use of a primer • Excellent movement capability, meets 500 cycle requirements (ASTM C719 and UL 2079) Areas of application • Smoke, fume, water and UV resistant • Meets Class I W-rating requirements • Meets LEEDTM requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings • Sealing construction/expansion joints • Cable bundles • Top -of -wall joints • HVAC penetrations • Metal pipes For use with • Various base materials such as masonry, concrete, metal, etc. • Wall and floor assemblies rated up to 4 hours Examples Product information MII�TI et' �w • Where a gypsum wall assembly meets the underside of a metal or concrete deck - - • Sealing expansion joints to impede the passage of fire, smoke and toxic fumes -— • Sealing around penetrations through fire -rated assemblies Installation instructions • See Hilti literature or third -party listings for complete application and installation details Technical data Chemical basis Density Color Application temperature Storage Temperature Skin -forming time Tack free time Curing time Volume shrinkage Movement capability UL 2079 ASTM C 920 FBC I Lubrizoll compatible Intumescent LEED VOC LEED V4 Compliant Mold and mildew Shelf life Water ti htness W-rating CSFM approval Neutral elastic silicone 87.4 Ids Available in red, white, and gray 351E to 1041E 1.5C to 4012' 35°F to 1041E 1.51C to 401C Approx. 15 min. 30mins ventilated at 771F, 80% rel. humidit 4mm 3 days Approx. 0 - 5% Up to 33% Order Information Designation Legend hem number Firestop sealant CFS-S SIL GG pail red 10 2076883 Firestop sealant 2076881 CFS-S SIL GG cart red Firestop sealant CFS-S SIL GG foil red 2076882 Firestop sealant CFS-S SIL GG foil white 2076729 Firestop sealant 2077322 CFS-S SIL GG foil grey Yes NO Ssta FILL, VOID OR CAvm' MATERIAL 4�L I+ a`P �Fo FOR USE IN THROUGH -PENETRATION FIRESTOP SYSTEMS AND Yes (CDPH 1.2-2017 C� JOINT S Class 0 IASTM G21-96 SEE UL FIRE RESISTANCE DIRECTORY 12 months 58P5 Yes FM FB4 1W Yes Yes (Listing 4485-1200:0123 for Through- eO1� Penetrations & 1452-1200:0113 for'oint s stems APPROVED Vnft tnear•aaw rVdble.°om. � Temperature resistance FBCTMisauad• kaf �•,,, Surface burning characteristics -401F to 300°F I-401C to 149°C) ZU&rk ICaplratlol Flame spread: 0 ASS TME84-12) Smoke development:25 volume per unit: Surface burning characteristics _ Flame spread: 0 Caulk tube - 10.5 f. oz (18.9w) CAN S102 Smokeenvelopment: 35 Foil - 600ml (36.4in� Pail -5gal(1,155ina) Sound transmission classification 59 (Relates to specific construction) Definition - For ambient and surface temperatures between ASTM E 90-09 10°F (-12°C) and 35•F, the following conditions must apply: Tested in accordance with — UL 2079, ASTM E 814, ASTM E 1 666, • Substrate surfaces are clean and dry (e.g. free of dust, rust, ASTM C 920, UL 1479, ASTM E 84, ASTM G21, grease, oil, dew, frost, ice, moisture, etc); Product maintained above 505F (10•0) for a minimum of 24 hours CAN ULC S102. CAWULC-S115 prior to application; • Product will not cure at ambient temperatures below 32°F / 0•C Hilt! Firestop ■ Saving lives © © a through innovation Tube and education Im 0 co CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register / Vol. 77, No. 581 Monday, March 26, 20121 Rules and Regulations Revision date: 9/26/2022 Issue date: 9/26/2022 Supersedes: 5/26/2020 Version: 3.3 1.1_. Identification_ Product form Mixture Product name CFS-S SIL SL / CFS-S SIL GG Product code BU Fire Protection 11.2 Recommended use and rpgopt ons on -use Use of the substance/mixture Firestop silcone sealant 1i,3. Supplier Supplier Hilti, Inc. Legacy Tower, Suite 1000 7250 Dallas Parkway Plano, TX 75024 USA T +1 9724035800 1-800-879-8000 toll free - F +1 918 254 0522 11.11 11 prp rprigy telephone numper Emergency number Department issuing data specification sheet Hilti AG FeldkircherstraQe 100 Schaan, 9494 Liechtenstein T +423 234 2111 chemicals.hse hilti.com Chem-Trec Tel.: 1 800 424 9300 (USA, PR, Virgin Islands, Canada) Tel.: 703 527 3887 (Other countries) +1 918 8723000 1-800-879-8000 toll free �2_1.Isslcaton of the substance pr mixtu_re GHS-US classification Skin sensitisation, Category 1 H317 May cause an allergic skin reaction. H361 Suspected of damaging fertility or the unborn child. Reproductive toxicity, Category 2 Full text of H-statements: see section 16 2.2. GHS_Label elements, including precautionary statements GHS US labelling Hazard pictograms (GHS US) Signal word (GHS US) Warning Hazard statements (GHS US) H317 - May cause an allergic skin reaction. H361 - Suspected of damaging fertility or the unborn child. Precautionary statements (GHS US) P261 - Avoid breathing vapours. P280 - Wear protective gloves, protective clothing, eye protection. 09/26/2022 US -OSHA - an Page 1 CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register I Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations P302+P352 - If on skin: Wash with plenty of water. P308+13313 - If exposed or concerned: Get medical advice/attention. 2.8. Other hazards which do not result m class_ ification Other hazards which do not result in classification In use the product releases 2-butanone oxime (methyl ethyl ketoxime; MEKO) (0-24h: <0.2%/h & 24-48h: <0.02%/h) which vaporises. In cases of prolonged exposure MEKO may damage nasal membranes. If MEKO is inhaled in large quantities over prolonged periods of time there may be irreversible damage to health: H351: Suspected of causing cancer. f2,4. Unknown acute toxicty_(GHS_ll$)- Not applicable SECTION 3: Composition/information on ingredients Not applicable 3.2. Mixtures Name Methyltris(1-methylpropylideneam inooxy)silane Titanium dioxide octamethylcyclotetrasiloxa ne Full text of hazard classes and see section Product identifier % CAS -No.: 22984-54-9 2.5 — 5 CAS -No.: 13463-67-7 11 — 2.5 CAS -No.: 556-67-2 1 0.1 — 1 GHS-US classification Flam. Liq. 4, H227 Skin Irrit. 2, H315 Eye Irrit. 2A, H319 Skin Sens. 1, H317 Care. 2, H351 Flam. Liq. 3, H226 Repr. 2, H361 Aquatic Chronic 4, H413 • 4.1, Description of first aid measure_ s First -aid measures general IF exposed or concerned: Get medical advice/attention. First -aid measures after inhalation Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention if you feel unwell. First -aid measures after skin contact Wash skin with plenty of water. Take off contaminated clothing. If skin irritation or rash occurs: Get medical advice/attention. First -aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. First -aid measures after ingestion Call a poison center or a doctor if you feel unwell. 14.2. Most important symptoms and effects (acute and delayed) -- - Potential adverse human health effects and Based on available data, the classification criteria are not met. symptoms Symptoms/effects after inhalation May cause an allergic skin reaction. Symptoms/effects after skin contact May cause an allergic skin reaction. 4.3. Immediate medical attention and special treatment, if necessary__ Treat symptomatically. 09/26/2022 US -OSHA - an — 2/11 CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register / Vol. 77, No. 56 / Monday, March 26, 2012 / Rules and Regulations 5_.1._Suitabl_e (and unsuitable)_e_xtinguishing media Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide. Unsuitable extinguishing media Do not use a heavy water stream. 5.2. Specific hazards arising_from the chemical -- Hazardous decomposition products in case of fire Carbon dioxide. Carbon monoxide. fl -- '5.3. Special protective equipment and precautions for fire fi liters - - Firefighting instructions Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment. Protection during firefighting Self-contained breathing apparatus. Complete protective clothing. Do not attempt to take action without suitable protective equipment. i6.1. Personal precautions, protective equipment and emergency procedures 6.1.1. For non -emergency personnel Ventilate spillage area. Avoid contact with skin and eyes. Avoid breathing vapours. Emergency procedures 6.1.2. For emergency responders Do not attempt to take action without suitable protective equipment. For further information refer Protective equipment to section 8: "Exposure controls/personal protection". Emergency procedures Ventilate area. 6.2. Environmentaiprecautons Avoid release to the environment. 6.3 Methods and material for containment and cleaning up Mechanically recover the product. Notify authorities if product enters sewers or public waters. Methods for cleaning up Dispose of materials or solid residues at an authorized site. Other information 16,4. Referenee to_other sections For further information refer to section 13. 17.1. Precautions for safe handling, Precautions for safe handling Ensure good ventilation of the work station. Wear personal protective equipment. Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Avoid contact with skin and eyes. Avoid breathing vapours. Hygiene measures Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product. Always wash hands after handling the product. Contaminated work clothing should not be allowed out of the workplace. 7.2. Conditions for safe_ storage, including any incompatibilities Storage conditions Store in a dry place. Store locked up. Store in a well -ventilated place. Storage tible -products Strong bases. Strong acids. incomSources of ignition. Direct sunlight. Incompatible materials Storage temperature 35 —104 °F — 3/11 09126/2022 US OSHA - en CFS-S SIL SL / CFS-S SIL t Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations '8.1Control_ parameters CFS-S SIL SIL / CFS-S SIL GG No additional information available Methyltris(1-methylpropylideneaminooxy)silane (22984-54-9) No additional information available Titanium dioxide (13463-67-7) USA - ACGIH - Occupational Exposure Limits Local name ACGIH OEL TWA Remark (ACGIH) Regulatory reference USA - OSHA - Occupational Exposure Limits Local name OSHA PEL TWA [1] Regulatory reference (US -OSHA) octamethylcyclotetrasiloxane (556-67-2) No additional information available Additional information Titanium dioxide 0.2 mg/m' (Respirable fraction) 2.5 mg/m' (Respirable fraction) LRT irr; A3 ACGIH 2O22 Titanium dioxide (Total dust) 15 mg/m' OSHA Annotated Table Z-1 The product has a pasty consistency. Exposure limit values for respirable dusts are not relevant for this product. 8.2 Appropriate engineering controlsVEOW Appropriate engineering controls Ensure good ventilation of the work station. Environmental exposure controls Avoid release to the environment. 8.3 Individual protection measures/Personal protective equipment Personal protective equipment: Protective clothing. Safety glasses. Gloves. Hand protection: protective gloves. EN 374 Type Material Permeation Thickness (mm) Disposable gloves Nitrile rubber (NBR) 1 (> 10 minutes) >0.4 Eye protection: EN 166 Type I Field of application Characteristics Safety glasses Penetration 09/26/2022 US -OSHA - an 4/11 CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register I Vol. 77, No. 58 / Monday, March 26, 20121 Rules and Regulations Skin and body protection: Wear suitable protective clothing Respiratory protection: In case of inadequate ventilation wear respiratory protection. Personal protective equipment symbol(s): 016up Other information: Do not eat, drink or smoke during use. •�- 9.1. Information_ on basic physical and chem cal_propert*e Physical state Liquid Appearance Pasty. Colour red white Odour odourless Odour threshold Not determined pH 8.5 Melting point Not applicable Freezing point No data available Boiling point No data available Flash point 412 °F Relative evaporation rate (butylacetate=1) No data available Flammability (solid, gas) Not applicable. Vapour pressure No data available Relative vapour density at 20 °C No data available Relative density No data available Density 1.38 glcm' Molecular mass Not determined Solubility No data available Partition coefficient n-octanol/water (Log Pow) No data available Auto -ignition temperature No data available Decomposition temperature No data available Viscosity, kinematic No data available Viscosity, dynamic No data available Explosive limits No data available Explosive properties No data available Oxidising properties No data available 9.2.Other information VOC content < 50 g/I SECTION 10: Stability and reactivity 10.1. Reactivity The product is non -reactive under normal conditions of use, storage and transport. 5/11 09/26/2022 US -OSHA - en CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 104. Chemical stability Stable under normal conditions. 11_0.3. Possibility_ of hazardous reactions Not established. 10.4. Conditions to avoid None under recommended storage and handling conditions (see section 7). 105._Incompattble_materials Strong acids. Strong bases. e10 6. Hazardous decom osition_ roducts Under normal conditions of storage and use, hazardous decomposition products should not be produced. r1.1 Infgrmation_ort toxicolagcat Acute s- Acute toxicity (oral) Not classified Acute toxicity (dermal) Not classified Acute toxicity (inhalation) Not classified Methyltris(1-methylpropylideneaminooxy)silane (22984-54-9) LD50 dermal rat Titanium dioxide (13463-67-7) LD50 oral rat LC50 Inhalation - Rat octamethylcyclotetrasiloxane (556-67-2) LD50 oral rat LD50 dermal rat i LC50 Inhalation - Rat I. - Skin corrosionlirritation Serious eye damage/irritation Respiratory or skin sensitisation Germ cell mutagenicity 2463 m /k bodyweight g g (OECD 401: Acute Oral Toxicity, Rat, Male /female, Experimental value, Oral, 14 day(s)) > 2000 mg/kg bodyweight (OECD 402: Acute Dermal Toxicity, 24 h, Rat, Male /female, Experimental value, Dermal, 14 day(s)) > 2000 mg/kg bodyweight (OECD 401: Acute Oral Toxicity, Rat, Male / female, Experimental value, Oral, 14 day(s)) > 5.09 mg/I (OECD 403: Acute Inhalation Toxicity, 4 h, Rat, Male, Experimental value, Inhalation (dust), 14 day(s)) > 4800 mg/kg (Equivalent or similar to OECD 401, Rat, Male, Experimental value, Oral) > 2400 mg/kg bodyweight (Equivalent or similar to OECD 402, Rat, Male / female, Experimental value, Dermal) 36 mg" (OECD 403: Acute Inhalation Toxicity, 4 h, Rat, Male / female, Experimental value, Inhalation (aerosol)) Not classified pH: 8.5 Not classified pH: 8.5 May cause an allergic skin reaction. Not classified Carcinogenicity Not classified Titanium dioxide (13463-67-7) IARC group 2B - Possibly carcinogenic to humans 09/26/2022 US -OSHA - en 6/11 CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register I Vol. 77. No. 58 / Monday, March 26, 20121 Rules and Regulations Reproductive toxicity STOT-single exposure STOT-repeated exposure Aspiration hazard Viscosity, kinematic Potential adverse human health effects and symptoms Symptomsieffects after inhalation Symptoms/effects after skin contact Suspected of damaging fertility or the unborn child. Not classified Not classified Not classified No data available Based on available data, the classification criteria are not met. May cause an allergic skin reaction. May cause an allergic skin reaction. 12.1. Toxicity onsidered harmful to aquatic organisms nor to cause long-term adverse Ecology -general The product is not c effects in the environment. Ecology -water Harmful to aquatic life with long lasting effects. Methyltris(1{nethylpropylideneaminooxy)silane (22984.54-9) — 6 h O ias lati as Semi -static system, LC50- Fish [1] EC50 - Crustacea [1] ErC50 algae > 100 mgll (OECD 203: Fish, Acute Toxicity Test, 9 ryz P , Fresh water, Read -across, GLP) 201 mg/l (OECD 202: Daphnia sp. Acute Immobilisation Test, 48 h, Daphnia magna, Static system, Fresh water, Read -across, GLP) _ 16 mg/1(OECD 201: Alga, Growth Inhibition Test, 72 h, Pseudokirchneriella subcapitata, Static system, Fresh water, Experimental value, GLP) — Titanium dioxide (13463-67-7) LC50 - Fish [1] > 1000 mg/I (Pisces, Fresh water) LC50 - Other aquatic organisms [1] > 500 mg/I EC50 - Crustacea [1] > 1000 mg/l (Invertebrata, Fresh water) > 100 mg/l (OECD 201: Alga, Growth Inhibition Test, Pseudokirchneriella subcapitata, Static EC50 72h -Algae [1] system, Fresh water, Experimental value, Growth rate) — 61 mg/l (EPA 600/9-78-018, 72 h, Pseudokirchneriella subcapitata, Static system, Fresh water. ErC50 algae Experimental value, Nominal concentration) — — — 12.2. Persistence and -degradability — — — - — - CFS-S SIL SL I CFS-S SIL GG — Persistence and degradability May cause long-term adverse effects in the environment. Methyltris(1-methylpropylideneaminooxy)silane (22984-54-9) Persistence and degradability Not readily biodegradable in water. Titanium dioxide (13463-67-7) Persistence and degradability Biodegradability: not applicable. - Chemical oxygen demand (COD) Not applicable (inorganic) Thor) Not applicable (inorganic) 7/11 09/26/2022 US -OSHA - en CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations octamethylcyclotetrasiloxane (556-67-2) - — — --- Persistence and degradability Not readily biodegradable in water. 1x.3. Bioaccumulative potential CI=S� 5lL 5L 1 CFS-5 SIL GG Bioaccumulative potential Not established. Methyltris(1-methylpropylideneaminooxy)s[lane (22984-54-9) BCF - Fish [1] 0.5 — 5.8 (6 week(s), Cyprinus carpio, Flow -through system, Experimental value) Partition coefficient n-octanoVwater (Log Pow) 0.36 (Experimental value) Bioaccumulative potential Low potential for bioaccumulation (BCF < 500). Titanium dioxide (13463.67-7) ------------- Bioaccumulative potential Not bioaccumulative. octamethylcyclotetrasiloxane (556-67-2) BCF - Fish [1] 12400 1/kg (EPA OTS 797.1520, 28 day(s), Pimephales promelas, Flow -through system, Fresh water, Experimental value, GLP) Partition coefficient n-octanoVwater (Log Pow) 6.488 (Experimental value, OECD 123: Partition Coefficient (1-Octanol/Water): Slow -Stirring Method, 25.1 °C) Bioaccumulative potential High potential for bioaccumulation (BCF > 5000). 12.4 [obhty r1 sQi Methyftris(I-methylpropylideneaminooxy)silane (22984-54-9) Organic Carbon Normalized Adsorption Coefficient 5.481 (log Koc, SRC PCKOCWIN v2.0, Calculated value) (Log Koc) Ecology -soil Adsorbs into the soil. Titanium dioxide (13463-67.7) -------------------------------- Surface tension Ecology - soil octamethylcyclotetrasiloxane (556-67-2)` Organic Carbon Normalized Adsorption Coefficient (Log Koc) Ecology - soil 12.5.Other adverse effects Other information 13.1. Disposal methods Waste treatment methods 09/26/2022 US -OSHA - an No data available in the literature Low potential for mobility in soil. 4.22 (log Koc, OECD 106: Adsorption/Desorption Using a Batch Equilibrium Method, Experimental value, GLP) Low potential for mobility in soil. Avoid release to the environment. Dispose of contents/container in accordance with licensed collector's sorting instructions. 8/11 CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register I Vol. 77, No. 581 Monday, March 26, 2012 I Rules and Regulations Product/Packaging disposal recommendations Dispose in a safe manner in accordance with local/national regulations. Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation. Ecology - waste materials Avoid release to the environment. In accordance with ADR / IMDG / IATA / RID / ADR IMDG IATA RID 14.1. UN number Not applicable Not applicable Not applicable Not applicable 14.2. UN proper shipping name Not applicable Not applicable Not applicable Not applicable 14.3. Transport hazard class(es) l Not applicable Not applicable Not applicable Not applicable 14.4. Packing group — Not applicable pp Not applicable Not applicable Not applicable _ 14.5. Environmental hazards No Dangerous for theeenvironment: No Dangerous for the environment: No — — Dangerous for the environment: No Dangerous for the environment: Marine pollutant: No — — — — No supplementary information available � —_ — — — i14 6 Special_precau_tionsfor user Overland transport No data available Transport by sea No data available Air transport No data available Rail transport No data available 14.7. Transport in bulk according to Annex it of Marpol and the IBC Code Not applicable 15.1. US Federal regulations All components of this product are present and listed as Active on the United States Environmental Protection Agency Toxic Substances Control Act (TSCA) inventory Contains chemical(s) subject to TSCA 12b export notification if product is shipped outside the U.S 9111 09/26/2022 US -OSHA - an CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations octamethylcyclotetrasiloxane — CAS -No. 556-672 — p 1 _ 10�• 15.2. International regulations — Titanium dioxide (13443-67-7) - — — Listed on IARC (International Agency for Research on Cancer) — 15 3 US State re lations - California Proposition 65 This product does not contain any substances known to the state of California to cause cancer, developmental and/or reproductive harm • • • according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Revision date 09/26/2022 Data sources REGULATION (EC) No 1272/2008 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006. Other information None. Full text of H-statements H226 Flammable liquid and vapour. H227 Combustible liquid H315 Causes skin irritation. - -- H317 May cause an allergic skin reaction. H319 Causes serious eye irritation. H351 Suspected of causing cancer. H361 Suspected of damaging fertility or the unborn child. rH413 May cause long lasting harmful effects to aquatic life. NFPA health hazard 2 - Materials that, under emergency conditions, can cause temporary incapacitation or residual injury. NFPA fire hazard 1 - Materials that must be preheated before ignition can occur. NFPA reactivity 0 - Material that in themselves are normally stable, even under fire conditions. Hazard Rating Health 1 Slight Hazard - Irritation or minor reversible injury I rY possible Flammability 1 Slight Hazard - Materials that must be preheated before ignition will occur. Includes liquids, Physical solids and semi solids having a flash point above 200 F. (Class 11113) 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT Personal protection react with water, polymerize, decompose, condense, or self -react. Non -Explosives. B - Safety glasses, Gloves 69126/2 222 US -OSHA - en 10/11 CFS-S SIL SL / CFS-S SIL GG Safety Data Sheet according to Federal Register! Vol. 77, No. 58 / Monday, March 26, 20121 Rules and Regulations Indication of changes: Section I Changed item Change Comments general update SDS_US_Hilti This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product. 11/11 09126/2022 US -OSHA - en FLEXIBLE FIRESTOP SEALANT CP 606 Product description • An acrylic based firestop sealant that provides movement capability in fire rated joints and seals through -penetrations applications Product features • Silicone free • Halogen, asbestos and solvent free • Paintable • Tested up to 33% movement with 500 cycles in accordance to UL 2079 and ASTM 1966 • Smoke and fume resistant Easy clean up with water • Single component systems available Meets LEEDTm requirements for indoor environmental quality credit • 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application • Sealing construction/expansion joints • Cable bundles • Top -of -wall joints • HVAC penetrations • Metal pipes For use with • Various base materials such as masonry, concrete, gypsum, etc. • Wall and floor assemblies rated up to 3 hours • Not for use with CPVC Examples • Where a gypsum wall assembly meets the underside of a metal or concrete deck • Sealing expansion joints to impede the passage of fire, smoke and toxic fumes • Sealing around HVAC penetrations through fire -rated assemblies Installation instructions • See Hilti literature or third -party listings for complete application and installation details Technical data* Chemical basis Color Density Application temperature Storage tem erature Temperature resistance Shelf life Tack free time _Skin -forming time Curin-q time Average volume shrinkage (kSTM C1241) Movement capability Mold & mildew Electrical resistance LEED Compliant LEED VOC Intumescent Seismic resistant Water ti htness Tem t Water -based acr lic dis ersion Available in red white and gray 99.9 lb t3 35°F to 104°F 1.5°C to 40°C 35'F to 95°F (1.5•C to 35°C1 -22°F to 1761F -301C to 80°C 24 months 23mins ventilated at 77•17, 80% rel. humidity) Approx. 15 min App rox. 3 min 3 Jays 22% Up to 33% Class 0 1ASTM G21-96 Yes Yes CDPH v1.2-2017 49 NO Pairs ure resistance Surface burning characteristics -221Fto 176°F -30°C to 80°C ASTM E 84-96 Flame Spread: 10 Smoke Development: 0 Surface burning characteristics Flame Spread: 14 CA ULC-S102 Smoke Developed: 4 California State Fire Marshall Approvals _ Yes ens & joints) Cily of New York 2eproval Yes CP606 MEA 100-99-MV Air leakage (UL 2079 L-Rating) L-Rating at Ambient = Less than 1 CFM / Lin Ft. Sound transmission classification L-Ratingat 400%F = Less than 1 CFM Lin Ft. 68 ASTM E 90-99 Relates to Specific constructio Tested in accordance with UL 2079, ASTM E 814, ASTM E 1966, ASTM E 2837, `At 73°F (23°C) and 50°6 relative humidity UL 1479. ASTM C920 ASTM C1241 CANLC-S115 Hilti Firestop ■ Saving lives through innovation ► and education Product information FILL, VOID OR CAVITY MATERIAL �pSllffj� FOR USE IN THROUGH -PENETRATION FIRESTOP SYSTEMS AND C UL us JOINT SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FM APPROVED D Tube V Im CFS-S ACR; CP 606 Safety Data Sheet according to Federal Register! Vol. Revis on date 04125/2022�h 26 Supersedes: 11 30/2012012 1 Rules and 7 ions Version: 4.6 Issue date: 04/2512022 1.1. Identification Product form Mixture CFS-S ACR; CP 606 Trade name BU Fire Protection Product code 1.2. Reco_tnmended use and restrictlans on use Use of the substance/mixture Flexible firestop sealant Recommended use Adhesives, sealants Supplier Department issuing data specification sheet Supplier HIM AG Hilti, Inc. Legacy Tower, Suite 1000 FeldkircherstraBe 100 Schaan, 9494 - Liechtenstein 7250 Dallas Parkway T +423 234 2111 Plano, TX 75024 -USA hilti.com T +1 9724035800 _hemicals.hse 1-800-879-8000 toll free - F +1 918 254 0522 A. Emergency telephone number Emergency number Chem-Trec Tel.: 1 800 424 9300 (USA, PR, Virgin Islands, Canada) Tel.: 703 527 3887 (Other countries) +1 918 8723000 1-800-879-8000 toll free 2.1. Classification of the substance or mixture GHS-US classification Not classified GHS Label_elements, including precautionary statements GHS US labelling No labelling applicable 2s, Other hazards which do not result in classification No additional information available 2.4. Unknown acute toxicity (GHS US) Not applicable 3.1. Substances Not applicable Page 1 04/25/2022 US -OSHA - en according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 3.2. Mixtures This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of HazCom 2012 • 4.1. Description of first aid measures First -aid measures general Never give anything by mouth to an unconscious person. If you feel unwell, seek medical advice (show the label where possible). First -aid measures after inhalation Get medical advice/attention if you feel unwell. Allow affected person to breathe fresh air. Allow the victim to rest. First4d measures after skin contact Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention. Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse. First -aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists. First -aid measures after ingestion Get medical advice/attention if you feel unwell. Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention. 4.2. Most important symptoms_ and_eff_e_Gts (acute and delayed) Potential adverse human health effects and Based on available data, the classification criteria are not met. symptoms Symptoms/effects Not expected to present a significant hazard under anticipated conditions of normal use. Al. immediate medical attention and$pedal treatment, if necessary No additional information available irelk'a.loar M. ■ ■ Al. Suitable (arrsi unsujtablej extinguishing me_ a Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide. Sand. Unsuitable extinguishing media Do not use a heavy water stream. 5.2. Specific hazards arising from the chemical - -- - -. Hazardous decomposition products in case of Carbon dioxide. Carbon monoxide. fire 53. Special protective equrpment_and precautions for fie -fighters Firefighting instructions Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment. Protection during firefighting Self-contained breathing apparatus. Complete protective clothing. Do not enter fire area without proper protective equipment, including respiratory protection. • • • 6.1. Personal precautions, protective equipment and emergency procedures 6.1.1. For non -emergency personnel Emergency procedures Evacuate unnecessar y personnel. 04/25/2022 US -OSHA - an 2/8 CFS-S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 6.1.2. For emergency responders Protective equipment For further information refer to section 8: "Exposure controls/personal protection". Equip cleanup crew with proper protection. Emergency procedures Ventilate area. 4.2. Environmental precautions Prevent entry to sewers and public waters. Notify authorities if liquid enters sewers or public waters. r-- 6.3. Methods and material for containment and -cleaning up Methods for cleaning up Mechanically recover the product. On land, sweep or shovel into suitable containers. Minimise generation of dust. Store away from other materials. lcc Reference to other sections For further information refer to section 13. See Section 8. Exposure controls and personal protection. • . • • .•� 7.1. Precautions for safe handling t___ __ _ Precautions for safe handling Wear personal protective equipment. Wash hands and other exposed areas with mildsoap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour. Hygiene measures Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product. Always wash hands after handling the product. 7.2, Conditions for safe storage, including any ipComPAt141rties Storage conditions Store in a dry place. Keep container closed when not in use. Incompatible products Strong bases. Strong acids. Incompatible materials Sources of ignition. Direct sunlight. Storage temperature 35 — 95 "F SECTION 8: Exposure controls/personal protection control parameters CFSS ACR; CP 606 No additional information available Additional information The product has a pasty consistency. Exposure limit values for respirable dusts are not relevant for this product. 8.2. Appropriate_ engineering_controls No additional information available 8.3. Individual protection measures/Personal protective equipment Personal protective equipment: Protective clothing. Safety glasses. Gloves. Avoid all unnecessary exposure. Hand protection: Protective gloves. EN 374. Wear protective gloves. Type TL_�Permeationerial Disposable gloves Nitrile rubber (NER) (> 10 minutes) Eye protection: Chemical goggles or safety glasses 04125/2022 US -OSHA - an Thickness (mm) Penetration >0.4 318 CFS-S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Type Field of application Characteristics Safety glasses Skin and body protection: Wear suitable protective clothing Personal protective equipment symbol(s): 1� Other information: Do not eat, drink or smoke during use. 9.1_ Information on basic physical and -chemical properties -- — - Physical state Solid -- Appearance Pasty. Colour red white Grey Odour characteristic Odour threshold Not determined pH = 9 Not applicable Melting point Not applicable Freezing point No data available Boiling point No data available Flash point Not applicable Relative evaporation rate (butylacetate=l) No data available Flammability (solid, gas) Not applicable. Non flammable. Vapour pressure No data available Relative vapour density at 20 °C No data available Relative density No data available Density 1.6 g/cm' Molecular mass Not determined Solubility No data available Partition coefficient n-octanoVwater (Log Pow) No data available Auto -ignition temperature No data available Decomposition temperature No data available Viscosity, kinematic No data available Viscosity, dynamic No data available Explosive limits No data available Explosive properties No data available Oxidising properties No data available 9.2. Other infor - --- mation --- No additional information available • 1 • • 10.1. Reactivity The product is non -reactive under normal conditions of use, storage and transport. 04/25/2022 — -- — US -OSHA - an 4/8 CFS-S ACR; CP 606 Safety Data Sheet according to Federal Register 1 Vol. 77, No. 581 Monday, March 26, 20121 Rules and Regulations 16.2. Chemical stability Stable under normal conditions. Not established. 10.. Possibility of hazardous reactions No dangerous reactions known under normal conditions of use. Not established. 10.4. Conditions to avoid None under recommended storage and handling conditions (see section 7). Direct sunlight. Extremely high or low temperatures. 110.5. Incompatible materials Strong acids. Strong bases. 10.6. Hazardous decomposition products Under normal conditions of storage and use, hazardous decomposition products should not be produced. fume. Carbon monoxide. Carbon dioxide. f11.1. Information on toxicological_ effects Acute toxicity (oral) Not classified Acute toxicity (dermal) Not classified Acute toxicity (inhalation) Not classified Skin corrosion/irritation Not classified pH: # 9 Not applicable Serious eye damage/irritation Not classified pH: ft 9 Not applicable Respiratory or skin sensitisation Not classified Germ cell mutagenicity Not classified Carcinogenicity Not classified Reproductive toxicity Not classified STOTsingle exposure Not classified STOT-repeated exposure Not classified Aspiration hazard Not classified Viscosity, kinematic Potential adverse human health effects and Based on available data, the classification criteria are not met. symptoms Symptoms/effects Not expected to present a significant hazard under anticipated conditions of normal use. 12A.- Toxicity Ecology - general 1.2_.2. Persistence and degradability ECFS-!S A�and 06enegradability 12.3. Bioaccumulative potential CFSS ACR; CP 606 Bioaccumulative potential 04/2512022 The product is not considered harmful to aquatic organisms nor to cause long-term adverse effects in the environment. Not established. — — - — — - — — Not established. US -OSHA - en — — — — — — — 518 CFS-S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ' 12.4. Mobi -i in soil — — -- - - t_-- -i No additional information available 12.5 Other adverse effects Other information Avoid release to the environment. 1$,1, Disposalmetho__d_s Waste treatment methods Dispose in a safe manner in accordance with IocaUnational regulations. Product/Packaging disposal recommendations Recycle the material as far as possible. Additional information European waste catalogue: 08 0410 waste adhesives and sealants other than those mentioned in 08 04 09. SECTION 14: Transport information y.v. apectau precaugo_ns _t_or user Overland transport Not regulated Transport by sea Not regulated Air transport Not regulated Rail transport Not regulated 14.7. Maritime transport in bulk according to IMO_ instruments Not applicable 04/25/2022 US -OSHA - en 6/8 CFS-S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 581 Monday, March 26, 20121 Rules and Regulations 15.1. US Federal regulations All components of this product are present and listed as Active on the United States Environmental Protection Agency Toxic Substances Control Act (TSCA) inventory 15.2. International regulations CANADA No additional information available EU-Regulations No additional information available National regulations �CFSS ACR;CP 606 components of this product are present and listed as Active on the United States Environmental Protection Agency Toxic Substances ntrol Act (TSCA) inventory �15.3.US State regulations_ California Proposition 65 - This product does not contain any substances known to the state of California to cause cancer, developmental and/or reproductive harm according to Federal Register! Vol. 77 No. 581 Monday, March 26, 2012 / Rules and Regulations Revision date Data sources Other information 04/25/2022 Supplier information. EU: REACH. K-REACH. REGULATION (EC) No 1272/2008 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006. None. NFPA health hazard 0 - Materials that, under emergency conditions, would offer no hazard beyond that of ordinary combustible materials. NFPA fire hazard 0 - Materials that will not bum under typical fire conditions, including intrinsically noncombustible materials such as concrete, stone, and sand. NFPA reactivity 0 - Material that in themselves are normally stable, even under fire conditions. Hazard Rating Health 0 Minimal Hazard - No significant risk to health Flammability 0 Minimal Hazard - Materials that will not bum Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT react with water, polymerize, decompose, condense, or self -react. Non -Explosives. Personal protection B B - Safety glasses, Gloves Indication of changes: Comments —I Section Changed item Change — general update SDS_US_Hilti 7/8 04/2512022 US -OSHA - an CFS-S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product. 04/25/2022 US -OSHA - an 8/8 Product Information Firestop Wrap Strip (CP 648-S) Product description A single wrap strip of intumescent, flexible firestop for use with plastic and insulated pipe penetrations Product features a Highly intumescent ■ Pre -measured — no cutting required ■ Integrated fastening tape Cost effective Quick and easy closure without tools Ideal for very tight installations Areas of application Firestopping combustible pipe penetrations Difficult applications where space is limited Penetrations through concrete over metal deck Suitable for the following plastic pipe materials: PVC, CPVC, ABS, FRPP For use with Concrete, masonry, wood floor and gypsum wall assemblies Wall and floor assemblies rated up to 3 hours Examples Waste water pipes Fresh water pipes Decking penetrations Installation instructions for CP 648-S Notice Before handling, read Material Safety Data Sheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or HIM Firestop Systems Guide for complete installation information Installation 1. Clean the plastic or insulated pipe penetration. Expansion of the intumescent material during a fire closes the plastic pipe. Very dirty pipes (ie: with remains of mortar) may lead to a delay in the closing action. Soiled plastic or insulated pipes should, therefore, be cleaned in the area where the CP 648-S Firestop Wrap Strip is to be installed. 2. Install Wrap Strip. First check the annular space to ensure compatibility with the appropriate UL System. Use the CP 648-S Firestop Wrap Strip corresponding to the diameter of the pipe to be installed. Wrap the CP 648-S strip around the pipe and fasten it tightly using the integrated adhesive strip. Push the CP 648-S Firestop Wrap Strip into the annular space in accordance with the UL listing. Technical Data* I CP 648-S Density Dimension (approximate) (thkns" x width" x length") Color Temperature resistance Intumescent activation x. 1.35 g/Cm` 1.5": 3/16" x 1 " x 6-3/4" 2": 3/16" x 1" x 8-1/4" 3": 3/16" x 1-3/4" x 11-1/2" 4": 3/8" x 1-3/4" x 15" 6": 1/2" x 1-3/4" x 22-1/4" Black with foil backing -40"F to 212"F (-40"C to 1 Expansion ratio (unrestricted) Tested in accordance with • UL 1479 • ASTM E 814 • ASTM G21 320"F 1:40 -At 73-F (23oC) and 50% relative humidity G�,garp�FO FOR SEOID OR CAVITY IN THROUGH -PENETRATION TERIAI_�� Q FIRESTOP SYSTEMS ramn momvo�A APPROVED vian meava1-trmveft-fom. CSEE UL FIRE RESISTANCE DIRECTORY rec*^iaeo-sa•n�a�aa 66Y7 Me Wbrlml �prporeli"n. 3. Seal against smoke and gas. Seal the remaining gap Storage • Store only in the original packaging in a location with Hilti FS-ONE sealant. temperatures between 4. For maintenance reasons, a penetration seal can be protected from moisture at permanently marked with an identification plate and 231F and 86oF (-5oC and 30oC). fastened in a visible position next to the seal. Not for use • In highly corrosive surroundings • Outdoors I t. Clean penetration 2A. Wrap the CP 648S 2B. Push the CP 648-S smoeal penetration ke with FFS-ONE 4. (ifrequired)installation plate Wrap Strip around Wrap Strip along the pipe the pipe and fasten It and Into the above. bider space sealant. tightly with the adhesive strip. Hilt! Firestop Saving lives through innovation and education Hilti.Out erform.Outlast. Hilt!, Inc. (U.S.) 1-8o0-87 m800 • www.us.h!Ri.com • en espanol 1-800-879-5000 • Hilt! Firestop Systems Guide Material Information Statement Articles According to Regulation (EC) 1907/2006, Article 32 Revision: 12.09.2023 1 Identification of the articles and of the company undertaking Trade name: • Bottom track seal CFS-BTS • CFP-ES ENDOSHIELD • Firestop Bandage CFS-B / CFS-CB / CP 646 • Firestop Back Pan Strip CFS-BPS • Firestop Block CFS-BL / CFS-BL P • Firestop Board CP 675 • Firestop Boot CFS-BO • Firestop Box Insert • Firestop Cable Collar CFS-CC / CFS-RCC / CFS-RCC EXT • Firestop Cable Module CFS-T • Firestop Cast4n device and accessories CP 680 / CP 681 / CFS-CID / CFS-CID MD P/M/ CFS-CID MD HS GUI / CFS- CID MD PLT W21W3 / CFS-CID MD HS / CFS-CID ARB TE- Y / CFS-CID ARB TE-C / CFS-CID U • Firestop Coated Board CFS-CT B / CFS-CT HDB / CP670 / CP673 / CP676 • Firestop Collar CFS-C / CFS-C P • Firestop Collar CP 643 / CP 644 • Firestop Composite Sheet CFS-COS • Firestop Cord CFS-CO • Firestop Cushion CP 651N • Firestop Drop -In Device CFS-DID • Firestop Edge of Slab QuickSeal CFS-EOS QS • Firestop Endless Collar CFS-C EL • Firestop Filler Module CFS-T FB • Firestop Flex Seal CFS-FS • Firestop Gangplate CFS-SL GP • Firestop Module Box CFS-MB / CP 657 1 J Application of the listed articles Version: 27 • Firestop Plug CFS-PL / CP 658 • Firestop Plug Seal CFS-T RR / CFS-T RRS • Firestop Retrofit Sleeve CFSSL RK • Firestop Sleeve CP 645 • Firestop Sleeve Kit CFS-SL SK • Firestop Modular Sleeves and accessories CFS-MSL / CFS- MSL GPP Pre -Installed Gang Plates / CFS-MSL FGR Floor Grids / CFS-MSL GCL (Ganging Clips) / CFS-MSL GPA Adjustable Gang Plates / CFS-MSL GPR Retrofit Gang Plates • Firestop Speed Sleeve CFS-SL / CFS-SL GA / CP 653 • Firestop Top Track Seal CFS-TTS • Firestop Top Track Seal CFS-TTS MD • Firestop Top Track Cover CFS-TTS MD C • Firestop Top Track Plug CFS-TTS MD P • Firestop Top Track Seal CFS-TTS 212 • Firestop Top Track Seal CFS-TTS R • Firestop Wedge Seal CFS-T WD120 • Firestop Wrap Strip CFS-W EL / SG / P / CP 648 • Foil Tapes CS -FT • Intumescent fagade cavity closer CP674 • Joint Sealing Tapes CS-JST • Mineral Wool • Mineral Wool Boards • Multifunctional Tapes CS-MFT • Pre -coated Mineral Wool Boards • Smoke & Acoustic Track Seal CS-TTS SA • Speed Plug CP 777 • Speed Strip CP 767 Construction industry. Refer to Hilti product literature, technical data sheets, 3rd party published listings and national approvals for speck application information. For more details, please contact your local HIM organization through hffp://www.hilti.group - - _ 1 3 Manufacturer / Supplier Hilt! AG Feldkircherstr. 100 FL-9494 Schaan Liechtenstein Customer Service Phone +423 (0)844 84 84 85 Fax +423 (0)844 84 84 86 A Safety Data Sheet is not required due to the classification of these products as "articles" according to Regulation (EC) No. 1907/2006 of 18 December 2006 (EU) / 29CFR 1910.1200 (U.S.A.). Consequently, these products are exempted from CLIP / OSHA Labeling and SDS requirements. These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. Informing department: chemicals.hse whilti.com Product information HIGH-PERFORMANCE INTUMESCENT FIRESTOP SEALANT FS-ONE MAX Product description • Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non-combustible penetrations for up to 4 hours fire rating Applications for use • For effectively sealing most common through penetrations in a variety of base materials • For use on concrete, masonry and drywall Mixed and multiple penetrations • Metal pipe penetrations: copper, steel and EMT • Insulated metal pipe penetrations: steel and copper • Plastic pipe penetrations: closed or vented Advantages • One product for a variety of common through penetrations • Cost-effective, easy -to -use solution • Water -based and paintable • Industry -leading VOC results - Ethylene glycol -free installation instructions - See Hilti literature or third -party listings for complete application and installation details Technical Data* Chemical basis Water -based acrylic dispersion Approx. Density 84.3 Ib/ft' Color Red — Approx. cure time'l 2mm / 3 days Application temperature range" 35°F to 104° (1.5C to 40°C) Temperature resistance range -4°F to 212°F (-20°C to 100°C) _ Storage Temperature 35°F to 77F (1.5°C to 25°C) _ 20mins (@ 73°F / 50% rel. humidity) Tack free time Shelf life 18 months Temperature resistance range -4°F to 212°F Mold and mildew performance Class 0 (ASTM G21-13) Mold and mildew resistant Yes Expansion ratio (unrestricted, up to) 1:5 Paintable Yes Chemical resistance Yes Electrical resistance Yes FBC compatible (Lubrizol) Yes Intumescent Yes W-rating Yes M-rated Yes LEED VOC (input) 9 g/L LEED V4 Compliant Yes (CDPH vl.2-2017) STC rating (ASTM E90) 62 (relates to specific construction) Movement d 7.5°/a Surface burning characteristics Flame Spread: 0 Smoke Development: 10 (ASTM E 84-14) ZSFM ll08 for FS-ONE MAX California State Fire Marshal approval Ient F restop Sealant Tested in accordance with ASTM G21, ASTM E 90, CAN/ULC-5115, UL 1479, ASTM E 814, ASTM E84 Hilt! Firestop Saving lives ■ through innovation and education Order Information Item DeHi City per package number FSirestop sealant 3530249 10oS-ONE MAX (1 c oz cartridge FS-Oirestop sealant 3530250 20oz foil FS-ONE MAX (1 case) 20 oz foil FS-ONE MAX 1x Firestop sealant 2101531 10 oz FS-ONE MAX cartridge 10 oz cartridge FS-ONE MAX 1x Firestop sealant 2101533 5 gallon pail FS-ONE MAX 5 gallon pail CAVITY FILL, VOID OR=DIRFCTORY resly Fo FOR USE IN THR FIREST C • lib SEE UL FIRE RE eUS SYSTEM COMPATIBLE APPROVED visa sHxyuemc°mpaaroie.wm FBC- is a tredemerk It Intertek ,°a Wbrlml corporation. rated Chemical Mold and mildew •+���••�° resistant resistant Volume par unit: • Caulk tube = 10.5 It. oz (16.9inal • Foil - 600ml (36.4in') • Pail Sgal (1,155inc) 1) At 75°F (24°C) and 50% relative humidity 2) For ambient and surface temperatures between 10°F (-12°C) and 35°F (1.5°C), the following conditions must apply: • Substrate surfaces are clean and dry (e.g. free of dust, rust, grease, oil, dew, frost, ice, moisture, etc); • Product maintained above 50'F (101C) for a minimum of 24 hours prior to application; • Product will not cure at ambient temperatures below 32°F / 0°C © © Tuhe 0 FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Revision date: 10/30/2024 Issue date: 10/30/2024 Supersedes: 11/3/2022 Version: 1.7 1.1, Identificaf_on_ Product form Trade name Product code Mixture FS-ONE MAX / CFS-FIL BU Fire Protection 1.2 Recommended lase and restrictions on use Use of the substance/mixture Firestop intumescent sealant Recommended use Adhesives, sealants 1_.3._Supplier Supplier Hilti, Inc. Legacy Tower, Suite 1000 7250 Dallas Parkway US TX 75024 Plano USA T +1 9724035800 1-800-879-8000 toll free, F +1 918 254 0522 us -sales hilti.com '1.4 Emergency telephone number Emergency number 2.1, Classification of the substance or mixture GHS-US classification Not classed Department issuing data specification sheet Hilti AG FeldkircherstraBe 100 FL 9494 Schaan Liechtenstein T +423 234 2111 roduct.comoliance-fire a rotectio�hilti Emergency CONTACT (24-Hour-Number) GBK/Infotrac ID 101022 (USA domestic) 1 800 535 5053 or international (001) 352 323 3500 '2.2. GHS Label elements, including precautionary state_ m_ e_nts GHS US labelling No labelling applicable 2.3.Other hazards which do not result in classification No additional information available 2.4. Unknown acute toxicity (GHS US) Not applicable 1013012024 US -OSHA - an Page 1 FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register 1 Vol. 77, No. 581 Monday, March 26, 20121 Rules and Regulations 3.1. Substances Not applicable 3.2._Mixtures Product identifier % HS-US classification Name Quartz (Si02) CAS -No.: 14808-60-7 2.5 — 5 Carc. 1 A, H350 STOT RE 1, H372 text of hazard classes and H-statements : see section 16 L4.1. Description of first aid measures First -aid measures general Never give anything by mouth to an unconscious person. If you feel unwell, seek medical advice (show the label where possible). First -aid measures after inhalation Get medical advicelattention if you feel unwell. Allow affected person to breathe fresh air. Allow the victim to rest. First -aid measures after skin contact Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention. Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse. First -aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists. First -aid measures after ingestion Get medical advicelattention if you feel unwell. Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention. �- - - i4.2. Most important symptoms and effects acute and delayed), Potential adverse human health effects and Based on available data, the classification criteria are not met. symptoms Not expected to present a significant hazard under anticipated conditions of normal use. Symptoms/effects A Immediate medic_a_I_atten_a tionnd special treatment, if necessary No additional information available .1. S,uitable-(and unsuitable) extinguishing media - Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide. Sand. Do not use a heavy water stream. Unsuitable extinguishing media 15.2. Specific hazards arising from the chemical Hazardous decomposition products in case of fire Carbon dioxide. Carbon monoxide. 5.3. Special protective equipment and precautions for fire-fighters Firefighting instructions Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment. Protection during firefighting Self-contained breathing apparatus. Complete protective clothing. Do not enter fire area without proper protective equipment, including respiratory protection. 2/10 10/3012024 T US -OSHA - en FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 6 1. Personal precaut OR" tective equipment and emergency procedures 6.1.1. For non -emergency personnel Emergency procedures Evacuate unnecessar y personnel. 6.1.2. For emergency responders Protective equipment For further information refer to section 8: "Exposure controls/personal protection". Equip cleanup Emergency crew with proper protection. g y procedures Ventilate area. 6.2 Environmental precautions Prevent entry to sewers and public waters. Notify authorities if liquid enters sewers or public waters. ,3. Methods and ma#erial for containment and cleaning_up Methods for cleaning up Mechanically recover the product. On land, sweep or shovel into suitable containers. Minimise generation of dust. Store away from other materials. 6A Reference -to ether sections For further information refer to section 13. See Section 8. Exposure controls and personal protection. 7.1,E Precautions for safe ha0dlir Precautions for safe handling Wear personal protective equipment. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in Hygiene measures process area to prevent formation of vapour. Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product. Always wash hands after handling the product. ;7.2 Conditions for safe storage, including any incompatibilities Conditions conditions Keep cool. Store in a dr y place. Keep only in the original container in a cool, well ventilated place away from: Keep container closed when not in use. Incompatible products Strong bases. Strong acids. Incompatible materials Sources of ignition. Direct sunlight. Storage temperature 41 — 77 "F 8.1, Control Parameters pFS-ONE MAX / CFS-FIL No additional information available Quartz (S1102) (14808-60-7) USA -ACGIH - Occupational Exposure Limits Local name ACGIH OEL TWA Remark (ACGIH) Regulatory reference Silica crystaline - quartz 0.025 mg/ma (R - Respirable particulate matter) TLV® Basis: Pulm fibrosis; lung cancer. Notations: A2 (Suspected Human Carcinogen) ACGIH 2O23 10/3012024 US -OSHA - an 3/10 FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register I Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Quartz (Si02) (14808-60-7) USA - OSHA - Occupational Exposure Limits Local name Silica, crystalline quartz, respirable dust Remark (OSHA) (3) See Table Z-3. Regulatory reference (US -OSHA) OSHA Annotated Table Z-3 Mineral Dusts Additional information The product has a pasty consistency. Exposure limit values for respirable dusts are not relevant for this product. 8.2 _Appropriate engineering controls No additional information available 8.3. Individualprotecton measures/Personal protective_egupmertt Personal protective equipment: Protective clothing. Safety glasses. Gloves. Avoid all unnecessary exposure. Hand protection: Wear suitable gloves tested to EN374. Suitable for short-term work or as a splash guard: Nitrile rubber gloves (> 0.1 mm). In case of permanent product contact: Type Material Permeation Thickness (mm) Penetration Disposable gloves Nitrile rubber (NBR) 8 (> 480 minutes) >0A Eye protection: Chemical goggles or safety glasses Skin and body protection: Wear suitable protective clothing Respiratory protection: No respiratory protection needed under normal use conditions Personal protective equipment symbol($): 00'up Other information: Do not eat, drink or smoke during use. 9.1. Information on basic physical and chemical properties Physical state Solid Appearance Pasty. Colour red characteristic Odour Not determined Odour threshold = 7.85 pH Not applicable Melting point 10/3012024 US -OSHA - en 4110 FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Freezing point No data available Boiling point No data available Flash point Not applicable Relative evaporation rate (butylacetate=1) No data available Flammability (solid, gas) Not applicable. Non flammable. Vapour pressure No data available Relative vapour density at 20°C No data available Relative density No data available Density = 1.35 g/cm3 Molecular mass Not determined Solubility No data available Partition coefficient n-octanoUwater (Log Pow) No data available Auto -ignition temperature No data available Decomposition temperature No data available Viscosity, kinematic No data available Viscosity, dynamic No data available Explosive limits No data available Explosive properties No data available Oxidising properties No data available .2 Other infomlaton VOC content y gA 1 , The product is non -reactive under normal conditions of use, storage and transport. I .Z-chemical stability_ Stable under normal conditions. Not established. �10.3. Possibility of hazardous reactions No dangerous reactions known under normal conditions of use. Not established. ow 10.4 Conditions to avoid None under recommended storage and handling conditions (see section 7). Direct sunlight. Extremely high or tow temperatures. 10,5. Incompatible _materials Strong acids. Strong bases. 10.6 Hazardous decomposition products Under normal conditions of storage and use, hazardous decomposition products should not be produced. fume. Carbon monoxide. Carbon dioxide. SECTION 11: Toxicological information •� ica effects Acute toxicity (oral) Not classified Acute toxicity (dermal) Not classified Acute toxicity (inhalation) Not classified Skin corrosion/irritation Not classified PH: = 7.85 Serious eye damage/irritation Not classed PH: - 7.85 Respiratory or skin sensitisation Not classed 10/30/2024 US -OSHA --en 5/10 FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register! Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Germ cell mutagenicity Not classified Carcinogenicity Not classified Quartz (Si02) (14808-60-7) IARC group 1 - Carcinogenic to humans National Toxicology Program (NTP) Status Known Human Carcinogens Reproductive toxicity Not classified STOT-single exposure Not classified STOT-repeated exposure Not classified Quartz (Si02) (14808-60-7) Causes damage to organs through prolonged or repeated exposure. — STOT-repeated exposure I — Aspiration hazard Not classified Viscosity, kinematic Potential adverse human health effects and No data available Based on available data, the classification criteria are not met. symptoms Not expected to present a significant hazard under anticipated conditions of normal use. Symptoms/effects 12.1. Toxicity Ecology -general The product is not considered harmful to aquatic organisms nor to cause long-term adverse effects in the environment. 12,2. Persistence and degradabilityEFS-ONEMAX ! CFS=FIL e and degradability Not established. (SI02) (14808.60-7) ly degradablence and degradabilityBiodegradability: r not applicable. l oxygen demand (COD) Not applicable (inorganic) Not applicable (inorganic) 12A Bloaccumulatir+e potential FS-ONE MAX! CFS-FIL Bioaccumulative potential Not established. Quartz (Si02) (14808.60.7) Bioaccumulative potential No bioaccumulation data available. 12.4. Mobility in soil Quartz (S102) (14808-60-7) No data available in the literature Surface tension Low potential for mobility in soil. Ecology - soil 6/10 10/30/2024 US -OSHA- en FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 12.5. Other adverse effects Other information Avoid release to the environment. DN 13: Disposal consideratin 13 1, Pis posal me(kods Waste treatment methods Dispose in a safe manner in accordance with local/national regulations. Product/Packaging disposal recommendations Dispose in a safe manner in accordance with local/national regulations. Ecological information Avoid release to the environment. In accordance with DOT / TDG / IMDG / IATA • DOT TDG �— IMDG IATA 14.1. UN number Not regulated for transport 14.2. Proper Shipping Name Not applicable Not applicable 14.3. Transport hazard class(es) Not applicable Not applicable 14.4. Packing group Not applicable Not applicable 114.5. Environmental hazards Dangerous for the environment: No i Dangerous for the environment: No No supplementary information available ' 74.6. Specialprec jut' Qns for user DOT No data available TDG No data available IMDG No data available Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Dangerous for the environment: No i Dangerous for the environment: No Marine pollutant: No IATA No data available 141. Transport in bulk according to Annex II of MARPOL and the IBC Code Not applicable 10/30/2024 US -OSHA - an 7/10 FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 581 Monday, March 26, 2012 / Rules and Regulations 15.1 US Federal_ regulations, F(TSCA)Pionventory comnents of this product are present and listed as Active on the United States Environmental Protection Agency Toxic Substances Control Act - 115.2. international regulations_ Quartz (Si02) (14808-60-7) — — — Listed on IARC (International Agency for Research on Cancer) Listed as carcinogen on NTP (National Toxicology Program) Listed on Thailand Existing Chemicals Inventory (DIW) 15.3._US State regulations_ California Proposition 65 - This product does not contain any substances known to the state of California to cause cancer, developmental and/or reproductive harm according to Federal Register / Vol. 77, No. 58 I Monday, March 26, 20121 Rules and Regulations Revision date 10/30/2024 Data sources REGULATION (EC) No 127212008 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999145/EC, and amending Regulation (EC) No 190712006. Other information None. Full text of H-statements H350 May cause cancer.— H372 Causes damage to organs through prolonged or repeated exposure. — L ons and acronyms Chemical Abstract Service number European Agreement concerning the International Carriage of Dangerous Goods by Inland Waterways ADR European Agreement concerning the International Carriage of Dangerous Goods by Road ATE Acute Toxicity Estimate BCF Bioconcentration factor BLV Biological limit value BOD Biochemical oxygen demand (BOD) CLP Classification Labelling Packaging Regulation; Regulation (EC) No 1272/2008 DMEL Derived Minimal Effect level DNEL Derived -No Effect Level EC -No. European Community number EC50 Median effective concentration 8110 10130/2024 US -OSHA - an FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations woureviaiions and acronyms ED Endocrine disrupting properties EIAR European Standard C International Agency for Research on Cancer IATA International Air Transport Association IMDG International Maritime Dangerous Goods IOELV Indicative Occupational Exposure Limit Value LC50 Median lethal concentration LD50 Median lethal dose LOAEL Lowest Observed Adverse Effect Level N.O.S. Not Otherwise Specified NOAEC No -Observed Adverse Effect Concentration NOAEL No -Observed Adverse Effect Level NOEC No -Observed Effect Concentration vPvB Very Persistent and Very Bioaccumulative WGK Water Hazard Class VOC Volatile Organic Compounds SDS Safety Data Sheet RID Regulations concerning the International Carriage of Dangerous Goods by Rail REACH Registration, Evaluation, Authorisation and Restriction of Chemicals Regulation (EC) No 1907/2006 PNEC Predicted No -Effect Concentration PBT Persistent Bioaccumulative Toxic OEL Occupational Exposure Limit OECD Organisation for Economic Co-operation and Development COD Chemical oxygen demand (COD) ThOD Theoretical oxygen demand (ThOD) TRGS Technical Rules for Hazardous Substances TLM Median Tolerance Limit STP Sewage treatment plant NFPA health hazard 0 - Materials that, under emergency conditions, would offer no hazard beyond that of ordinary combustible materials. NFPA fire hazard 1 - Materials that must be preheated before ignition can occur. NFPA reactivity 0 - Material that in themselves are normally stable, even under fire conditions. 10/30/2024 US -OSHA - en 9/10 FS-ONE MAX / CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 581 Monday, March 26, 2012 / Rules and Regulations Hazard Rating Health 0 Minimal Hazard - No significant risk to health Flammability 0 Minimal Hazard - Materials that will not bum Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT react with water, polymerize, decompose, condense, or self -react. Non -Explosives. Personal protection B - Safety glasses, Gloves Indication of changes: Section Changed item Change Comments general update SDS_US_Hilti This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental requirements only It should not therefore be construed as guaranteeing any specific property of the product. 10/10 10130/2024 US -OSHA - an ". _ r ti l j THERMAHBER a SAFING MINERAL WOOL INSULATION Features • Exceptional performance in Perimeter Fire Containment Systems as tested in full-scale ASTM E2307 systems • Provides fire containment in rated assemblies • Fire-resistant to temperatures above 2,000'F (1,093'C) Helps conserve energy, reduce greenhouse gas emissions • Mold -resistant • Enhances acoustical performance • Minimum 70% recycled content' • Contributes to credits in several green building programs, such as LEED® and Green Globes® Physical Properties PROPERTY TEST METHOD VALUE Corrosion of Steel, Aluminum, and ASTM C665 Noncorrosive, Types I, II _Copper Non -Combustibility ASTM E136 Non -Combustible Non -Combustibility CAN/ULC S114 Complies Water Vapor ASTM E96 Unfaced, 50 perms as tested Permeance Foil -Faced, 0.02 perms as tested Water Vapor Sorption ASTM C1104 sorption less than 1 i" volume Surface Burning ASTM E84 Unfaced, Flame Spread 0, Smoke Developed 0 Characteristics Foil -Faced, Flame Spread 25, Smoke Developed 0 Surface Burning CAN/ULC S102 Unfaced, Flame Spread 0, Smoke Developed 0 Characteristics Foil -Faced, Flame Spread 25, Smoke Developed 0 Thermafiber® Safing insulation used in conjunc- Perimeter Fire tion with Thermafiber® FireSpan® insulations in Containment Systems ASTM E2307 the Perimeter Fire Containment System Complies Thermafiber® Safing insulation used in conjunction with an approved fill, void, or Penetration Firestop ASTM E814 or cavity material sealant or other approved Systems UL 1479 material in through -penetration firestop systems Complies Thermafiber® Safing insulation used in Fire Resistance conjunction with an approved fill, void, or of Building Joint UL 2079 cavity material in construction joint systems Systems Complies Fire Tests Firestop Systems CAN/ULCS115 Complies Thermafiber® Safing mineral wool insulation products are designed to provide enhanced fire protection in perimeter fire containment systems tested to ASTM E2307, floor and wall penetrations, construction joints, and other firestopping applications. These products are non- combustible, moisture -resistant, non -corrosive, non -deteriorating, mildew -resistant and vermin -resistant. ThermafibeO Safing provides thermal insulation, fire containment, and enhanced acoustical performance in many different UL and Intertek (formerly OPL) listed fire containment assemblies of 1, 2, and 3-hr ratings. Standards, Code Compliance ASTM C612, Types IA, IB, II, III, IVA Technical Data TESTED TO ASTM C518 ACTUAL DENSITY "K" @ 7501240C] BTU.IN/HR.SQ FT. OF 'R" VALUE PER INCH OF THICKNESS2 4.0 pcf 0.23 4.3 6.0 pcf 0.23 4.3 2 R = thickness divided by'k.' Perimeter Fire Containment Systems Per ASTM E2307 Safing insulation is a critical component of any perimeter fire containment system. Thermafiber, Inc. has performed decades of testing in all of the perimeter fire containment systems listed below. • Aluminum Spandrel • Steel Stud-Framed/Gypsum Sheathing • Glass Spandrel • Granite Spandrel • Precast Concrete Spandrel • Steel Back Pan For more complete test information, see UL® and Intertek® (formerly OPL) Directories. For a full listing of fire containment systems, visit www.thermafiber.com. UL Reference = TYPE SAF. For additional job -specific details and accessory materials necessary to complete the Perimeter Fire Containment System, please refer to UL® and Intertek®design listings 3,4 See Owens Corning publication "Enclosure Solutions Perimeter Fire Containment System E2307 Perimeter Technical Bulletin" (Pub. No. 10020920) for more information. See Owens Corning publication "Thermafiber" Perimeter Fire Containment System Guide" (Pub. No.10022722) for more information. 3 UL Fire Rated Designs, UL 333 Pfngsten Road, Northbrook, IL 60062. 4 Intertek Laboratories Designs, Fire Resistance Directory, Intertek 16015 Shady Falls Rd. Elmendorf, TX 78112 Safing products are approved by New York City Board of Standards & Appeals -(under BSA 39-74-SM & accepted by MEA-209-32-M, Vol. 4). Product Data Sheet I Thermafiber® Safing I April 2023 Availability PRODUCT AVAILABLE THICKNESS STANDARD DIMENSIONS-6 Safing 4.0 pcf 1 •-7' in vz" increments 24" x 46" Safing 6.0 pcf 2•, 3•, 4-, 6• 24" x 4B" Tolerances +v<'", -ve° Width: ±ve", Length: ±'/z" 5 See our product guide for more details. 6 custom sizes are available upon request. Installation All firestopping insulation should be installed per the tested and listed assembly requirements that most closely represent the project conditions. • Perimeter Fire Containment Installation: Thermafiber® Safing insulation should be compression -fitted between the slab edge and the Thermafiber® FireSpan® curtain wall insulation, leaving no voids per the UL® or Intertek® design listing. • Penetration Application: Thermafiber® Safing insulation should be cut slightly larger than the opening and compression -fitted into the opening, leaving no voids per the UL® or Intertek® design listing. • Construction Joint Application: Thermafiber® Safing insulation should be compression -fitted into the joint opening, leaving no voids per the UL11 or Intertek® design listing. Product Options • Safing 4.0, 2-inch or greater thickness, is available with a vapor - retarding foil -facing. • Safing 6.0,1.5-inch or greater thickness, is available with a vapor - retarding foil -facing. • Recycled Content Options',': • Standard Fiber ................................ ............................ :........ .........70°i° Formaldehyde -free product available. See Owens Corning publication Thermafiber® Safing Formaldehyde -Free Mineral Wool Insulation Data Sheet (Pub. No. 10023216) for more information. 7 Recycled content options other than standard must be specified at time of order. Thermafiber Insolutionsv Thermafiber Insolutions® offers industry -leading technical and engineering assistance to architects, specifiers, and contractors. These services include CAD drawings, engineering judgments, LEED® credit information, and product recommendations. Contact our technical services department at 1-888-834-2371 or email Thermafiberinsolutions@owenscorning.com. Environmental and Sustainability Owens Corning is a worldwide leader in building material systems, insulation, and composite solutions, delivering a broad range of high -quality products and services. Owens Corning is committed to driving sustainability by delivering solutions, transforming markets, and enhancing lives. More information can be found at www.owenscorning.com. Certifications and Sustainable Features 'Verified by ICC-ES to contain a minimum of 70% recycled content. See ICC-ES Evaluation Report VAR-1025 at icc-es.org. • Environmental Product Declaration (EPD) has been certified by UL Environment. For more information, visit ul.com/epd. • Safing Products have a published Health Product Declaration (HPD). • This product receives SAFETY Act designation by the U.S. Department of Homeland Security. For more information, visit safetyact.gov. ICC . �► �' '� �SAVEa UL I ..� sm Made in the USA Intertek Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient's sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for, the accuracy or reliability of data associated with particular uses of any product described herein. Owens Corning reserves the right to modify this document without prior notice. LEED® is a registered trademark of the U.S. Green Building Council. Green Globes® is a registered trademark of Green Building Initiative, Inc. UL® and the UL® logo are trademarks of UL, LLC. INTERTEK and the Intertek logo are registered trademarks of Intertek Group plc. Notes For additional information, referto the Safe Use Instruction Sheet (sUIS) found in the SIDS Database via http://sds.owenscorning.com. THERMAMBER, INC. ONE OWENS CORNING PARKWAY TOLEDO, OH 43659 USA 888-TFIBERI 1834-23711 www.owenscorning.com/thermafiber Pub. No.10021130-G. Printed in U.S.A. April 2023. © 2023 Owens Corning. All Rights Reserved. Material Information Statement Articles According to Regulation (EC) 1907/2006, Article 32 Revision: 12.09.2023 Version: 27 1 Product identifier Trade name: • Bottom track seal CFS-BTS • CFP-ES ENDO-SHIELD • Firestop Bandage CFS-B / CFS-CB / CP 646 • Firestop Back Pan Strip CFS-BPS • Firestop Block CFS-BL / CFS-BL P • Firestop Board CP 675 • Firestop Boot CFS-BO • Firestop Box Insert • Firestop Cable Collar CFS-CC / CFS-RCC / CFS-RCC EXT • Firestop Cable Module CFS-T • Firestop Cast -in device and accessories CP 680 / CP 681 / CFS-CID / CFS-CID MD P/M/ CFS-CID MD HS GUI / CFS- CID MD PLT W2/W3 / CFS-CID MD HS / CFS-CID ARB TE- Y / CFS-CID ARB TE-C / CFS-CID U • Firestop Coated Board CFS-CT B / CFS-CT HDB / CP6701 CP673 / CP676 • Firestop Collar CFS-C / CFS-C P • Firestop Collar CP 643 / CP 644 • Firestop Composite Sheet CFS-COS • Firestop Cord CFS-CO • Firestop Cushion CP 651 N • Firestop Drop -In Device CFS-DID • Firestop Edge of Slab QuickSeal CFS-EOS QS • Firestop Endless Collar CFS-C EL • Firestop Filler Module CFS-T FB • Firestop Flex Seal CFS-FS • Firestop Gangplate CFS-SL GP • Firestop Module Box CFS-MB / CP 657 11.2 Application of the listed articles • Firestop Plug CFS-PL / CP 658 • Firestop Plug Seal CFS-T RR / CFS-T RRS • Firestop Retrofit Sleeve CFS-SL RK • Firestop Sleeve CP 645 • Firestop Sleeve Kit CFS-SL SK • Firestop Modular Sleeves and accessories CFS-MSL / CFS- MSL GPP Pre -Installed Gang Plates / CFS-MSL FGR Floor Grids / CFS-MSL GCL (Ganging Clips) / CFS-MSL GPA Adjustable Gang Plates / CFS-MSL GPR Retrofit Gang Plates • Firestop Speed Sleeve CFS-SL / CFSSL GA / CP 653 • Firestop Top Track Seal CFS-TTS • Firestop Top Track Seal CFS-TTS MD • Firestop Top Track Cover CFS-TTS MD C • Firestop Top Track Plug CFS-TTS MD P • Firestop Top Track Seal CFS-TTS 212 • Firestop Top Track Seal CFS-TTS R • Firestop Wedge Seal CFS-T WD120 • Firestop Wrap Strip CFS-W EL / SG / P / CP 648 • Foil Tapes CS -FT • Intumescent fagade cavity closer CP674 • Joint Sealing Tapes CS-JST • Mineral Wool • Mineral Wool Boards • Multifunctional Tapes CS-MFT • Pre -coated Mineral Wool Boards • Smoke & Acoustic Track Seal CS-TTS SA • Speed Plug CP 777 • Speed Strip CP 767 Construction industry. Refer to Hilt! product literature, technical data sheets, 3rd party published listings and national approvals for specific application information. For more details, please contact your local Hllti organization through htto://www.hilti.group 1 3_Manufacturer / Supplier Hilt! AG Feldkircherstr. 100 FL-9494 Schaan Liechtenstein Customer Service Phone +423 (0)844 84 84 85 Fax +423 (0)844 84 84 86 P — i-111 Other information A Safety Data Sheet is not required due to the classification of these products as "articles" according to Regulation (EC) No. 1907/2006 of 18 December 2006 (EU) / 29CFR 1910.1200 (U.S.A.). Consequently, these products are exempted from CLP / OSHA Labeling and SDS requirements. These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. Informing department: chemicals.hse whilti.com LARSON DANIELSON Construction Company, Inc. QUALITY CONSTRUCTION SINCE 1908 302 Tyler Street - LaPorte, Indiana 46350 (219) 362-2127 • Fax (219) 362-2848 City of South Bend Public Works Project 124-038R Material List 02/ 1 1 /2025 Fire Suppression System: • Qty (2) Janus Sv 130 Agent Cylinders 951b. agent fill per cylinder (Connected Reserve) • Qty (1) 190 FK-5-1-12 Agent Charged per pound (approximate, amount will be determined during final system calculations) • Qty (2) Cylinder Strap • Qty (2) Electric Linear Actuator • Qty (1) Manual Override • Qty (1) Pressure Supervisory Switch • Qty (1) Discharge Nozzle • Qty (2) Liquid Level Indicator • Qty (1) Addressable Agent Release Control Panel • Qty (2) Photoelectric Smoke Detector with Base • Qty (1) Manual Release Station • Qty (1) Main Reserve Switch • Qty (1) Strobe Marked "Agent Release" • Qty (I Abort Switch • Qty (1) Keyed "Disablement" Switch • Qty (2) Batteries • Qty (3) Relay Module • Qty (4) Monitor Input Module • Qty (1) Discharge Bell • Lot: Piping, fittings, wiring — where needed, conduit — where needed, hanger materials - where needed, signage. Fire Stop Subcontractor has sealant materials within submittal. Fire Stopping is under Fire Suppression Subcontractor. Electrical Materials: • Qty (1) Dedicated 20-Amp 120V circuit • Contactors & relays for disconnect switches (on fan unit indoors) to lock out fans upon alarm. • Wire Relay for exterior condensing unit upon alarm activation. Framing Materials: • Hat Channel for CMU block wall. • Metal track & studs for door infill. • Batt insulation for door infill. • Drywall for door infill & to extend drywall up to existing 9'-6" plaster ceiling. • Clear Anodized Door Seal • Clear Anodized Automatic Door Bottom HVAC Materials: • Sheet metal blank for existing Return Air Grille Painting Materials: • Drywall tape, patches, & paint for walls & door frame. www.ldconstruction.com Equal Opportunity Employer BOARD OF PUBLIC WORKS AGENDA ITEM REVIEW REQUEST FORM Date: 2/3/2025 Name: Jake Koestner Department of Public Works — Engineering Division BPW Date: 2/11/2025 Phone Extension: 7483 Required Prior to Submittal to Board BPW Attorney X Attorney Name Dept. Attorney ❑ Attorney Name Purchasing ❑ Check the Appropriate Item Type — Required for All Submissions ❑ Professional Services Agreement ❑ Contract ❑ Proposal ❑ Open Market Contract ❑ Amendment/Addendum ❑ Special Purchase, QPA ❑ Bid Opening ❑ Bid Award ❑ Req. to Advertise ❑ Title Sheet ® Quote Opening ❑ Quote Award ❑ Reject Bids/Quotes ❑ Proposal Opening ❑ C/O & PCA No. ❑ PCA ❑ Chg. Order, No. ❑ Traffic Control ❑ Resolution n Other: n Ease./Encroach Company or Vendor Name New Vendor MBE/WBE Contractor Project Name Project Number Funding Source Account No. Amount Terms of Contract Special Contract Provisions Purpose/Description Information ❑ Yes ❑ If Yes, Approved by Purchasing ❑ No ❑ MBE Completed E-Verify Form Attached ❑ Nos WWTP Server Room Fire Suppression System 124-038R PR-00035314 Lump Sum This project consists of the installation of a clean agent fire suppression system in the South Bend WWTP Server Room with the necessary wall modifications to provide adequate air sealing to the room. IL For Change Orders Only Amount of ❑ Increase $ ❑ Decrease ($ ) Previous Amount Current Percent of Change New Amount Increase % Decrease ( % Increase % Total Percent of Change: Decrease % Time Extension Amount: New Completion Date: