Loading...
HomeMy WebLinkAboutAward Quote - Locust Water Booster Pump Improv Proj No 124-058 - Engineered Solutions1316 COUNTY -CITY BUILDING 227 W. JEFFERSON BOULEVARD SOUTH BEND, INDIANA 46601-1830 PHONE 574/235-9251 FAx 574/235-9171 CITY OF SOUTH BEND TAMES MUELLER, MAYOR BOARD OF PUBLIC WORKS November 26, 2024 Mr. Tim Hovda Engineered Solutions Midwest Inc. 5609 W. 74th St. Indianapolis, IN 46278 thovdagengineeredsolutions. com RE: Quotation Award — Locust Water Booster Pump Station Improvements — Project No. 124-058 Dear Mr. Hovda: At its November 26, 2024 meeting, the Board of Public Works awarded the above referenced quotation to you in the amount of $138,223. Please forward the following documents in one submittal by December 10, 2024 to my attention for Board of Public Works approval at hhorvath(a)southbendin.gov : 3) One (1) signed original of the Contract (enclosed); and 4) Certificate of Insurance naming the City of South Bend as an additional insured. If you have any further questions, please call this office at (574) 235-9251. Sincerely, /s/ Theresa Heffner Theresa Heffner, Clerk Enclosures TH/hh ELIZABETH A. MARADIK JOSEPH R. MOLNAR GARY A. GILOT MURRAY L. MILLER BREANA N. MIcou 1316 COUNTY -CITY BUILDING 227 W. JEFFERSON BOULEVARD SOUTH BEND, INDIANA 46601-1830 PHONE 574/235-9251 FAx 574/235-9171 CITY OF SOUTH BEND TAMES MUELLER, MAYOR BOARD OF PUBLIC WORKS November 26, 2024 Mr. Frank Williams Peerless Midwest, Inc. 55860 N. Russell Industrial Pkwy. Mishawaka, IN 46545 Frank.williams(acrc peerlessmidwest.com RE: Quotation Award — Locust Water Booster Pump Station Improvements — Project No. 124-058 Dear Mr. Williams: At its November 26, 2024 meeting, the Board of Public Works awarded the above referenced quotation to Engineered Solutions Midwest, Inc. in the amount of $138,223. We thank you for quoting and hope you will quote with us again in the future. If you have any further questions, please call this office at (574) 235-9251. Sincerely, /s/ Theresa Heffner Theresa Heffner, Clerk Enclosures TH/hh ELIZABETH A. MARADIK JOSEPH R. MOLNAR GARY A. GILOT MURRAY L. MILLER BREANA N. MIcou INTER -OFFICE MEMORANDUM DEPARTMENT OF PUBLIC WORKS DIVISION OF ENVIRONMENTAL SERVICES TO: Members of the Board of Public Works Michael Schmidt, Assistant City Attorney Public Works Theresa Heffner, Clerk of the Board of Public Works FROM: Jacob M. Klosinski, P.E., Assistant City Engineer SUBJECT: Agenda Request — Quote Award 124-058 Locust Water Booster Pump Station Improvements (PROJ# 00000582; PR#00037523) DATE: November 14, 2024 The Board of Public Works opened public quotes for Project No. 124-058 Locust Water Booster Pump Station Improvements on November 12, 2024. The Division of Engineering and Division of Water Works reviewed the two quotes that were received. A Bid Tabulation is attached to the memorandum detailing the line items within the Quote Form. The quotes ranked as follows: BASE QUOTE CONTRACTOR BASE QUOTE 1. Engineered Solutions Midwest, Inc. Indianapolis, IN $138,223.00 2. Peerless Midwest, Inc. $141,787.00 The Division of Engineering and Division of Water Works recommend the award of the Base Quotation for Project No. 124-058 Locust Water Booster Pump Station Improvements to Engineered Solutions Midwest, Inc. for the total base quotation of $138,223.00. Engineered Solutions Midwest, Inc. was the lowest, responsive, and responsible bidder and submitted a complete quote. Peerless Midwest, Inc.'s quote was incomplete and did not include product data requested with the quote submittal. Peerless Midwest included MBE and WBE paperwork but was unable to supply a utilization plan that would meet the project MBE and WBE goals. Refer to Quote Tabulation, attached. Funding for this project was provided through Water Works Capital — Capital, Account 622-06-604-620-442010. For questions regarding the subject Agenda Request, contact Jacob M. Klosinski (Ext. 9496) at the Division of Engineering. BOARD OF PUBLIC WORKS CITY OF SOUTH BEND, INDIANA PUBLIC WORKS CONTRACT This Agreement is made and entered into this 26th Day of November, 2024, by and between Engineered Solutions Midwest, Inc. (the "Contractor"), and the Board of Public Works (the "Board"). The Contractor covenants and agrees to make the following improvement, as fully set out in the Request for Quotations, Standard Specifications, Special Provisions, Plans, and Bid Proposals, all of which are set forth as a part of this Contract, for: PROJECT NO. 124-058 DESCRIPTION: LOCUST WATER BOOSTER PUMP STATION IMPROVEMENTS COMPLETION DATE: SEE SPECIFICATIONS AMOUNT: $138,223 FUNDING: PR-00037523 The unit prices for this improvement were those prices as received and accepted by the Board on the 26th Day of November 2024. The Contractor further agrees to notify the assigned Engineer when this improvement is completed. This notification shall be in the form of a Project Completion Affidavit, signed by the Contractor. Upon final acceptance of the improvement by the Engineer, the Contractor's final estimate will be presented to the Board for final Payment with one (1) copy of the Project Completion Affidavit and one (1) copy of a Waiver of Lien. Each of the Parties, by signing below, represents and warrants to the other Party that he/she/it has the authority to bind the named person or entity to this Agreement. CITY OF SOUTH BEND, INDIANA BOARD OF PUBLIC WORKS Elizabeth A. Maradik, President Gary A. Gilot, Member Murray L. Miller, Member M Joseph R. Molnar, Vice President Briana Micou, Member �4 Attest: Theresa M. Heffner, Clerk Date: November 26, 2024 ENGINEERED SOLUTIONS MIDWEST, INC. Printed Name Signature BASE QUOTATION / PROPOSAL QUOTE TABULATION Locust Water Booster Pump Station Improvements Project No: 124-058 Engineered Solutions Midwest, Inc]Peerless Midwest, Inc. Item No. Line Item Quantity Unit Unit Price Cost Unit Price Cost 1 Installation and Labor, Pump, Process Piping, Electrical, Integration 1 LS $ 24, 784.50784.50 $ 24, $ 24,670.00 $ 24,670.00 2 Pump and Motor Equipment 1 LS $ 26,075.00 $ 26,075.00 $ 25,790.00 $ 25,790.00 3 Variable Frequency Drive Equipment 1 LS $ 16,363.50 $ 16,363.50 $ 17,848.00 $ 17,848.00 4 Pipe Materials (Piping, Valves, Gauges) 1 LS $ 14,350.00 $ 14,350.00 $ 8,347.00 $ 8,347.00 5 Programmable Lofic Controller, Allen-Bradley, Compact Logix Model 5380 2 EACH $ 7,598.50 $ 15,197.00 $ 12,800.00 $ 25,600.00 6 Human Machine Interface, Panel View 5000 Series 2 EACH $ 7,254.00 $ 14,508.00 $ 8,796.00 $ 17,592.00 7 IHMI and PLC Installation and Programming 1 LS $ 26,945.00 1 $ 26,945.00 1 $ 21,94.0.00 $ 21,940.00 TOTAL $ 138,223.00 $ 141,787.00 Motor, Pump and Pump Curve Information Included with Quotation YES NO Variable Frequency Drive Product Data Included with Quotation YES NO MBE Good Faith Efforts Paperwork / Meets Goals YES / YES YES / NO WBE Good Faith Efforts Paperwork / Meets Goals YES / YES YES / NO Contractor's Affidavit YES YES Certificate of Insurance YES NO Complete and Responsive Paperwork YES NO I hereby certify that the above truly and accurately represents quotes received for this project on November 12, 2024. ,9 ,e, 71M Jacob M. Klosinski, P.E. - Assistant City Engineer 11/14/2024 CITY OF SOUTH BEND, INDIANA CONTRACTOR'S QUOTE FOR PUBLIC WORK ixr PROJECT NAME: Locust Water Booster Pump Station Improvements PROJECT NO. 124-058 QUOTES DUE Tuesday, November 12, 2024, at 9:00 a.m. Local Time, sealed electronic bids are to be submitted by email to bpwbids@south bend in.gov Date: Address: City/State/Zip: Email Address: (Must be completed for all quotes. Please type or print) ItFirm: I✓y-41nfccc Wc. --Iq-+ti _54 I0612L5 I^4 `jj Z, ,? Telephone Number: (31-7) 9_15- 13&i ihovda C�e��a`•+n�e�esoli a�,s, com Agent of Bidder (if Applicable): Pursuant to notices given, the undersigned offers to furnish labor and/or material necessary to complete the public works project of: Locust Booster Pump Station Improvements the City of South Bend, Indiana, in accordance with plans and specifications prepared by: The Citv of South Bend. Department of Public Works and dated October 2024 for the sum of (enter the Total Quote as shown on the Proposal) � 3g, ZZ_3, d v ($ i 38"r ZZ3.QJ (Enter Sum of Total Quote plus Alternates shown on Proposal) (Numerical) If alternative quotes apply, the undersigned submits a proposal for each in accordance with the notice. Any addendums attached will be specifically referenced at the applicable page. If additional units of material included in the contract are needed, the cost of units midst-e the same as that shown in the original contract if accepted by the City of South Bend. If the quote i o� wa on a unit basis, the itemization of the units shall be shown on a separate attachm By {5ig to ) (Printed Narn6 of Person Signing) The above quote is accepted this Subject to the following conditions: ACCEPTANCE day of CITY OF SOUTH BEND, INDIANA BOARD OF PUBLIC WORKS VLL(4 Elizabeth A. Maradik, President Gary A. Gilot, Member Version 3/15/2024 Murray L. Miller, Member 20 ',�_2 P1 Joseph R. Molnar, Vice President Briana Micou, Member (t,, /. Public Works Quote Attest: Theresa M. Heffner, Clerk Date: November 26, 2024 QUOTE/PROPOSAL „sue CITY OF SOUTH BEND PROJECT NAME Locust Water Booster Pump Station Improvements PROJECT NO. 124-058 QUOTES DUE 12, 2024, at 9:00 a.m. Local Time, sealed electronic bids are Item No. Description Quantity Unit Unit Price Total Amount 1 Installation and Labor, Pump, Process Piping, Electrical, Integration 1 LS $ Aq, 7g9, 5i $at'f`� ,7XN•50 Pump and Motor Equipment C h0 rx gt99.594 C Pump Manufacturer/ Model No.: 2 6ai'yot' / -.?&-n n26(ra Ste) 1 LS $ 26 015X $ 21n,0�5•Ul7 Motor Manufacturer / Model No.: Attach copy of Motor, Pump, and Pump Curve information with Quote Variable Frequency Drive Equipment VFD Manufacturer MA 3 VFD Model No. Fi('.d15�'Q'31-/Z'iA'� 1 LS $I<Q,3(o3,5fl $�In,363,5� Attach copy of Product Data with Quote 4 Pipe Materials (Piping, Valves, Gauges) 1 LS $ N 3 T.0D $ (N 3 50. as 5 Programmable Logic Controller, SIG Coral$ Allen-Bradley, Compact Logix Model 5380 2 EACH $�549,50 $15lion Do 8 Human Machine Interface, Panel View 5000 series 2 EACH $ a5y� $ IL�i �jp�,QQ 7 HMI and PLC Installation and Programming 1 LS $ zla,aMi.Ct� $ ztp,9ti5.0U Total Amount of Quote $ 1351, 1 73,0 Firm: Ci-ig;nECred cS`orlLAbns OWWesf !n� 55/ Address: 0001 L0. 7Y+h 6+ City/State/Zip: )n4joLS IN 4019 Telephone Number: (3l7) Q73- 13C4 Fax Number: (3l'1 ) 755-t�55 By (Signature) (Printed Name of Person Signing) Version 3/15/2024 Page 21 Public Works Quote When the prospective Contractor is unable to certify to any of the statements below, it shall attach an explanation to this Affidavit CONTRACTOR'S NON -COLLUSION AND NON -DEBARMENT AFFIDAVIT, CERTIFICATION REGARDING INVESTMENT WITH IRAN, EMPLOYMENT ELIGIBILITY VERIFICATION, NON-DISCRIMINATION COMMITMENT AND CERTIFICATION OF USE OF UNITED STATES STEEL PRODUCTS OR FOUNDRY PRODUCTS (Must be completed for all quotes and bids. Please type or print) STATE OF I KLDi Pm) ) ) SS: Mar i On COUNTY ) The undersigned Contractor, being duly sworn upon his/her/its oath, affirms under the penalties of perjury that: 1. Contractor has not, nor has any other member, representative, or agent of the firm, company, corporation or partnership represented by him, entered into any combination, collusion or agreement with any person relative to the price to be bid by anyone at such letting nor to prevent any person from bidding nor to induce anyone to refrain from bidding, and that this bid is made without reference to any other bid and without any agreement, understanding or combination with any other person in reference to such bidding. Contractor further says that no person or persons, firms, or corporation has, have or will receive directly or indirectly, any rebate, fee, gift, commission or thing of value on account of such sale; and 2. Contractor certifies by submission of this proposal that neither contractor nor any of its principals are presently debarred, suspended, proposed for debarment, declared ineligible, or voluntarily excluded from participation in this transaction by any Federal department or agency; and 3. Contractor has not, nor has any successor to, nor an affiliate of, Contractor, engaged in investment activities in Iran. a. For purposes of this Certification, "Iran" means the government of Iran and any agency or instrumentality of Iran, or as otherwise defined at Ind. Code § 5-22-16.5-5, as amended from time -to -time. b. As provided by Ind. Code § 5-22-16.5-8, as amended from time -to -time, a Contractor is engaged in investment activities in Iran if either: i. Contractor, its successor or its affiliate, provides goods or services of twenty million dollars ($20,000,000) or more in value in the energy sector of Iran; or iL Contractor, its successor or its affiliate, is a financial institution that extends twenty million dollars ($20,000,000) or more in credit to another person for forty-five (45) days or more, if that person will (i) use the credit to provides goods and services in the energy sector in Iran; and (ii) at the time the financial institution extends credit, is a person identified on list published by the Indiana Department of Administration. 4. Contractor does not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the Contractor subsequently learns is an unauthorized Version 3/15/2024 Page - 18 . Public Works Quote alien. Contractor agrees that he/she/it shall enroll in and verify the work eligibility status of all of Contractor's newly hired employees through the E-Verify Program as defined by I.C. 22-5-1.7-3. Contractor's documentation of enrollment and participation in the E-Verify Program is included and attached as part of this bid/quote; and 5. Contractor shall require his/her/its subcontractors performing work under this public contract to certify that the subcontractors do not knowingly employ or contract with an unauthorized alien, not retain any employee or contract with a person that the subcontractor subsequently learns is an unauthorized alien, and that the subcontractor has enrolled in and is participating in the E-Verify Program. The Contractor agrees to maintain this certification throughout the term of the contract with the City of South Bend, and understands that the City may terminate the contract for default if the Contractor fails to cure a breach of this provision no later than thirty (30) days after being notified by the City. 6. Persons, fines, partnerships, corporations, associations, or joint venturers awarded a contract by the City of South Bend through its agencies, boards, or commissions shall not discriminate against any employee or applicant for employment in the performance of a City contract with respect to hire, tenure, terms, conditions, or privileges of contract or employment, or any matter directly or indirectly related to contracting or employment because of race, sex, religion, color, national origin, ancestry, gender expression, gender identity, sexual orientation, or due to age or disability that does not affect that person's ability to perform the work. In awarding contracts for the purchase of work, labor, services, supplies, equipment, materials, or any combination of the foregoing including, but not limited to, public works contracts awarded under public bidding laws or other contracts in which public bids are not required by law, the City, its agencies, boards, or commissions will consider the Contractor's good faith efforts to obtain participation by those subcontractors certified by the State of Indiana as a Minority Business ("MBE") or as a Women's Business Enterprise ("WBE") as a factor in determining the lowest, responsible, responsive bidder. Contractors seeking the award of a City contract cannot be required to award a subcontract to an MWBE; however, they may not unlawfully discriminate against said MBE/WBE. On goal -eligible contracts, Contractors are required to either meet both MBE and WBE utilization goals or demonstrate that the Contractor has made good faith efforts to obtain participation from MBE and WBE subcontractors. A finding of noncompliance or a discriminatory practice shall prohibit that Contractor from being awarded a City contract for a period of one (1) year from the date of such determination, and such determination may also be grounds for terminating the contact to which the discriminatory practice or noncompliance pertains. 7. The undersigned Contractor agrees that the following nondiscrimination commitment shall be made a part of any contract which it may henceforth enter into with the City of South Bend, Indiana or any of its agencies, boards or commissions. Contractor agrees not to discriminate against or intimidate any employee or applicant for employment in the performance of this contract with privileges of employment, or any matter directly or indirectly related to employment, because of race, religion, color, sex, gender expression, gender identity, sexual orientation, handicap, national origin or ancestry. Breach of this provision may be regarded as material breach of contract. Version 3/15/2024 Page - 19 Public Works Quote I, the undersigned bidder or agent as contractor on a public works project, understand my statutory obligations to the use of steel products or foundry products made in the United States (I.C. 5-16- 8-1). I hereby certify that I and all subcontractors employed by me for this project will use steel products or foundry products made in the United States on this project if awarded. I understand I have an affirmative duty to notify the City in my bid that my proposal does not include the use of steel products or foundry products made in the United States. I understand it is my sole obligation and responsibility to provide a justification to the City, subject to review and approval, why the cost of United States made steel or foundry products is unreasonable. Prior to award and upon submission of bid which does not use steel products or foundry products made in the United States, the City, through its director of public works, shall make a determination if the price of United States made steel or foundry is unreasonable. I understand that violations hereunder may result in forfeiture of contractual payments. s*r I hereby affirm under the penalties of pedury that the facts and information contained in the foregoing bid for public works are true and correct. Dated this /Z day of / , 20ZY 4'9" �' Al Sly ' • Co orBidd ) 7�.• NOTARY PUBLIC•y. g Signature of Contractor/Bidder or Its Agent 0721535 a: �...p L * - NOTARY REAL s�. yean E.on?*? �P,' Printed Name and Title r qTF OF IIAD . •�•nnuu,o„pd` Subscribed and sworn to before me this I t day of i I 20 LH My Commission Expires 7 / z t / 27 Not Public * Public County of Residence 11309A-f Version 3/15/2024 Page - 20 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM MBE-1.0 MBE UTILIZATION PLAN This completed form should be supplied with Bids that pertain to City of South Bend Public Works Projects involving MBE participation. It is the bidder's sole responsibility to verify whether any listed minority or woman business meets the MBE qualifications. ***Goals should be calculated based on the Base Bid only.*** Project Number: 124-058 Project Name: Locust Water Booster Pump Station Improvements Bidder: minor✓P/% �t 7r dtC /��%[Jef7 �pC Total Bid Amount: /3 Y, Z 23. 00 MBE Goal: Z% Page of Name &Address of MBE Primary Contact Person Name/Tele hone ( p ) Scope of Work to be Performed (Attach scope/schedule if you need additional space) Dollar Amount of MBE Component Percentage of Totalgid/Pro osal eam Gv�s-�.✓ bup�l U� Cftx�slm�h�e� barn t7-yL3-23-75� Ir1CIUS4ria-1 Supplies eEquiFjm,� � 7,�t 3O.o� 5.7yv1) r Submitted by: l / / Z A� Print Name Signature Date ***Goals should be calculated based on the Base Bid only.*** Version 3/15/2024 Page - 22 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM WBE-1.0 WBE UTILIZATION PLAN This completed form should be supplied with Bids that pertain to City of South Bend Public Works Projects involving WBE participation. It is the bidder's sole responsibility to verify whether any listed minority or woman business meets the WBE qualifications. ***Goals should be calculated based on the Base Bid only.*** Project Number: 124-058 Project Name: Locust Water Booster Pump Station Improvements �`( Total Bid Bidder: �nQ nCf✓irj� it r%i0/IS {�d4JwT �rr Amount: 9 13WBE Goal: S°lo v Page -of - Name & Address of WBE Primary Contact Person (Name/Telephone) Scope of Work to be Performed (Attach scope/schedule if you need additional space) Dollar Amount of WBE Component Percentage of Total Bid/Proposa I V10,rI —Te.k. I wn L�nclscx.�. I vldust"-d l SL)pp Ices , £Ylgi neerinc� F £q✓o�ma.n�F Ov,9`6 Ql,(o3% Submitted by: Print Name Signature/Date ***Goals should be calculated based on the Base Bid only.*** Version 3/15/2024 Page - 23 Public Works Quote ,n I„ na CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN - FORM MBE-2.0 EVIDENCE OF GOOD FAITH EFFORTS This completed form should be included as part of the Bids documents related to City of South Bend Public Works Projects requiring Good Faith Efforts to obtain MBE participation. Project Number: 124-058 Date: /lJ///Z`/ Project Name: Locust Water Booster Pump Station Improvements Bidder: _�ha�netvrd , luflon-s tkbd w cf IA4 sr--. Contact Person: I r ✓Y 1 l {pV Q Telephone: 3 /7 - 9 73 — /3W& Address: 5toCJ9' LJ %rf �+ City: _ lrIddLs State: 1)4 zip: q1V 7p Email: _ *V1 OVd Cw 0 P.i e e,rINS rn To determine whether a bidder has demonstrated goo faith efforts to reach the MBE utilization goal set forth in the City of South Bend Public Works Project Specifications, the City and its agencies, boards, or commissions, REQUIRE ALL of the following Good Faith Efforts as listed in the table below': EVIDENCE OF GOOD FAITH EFFORTS MBE LIST(S): The bidder reviewed 1) the City of South Bend's Minority and Women Business Enterprise Inclusion Program Plan; 2) the list of certified MWBEs provided by the City; and 3) the Indiana Department of Administration list of Minority and Women Owned Businesses (both certified and non -certified) found at: htto://www.in.00v/idoal. GOOD FAITH EFFORTS TO OBTAIN MBE PARTICIPATION The bidder shall initial each item below, as evidence of its good faith efforts to obtain MBE participation in the awarded contract. -I I affirm that reviewed the City of South Bend's Minority and Women Business Enterprise Inclusion Program Plan and the Indiana Department of Administration's certified list of Indiana Minority and Women Business Enterprises, found on their website (http://www.in.gov/idoa). 1 affirm that I have made good faith efforts to select portions of the contract work to be performed by MBEs, including, where appropriate, breaking out contract work items into economically feasible units to facilitate MBE participation. I affirm that 1 have made good faith efforts to solicit through all reasonable and available means the interest of all MBEs in the scopes of work of the contract. I affirm that I attended all pre -bid meetings scheduled by the City of South Bend to inform MBEs of contracting and subcontracting opportunities. I affirm that I advertised in general circulation and/or trade association publications concerning subcontract opportunities and allowed MBEs reasonable time to respond to such advertisements. affirm that I performed any and all necessary steps to provide written notices in a manner ellI reasonably calculated to inform MBEs of subcontracting opportunities and allowed sufficient time for MWBEs to participate effectively. 441 I affirm that I followed up on initial solicitations with interested MBEs. I affirm that I negotiated with interested MBEs in good faith, including providing such MBEs with adequate information about the plans, specifications and other requirements of the subcontract. I affirm that I have made good faith efforts to assist interested MBEs in obtaining bonding, lines of credit, or insurance as required by the City or the bidder, where appropriate. Version 3/15/2024 Page - 24 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM MBE-2.0 EVIDENCE OF GOOD FAITH EFFORTS 1 affirm that I have made good faith efforts to assist interested MBEs in obtaining necessary equipment, supplies, materials, or related assistances or services, where appropriate. I affirm that 1 did not reject any MBEs as unqualified without sound business reasons based on a thorough investigation of their capabilities. CONTRACT RECORDS: The bidder has maintained the following records for each MBE that has bid on the subcontracting opportunity: 1. Name, address, and telephone number; 2. A description of information provided by the bidder or subcontractor; and 3. A statement of whether an agreement was reached, and if not, why not, including any reasons for concluding that the MBE was unqualified to perform the job. V E WNeI daInvnaaradon or Good Faun errorts requires your Initials next to all of the above boxes. Any omissions shall be considered grounds for rejection of the bid by the Board of Public Works. The City of South Bend reserves the right to request additional Information. Version 3/15/2024 Page - 25 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM WBE-2.0 EVIDENCE OF GOOD FAITH EFFORTS This completed form should be included as part of the Bids documents related to City of South Bend Public Works Projects requiring Good Faith Efforts to obtain WBE participation. Project Number: 124-058 Date: it/ 11 17'4 Project Name: Locust Water Booster Pump Station Improvements Bidder: Erigin-c-tad &I 4fcm3 lGe4LOeSt /iuG V ``�� Contact Persom _ —TT rvt r4oyol n Telephone: Address: 54909 ut . eN" 51 City: I r t P lS State: /n( Zip: Email: -t6ovdgIQ eitgineertGlsolvifon •corn To determine whether a bidder has demonstrated good faith efforts to reach the WBE utilization goals set forth in the City of South Bend Public Works Project Specifications, the City and its agencies, boards, or commissions, REQUIRE ALL of the following Good Faith Efforts as listed in the table below': EVIDENCE OF GOOD FAITH EFFORTS WBE LIST(S): The bidder reviewed 1) the City of South Bend's Minority and Women Business Enterprise Inclusion Program Plan; 2) the list of certified MWBEs provided by the City; and 3) the Indiana Department of Administration list of Minority and Women Owned Businesses (both certified and non -certified) found at: httD://www.in.ciov/idoa/. GOOD FAITH EFFORTS TO OBTAIN WBE PARTICIPATION The bidder shall initial each item below, as evidence of its good faith efforts to obtain WBE participation in the awarded contract. I affirm that I reviewed the City of South Bend's Minority and Women Business Enterprise Inclusion Program Plan and the. Indiana Department of Administration's certified list of Indiana Minority and Women Business Enterprises, found on their website (http://www.in.gov/idoa). I affirm that I have made good faith efforts to select portions of the contract work to be performed by WBEs, including, where appropriate, breaking out contract work items into economically feasible units to facilitate MWBE participation. I affirm that I have made good faith efforts to solicit through all reasonable and available means the interest of all WBEs in the scopes of work of the contract. 1 affirm that I attended all pre -bid meetings scheduled by the City of South Bend to inform WBEs of contracting and subcontracting opportunities. I affirm that I advertised in general circulation and/or trade association publications concerning subcontract opportunities and allowed WBEs reasonable time to respond to such advertisements. I affirm that I performed any and all necessary steps to provide written notices in a manner reasonably calculated to inform WBEs of subcontracting opportunities and allowed sufficient time for WBEs to participate effectively. I affirm that I followed up on initial solicitations with interested WBEs. I affirm that I negotiated with interested WBEs in good faith, including providing such WBEs with adequate information about the plans, specifications and other requirements of the. subcontract. I affirm that I have made good faith efforts to assist interested WBEs in obtaining bonding, lines of credit, or insurance as required by the City or the bidder, where appropriate. Version 3/15/2024 Page - 26 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN FORM WBE-2.0' EVIDENCE OF GOOD FAITH EFFORTS I affirm that I have made good faith efforts to assist interested WBEs in obtaining necessary equipment, supplies, materials, or related assistances or services, where appropriate. I I affirm that I did not reject any WBEs as unqualified without sound business reasons on a thorough investigation of their capabilities. CONTRACT RECORDS: The bidder has maintained the following records for each WBE that has bid on the subcontracting opportunity: 1. Name, address, and telephone number, 2. A description of information provided by the bidder or subcontractor; and 3. A statement of whether an agreement was reached, and if not, why not, including any reasons for concluding that the WBE was unqualified to perform the job. V 1 upel anmon»dauon or Good Faith efforts requires your initials next to all of the above boxes. Any omissions shall be considered grounds for rejection of the bid by the Board of Public Works. The City of South Bend reserves the right to request additional information. Version 3/15/2024 Page - 27 Public Works Quote CITY OF SOUTH BEND�tl MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN x'•,+/ FORM MBE-2.1v% MBE CONTACTED I his completed rorm should be supplied with Bids that pertain to City of South Bend Public Works Pr requiring Good Faith Efforts to contact MBEs. It is the bidder's sole responsibility to verify whether any minority or woman business meets the MBE qualifications. Attach additional pages if necessary. PAGE OF Project Number: 124.055 MBE Participation Goal Project Name: Locust Water Booster Pump Station Improvements MBE Firm Owner or Contact at I Telephone: 31-)—LJ23_),315 Fax: Email: GIaLYr12u1�+-77Carrlf.fUGSCY TYPE OF WORK SOLICITED FOR THIS PROJECT: j rl dUS+rro-) SUO j,Y S f Cqupmted RESULTS OF CONTACT WITH THE MBE FIRM: MBE Firm Owner or Contact at MBE Firm Telephone: Fax: Email: TYPE OF WORK SOLICITED FOR THIS PROJECT: RESULTS OF CONTACT WITH THE MBE FIRM: Version 3/15/2024 Page - 28 Public Works Quote CITY OF SOUTH BEND MINORITY AND WOMEN BUSINESS ENTERPRISE INCLUSION PROGRAM PLAN =\ z FORM WBE-2.1 WBE CONTACTED This completed form should be supplied with Bids that pertain to City of South Bend Public Works Pr requiring Good Faith Efforts to contact WBEs. It is the bidder's sole responsibility to verify whether any minority or woman business meets the WBE qualifications. Attach additional pages if necessary. PAGE —OF — Project Number: 124-068 WBE Participation Goal Project Name: Locust Water Booster Pump Station Improvements WBE Firmyar Tek Owner or Contact at WBE Finn _:)awn Lir %asr-LL Telephone: 31-1-T0CD--jJa(X Fax: Email: G�G.WYI�✓Q✓i _'fek.COr TYPE OF WORK SOLICITED FOR THIS PROJECT: 1 1nn/usi-na_1 Suaoh'e4 Fi)gi✓�rt✓f'r�p '7e 4_ Uipiit A RESULTS OF CONTACT WITH THE WBE FIRM WBE Firm Owner or Contact at WBE Firm Telephone: Fax: Email: TYPE OF WORK SOLICITED FOR THIS PROJECT: RESULTS OF CONTACT WITH THE WBE FIRM: Version 3/15/2024 Page - 29 Public Works Quote .4coROI CERTIFICATE OF LIABILITY INSURANCE DAT 11/08/24a/2a THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: It the certificate holder is an ADDITIONAL INSURED, the policy(les) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such andomement(s). PRODUCER SRM Group LLC P.O. Box e, Belleville, IL 62222 NAME; AME:DE :618-365-4966 ACNq; AODRESS:Chelseae@s=—ins.com INSUREIRISI AFFORDING COVERAGE IAJcb INSURER A: LIBERTY SURPLUS INSURANCE 25658 INSURED ENGINEERED SOLUTIONS MIDWEST, INC 5609 WEST 74TH STREET INDIANAPOLIS, IN 46278 INSURER B: TRAVELERS INDEMNITY COMPANY INsuRERc:TRAVELERS PROPERTY CASUALTY CO INSURER D: LLINOIS UNION INSURANCE C MP INSURER E INSURER F : ncvlalvry rvumacrt: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IAR L TYPE OF INSURANCE wyp POLICY NUMBER MPW%D MM/pD/1'LX LIMBS X I COMMERCIAL GENERAL LMSARY CLAIMS -MADE OCCUR EACH OCCURRENCE $ 1,000,006, PREMISES. Ea occuoance S 300000 MEDEXP(Anyonbperson) $ 5 000 F' Y-630-5X292933—TIA-23 12/1/2023 12/1/2024 PERSONAL$ ACV INJURY $ 1,000,000 GEN'L X AGGREGATE LIMIT APPLIES PER: POLICY °Ea 7 LOC GENERAL AGGREGATE $ 2,000, 000 PRODUCTS - COMP/OP AGO $ Z, OOO, OOO $ OTHER: B AUTOMOBILE UABILRV ATO U OWNED ONLY X sCHEpuLEO AUTOON AUTOS HIRED NON-0WNED AUTOSONLY X AUTOS ONLY 810—SX252609-23-14—G 2/i /2023 12 /1/2024 =Nu WIN nt $ 1,000,000 X BODILY INJURY (Per Parson) $ X BODILY INJURY (Per acciden) $ X Par accident) IS C }[ UMBRELLA LWB EXCESS LIAO OCCUR CLAIMS -NAPE CUP-5X294742-23-14 12/1/2023 12/1/2024 EACH OCCURRENCE $10, o0O OOO r AGGREGATE $ DED RETENTION $ $ B WORKERS COMPENSATON AND EMPLOYERS'LIABILITY YIN OFF nRORMBER R CLUDEDxEcurlvE OFFICEWMEM6ER EXCLUDED? ❑ &.&Malin NN) II yes, describe under DESCRIPTION OF OPERATIONS below NIA UB-5X229224A-23-14—G 12/1/2023 12/1/2024 X STATUTE ER EL EACH ACCIDENT 1 000 OOO $ r , E.L DISEASE - EA EMPLOYEI $ 1,000,00.0 E.L. DISEASE -POLICY LIMIT S 1,000,000 D POLLUTION LIABILITY CPY G271695156 010 12/01/2023 12/01/2024 LIMIT $lM/$1M C INSTALLATION FLOATER 4T-660—SX357905—TIL-23 12/01/2023 12/02/2D24 LIMIT $500, 000 A PROFESSIONAL LIAB SAESNAANBS2013 4/25/2u24 12/D1/2024 LIMIT $2M/$2M DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule; may be attached if more space is required) CERTIFICATE HOLDER IS ALSO AN ADDITIONAL INSURED CITY OF SOUTH BEND, IN 227 WEST JEFFERSON BLVD SUITE 1300 N SOUTH BEND, IN 46601 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Co All rinme reccnmd AUORD25(2016/03) The ACORD name and logo are registered marks of ACORD GRUNDFOS N Grundfos Quotation System 23.4.1 Customer ref. / PO Model Tag Number : 001 Stages Service Based on curve number Quantity : 1 Basic model number Date last saved Flow, rated : 1,250.0 USgpm Liquid type Differential head / pressure, rated (requested) : 200.0If Additional liquid description Differential head / pressure, rated (actual) : 200.2 ft Solids diameter, max Suction pressure, rated / max : 0.00 / 0.00 psi.g Solids concentration, by volume NPSH available, rated : Ample Temperature, max Site Supply Frequency : 60 Hz Fluid density, rated / max Performance Viscosity, rated Impeller diameter, rated Impeller diameter, maximum Impeller diameter, minimum Efficiency NPSH required / margin required Ns (imp. eye flow) / Nss (imp, eye flow) MCSF Head, maximum, rated diameter Head rise to shutoff Flow, best eff. point Flow ratio, rated / BEP Diameter ratio (rated / max) Head ratio (rated dia / max dia) Cq/Ch/Ce1Cn [ANSI/HI 9.6.7-2010) Selection status ER 500 450 400 350 300 @ 250 S 200 150 100 50 d C 40 0 20 it. [I� Z 0 n 40959 LC :1 RC 1979-SS Rev 0 : 29 Jan 2024 2:00 PM 3550 rpm Vapor pressure, rated 8.18 in , 9.60 in Material selected 7.50 in 81.66 % Maximum working pressure 19.15 / 0.00 If -Maximum allowable working pressure 1,593 / 13,455 US Units Maximum allowable suction pressure 409.7 USgpm Hydrostatic test pressure 275.2 ft I V19r . 33.96 % Motor sizing specification. 1,088.6 USgpm Margin over specification 114,82% Service factor 85.21 % Power, hydraulic 58.06 % Rated power (based on duty point) 1.00 / 1 00 / 1.00 / 1.00 Max power (non-ovedoading) Acceptable Nameplate motor rating V 4 Cold Water 0.00 in 0.00 % : 68.00 deg F 1.000 / 1.000 SG. 1.00 cP 0.34 osi.a 119.1 psi.g 175.0 psi.g 175.0 psi.g 263.0 psi.g Max power (non -or 0.00 % 1.00 63.15 hp 77.35 hp 78.86 hp 100 hp 174.57 kW 9.60 in 63 70 75 80 \ � � 82 83 83 82 8.18 in \ I25r hp \ 75 7.50 in to fin 70 q, RtluPp NPSHr zuv 40c boa 800 1,000 1,200 1,400 1,600 1.800 Flow - USgpm Industrial Process Equipment Group (IPEG) - 6823 Hazelwood Avenue BERKELEY, MO 53134 phone: 314-534-3100 - fax: 314-533-0022 www,ipegstl.com GRUNDFOS N stem 23.4.1 Project name : 88171 Consulting engineer Customer . INDUSTRIAL PROCESS ' EQUIPMENT GROUP Customer ref. / PO Quote Number / ID : 2159568 Date last saved : 29 Jan 2024 2:00 PM Nozzle Size (in.) Suction 5 iischarge 4 lion / Configuration VVear Ring Configuration Discharge Elbow Size Subplate Sump Depth (feet) Bearing Frame Bearing Frame Foot Bearing Type (Radial/Thrust) Bearing Lubrication Thrust Bearing ntermediate Bearing -ower Bearing Searing Housing Accessories 'ACO Construction Code Baseplate Drip Pan Coupling Guard Sealing Method Seal Material Packing Gland Lantern Ring Recirculation Lines Pump Baseplate Driver Estimated Shipping gross weight Nozzle Configuration I Pos'n 125#ANSI End 125#ANSI Top Horizontal Clockwise Single - Case In motor 1 ON6-40959-1 A0008-1931P Not Applicable Not Applicable Single Seal, Type 21S Buns Carbon Ceramic SS -Spring and Hardware None : 138.0 lb 8310 lb 971.0 lb Tag Number Service Model By (Sales Office) By (Sales Engineer) Frame Size Power RPM Enclosure Operating Power Supply Efficiency Service factor Motor Application Motor Options/Accessories Cord Length (feet) Case Motor Bracket Impeller Impeller Cap Screw and Washer Impeller Key Case wear ring Impeller wear ring Pump Shaft Shaft Discharge Pipe Discharge Elbow Suction Elbow Subplate iardware D Rings lump Coatings GDiI 40959 LC :1 INDUSTRIAL PROCESS EQUIPMENT GROUP John Needham Baldor : 365JMZ 100 hp 3600 rpm :ODP 230/460/3/60 Premium : 1.15 Suitable for Variable Speed Drive Cast Iron, ASTM A48 - Class 30 Cast Iron, ASTM-A48. CL 30 Stainless Steel, AISI-304 (1-1304) Stainless Steel, AISI-303 Stainless Steel, AISI 316 Tin Bronze, ASTM B584-90500 (618) Steel, AISI-1040 Bronze, 111932, C89835 Steel, Grade 5 Buna N Standard Manufacturer's Paint Industrial Process Equipment Group (IPEG) - 6823 Hazelwood Avenue - BERKELEY, MO 63134 phone: 314-534-3100 - fax: 314-533-0022 - www.1pegstl.com . m r o E O A w w m E a_ a 7 T � N m W w W W w O G N w N a E � r O Y ; c J aryp� Z O N m U) d z O 0 o » dd L x n ? -0 U W N = l r W �W _N L -•- W d I u. S` iCE1 c � O Z Q1 6 E h w m w Q C7 O a N r o e a n W E T m m • o O j ` LL N t6 • I- 4i fn d 'J 0 d d _ N r d/ WI♦ d e w e O V o i p '^ 0 i v'A/ Y/ = W oe e Lj > J L a U w j e M LL � d O V O ' U U M C•Z, L 0 rx r x Z `a LL =! a F V 3 0 o liii LL N N a n m O LL H O Z E a a E or � E w voi o ry C GRUNDFOS N Grundfos Quotation System 23.4.1 Project name : 88171 Tag Number : 001 Consulting engineer Service , Customer Model ; 40959 LC Customer ref. / PO Quantity : 1 Quote Number / ID : 2159568 Quoted By (Sales Office) : INDUSTRIAL PROCESS Date last saved : 29 Jan 2024 2:00 PM EQUIPMENT GROUP Stages : 1 Quoted By (Sales Engineer) : John Needham Performance Data Speed, rated Stage, Speed : 3550 rpm Limits Head, maximum diameter, rated flow : 344.8 ft Stages, maximum and Solids : 1 Head, minimum diameter, rated flow : 142.8 ft Stages, minimum : 1 Head, maximum, rated diameter : 275.2 ft Pump speed limit, maximum : 3600 rpm Efficiency adjustment factor, total : 1.00 Pump speed limit, minimum : 2500 rpm Power adjustment, total : 0.00 hp Curve speed limit, maximum : 3600 rpm Head adjustment factor, total : 1.00 Curve speed limit, minimum : 2500 rpm Flow adjustment factor, total : 1.00 Variable speed limit, minimum : 400 rpm NPSHR adjustment factor, total : 1.00 Solids diameter Iimtt : 0.75 in NPSH margin dictated by pump supplier : 0.00 It EnergyIndexes ER (CL) : 4 NPSH margin dictated by user ; 0.00 It NPSH margin used (added to'required' values) : 0.00 ft PEI (QL) 0.96 Mechanical Limits Typical Driver Data Torque, rated power, rated speed : 2.18 hp/100 rpm Driver speed, full load : 3560 rpm Torque, maximum power, rated speed : 2.22 hp/100 rpm Driver speed, rated load : 3569 rpm Torque, driver power, full load speed : 2.81 hp/100 rpm Driver efficiency, 100% load : N/A Torque, driver power, rated speed : 2.81 hp/100 rpm Driver efficiency, 75% load : N/A Torque, pump shaft limit : 3.61 hp/l 00 rpm Driver efficiency, 50% load : N/A Radial load, worst case . - Radial load limit Impeller peripheral speed, rated Impeller peripheral speed limit - Performance Various Data Flow (USgpm) Head(fit) Efficiency I%) NPSHr ft) Power Shutoff, rated diameter 0.00 268.1 - - 30.85 Shutoff, maximum diameter 0.00 383.6 - - 49.75 MCSF 409.7 273.5 58.34 7.93 48.49 Rated flow, minimum diameter 1,250.0 142.8 76.39 - 58.99 Rated flow, maximum diameter 1,250.0 344.8 83.23 - 131 BEP flow, rated diameter 1,088.6 224.6 83.32 14.86 74.07 120% rated flow, rated diameter 1,500.0 145.6 70.17 29.76 78.59 End of curve, rated diameter 1,522.4 139.5 68.42 31.00 78.36 End of curve, minimum diameter 1,490.6 94.29 61.16 29.24 58.01 End of curve, maximum diameter 1,548.1 282.7 77.63 32.50 142 Maximum value, rated diameter - 275.2 83.362 - 78.86 Maximum value, maximum diameter - - 83.26 - 142 System differential pressuro :, Density,Density, Differential pressure, rated flow, rated diameter (psi) 86,62 86.62 Differential pressure, shutoff, rated diameter (psi) 116.0 116.0 Differential pressure, shutoff, maximum diameter (psi) 166.0 166.0 Discharge pressure @ Suction @ Suction @ Suction @ Suction pressure, Discharge pressure, rated flow, rated diameter (psi.g) rated pressure, max 86.62 86.62 pressure, rated pressure, 86.62. max 86.62 Discharge pressure, shutoff, rated diameter (psi.g) 116.0 116.0 116.0 116.0 Discharge pressure, shutoff, maximum diameter (psi.g) 166.0 166.0 166.0 166.0 Maximum flow / rated flow, rated diameter : 121.79 % Head rated diameter / head minimum diameter, rated flow : 140.18 % Impeller Material : SS Impeller Construction Motor Phase & Voltage : Three Phase, 2301460V Motor Enclosure : ODP Industrial Process Equipment Group (IPEG) 6823 Hazelwood Avenue • BERKELEY, MO 63134 phone: 314-534-3100 fax: 314-533-0022 www3pregstl.com Product Overview ACQ580 The ACQ580 is the latest addition to the ABB drives portfolio. This robust, compact and energy efficient drive is designed for securing the flow of water and wastewater in your pumping system. Secure the flow The ACQ580 variable frequency drive (VFD) delivers innovative pumping features for the water and wastewater industry. Primary Setting menu and assistants simplifies commissioning, setup and daily control. Embedded water and wastewater application features create an intuitive environment for users and dedicated pumping features enhance the performance of the pumping system. Speakthelanguage Leveraging clear, water industry terminology, the control panel enables operators to efficiently interface with the drives in terms they use every day. The optional Bluetooth control panel allows for wireless commissioning and monitoring. Feel the Power ACQ580 drives are designed for customers who value reliability, high quality, and robustness. With embedded pump functionality, the ACQ580 keeps the pump system operating optimally and efficiently. Product features, such as coated boards and optional compact UL Type 12 enclosures, make the ACQ580 suitable for harsh conditions. All ACQ580 drives are current rated devices. The HP ratings provided are for reference only and are based on typical 4-pole motors at nominal voltages (NEC Table 430.250). If full motor torque is required, ensure the drive has a continuous current rating equal to, or greater than the full load amp rating of the motor. The ACQ580 is available in both normal and heavy-duty rafings. Normal duty ratings provide a 110% short term overload rating for one minute every ten minutes. Heavy duty ratings provide a 150% short term overload rating for one minute every ten minutes. All ACQ580 drives and their protective functions are thoroughly tested for optimal performance. _f I Control panel features The ACQ580 Assistant Control Panel features: • An intuitive interface Primary Settings menu to simplify drive commissioning A real Time Clock • Diagnostic and Maintenance functions A full graphic display, including chart, graph, meter options • 21 editable home views • A USB interface for PC and tool connection Alpha -numeric parameters A choice of 14 languages A dedicated Help key • Four user sets The ability to store parameters in control panel memory for later transfer to other drives or for backup of a particular system. A back-up and restore feature - Parameters and/or motor data - Automatic back-up two hours after parameter change A modified parameter display - Creates unique short menu - Shows parameters that differ from default Feature overview Water Application Functions Intelligent multi -pump control Quick ramps Sleep boost Auto change Level control Soft pipe fill Sensorless flow calculations Pump cleaning Pump priority Two independent adjustable accel/decel ramp Two or three wire start/stop control Motor preheating PID controllers for motor and process Motor flying start Process PID control Coast to stop Ramp to stop Real-time clock (scheduling) Run permissives Start interlock delayed start PID controller parameters PID sleep / wake-up Set point controllers (process and external) Dry pump protection Dry run protection Pressure protection Inlet pressure protection Maximum pressure protection Minimum pressure protection Flow protection Start-up assistants Primary settings for ease of use Sophisticated process control Energy optimizer and calculator Diagnostic assistant Built-in and stand-alone process control PID loop Load profile Adaptive programming Motor control features Scaler (V/HZ) and vector control Motor ID run U/F ratio — Linear — Squared Energy optimization IR compensation Slip compensation Critical frequency lockout bands Flux braking Communication Protocols Standard Modbus RTU (EIA-485) Available optional protocols: — Ethernet I/P — DeviceNet — Modbus TCP — Profbus-DP PROFINET Control panel functions / features First start assistant Primary settings for WM/W applications Hand -Off -Auto operation Full -graphic and multi-lingual display Parameters are alpha -numeric 21 editable home views Four user sets Dedicated Help key Backup/restore (read/write) of parameters and motor data Automatic back-up two hours after parameter change Parameters stored in control panel memory Standard USB interface for PC and tool connection Operating data display: — Output frequency (Hz) — Speed (RPM) — Motor current (A) — Calculated % motor torque — Calculated motor power (kW) — DC bus voltage (V) — Output voltage IV) — Heatsink temperature — Elapsed time meter (resettable) — kWh (resettable) — Input / Output terminal monitor — PID actual value (feedback) — Error fault text — Warning text — Three scalable process variable displays — Real-time clock — User -definable engineering units Modified parameter display — Creates unique short menu — Shows parameters that differ from default Diagnostic and maintenance functions Supports 14 languages Protective Functions At Supervision Overvoltage Undervoltage Drive temperature Earth (ground) fault detection Emergency stop Local control loss detection Motor phase loss detection Overcurrent protection Overspeed protection Safe Torque Off detection Short circuit Stall protection Supply phase loss detection Swapped supply and motor cabling Motor overtemperature protection (UL508C) Input and Output switch supervision Underload supervision Overload supervision Loss of reference Panel loss External events Current limit regulator TransienU surge protections (MOV and Choke) Control terminals Default 1/0 connections This is the default configuration of control connections for water and wastewater applications. Default control connections for water applications 1...10 max. 5000 28 B+ 30 A- Embedded field us, EFB (EIA-485) 31 DGND S4 TERM Termination switch S5 BIAS I Bias resistors switch X4 Safe toraue off 34 36 OUT1 OUT2 Safe torque off. Factory connection. Both circuits must be closed for the drive to start. See chapter "The Safe Torque Off Function" in the Hardware manual of the drive. 36 SGND 37 IN1 38 IN2 Safe toraue off ny: txt. 44v AUNU Input to power up unit when the main suoDiv Is disconne Technical specifications connection Voltage and power range Input voltage (1.13) ACQ580-01-xxxA-2 208-240 V AC0580-01-xxxA-4 440-480 V ACQ580-01-xxxA-6 525-600 V Input voltage tolerance _ 10%/-15% Line Limitations Max±3% of nominal phase to phase input voltage_ Power Factor (cos (D) at nominal load - - ACQ580-01 I --_ - Efficiencyatat rated power ACQ580-01 98% Power Loss Approximately 2-3%of rated Motor connection Supported motor control Scalar and vector Supported motor types Asynchronous motor, permanent magnet motor _ (vector), SynRM (vector) Voltage 3-phase, from 0 to supply __. voltage_ Frequency _ _ 0 to 500 Hz ShortTerm Overload Capacity _ 110%for 1 min/10min Variable Torque Peak Overload Capacity 1.35 for 2 second Variable Torque (2 sec /l minute) Switching Frequency 2, 4, 8 or 12 kHz (Up to 150 Hp); 1 or 4 kHz (Over 150 Hp), Automatic fold back in case of overload Acceleration/Deceleration Time 0 to 1800 s _ Short Circuit Current Rating 100 kA (UL) with fusing External power supply ACQ580-01, R6-R9: Standard 1.50 A at 24 V AC/DC t10%/36W ACQ580-01, R1-R5: Optional card 1.04 A at 24 V AC/DC ±10%/ 25W Safety Safe Torque Off (STO) STO Standard Input 17 .30 VDC, 55MA Degree of Protection Degree of protection (IEC/EN 60529) ACO580-01 IP21, IP55 Enclosure types (1.11-508C/61800-5-i) ACQ580-OS UL (NEMA) Type 1 & 12 Inputs and outputs 2 analog inputs Selection of Current/Voltage Input mode is user programmable. Voltage reference _ _ _ 0 (2) to 10 V, Rin > 200 k0 Current reference 0 (4) to 20 mA, Rin =100 0 Potentiometer reference 10 V ±1% Max. 20 MA value 2 analog outputs AO1 Is user programmable, for current or voltage. AO2 current Voltage reference 0 to 10 V, Riwa: > 100 kO Current reference 0 to 20 MA, Ri.: <500 0 Applicable potentiometer_ _ 1 k0 to 10 kO Internal auxiliary voltage 24 V DC±10%, max. 250 MA Accuracy +/-1%full scale range at 25°C (77-F) Output updating time 2 ms 6 digital inputs 12 to 24 V DC, 10 to 24 V AC, Connectivity of PTC sensors supported by a single digital input. PNP or NPN connection (5 Dls with NPN connection). Programmable Input Updating Time 2 ms 3 relay outputs Maximum switching voltage 250 V AC/30 V DC. Maximum continuous current 2 A Mrs. Programmable, Form C Contact material _ Silver Tin Oxide (AgSnoz) PTC, PT100 and PT3000 Any of the analog Inputs, or digital input 6, are configurable for PTC with up to 6 sensors. Adjustable filters on analog inputs and outputs All control Inputs Isolated from ground and power Operation Air Temperature -15 to+40°C(5 to 104 OF) 50-C (122^F) available with derate 0 to -15 °C (32 to 5 OF) No Frost Allowed Output derated above +40°C (104°F) Installation site Altitude 0 to 1000 m (3281 ft) above sea level Output derated above 1000m (3281 it) up to 4000m (13123ft) Relative Humidity 5 to 95% No condensation allowed Maximum relative humidity Is 6091 in the presence of corrosive gasses Atmospheric pressure 70 to 106 kPa (101 to 15.4 PSI) 0.7 to_1.05 atmospheres Vibration Risk category IV Certified (IBC Environmental protections Chemical Gasses Class 3C2(UL Type 1,IP21) Class 3C2 (UL Type 12, IP55) _ Note: Conformal coated PCBs Solid Particles Class 352 No conductive dust allowed Pollution degree Pollution degree 2 (IEC/EN 61800-5-1) Product Compliance Standards and directives Low Voltage Directive 2006/95/EC EMC Directive 2004/308/EC 60721-3-3: 2002 60721-3-1:1997 Quality assurance system ISO 9001 and Environmental system ISO 14001 CE, UL, cUL, CSA and EAC approvals Galvanic Isolation accordingto PELV RoHS2 (Restriction of Hazardous Substances) EN 61800-5-1: 2007; IEC/EN 61000-3-12; EN 63800-3: 2017+Al: 2012. Category C2 (1st environment restricted distribution); Safe torque off (EN 61800-5-2) Seismic (IBC, OSHPD) - Coming 2019 EMC Class C2 (1st environment, (according to EN61800-3) restricted distribution) Available Options External 24V AC/DC and digital 1/0 extension (2xRO and 1xDO) (CMOD-01) Additional 115/230 V Digital Input_ (6xDl and 2xRO) (CHDI-01) Fieldbus Adapter Modules EtherNet/IP, Modbus TCP, PROFISUS-DP, PROFINET, DeviceNet Operation, Programming and Drive Composer Pro Entry Diagnostic Tool _ Cold configuration tool (CCA-OS) Keypad Standard Hand/Off/Auto Optional Bluetooth Storage (in Protective Shipping Package) Air Temperature -40 to+70°C(-40 t_o_+1587) Relative Humidity _ Less than 95% No condensation allowed Maximum relative humidity is 60% in the presence of corrosive gasses Chemical Gasses Class SC2 Solid Particles Class 1S2 Contact ABB regarding Class iS3 Atmospheric pressure 70 to 106 kPa _ 0.7 to 1.05 atmospheres_ Vibration (ISTA) _ R1...R4 In accordance with ISTA SA IRS ... R9 In accordance with ISTA 3E Transportation (in Protective Shipping Package) AIr Temperature -40 to 70-C(-40 to 158°F) Relative Humidity Less than 95% No condensation allowed Maximum relative humidity is 60% in the presence of corrosive gasses Atmospheric Pressure 60 to 106 kPa (8.7 to 15.4.PSI) 0.6 to 1.05 atmosphere_ s Free Fall Ri: 76 cm (30 in) R2: 61 cm (24 in) 113: 46 cm (18 in) R4: 31 cm (12 in) R5: 25 cm (10 in_) Chemical Gasses Class 2C2 Solid Particles Class 252 Shock/ Drop (ISTA) R1.... R4 In accordance with ISTA IA RS.... R9 In accordance with ISTA 3E Vibration (ISTA) R1....R4 RS....R9 Type designation: ACQ580 — XX — Product Series Type and Construction - 01: Wall mounted, UL Type 1 (IP 21), conduit box Output Current Rating - See tables below: • 240V 3-phase: Table 1 • 240V 1-phase: Table 2 • 480V 3-phase: Table 3 • 575V 3 phase: Table 4 Voltage - 2: 208/240V - 4: 480V - 6: 575V 6056: NEMA 12 (IP 55) enclosure Table 1 —x+ Type In ut Out ut s Heat CQ5 1 - current T 0/max ILd PLd ,r 3-phase U1 = 200...240 V, Pn at UN = 208/230 V, 60 Hz 04A6-2 4.6 6.3 4.6 1.0 155 45 25 R1 06A6-2 6.6 8.9 6.6 1.5 187 55 25 R1 07A5-2 7.5 11.9 7.5 2.0 224 66 25 R1 10A6-2 10.6 14.3 10.6 3.0 288 84 25 R1 017A-2 16.7 22.6 16.7 5.0 454 133 25 R1 024A-2 24 32.7 24.2 7.5 593 174 59 R2 031A-2 31 43.6 30.8 10 777 228 59 R2 046A-2 46 62.4 46.2 15 1100 322 105 R3 059A-2 59 83.2 59.4 20 1469 430 105 R3 075A-2 75 107 74.8 25 1791 525 170 R4 088A-2 88 135 88 30 2114 619 82 R5 114A-2 114 158 114 40 2852 835 82 R5 143A-2 143 205 143 50 3535 1035 256 R6 169A-2 169 257 169 60 4272 1251 265 R7 211A-2 211 304 211 75 5194 1521 265 R7 273A-2 273 380 273 100 7039 2061 324 R8 Table 2 1- lill A hp 1-phase U1 = 240 V, Pn at UN = 230 V, 60 Hz 04A6-2 1 3.3 2.2 0.5 R1 06A6-2 1 4.6 3.2 0.75 R1 07A5-2 1 6.3 4.2 1.0 R1 10A6-2 8.9 6.0 1.5 R1 017A-2 11.8 6.8 2 R1 024A-2 17.3 9.6 3 R2 031A-2 30.4 15.2 5 R2 046A-2 42 22 7.5 R3 059A-2 55 28 10 R3 075A-2 55 28 10 R4 088A-2 81 42 15 R5 114A-2 111 54 20 R5 143A-2 137 68 25 R6 169A-2 153 80 30 R7 211 A-2 2 99 004 40 R7 273A-2 258 130 50 R8 Table 3 .• Output ratinqs Heat dissipation 14CQ580 0��� 3-phase U1 = 440...480 V, P� at UN = 460 V, 60 Hz 02A14 2.1 2.9 2.1 1.0 155 45 25 R1 03AO-4 3.0 4.1 3.0 1.5 187 55 25 R1 03A5-4 3.5 5A 3.5 2.0 224 66 25 R1 04A8.4 4.8 6.5 4.8 3.0 288 84 25 R1 06AO-4 6.0 8.6 6.0 3. 3362 106 25 R1 07A6-4 7.6 10.8 7.6 5.0 454 133 25 R1 012A-4 12.0 15.3 12.0 7.5 593 174 25 R1 014A-4 14.0 21.6 14.0 10.0 777 228 59 R2 023A-4 23.0 30.5 23.0 15.0 1100 322 59%R5 027A-4 27.0 41.4 27.0 20.0 1469 430 105 034A-4 34.0 48.6 34.0 25.0 1791 525 105 044A-4 44.0 61.2 44.0 30.0 2114 619 105 052A-4 52 79 52 40 2852 835 79 065A-4 65 94 65 50 3497 1024 79 077A-4 77 117 77 60 4235 1240 79 078A-4 77 117 77 60 4235 1240 82 096A-4 96 139 96 75 5157 1510 82 11 124A-4 1 124 1 173 1 124 1 100 1 5041 1476 256 R6 156A-4 156 223 156 125 6748 1976 265 R7 180A4 180 281 180 150 8012 1 2346 265 R7 240A-4 240 324 240 200 11393 3336 324 R8 260A 4 260 418 260 200 13442 1 3936 324 R8 302A-4 302 468 302 250 16516 1 4836 677 R9 361A-4 361 542 361 300 16516 1 4836 677 R9 414A-4 414 542 414 350 20614 1 6036 677 R9 Table 4 Output ratings ��� 131hals!e!Ul500...600 V, Pn at UN = 575 V, 60 Hz 2.7 4.3 2.7 2.0 224 66 59 R2 3.9 5.3 3.9 3.0 288 84 59 R2 6.1 8.2 6.1 5.0 454 133 59 R2 9.0 12.2 9.0 7.5 593 174 59 R2 011A-6 11.0 16.2 11.0 10 777 228 59 R2 017A-6 17.0 23.0 17.0 15 1100 322 59 R2 022A-6 22 30.6 22 20 1469 430 105 R3 027A-6 27 39.6 27 25 1791 525 105 R3 032A-6 32 48.6 32 30 2114 619 105 R3 041A-6 41 58 41 40 2852 835 82 R5 052A-6 52 74 52 50 3497 1024 82 R5 062A-6 62 94 62 60 4235 1240 82 R5 077A-6 77 112 77 75 5157 1510 82 R5 099A-6 99 139 99 100 7039 2061 265 R7 125A-6 125 178 125 125 8422 2466 265 R7 144A-6 144 225 144 150 10266 3006 324 R8 192A-6 192 259 192 200 13954 4086 677 R9 242A-6 242 346 242 250 16721 4896 677 R9 271A 6 271 411 271 250 16721 4896 677 R9 ..terminals I ire ran e Wire range ®� 3-phase U1 = 200...240 V, Pn at UN = 208/230 V, 60 Hz R1 1 30 24 10 1.0 18 6 1.1 R2 1 30 20 1 6 1.5 18 6 1.1 R3 1 30 20 2 3.5 18 2 1.1 R4 1 45 20 1 4.0 18 2 2.1 R5 1 45 10 2/0 5.6 2 2F 1.6 R6 1 45 4 300 MCM 30 2 2 7.2 R7 1 54 3/0 500MCM 40 2 2 7.2 R8 2 45 2x1/0 I 2x300MCM 40 2 2 7.2 3-phase U1 = 440...480 V, Pn at UN = 460 V, 60 Hz 131 1 1 1.18 1 24 10 0.7 18 6 1.1 R2 1 1 1.18 20 6 1.1 18 6 1.1 R3 1 1.18 20 2 2.6 24 2 1.1 R4 1 1.77 20 1 3.0 12 2 2.1 R5 1 1.77 10 2/0 4.1 2 2 1.6 R6 1 1.77 4 300 MCM 22.1 2 2 7.2 R7 1 2.13 3/0 500 MCM 29.5 2 2 7.2 RS 2 1.77 2x1/0 2x300 MCM 29.5 2 2 7.2 R9 2 2.13 2x3/0 2x500 MCM 51.6 2 2 7.2 3-phase U1 = 500...600 V, Pn at UN = 575 V, 60 Hz R2 1 30 20 6 1.5 18 6 1.1 R3 1 30 20 2 3.5 18 6 1.1 R5 1 45 10 2/0 5.6 2 2 1.6 R7 1 54 3/0 500 MCM 40 2 2 7.2 R8 2 45 2x1/0 2x300MCM 40 2 2 7.2 R9 2 54 2x3/0 2x500 MCM 70 2 2 7.2 +) Maximum cable diameter accepted. For the lead -through plate hole diameters, see chapter Dimension drawings on page 301. I> Either cable lug, not provided (R5, see page 179) or cable clamp (R6... R9, see page 184) is used for grounding. 3) Note: Minimum wire size does not necessarily have enough current capability for full load. Make sure the installation complies with local laws and regulations. BOARD OF PUBLIC WORKS AGENDA ITEM REVIEW REQUEST FORM Date: 11-05-2024 Name: Jacob M. Klosinski Department of Public Works — Engineering Division BPW Date: 11-12-2024 Phone Extension: 9496 Required Prior to Submittal to Board BPW Attorney X Attorney Name Michael Schmidt Dept. Attorney ® Attorney Name Michael Schmidt Purchasing ® Mickey Low / Ron O'Connor Check the Appropriate Item Type — Re uired or All Submissions ❑ Professional Services Agreement ❑ Contract ❑ Proposal ❑ Open Market Contract ❑ Amendment/Addendum ❑ Special Purchase, QPA ❑ Bid Opening ❑ Bid Award ❑ Req. to Advertise ❑ Title Sheet ® Quote Opening ❑ Quote Award ❑ Reject Bids/Quotes ❑ Proposal Opening ❑ C/O & PCA No. ❑ PCA ❑ Chg. Order, No. ❑ Traffic Control ❑ Resolution ❑ Other: ❑ Ease./Encroach Reauired Information Company or Vendor Name New Vendor ❑ Yes[] If Yes, Approved by Purchasing ❑ No MBE/WBE Contractor ❑ MBE Completed E-Verify Form Attached ❑❑ Nos Project Name 124-058 Locust Water Booster Pump Station Improvements Project Number PROJ- ; PR - Funding Source Water Works — Water Capital Account No. 642-06-605-514-442005 Water Works Amount Terms of Contract Special Contract Provisions Purpose/Description The Division of Engineering and Division of Water requests the Board of Public Works open competitive quotes for the Locust Water Booster Pump Station Improvements at its 11-12-2024 Board Meeting. This project includes the installation of one water booster pump, variable frequency drive, PLC, HMI and ro rammin . For Change Orders Only Amount of ❑ Increase $ ❑ Decrease ($ ) Previous Amount $ Current Percent of Change New Amount Total Percent of Change: Time Extension Amount: Increase Decrease Increase % Decrease ( % New Completion Date: INTER -OFFICE MEMORANDUM DEPARTMENT OF PUBLIC WORKS DIVISION OF ENVIRONMENTAL SERVICES TO: Members of the Board of Public Works Michael Schmidt, Assistant City Attorney Public Works Theresa Heffner, Clerk of the Board of Public Works FROM: Jacob M. Klosinski, P.E., Assistant City Engineer SUBJECT: Agenda Request — Professional Services 124-058 Locust Water Booster Pump Station Improvements (PROJ# ; PR# DATE: November 5, 2024 The Division of Engineering and Division of Water Works request the Board of Public Works open and received public quotations for the Locust Water Booster Pump Station at its Regular Meeting on November 12, 2024 Background The City of South Bend Department of Public Works, Division of Engineering, and Division of Water Works have been working with Donohue & Associates to provide an improved pumping configuration for the Locust Water Booster Pump Station. Since the pump station was built, the impact of the pump station has resulted in very little impact to the water distribution system because the pumps that are in the booster station are not able to effectively overcome of the head pressures or pipe restrictions in the water distribution system to provide any significant improvements to pumping in this area of the City. This is partly due to the pump selection by the initial designer and partly due to pipe size restrictions in this area of the water distribution system that results in friction losses. Please note that a project is being added to DFO by the financial officer so the project can be tracked. A purchase requisitions will be entered once quote award has been confirmed post -bid review. Funding for this project was provided through Water Works Capital — Capital, Account 622-06-604-620-442010. For questions regarding the subject Agenda Request, contact Jacob M. Klosinski (Ext. 9496) at the Division of Engineering. BOARD OF PUBLIC WORKS AGENDA ITEM REVIEW REQUEST FORM Date: 11-14-2024 Name: Jacob M. Klosinski Department of Public Works — Engineering Division BPW Date: 11-26-2024 Phone Extension: 9496 Required Prior to Submittal to Board BPW Attorney X Attorney Name Michael Schmidt Dept. Attorney ® Attorney Name Michael Schmidt Purchasing ® Mickey Low / Ron O'Connor Check the Appropriate Item Type — Required. for All Submissions ❑ Professional Services Agreement ❑ Contract ❑ Proposal ❑ Open Market Contract ❑ Amendment/Addendum ❑ Special Purchase, QPA ❑ Bid Opening ❑ Bid Award ❑ Req. to Advertise ❑ Title Sheet ❑ Quote Opening ® Quote Award ❑ Reject Bids/Quotes ❑ Proposal Opening ❑ C/O & PCA No. ❑ PCA ❑ Chg. Order, No. ❑ Traffic Control ❑ Resolution n Other: n Ease./Encroach Company or Vendor Name New Vendor MBE/WBE Contractor Project Name Project Number Funding Source Account No. Amount Terms of Contract Special Contract Provisions Purpose/Description Information Solutions Midwest, Inc. U YesU If Yes, Approved by Purchasing ❑ No ❑ MBE Completed E-Verify Form Attached ❑ Yes ❑ WBE ❑ No Locust Water Booster Pump Station Improvements 124-058 / PROJ-00000582 / PR-00037523 Water Works Capital 622-06-604-620-442010 $13 8,223.00 Base Bid (Lump Sum and Unit Prices) None The Division of Engineering and Division of Water recommends the Board of Public Works award the subject quotation to Engineered Solutions Midwest, Inc. as the lowest, responsive, responsible bidder at its 11/26/2024 meeting. For Change Orders Only Amount of ❑ Increase $ ❑ Decrease ($ ) Previous Amount Current Percent of Change New Amount Total Percent of Change: Time Extension Amount: New Completion Date: Increase % Decrease ( %) Increase % Decrease ( %