Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1316 East Wayne Street_AA 2024-0903
Sarah Andrews, President HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY CERTIFICATE OF APPROPRIATENESS The Historic Preservation Commission of South Bend and St. Joseph County has approved the following work: Install 13 solar panels mounted flush on south-facing roof section. Advanced Solar Distribution, Contractor for the following location: 1316 WAYNE ST South Bend, IN, 46615 East Wayne Street Application No. 2024-0903 in the County of St. Joseph; State of Indiana; which is: Located in a Local Historic District A Local Historic Landmark and found this application to be appropriate according to the Standards pertaining to Local Historic Landmarks and/or Local Historic Districts. Regulations pertaining to the Historic Preservation Commission are found in Chapter 21 (Zoning), South Bend Municipal Code and Chapter 26 of the St. Joseph County Code. The issuance of this certificate does NOT in any manner, release the recipient from the responsibility of complying with the requirements of the zoning ordinances, building codes, safety codes, ADA or other requirements of the City of South Bend, the County of St. Joseph, the State of Indiana, or the United States Federal Government. This certificate is good for one year from the date of issuance and is effective from the date entered herein. Plans are on file and open for public inspection at the office of the Historic Preservation Commission of South Bend and St. Joseph County, 227 West Jefferson Blvd., Suite 1400 S, South Bend, Indiana, during normal business hours. THIS CERTIFICATE IS NOT TRANSFERABLE NAME OF APPLICANT:Jonathan MacArt CERTIFICATE ISSUED BY: Kate Himick Historic Preservation Specialist POST IN A CONSPICUOUS PLACE ON THE STREET SIDE OF THE PROJECT UNTIL COMPLETION OF ALL WORK. Phone: (574) 235-9371 E-mail: SBSJCHPC@southbendin.gov ROSS VAN OVERBERGHE Historic Preservation Administrator 9/4/2024DATE CERTIFICATE TAKES FORCE:9/4/2025DATE CERTIFICATE EXPIRES: Ord No. 7796-87 East Wayne Street ADMINISTRATIVE APPROVAL Tuesday, September 3, 2024 Application for Cer tificate of Appropriateness Important Information Regarding this Request REQUIRED DOCUMENTATION AND SITE PLANS The Historic Preservation Commission of South Bend and St. Joseph County cannot process an Application without required documentation. Comprehensive documentation provides a complete understanding of the project. Problems often occur during a project review or during the execution of the project when the property owner, staff or commissioners are unclear as to project specifics. Applications will NOT be processed without required documentation. Photographs may be submitted in digital format or in photographic print. When a project involves blueprints and/or site plans, one (1) set shall be submitted with the Application. Any documentation submitted to this office cannot be returned to the applicant. APPLICATION FEE The application processing fee for any Application for a Certificate Of Appropriateness is $20 Payment must accompany the application at the time of submission. For an electronically submitted application, payment must reach the HPC office within 48 hours following transmission. Payment can be made by credit card by contacting Business License Administrator Michelle Adams at (574) 235-5912; by cash in person in the Department of Community Investment on the 14th floor of the County City Building; or by check made out to City of South Bend. Applications will NOT be processed without the required fee. MEETING ATTENDANCE When an Application has been scheduled for any meeting, the owner, architect or contractor(s) retained for the project shall attend the meeting where their project will be reviewed and a decision rendered. Failure by the owner, architect, or contractor to attend such meetings may result in denial of the Application due to insufficient representation. CERTIFICATE ISSUANCE Certificates of Appropriateness will be filed with the Building Department of South Bend and St. Joseph County. A copy of the Certificate will be emailed directly to the owner and/or contractor(s) listed on the application. INSPECTION AUTHORITY All projects will be inspected during and following execution for compliance with the decision(s) rendered by the Historic Preservation Commission of South Bend and St. Joseph County. Owner acknowledges that while the Historic Preservation Commission only considers Certificates of Appropriateness for exterior features, under certain circumstances it may be necessary for the Commission Staff to have access to the interior of the building in order to accurately assess the condition of the exterior feature and that the lack of access to the interior may prevent the Commission Staff from making a favorable recommendation. Any work performed on a historic landmark or in an historic district which does not conform to the Certificate of Appropriateness certificate shall be immediately halted by the Historic Preservation Commission and the Building Department of South Bend and St. Joseph County. Fines may be levied for projects not in compliance. I read and understand the information above:Yes, Continue Date Tuesday, September 3, 2024 1 Proper ty Information Property Address for Proposed Work:1316 East Wayne St. S. Property City South Bend Property Zip Code 46615 Property Owner Information:Jonathan MacArt Owner Email Owner Address Same as above Proposed Work and Project Information All projects must comply with applicable building and zoning codes. South Bend Zoning Ordinance St. Joseph County Zoning Ordinance Contractor Information Advanced Solar Distributor Solar John Moorman Contractor Phone Number (574) 227-2801 Contractor Email johnm@advancedsolarllc.com Description of Proposed Work: Install 13 solar panels mounted flush on south-facing roof section. Install solar power inverter inside house. Specification of Material via Manufacture Brochure:PDF Dark-phenex-….pdf PDF Flush_Mount….pdf PDF se-home-hub….pdf File Upload Site Plans, Aerial Views, and/or Blueprints: One (1) set shall be submitted with the Application. Uploaded documentation must show existing property lines, buildings, structures, and proposed project location(s). Hand Drawn Plans/Elevations are ok Photographs to include: each area affected by project, close up detail of project areas. Windows, Siding, and/or Door projects must include photographs of each window/door/siding affected by the project and detailed close up of condition Applications will not be processed if the required photographs and/or documentation are not 2 included. Any documentation submitted to this office cannot be returned to the applicant. Quote/Evaluation(s) by Repair Professional (Optional): PDF ASD Res - Jonathan MacAr ….pdf Photographs: PDF site-view-1316-wayne.pdf I have included all required photographs and documentation for my application, as described above. I understand these items will not be returned. I Affirm Signature of Proper ty Owner: Payment Invoice ID # INV-000066 Payment Method Pay via Check in Mail 3 1 12 2 3 3 Proposed System Location 4 4 Pricing Details Your System Design (13) Philadelphia Solar (1) SolarEdge 5.20 kW DC 6.88 MWh 92.08% 82.55% Modules Inverters System Size Annual Energy Production Energy Offset Utility Bill Offset Upfront System Pricing: 30% Federal Tax Credit: Net System Cost Taxes not Included Site Evaluation Required to Finalize Estimate I-V CURVES Module : PS-M108(HCBF)-xxxW Half-Cell Mono-Crystalline 10BB Black modules with power up to 410 Wp are produced using the state-of-the-art (automated) robotic production lines. �ese modules are suitable to be used for most electrical power applications and have excellent durability to prevailing weather conditions P Type/M10/PERC/10BB/Half-Cell Lower microcrack problem loss comparing with 5-busbar module Light weight , Perfect for Residential Roof-top Strong Mechanical Load Capacity Better temperature coecients come from half-cell design. Excellent anti-PID performance to ensure module’s stable power output 25 Years - 86.0 % %100 %98 %92.5 %86.0 1 12 25 End of Year LINEAR PERFORMANCE WARRANTY FEATURES PID Bifacial 400-410W DARk Current-Voltage Curve Power-Voltage & Current-Voltage Curve 1000W/m2 600W/m2 200W/m2 800W/m2 400W/m2 25 Years Product Warranty 25 Year Linear Power Warranty Only -0.5% Annual Degradation On-Grid Commercial/Industrial Roof-Tops (Including Lighting Systems) O-Grid Systems On-Grid Residential Roof-Tops Solar Power Plants APPLICATIONS Made In Jordan IEC 62782:2016 Dynamic loadIEC TS 62804 PID Resistance IEC 60068 Dust and Sand Resistance IEC 62716 Ammonia Resistance IEC 61701 Salt Mist Resistance UL 61215 / UL 61730IEC 61215 / IEC 61730 IEC 61853 PAN FileBankability Report EN ISO 9001: 2015Quality Management System EN ISO 14001: 2015Environmental Management SystemEN ISO 45001: 2018 Occupational health and safety management systems CERTIFICATIONS POWER AT STC ELECTRICAL CHARACTERISTICS 410W Short Circuit Current - Isc (A) Maximum Power Current - Impp (A) Open Circuit Voltage - Voc (V) Maximum Power Voltage - Vmpp (V) Module E�ciency - ’ (%) 13.66 13.01 37.55 31.52 21.0% Bifaciality Ratio (%) 65±5% 400 W 13.55 12.92 37.15 31.00 20.5% 405 W 13.59 12.96 37.34 31.27 20.8% Values at Standard Test Conditions STC (Air Mass AM 1.5 , Irradiance 1000 W/m2 , Cell Temperature 25o C). PHYSICAL CHARACTERISTICS Module Dimensions (mm)1721±1 x 1133±1 x 30 Module Weight (kg) Modules per Pallet Max Static load (Front) Max Static load (Back) Dynamic load 5400 Pa 5400 Pa 1000 Pa 40 Feet High-Cube Container 20.5 ± 1kg 37 962 Modules Packaging Characteristics Value Mechanical Load** Value Value Front Surface Encapsulant Back Cover Frame MATERIAL CHARACTERISTICS Characteristics Value Junction Box Cable Length Fire Classification 108 (54x 2) Grade A - Mono PERC Crystalline Silicon/10 BB 182x91mmCell Type 3.2mm Tempered AR Coated Glass PID Free EVA Transparent Backsheet Type I Anodized Aluminum (Black) Cables Length Could be 300mm, or 1200mm With Original MC4 Connector Cells per Module IP68 , 3 Bypass Diodes Power Temperature Coe�cient PMP (%/C°)-0.35 THERMAL CHARACTERISTICS Characteristics Value NOCT (°C) 45±2 Open Voltage Temperature Coe�cient VOC (%/C°)-0.22 Short Circuit Current Temperature Coe�cient ISC (%/C°)+0.05 Power measuring tolerance: ± 3%, other measurements tolerances: ± 5%. Datasheet is subjected to change without prior notice, always obtain the most recent version of the datasheet. ** Caution: For professional use only, the installation and handling of PV modules and cleaning modules require professional skills and should only be performed by qualified professionals, please read the Installation and Operation Manual before using the modules, also Cleaning Guidelines OPERATING CONDITIONS Maximum Sytem Voltage - Vmax (V) Maximum Series Fuse (A) Operating Temperature Range (°C) 25 1500 IEC: -40 to +85 UL: -40 to +90 MODULE DRAWINGS Updated FEB 2024 XR Flush Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Assistant Online software makes it simple to create, share, and price projects. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. 25-Year Warranty Products guaranteed to be free of impairing defects. Built for solar’s toughest roofs. IronRidge builds dependable systems for mounting solar on homes. XR Rail® components have been tested to the limit and proven to endure extreme environments, including Florida’s high-velocity hurricane zones. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully-certified, code-compliant and backed by a 25-year warranty. Datasheet © 2023 IronRidge, Inc. All rights reserved. U.S. Patents: #8,695,290; #9,819,303; #9,865,938; Others Pending. Version 2.00 XR Rails® Attachments Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear and black finish BOSS® Bonded Splices Bonded Structural Splices connect XR Rails together. • Integrated bonding • No tools or hardware • Self-centering stop tab XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear and black finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish Replace tiles and ensure superior waterproofing. • Flat, S, & W tile profiles • Form-fit compression seal • Other tile hooks available Knockout Tile Clamps & Grounding UFO® Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish CAMO Bond modules to rails while staying completely hidden. • Universal end-cam clamp • Tool-less installation • Fully assembled Endorsed by FL Building Commission Flush Mount is the first mounting system to receive Florida Product approval for 2017 Florida Building Code compliance. Learn More at bit.ly/floridacert Flash, then mount rails with fast and nimble installation. • Fits between roofing nails • Easily align pilot holes • 360° orientation FlashVue® Bonding Hardware Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16” socket • Assembled and lubricated HUG™ Halo UltraGrip™ Advanced flashing system adheres to top of shingles. • Foam-backed mastic seal • Multi-tiered waterproofing • Rafter and deck options FlashFoot2® Flash, then mount rails with our classic, robust design. • Twist-on Cap eases install • Wind-driven rain tested • Mill and black finish solaredge.com SolarEdge Home Hub Inverter Single Phase, for North America For Inverters Assembled in the USA SE3800H-US / SE5700H-US / SE7600H-US / SE10000H-US / SE11400H-US Single phase inverter for storage and backup applications The ultimate home energy manager in charge of PV production, battery storage, backup operation during a power outage*, EV Charging, and smart energy devices Record-breaking 99% weighted efficiency with up to 300% DC oversizing Supports LRA – can provide the required energy for HVAC systems starting during backup operation Integrates seamlessly with the complete SolarEdge Home Smart Energy Ecosystem, through SolarEdge Home Network Module-level monitoring and visibility of battery status, PV production, and self- consumption data Fast and easy installation – small and lightweight, with reduced commissioning time A scalable solution that supports future homeowner needs through easy connection to a growing ecosystem of products Advanced safety features with integrated arc fault protection and rapid shutdown for 690.11 and 690.12 Advanced reliability with automotive-grade components Embedded revenue grade production data, ANSI C12.20 Class 0.5 IP65-rated, for indoor and outdoor installations HOME BACKUP 12-25 YEAR WARRANTY *Requires additional hardware and firmware version upgrade. © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 19, 2024 DS-000229-NAM. Subject to change without notice. SolarEdge Home Hub Inverter Single Phase, for North America SE3800H-US / SE5700H-US / SE7600H-US / SE10000H-US / SE11400H-US Model Number(1)(2) SE3800H-US SE5700H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT – AC ON GRID Rated AC Power 3800 @ 240V 3300 @ 208V 5760 @ 240V 5000 @ 208V 7600 10000 11,400 @ 240V 10,000 @ 208V W Maximum AC Power Output 3800 @ 240V 3300 @ 208V 5760 @ 240V 5000 @ 208V 7600 10000 11,400 @ 240V 10,000 @ 208V W AC Output Voltage (Nominal) 208 / 240 Vac AC Output Voltage (Range) 183 – 264 Vac AC Frequency Range (min - nom - max) 59.3 – 60 – 60.5(3) Hz Maximum Continuous Output Current 16 24 32 42 48 A GFDI Threshold 1 A Total Harmonic Distortion (THD) < 3 % Power Factor 1, adjustable -0.85 to 0.85 Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Charge Battery from AC (if allowed) Yes Typical Nighttime Power Consumption < 2.5 W OUTPUT – AC STAND-ALONE (BACKUP)(4)(5) Rated AC Power in Stand-alone Operation 11,400(6) W Maximum Stand-alone Capacity 11,400 W AC L-L Output Voltage Range in Stand-alone Operation 211 – 264 Vac AC L-N Output Voltage Range in Stand-alone Operation 105 – 132 Vac AC Frequency Range in Stand-alone (min - nom - max) 55 – 60 – 65 Hz Maximum Continuous Output Current in Stand-alone Operation 48 A GFDI 1 A THD < 5 % OUTPUT – SOLAREDGE HOME EV CHARGER AC Rated AC Power 9600 W AC Output Voltage Range 211 – 264 Vac On-Grid AC Frequency Range (min - nom - max) 59.3 – 60 – 60.5 Hz Maximum Continuous Output Current @240V (grid, PV and battery) 40 Aac INPUT – DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kΩ Sensitivity INPUT – DC (PV) Maximum DC Power @ 240V 11,400 11,520 15,200 20,000 22,800 W Maximum DC Power @ 208V 6600 10,000 - - 20,000 W Maximum Input Current(7) @ 240V 20 30.5 40 53 60 Adc Maximum Input Current(7) @ 208V 17.5 27 - - 53 Adc Maximum Input Short Circuit Current 45 Adc Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 98.5 99 99 @ 240V 98.5 @ 208V % 2-pole Disconnection Yes (1) These specifications apply to inverters with part numbers SExxxxH-USMNUxxx5 and SExxxxH-USMNFxxx5 and connection unit model number DCD-1PH-US-PxH-F-x. (2) Inverters with part number SExxxxH-USMNFxxx5 are intended for upgrade installations only, as part of the “Re-Energize” program. Use on non-upgrade installations will revoke the product warranty. (3) For other regional settings please refer to the SolarEdge Inverters, Power Control Options Application Note. (4) Not designed for non-grid connected applications and requires AC for commissioning. Stand-alone (backup) functionality is only supported for the 240V grid. (5) For LRA (Locked Rotor Amperage) values please refer to the LRA for NAM Application Note. (6) For models SE7600H-US and below, the rated AC stand-alone power is configurable between 7600W or 11,400W from CPU version 4.20.xx. (7) A higher current source may be used. The inverter will limit its input current to the values stated. © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 19, 2024 DS-000229-NAM. Subject to change without notice. SolarEdge Home Hub Inverter Single Phase, for North America SE3800H-US / SE5700H-US / SE7600H-US / SE10000H-US / SE11400H-US Model Number(1)(2) SE3800H-US SE5700H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT – DC (BATTERY) Supported Battery Types SolarEdge Home Battery, LG RESU Prime Number of Batteries per Inverter Up to 3 SolarEdge Home Battery, up to 2 LG RESU Prime Continuous Power(8) 11,400 @ 240V 3800 @ 208V 11,400 @ 240V 5000 @ 208V 11400 @240V 11,400 @ 240V 10,000 @ 208V W Peak Power(8) 11,400 @ 240V 3800 @ 208V 11,400 @ 240V 5000 @ 208V 11400 @240V 11,400 @ 240V 10,000 @ 208V W Maximum Input Current 30 Adc 2-pole Disconnection Up to the inverter’s rated stand-alone power SMART ENERGY CAPABILITIES Consumption Metering Built-in(9) Stand-alone & Battery Storage With Backup Interface (purchased separately) for service up to 200A; up to 3 inverters EV Charging Direct connection to the SolarEdge Home EV Charger ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Cellular(10), Wi-Fi (optional), SolarEdge Home Network (optional) Revenue Grade Metering, ANSI C12.20 Built-in(9) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi Access Point for local connection DC Voltage Rapid Shutdown (PV and Battery) Yes, NEC 690.12 STANDARD COMPLIANCE Safety UL 1741, UL 1741SA, UL 1741SB, UL 1699B, CSA 22.2#107.1, C22,2#330, C22.3#9, ANSI/CAN/UL 9540 Grid Connection Standards IEEE1547 and IEEE-1547.1, Rule 21, Rule 14H Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Terminals L1, L2, N terminal blocks, PE busbar for inverter connection L1, L2 terminal blocks, PE busbar for EV Charger AC connection DC Terminals 4 x terminal block pairs for PV input; 1 x terminal block pair for battery input AC Output and EV AC Output Conduit Size / AWG Range 1'' maximum / 14-4 AWG DC Input (PV and Battery) Conduit Size / AWG Range 1'' maximum / 14-6 AWG Dimensions with Connection Unit (H x W x D) 21.06 x 14.6 x 8.2 / 535 x 370 x 208 in / mm Weight with Connection Unit 44.9 / 20.3 lb / kg Noise < 50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(11) ˚F / ˚C Protection Rating NEMA 4X (8) Discharge power is limited up to the inverter’s rated AC power for on-grid and stand-alone applications, as well as up to the installed batteries’ rating. (9) For consumption metering current transformers should be ordered separately: SECT-SPL-225A-T-20 or SEACT1250-400NA-20. Revenue grade metering is only for production metering. (10) Information concerning the data plan terms & conditions is available in SolarEdge Communication Plan Terms and Conditions. (11) Full power up to at least 50°C / 122°F; for power derating information refer to the Temperature Derating Technical Note for North America. solaredge.com SolarEdge is a global leader in smart energy technology. By leveraging world-class engineering capabilities and with a relentless focus on innovation, SolarEdge creates smart energy solutions that power our lives and drive future progress. SolarEdge developed an intelligent inverter solution that changed the way power is harvested and managed in photovoltaic (PV) systems. The SolarEdge DC optimized inverter maximizes power generation while lowering the cost of energy produced by the PV system. Continuing to advance smart energy, SolarEdge addresses a broad range of energy market segments through its PV, storage, EV charging, UPS, and grid services solutions. SolarEdge @SolarEdgePV @SolarEdge_US SolarEdge North America SolarEdge www.solaredge.com/corporate/contact solaredge.com © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 19, 2024 DS-000229-NAM Subject to change without notice. Cautionary Note Regarding Market Data and Industry Forecasts: This brochure may contain market data and industry forecasts from certain third-party sources. This information is based on industry surveys and the preparer’s expertise in the industry and there can be no assurance that any such market data is accurate or that any such industry forecasts will be achieved. Although we have not independently verified the accuracy of such market data and industry forecasts, we believe that the market data is reliable and that the industry forecasts are reasonable.