Loading...
HomeMy WebLinkAbout1025 Hudson Avenue_AA 2024-0827Sarah Andrews, President HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY CERTIFICATE OF APPROPRIATENESS The Historic Preservation Commission of South Bend and St. Joseph County has approved the following work: Remove and replace existing asphalt shingles with CertainTeed Landmark architectural shingles. Work to include installation of new drip edge, ice and water shields, synthetic underlayment, coil nails, plumbing boots, chimney flashing, can or ridge vents, and ridge cap shingles. No gutter or soffit work to be performed. AJ Roofing, Contractor for the following location: 1025 HUDSON AVE South Bend, IN, 46616 Riverside Drive Application No. 2024-0827 in the County of St. Joseph; State of Indiana; which is: Located in a Local Historic District A Local Historic Landmark and found this application to be appropriate according to the Standards pertaining to Local Historic Landmarks and/or Local Historic Districts. Regulations pertaining to the Historic Preservation Commission are found in Chapter 21 (Zoning), South Bend Municipal Code and Chapter 26 of the St. Joseph County Code. The issuance of this certificate does NOT in any manner, release the recipient from the responsibility of complying with the requirements of the zoning ordinances, building codes, safety codes, ADA or other requirements of the City of South Bend, the County of St. Joseph, the State of Indiana, or the United States Federal Government. This certificate is good for one year from the date of issuance and is effective from the date entered herein. Plans are on file and open for public inspection at the office of the Historic Preservation Commission of South Bend and St. Joseph County, 227 West Jefferson Blvd., Suite 1400 S, South Bend, Indiana, during normal business hours. THIS CERTIFICATE IS NOT TRANSFERABLE NAME OF APPLICANT:Doug Gibson CERTIFICATE ISSUED BY: Kate Himick Historic Preservation Specialist POST IN A CONSPICUOUS PLACE ON THE STREET SIDE OF THE PROJECT UNTIL COMPLETION OF ALL WORK. Phone: (574) 235-9371 E-mail: SBSJCHPC@southbendin.gov ROSS VAN OVERBERGHE Historic Preservation Administrator 8/29/2024DATE CERTIFICATE TAKES FORCE:8/29/2025DATE CERTIFICATE EXPIRES: Ord No. 7469-85 Riverside Drive ADMINISTRATIVE APPROVAL Tuesday, August 27, 2024 Application for Cer tificate of Appropriateness Important Information Regarding this Request REQUIRED DOCUMENTATION AND SITE PLANS The Historic Preservation Commission of South Bend and St. Joseph County cannot process an Application without required documentation. Comprehensive documentation provides a complete understanding of the project. Problems often occur during a project review or during the execution of the project when the property owner, staff or commissioners are unclear as to project specifics. Applications will NOT be processed without required documentation. Photographs may be submitted in digital format or in photographic print. When a project involves blueprints and/or site plans, one (1) set shall be submitted with the Application. Any documentation submitted to this office cannot be returned to the applicant. APPLICATION FEE The application processing fee for any Application for a Certificate Of Appropriateness is $20 Payment must accompany the application at the time of submission. For an electronically submitted application, payment must reach the HPC office within 48 hours following transmission. Payment can be made by credit card by contacting Business License Administrator Michelle Adams at (574) 235-5912; by cash in person in the Department of Community Investment on the 14th floor of the County City Building; or by check made out to City of South Bend. Applications will NOT be processed without the required fee. MEETING ATTENDANCE When an Application has been scheduled for any meeting, the owner, architect or contractor(s) retained for the project shall attend the meeting where their project will be reviewed and a decision rendered. Failure by the owner, architect, or contractor to attend such meetings may result in denial of the Application due to insufficient representation. CERTIFICATE ISSUANCE Certificates of Appropriateness will be filed with the Building Department of South Bend and St. Joseph County. A copy of the Certificate will be emailed directly to the owner and/or contractor(s) listed on the application. INSPECTION AUTHORITY All projects will be inspected during and following execution for compliance with the decision(s) rendered by the Historic Preservation Commission of South Bend and St. Joseph County. Owner acknowledges that while the Historic Preservation Commission only considers Certificates of Appropriateness for exterior features, under certain circumstances it may be necessary for the Commission Staff to have access to the interior of the building in order to accurately assess the condition of the exterior feature and that the lack of access to the interior may prevent the Commission Staff from making a favorable recommendation. Any work performed on a historic landmark or in an historic district which does not conform to the Certificate of Appropriateness certificate shall be immediately halted by the Historic Preservation Commission and the Building Department of South Bend and St. Joseph County. Fines may be levied for projects not in compliance. I read and understand the information above:Yes, Continue Date Tuesday, August 27, 2024 1 Property Information Property Address for Proposed Work:1025 Hudson Ave Property City South Bend Property Zip Code 46616 Property Owner Information:Doug Gibson Owner Email Proposed Work and Project Information All projects must comply with applicable building and zoning codes. South Bend Zoning Ordinance St. Joseph County Zoning Ordinance Does your project involve any of the following? (Check all that apply):Roofs Contractor Information AJ Roofing Roofs Abby Hill Contractor Phone Number (574) 674-4226 Contractor Email aj_construction@sbcglobal.net Description of Proposed Work: -Cover and protect any existing landscaping, exterior furniture, etc. at perimeter of work area -Tear off old shingles and all other roof material - 1 Layer Included. -Remove all existing nails on roof deck -Address any sheeting problems if necessary-up to 3 sheets included in price or 100 SF. $45.00 per sheet thereafter, if necessary -Install new drip edge on roof - Clay - Install new certainteed rolling roofing system to low slope areas -Re-flash chimney (if applicable) -Install Ice and Water Shield, eave ends & in all valleys & penetrations -Install synthetic underlayment to roof -Install starter shingles -Install new Certainteed Landmark architectural shingles -Install new coil nails -Install new plumbing boots -Install new can or ridge vents -Install new ridge cap shingles 2 August 29, 2024 MA Rec. 626133 $20.00 Specification of Material via Manufacture Brochure: 7.31 MB PDF LM& LM Pro ….pdf File Upload Site Plans, Aerial Views, and/or Blueprints: One (1) set shall be submitted with the Application. Uploaded documentation must show existing property lines, buildings, structures, and proposed project location(s). Hand Drawn Plans/Elevations are ok Photographs to include: each area affected by project, close up detail of project areas. Windows, Siding, and/or Door projects must include photographs of each window/door/siding affected by the project and detailed close up of condition Applications will not be processed if the required photographs and/or documentation are not included. Any documentation submitted to this office cannot be returned to the applicant. Project Type - List:Roofs Overhead View of Proposed Project Location(s):PDF 61048783 (1).pdf Quote/Evaluation(s) by Repair Professional (Optional): 87_Screenshot 2024-08-27 at 1.11.09 PM… 7.31 MB 3 Photographs: PDF 89_61048783 (1)_614.pdf I have included all required photographs and documentation for my application, as described above. I understand these items will not be returned. I Affirm Signature of Proper ty Owner: Payment Invoice ID # INV-000065 Payment Method Pay in Person 4 Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. Measurements provided by www.eagleview.com www.eagleview.com/Guarantee.aspx In this 3D model, facets appear as semi-transparent to reveal overhangs. PREPARED FOR Contact:Josh Hill Company:AJ Construction & Roofing Address:54698 Kristi Lane Osceola, IN 46561 Phone:574-674-4226 TABLE OF CONTENTS Images .....................................................................1 Length Diagram .........................................................4 Pitch Diagram ............................................................5 Area Diagram ............................................................6 Notes Diagram ...........................................................7 Report Summary ........................................................8 Total Roof Area =1,572 sq ft Total Roof Facets =6 Predominant Pitch =7/12 Number of Stories >1 Total Ridges/Hips =53 ft Total Valleys =24 ft Total Rakes =153 ft Total Eaves =108 ft MEASUREMENTS Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 IMAGES © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 1 The following aerial images show different angles of this structure for your reference. Top View Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 IMAGES © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 2 North Side South Side Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 IMAGES © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 3 East Side West Side Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 LENGTH DIAGRAM © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 4 Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5.0 Feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). Total Line Lengths: Ridges = 53 ft Hips = 0 ft Valleys = 24 ft Rakes = 153 ft Eaves = 108 ft Flashing = 31 ft Step flashing = 54 ft Parapets = 0 ft 2117 2117 +9 12121010 17 10 10+9 131321 +6+98 16 14 +919 14 127 1815 +918 S N W E ©2024 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 PITCH DIAGRAM © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 5 Note: This diagram contains labeled pitches for facet areas larger than 20.0 square feet. In some cases, pitch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 7/12 2 +67 7 +67 S N W E ©2024 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 AREA DIAGRAM © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 6 Note: This diagram shows the square feet of each roof facet (rounded to the nearest Foot). The total area in square feet, at the top of this page, is based on the non-rounded values of each roof facet (rounded to the nearest square foot after being totaled). Total Area = 1,572 sq ft, with 6 facets. 144 351 273 128 546 128 S N W E ©2024 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 NOTES DIAGRAM © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 7 Note: This diagram also appears in the Property Owner Report. Roof facets are labeled from smallest to largest (A to Z) for easy reference. C E D A F B S N W E ©2024 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 REPORT SUMMARY © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 8 All Structures Areas per Pitch Roof Pitches Area (sq ft) % of Roof 2/12 6/12 7/12 351.3 256.6 963.7 22.3%16.3%61.3% The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch. Structure Complexity Simple Normal Complex Waste Calculation NOTE: This waste calculation table is for asphalt shingle roofing applications. All values in table below only include roof areas of 3/12 pitch or greater. For total measurements of all pitches, please refer to the Lengths, Areas, and Pitches section below. Waste %0%5%10%13%15%17%20%25%30% Area (Sq ft)1221 1283 1344 1380 1405 1429 1466 1527 1588 Squares *12.33 13.00 13.66 14.00 14.33 14.33 14.66 15.33 16.00 Measured Suggested * Squares are rounded up to the 1/3 of a square Additional materials needed for ridge, hip, and starter lengths are not included in the above table. The provided suggested waste factor is intended to serve as a guide—actual waste percentages may differ based upon several variables that EagleView does not control. These waste factor variables include, but are not limited to, individual installation techniques, crew experiences, asphalt shingle material subtleties, and potential salvage from the site. Individual results may vary from the suggested waste factor that EagleView has provided. The suggested waste is not to replace or substitute for experience or judgment as to any given replacement or repair work. All Structures Totals Total Roof Facets = 6 Lengths, Areas and Pitches Ridges = 53 ft (4 Ridges) Hips = 0 ft (0 Hips). Valleys = 24 ft (2 Valleys) Rakes† = 153 ft (13 Rakes) Eaves/Starter‡ = 108 ft (9 Eaves) Drip Edge (Eaves + Rakes) = 261 ft (22 Lengths) Parapet Walls = 0 (0 Lengths). Flashing = 31 ft (5 Lengths) Step flashing = 54 ft (6 Lengths) Predominant Pitch = 7/12 Total Area (All Pitches) = 1,572 sq ft Property Location Longitude = -86.2647793 Latitude = 41.6922052 Notes This was ordered as a residential property. There were no changes to the structure in the past four years. S N W E ©2024 Eagle View Technologies, Inc., All Rights Reserved.† Rakes are defined as roof edges that are sloped (not level). ‡ Eaves are defined as roof edges that are not sloped and level. Premium Report 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 9 Online Maps Online map of property http://maps.google.com/maps?f=g&source=s_q&hl=en&geocode=&q=1025+Hudson+Avenue,South+Bend,IN,46616 Directions from AJ Construction & Roofing to this property http://maps.google.com/maps?f=d&source=s_d&saddr=54698+Kristi+Lane,Osceola,IN,46561&daddr=1025+Hudson+Avenue,South+ Bend,IN,46616 Legal Notice and Disclaimer 8/21/2024 1025 Hudson Avenue, South Bend, IN 46616 Report: 61048783 IMPORTANT LEGAL NOTICE AND DISCLAIMER © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. Notice and Disclaimer No Warranty: The Copyrighted Materials are provided to you "as is," and you agree to use it at your own risk. EagleView Technologies makes no guarantees, representations or warranties of any kind, express or implied, arising by law or otherwise, including but not limited to, content, quality, accuracy, completeness, effectiveness, reliability, fitness for a particular purpose, usefulness, use or results to be obtained from the Copyrighted Materials. Contractors agree to always conduct a preliminary site survey to verify Roof Report ordered. In the event of an error in a Report, your sole remedy will be a refund of the fees paid by you to obtain this Report.