Loading...
HomeMy WebLinkAbout411 West North Shore Drive_AA 2023-0601ASarah Andrews, President HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY CERTIFICATE OF APPROPRIATENESS The Historic Preservation Commission of South Bend and St. Joseph County has approved the following work: Removal / replacement of rubber roofing material on sun porch. AJ CONSTRUCTION & HOME IMPROVEMENTS, Contractor for the following location: 411 NORTH SHORE DR South Bend, IN, 46617 West North Shore Drive Application No. 2023-0601A in the County of St. Joseph; State of Indiana; which is: Located in a Local Historic District A Local Historic Landmark and found this application to be appropriate according to the Standards pertaining to Local Historic Landmarks and/or Local Historic Districts. Regulations pertaining to the Historic Preservation Commission are found in Chapter 21 (Zoning), South Bend Municipal Code and Chapter 26 of the St. Joseph County Code. The issuance of this certificate does NOT in any manner, release the recipient from the responsibility of complying with the requirements of the zoning ordinances, building codes, safety codes, ADA or other requirements of the City of South Bend, the County of St. Joseph, the State of Indiana, or the United States Federal Government. This certificate is good for one year from the date of issuance and is effective from the date entered herein. Plans are on file and open for public inspection at the office of the Historic Preservation Commission of South Bend and St. Joseph County, 227 West Jefferson Blvd., Suite 1400 S, South Bend, Indiana, during normal business hours. THIS CERTIFICATE IS NOT TRANSFERABLE NAME OF APPLICANT:Robert Jones CERTIFICATE ISSUED BY: Adam Toering Historic Preservation Administrator POST IN A CONSPICUOUS PLACE ON THE STREET SIDE OF THE PROJECT UNTIL COMPLETION OF ALL WORK. Phone: (574) 235-9371 E-mail: SBSJCHPC@southbendin.gov ADAM TOERING Historic Preservation Administrator 6/1/2023DATE CERTIFICATE TAKES FORCE:6/1/2024DATE CERTIFICATE EXPIRES: Ord No. 6512-78 West North Shore Drive ADMINISTRATIVE APPROVAL /eagleview, REPORT DETAILS 8/12 0/12 1/12 2/12 #1 25.1 squares 7 10% 73% 14% 11% 1% 8/12 #2 5 squares 2 14% 100% -Does NOT include waste Measurements provided by www.eaaleview.can Note: Atggested waste fa" can be applied to roof areas Wveted wide aSMM resMentlal ShIMIe5 twat are a p1Cw Of 3/12 ar greater. To learn more, pease visit this -. tge_base article. 0 i! Certified Accurate �...n a.<.....n,00r.ro�..,. team more M www eaaleview.com/Guamnwe.asm Bid Perfect" April 21, 2023 M 2023 Bagk New TethnWii ea, Inc. W Plctanetn InRmn.1 r+a'0. - all aghts ReservM - C re try me a mote d U.S. PM t Ws. 8,078,4%; 8,145,578; 8,170,W; 8,209,152; 8,515,125; 9,183,538: 8,818,770; 8,542,880; 9,2*1,589; 9,329,749. ONer Patents Petblrq. q1West North ?_ my South Bend, IN 46617 �yyy. '� A 4' Z �. . feglev -- Report: 51945923 Fj eagleview- IMAGES The following aerial images show different angles of this structure for your reference. North View East View South View West View Bid PerfectTM April 21, 2023 © 2 20231a0 Vi Te hrn qg , Inc. aM VKLaiCpY lnlen al Cap. - M Rght RBErv01- CoxrM By aie a mae M U.S. Pa Nos. 8,V8,436; 8,145,578; 8,120,040; 8,2N,152; 8,515,125; 9,183,538; 8,818,770, 8,592,M; 9,244,58 9,329,149, MN Pah M IW ISure -Seal® EPDM Dusted Non -Reinforced Membranes Overview Carlisle's Sure -Seal EPDM Dusted Non -Reinforced membranes are available in thicknesses of 45-mil (1.14 mm) and 60-mil (1.52 mm), widths of up to 50' (15 m), and lengths of up to 200' (60 m). Ideal for new construction and re -roofing applications, this membrane is available in a Fire Retardant (FR) version that is specially formulated to inhibit the spread of flame and meet or exceed code body testing criteria for fire - retardant roofing membranes. Features and Benefits n Carlisle EPDM has 50 years of proven performance and industry - leading resistance to weathering, with 41,580 kJ/mz total radiant exposure without cracking or crazing • Factory -Applied Tape" seam technology and a full line of Pressure - Sensitive flashing accessories enhance workmanship quality u Dark -colored EPDM is the smart choice in colder climates: - Reduces heating costs, which are generally 3-5 times greater than air conditioning costs - Reduces carbon footprint by lowering heating costs - Reduces safety hazards from snow and ice accumulation - Reduces hazardous conditions caused by frost, dew, and ice - Reduces the potential for condensation problems Life Cycle Assessment using EPA's TRACI model analyzed EPDM, TPO, PVC and Modified Bitumen: - EPDM had the lowest global warning potential - EPDM had the lowest acid rain impact - EPDM had the lowest contribution to smog SYNTEC SYSTEMS Numerous studies and real -world experience confirm that Sure -Seal EPDM's 465% elongation and weathering resistance result in superior hail damage resistance (UL 2218 Class 4 Rating) EPDM is the most dimensionally stable, heat -resistant membrane, and stays flexible even in extremely cold conditions down to -40OF (-400C): see flexibility/torsion DMA data u Wide array of design choices that are UL Classified and FM Approved • Industry -leading 15-, 20-, and 25-year warranties are available • Carlisle manufactures all the major components of a typical roofing system, including membrane, flashings, tapes, adhesives, sealants, insulations, and insulating cover boards Carlisle's Factory -Applied Tape Seam Technology The Factory -Applied Tape process results in a reliable seam with no entrapped air bubbles. Consistent placement of the Factory -Applied Tape maximizes the splice area resulting in a high -quality seam. Factory - Applied Tape has a shelf life of one year. Productivity Boosting Features and Benefits: • With Carlisle's Factory -Applied Tape, most of the �ctrvlrr labor to create seams between membrane panels is oo % r completed in a quality -controlled, state-of-the-art a _ Q environment • Factory -Applied Tape is available on all Sure -Seal , r ¢Q membranes up to 30' (9 m) in width, providing the Boost fastest way to complete a seam in today's roofing market a Wider sheets like 165, 20% and 25' reduce the frequency of seams compared to 10'-wide sheets Installation Sure -Seal 45-mil (1.14 mm) and 60-mil (1.52 mm) membranes are typically utilized in Design A: Fully Adhered (60-mil only), Design B: Ballasted, and Design C: Loose -Laid Protected roofing systems. Stagger factory seams to avoid a double thickness of membrane in the splice area. For Design A: Fully Adhered Hoofing System Insulation is mechanically attached or adhered to the roof deck. The substrate and membrane are coated with the appropriate Carlisle bonding adhesive. The membrane is then rolled into place and broomed down. To complete seams between two adjoining membrane panels, apply primer to the splice area in conjunction with Carlisle's Factory -Applied Tape. As an alternative, Carlisle's hand -applied SecurTAPE'" may be used. 800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislasyntec.com ISure -Seal EPDM Dusted Non -Reinforced Membranes For Design B: Ballasted Roofing System Insulation is loose -laid over the roof deck. Membrane is loose -laid over the insulation with staggered factory seams and secured with a minimum 10 Ibs (4.5 kg) of ballast per square foot. Design C is a similar system with the insulation installed on top of the membrane. To complete seams between two adjoining membrane panels, apply primer to the splice area in conjunction with Carlisle's Factory -Applied Tape. As an alternative, Cadisle's hand -applied SecurTAPE may be used. Follow these steps for splicing in temperatures below 400F (50C): 1. Heat the primed area of the bottom membrane with a hot-air gun as the top sheet with Factory -Applied Tape is applied and pressed into place. 2. Prior to rolling the splice area with a 2"-wide steel hand roller, apply heat to the top side of the membrane with a hot-air gun. The heated surface should be hot to the touch. Be careful not to burn or blister the membrane. Review Carlisle specifications and details for complete installation information. Precautions » Use proper stacking procedures to ensure sufficient stability of the materials. » Exercise caution when walking on wet membrane. Membranes are slippery when wet. » Membranes with Factory -Applied Tape should not be exposed to prolonged jobsite storage temperatures in excess of 90»F (320C), otherwise the shelf life of the tape may be affected. » When membranes with Factory -Applied Tape are used in warm, sunny weather, shade the tape end of the rolls until ready to use. Stagger factory seams to avoid a double thickness of membrane. » Carlisle Factory -Applied Tape has a shelf life of one year. Pre -consumer Recycled Content 5% Post -consumer Recycled Content 0% Manufacturing Locations Carlisle, PA Greenville, IL Solar Reflectance Index 9 Corporate Sustainability Report I yes �= SYNTEC SYSTEMS Typical..- and Characteristics Physical Property Test Method SPEC. (PASS) Typical 45_mll BO-mil Toleranceon NomkelTMclowsk% ASTM D412 z10 ±10 x10 Weight, IbmnP(kg/" 0.29(1.4) 0.39(1.9) Tensile Strength, min, psi (MPa) ASTM D412 1305 g) 1600 (11.0) 1600 (11.0) Elongation, ultimate, min,% ASTM D412 300 480 465 Tear Strength, min, Ibf/ln (kN/m) ASTM D624 150 (26.3) 200 (35o) 200 (35.0) (Ole C) Factory Seam Strength, min Modified Membrane Membrane Membrane ASTM D816 Rupture Rupture Rupture ASTM D573 Resistance to Heat Aging- Properties after 28 days 240-F(116'C) Tensile Strength, min, psi (MPa) ASTM D412 1205 (8.3) 1500 (10.3) 1450 (10.0) Elongation, Ultimate, min, % ASTM D412 200 225 280 Tear Strength, min, Ibf/in (kN/m) ASTM D624 125 (21.9) 215 (37.6) 215 (37.6) Linear Dimensional Change, max,% ASTM of204 z1.0 -0.4 -0.50 Ozone Resistance ASTM D1149 No Cracks No Cracks No Cracks CoMxan after exposure to 100 pphm Once in air for 168 hours 0104-F (40-C) Specimen Is at 50%straln BrNtleness Temp., max,'F ('C)' ASTM D746 -411l -49 (-45) -49 (-45) ASTM D471 +8, -2 +2.0 +2.0 Resistance to water Absorpdore After 7 days immersion of 158-F (70-C) Change in mass, max, % ASTM E96 0.10 0.05 0.03 Water Vapor Permeance- Max. perms (Proc.8 or OW) ASTM N/A 225 MPa 225 MPa Rexlbllity/Torslon OMA 05279-08 ® -40'F 0 40'F Fungi Resistance ASTM G21 N/A 0 0 (No 6mwth) (No Growth) ASTM G155 No Cracks No Cracks No Cracks Resistance to Outdoor (Uhravioleq Weathering' No Craarg No Crazing No Crating Xenon -Arc. total radiant exposure 7.560 kJ/Mr 41,580 kJ/mr 41,580 Unix at 0.70 Wlmr irradiance, 80'C 3,000 hm 16.500 the 16,500 bra black panel temperature 6,000 bra 33,000 hrs 33,000 hra At 0,35 Wlmr irradiance. 80-C black panel temperature 'Not a quality control test due to the time required for the test or the complexity of the test. However, all tests are run on a statistical basis to ensure overall long-term performance of the sheeting. Typical properties and characteristics am owed on samples tested and are rat guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. Note: Sure -Seal Dusted Non -Reinforced EPDM membrane meats or exceeds the minimum requirements set forth by ASTM D4637 for Type I non -reinforced EPDM single -ply roofing membranes. 800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislesyntec.com 04.26.21 02021 Cadlele. Carlisle, Sue-Sel, Factory -Applied Tape, and SecurTAPE are bademarn of Carlisle. PERMIT CODE: 605438 EPDM-1119 -"Sun-Seal EPDM Dusted No -Reinforced Membrane Product Data Sheet" LEED is a registered trademark of the U.S. Green Building Council.