HomeMy WebLinkAbout211 North Michigan Street_AA 2022-0719Michele Gelfman, President HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY CERTIFICATE OF APPROPRIATENESS The Historic Preservation Commission of South Bend and St. Joseph County has approved the following work: 1) Replacement of existing roof membrane (Midland Engineering), 2) Installation of new HVAC units/exhausts on roof (Contractor TBD), TBD, Contractor for the following location: 211 MICHIGAN ST South Bend, IN, 46615 Application No. 2022-0719 in the County of St. Joseph; State of Indiana; which is: Located in a Local Historic District A Local Historic Landmark and found this application to be appropriate according to the Standards pertaining to Local Historic Landmarks and/or Local Historic Districts. Regulations pertaining to the Historic Preservation Commission are found in Chapter 21 (Zoning), South Bend Municipal Code and Chapter 26 of the St. Joseph County Code. The issuance of this certificate does NOT in any manner, release the recipient from the responsibility of complying with the requirements of the zoning ordinances, building codes, safety codes, ADA or other requirements of the City of South Bend, the County of St. Joseph, the State of Indiana, or the United States Federal Government. This certificate is good for one year from the date of issuance and is effective from the date entered herein. Plans are on file and open for public inspection at the office of the Historic Preservation Commission of South Bend and St. Joseph County, 227 West Jefferson Blvd., Suite 1400 S, South Bend, Indiana, during normal business hours. THIS CERTIFICATE IS NOT TRANSFERABLE NAME OF APPLICANT:South Bend Redevelopment Authority CERTIFICATE ISSUED BY: Adam Toering Historic Preservation Administrator POST IN A CONSPICUOUS PLACE ON THE STREET SIDE OF THE PROJECT UNTIL COMPLETION OF ALL WORK. Phone: (574) 235-9371 E-mail: SBSJCHPC@southbendin.gov ADAM TOERING Historic Preservation Administrator 7/21/2022DATE CERTIFICATE TAKES FORCE:7/21/2023DATE CERTIFICATE EXPIRES: ADMINISTRATIVE APPROVAL MIDLAND ENGINEERING CO., INCPH: 574-272-0200FAX: 574-272-740052369 STATE ROUTE 933 N.SOUTH BEND, IN 46637A-1SHEET 1 OF 7SYMBOL KEYROOF PLANISSUE:DATE:DRAWN BY:APPROVAL4/19/2022 MJAREVISION 16/29/2022CAHMORRIS PERFORMING ARTSCENTER & PALAIS ROYALERE-ROOF211 N. MICHIGANSOUTH BEND, IN 46601&105 W. COLFAX AVESOUTH BEND, IN 46601GENERAL NOTES1)ROOF SYSTEM NEEDS TO MEET 20 YEAR WARRANTYREQUIREMENTS2)REVIEW CONSTRUCTION DRIVEN MOISTURE SUBMITTAL3)MEMBRANE PROTECTION- CLEAN ANY DEBRIS OFF THE INSTALLED MEMBRANE- INSTALL A MINIMUM 11 OZ. FELT, CARPET, OR INSULATION- INSTALL A MINIMUM 1/2" PLYWOOD OVER THE FELT, CARPET, ORINSULATION- FOR ANY SOLDERING OR WELDING USE PROPER APRONS OVERTHE PLYWOOD- PROTECT ALL DETAILS - CURBS, VENTS, PIPES, ETC.- ANY DAMAGE MUST BE MARKED ON THE ROOF AND BROUGHT TOTHE ROOFING APPLICATORS ATTENTION SO IMMEDIATE REPAIRSCAN BE COMPLETED- DAMAGE OR ABUSE IS NOR COVERED WITHIN THE SCOPE OF THEWARRANTY4)ANY GYPSUM SHEATHING THAT WILL BE REQUIRED TO BE COVEREDWITH MEMBRANE ROOFING MUST BE DENS DECK PRIME(EXAMPLES: BACK SIDE OF PARAPET WALLS, EXTERIOR SHEATHINGON STUDS WALLS, ETC.)5)PVC SYSTEMS ONLY: ASPHALT BASED WEATHER/AIR BARRIERSCANNOT BE IN CONTACT WITH ROOFING MEMBRANE. ASEPARATION BETWEEN THE TWO MUST BE INSTALLED6)ALL VERTICAL TERM BAR MUST BE CAULKED ON BOTH SIDES. ALLFASTENER HEADS MUST BE CAULKED7)T-JOINT & BLOW-OUT PATCH REQUIREMENTSSARNAFIL - T-JOINTS REQUIRED ON ALL JOBS WITH .072 AND GREATERMEMBRANE - BLOW-OUT PATCHES NOT REQUIRED1A-41A-43A-4LOWHIGH3A-4LOW3A-4LOW1A-43A-4LOWHIGH3A-4LOW1A-43A-4LOWHIGH4A-41A-41A-41A-41A-41A-41A-41A-41A-41A-4HIGHHIGHHIGHHIGH8A-48A-42A-4HIGH1A-41A-41A-42A-41A-42A-42A-42A-41A-41A-41A-41A-41A-45A-41A-55A-46A-46A-45A-45A-45A-45A-5TYP5A-5TYP2A-5TYP3A-54A-5TYP6A-56A-53A-4LOW3A-4LOW3A-4LOW3A-4LOW3A-4LOW3A-4LOW3A-4LOW5A-45A-41A-4HIGH3A-4LOW7A-57A-46A-5ROOF PLANSCALE: 1/8" = 1'-0" MIDLAND ENGINEERING CO., INCPH: 574-272-0200FAX: 574-272-740052369 STATE ROUTE 933 N.SOUTH BEND, IN 46637A-2SHEET 2 OF 7SYMBOL KEYFASTENINGPLANISSUE:DATE:DRAWN BY:APPROVAL4/19/2022 MJAREVISION 16/29/2022CAHMORRIS PERFORMING ARTSCENTER & PALAIS ROYALERE-ROOF211 N. MICHIGANSOUTH BEND, IN 46601&105 W. COLFAX AVESOUTH BEND, IN 46601ROOF SYSTEM#1ROOF SYSTEM#1ROOF SYSTEM#1ROOF SYSTEM#1ROOF SYSTEM#1ROOF SYSTEM#1ROOF SYSTEM#1ROOF SYSTEM#1FASTENING PATTERN INFORMATIONROOF INFORMATION:INSULATIONPERIMETERWIDTH:ISO FASTENING:ROOF SYSTEM 1: CONCRETE ROOF DECK, EXISTING 3" INSULATION TO REMAIN, NEW FIBERTITE .045 SMFB MEMBRANE (ADHERED W/ CR-20 SPATTER SPAY ADHESIVE)N/AN/AEXISTING CONCRETEDECK TO REMAINEXISTING 3"INSULATION TOREMAINNEW FIBERTITE .045 SMFB MEMBRANE ADHEREDW/ CR-20ROOF SYSTEMS PLANSCALE: 3/32" = 1'-0"ROOF SYSTEM LAYOUT #1SCALE: N.T.S. Seaman Corporation’s 45 mil FiberTite-SM-FB “fleece back” features an 18 x 19 / 840 x 1,000 denier weft reinforced polyester knit fabric, coated with a proprietary compound, utilizing DuPont’s™ Elvaloy® Ketone Ethylene Ester (KEE) as the principle polymer in the hybrid vinyl alloy coating. Product Data MEMBRANE 45 mil FiberTite-SM-FB DESCRIPTION PHYSICAL PROPERTIES 45 mil FiberTite-SM-FB “fleece back” is a 40-oz sq. yd/nominal 45-mil (1.1 mm) thick membrane. 45 mil FiberTite-SM-FB not only meets or exceeds the minimum physical property requirements enumerated in ASTM D6754-15 Standard Specification for Ketone Ethylene Ester (KEE) Based Sheet Roofing, but exceeds the physical properties and performance characteristics of 60-mil competitive products. The 45 mil FiberTite-SM-FB membrane incorporates a 4-oz per sq. yd non-woven polyester felt, heat bonded to the back side of the membrane with a 3-in selvedge edge for field welding. 45 mil FiberTite-SM-FB fleece back is manufactured in conventional 72- in by 80-ft roll goods. Seaman Corporation is vertically integrated, which allows complete control over the manufacturing process from the selection of the yarns, to the engineering, knitting and weaving of the base fabrics to the final coating process. Today, FiberTite Roofing Membranes are the result of Seaman Corporation’s 60 years of applied fabric engineering and coating technology. All FiberTite Roofing Membranes are constructed using high tenacity/heavy weight yarns to create a base fabric reinforcement to impart superior puncture, tensile and tear resistance properties. The base polyester fabrics are primed with a unique and proprietary adhesive coat that lays the foundation to physically bond the KEE coatings to the “fiber” to maximize seam strength and overall membrane performance. 45 mil FiberTite-SM-FB is coated on the face with Seaman Corporation’s original “KEE” formulation to provide superior hot air welding characteristics, extreme UV resistance, broad chemical resistance and long-term flexibility and reparability for the installed roofing membrane system. The back side of the membrane is coated with a slightly modified (SM) economical version of Seaman Corporation’s original KEE compound to control membrane costs while offering additional thickness and weather ability. Additionally, 45 mil FiberTite-SM-FB exhibits excellent tear, puncture, fungus, algae and flame resistance that make FiberTite Roofing Systems some of the most sustainable roofing systems available. ASTM D6754-15 Minimum Requirements 45 mil-FB Typical Thickness, mm (in.) ASTM D 751 0.81 (0.032)1.14 (0.045 nom.) Thickness over Fiber, mm (in) Optical method (inches) 0.18 (0.007).37 (0.0145) Breaking Strength, N (lbf) ASTM D 751 proc. B - strip 1499 (338)1557 (350) Elongation at Break, % ASTM D 751 - strip 18 18 Tear Strength, N (lbf) ASTM D 751 Proc. B. Tongue Tear 338 (76)445 (100) Linear Dimensional Change ASTM D 1204 max (%) 1.3 0.63 Fabric Adhesion, N/m (lbf/in) ASTM D 751 3330 (19)no peel Retention of Properties after Heat Aging ASTM D 3045 - 176°f/56 days Breaking Strength, strip, % original Elongation at Break, strip, % original 90 90 90 90 Low Temperature Bend after Heat Aging -30 -40 Low Temperature Bend ASTM D 2136 (°f) -30 -40 Change in Weight after Exposure in Water D 471 158°f, 166 h, one side only, max. (%) 0.0, +6.0 0.0, +3.7 Factory Seam Strength, N (lbf) ASTM D 751 Grab Method 1955 (440)> Fabric Break Hydrostatic Resistance, Mpa (psi) ASTM D751 4.1 (590)5.2 (750) Static Puncture Resistance ASTM D 5602 (99 lbf) pass pass Dynamic Puncture Resistance (J) ASTM D 5635 10 25 For more information on FiberTite Systems and accessories please call: Seaman Corporation (800) 927-8578 International (330) 262-1111 www.fibertite.com FiberTite® is a registered trademark of Seaman Corporation. Subject to the conditions of Approval for a roof covering when installed as described in the current edition of the Approval Guide. As to an external fire exposure only. See UL directory of products certified for Canada and UL roofing materials and systems directory 34KL, 48PO, 97P9. DC196 These specifications are current as of the date of printing. Revisions or additions may be issued periodically. For a listing, presentation, and download of the most recent data, visit: www.fibertite.com/document-library/product-data-sheets FTRDS04_03 Product Data APPLICATION PHYSICAL PROPERTIES (cont.) 45 mil FiberTite-SM-FB Roofing Systems are installed by adhering the “fleece back” membrane in FTR-290 low VOC solvent borne adhesive, FTR-390 water borne asphalt emulsion, FTR-490 water borne elastomeric adhesive, FTR CR-20, or hot asphalt to a variety of pre-approved substrates. For specific installation recommendations and requirements, please consult the most current versions of Seaman Corporation’s Guide Specifications for the Installation of FiberTite Roofing Systems. 45 mil FiberTite-SM-FB Accelerated Weathering Practice G 155 / xenon 5000hr >10000hr cracking (7x magnification)none none crazing (7x magnification)none none Accelerated Weathering Practice G 154 / UVA 5000hr >10000hr cracking (7x magnification)none none crazing (7x magnification)none none Fungi Resistance Sustained Growth Practice G 21, 28 days Discoloration no growth none no growth none Abrasion Test, cycles D 3389 H-18 wheel / 1,000 g load 1,500 2,000+ Additional Physical Properties Tensile Strength (psi) ASTM D882 8500 Breaking Strength (lbs) ASTM D751, Grab Method 450 Puncture Resistance (lbs) ASTM D751, Bursting Strength 350 Water Vapor Transmission ASTM E96 proc. A (gm/m2/24hrs) 1.3 Shore A Hardness ASTM D2240 87 Flame Resistance MIL-C-20696C / Type II Class 2 pass Oil Resistance, MIL-C 20696C No swelling, cracking or leaking none Hydrocarbon Resistance, MIL-C-20696C No swelling, cracking or leaking none High Temperature Dead Load ASTM D751 (50 lbs, 160°F, 4 hrs) pass Energy Attributes DC196 Off White DC6 White DC691 CR Gray DC667 CR Tan Initial Solar Reflectance ASTM C1549 0.83 0.87 0.69 0.72 Solar Reflectance (3 yr aged) ASTM C1549 0.66 0.71 .61 .63 Initial Thermal Emittance ASTM C1371 0.85 0.85 0.89 0.88 Thermal Emittance (3 yr aged) ASTM C1371 0.74 0.84 .89 .89 Solar Reflective Index (SRI) ASTM E1980 104 110 84 88 Solar Reflective Index (SRI) (3 yr aged) ASTM E1980 76 86 73 76 Energy Star YES YES YES YES LEED v4 - Heat Island Reduction SS Credit 1 Credit 1 Credit 1 Credit 1 Credit ADHESIVE Seaman Corporation supplies Polyset® CR-20® polyurethane foam adhesive for installing Fleece Back Membrane in authorized FiberTite Roofing Systems. CR-20 is a two component elastomeric polyurethane designed to provide outstanding adhesive properties. Product Data Polyset® CR-20® Polyurethane Foam Adhesive DESCRIPTION APPLICATION Polyset CR-20 is used to adhere FiberTite Fleece Back membranes to a variety of approved substrates including polyisocyanurate insulation board, gypsum based coverboards, structural concrete and smooth bituminous roofs. Substrate Preparation: All surfaces to be bonded must be clean, dry and free of any debris that would interfere with the proper application of the fleece back membrane. CR-20 is a single surface adhesive. It is spray applied in a “Spatter Pattern” onto the roof, insulation or coverboard by dispensing the adhesive in a spray pattern similar to the action required when hand watering a flower bed. The spatter pattern should yield a heavily textured coating of approximately ¼” to ½” nominal thickness height on the peaks of the spatter. The seams of the membrane and factory selvedge edge must be protected from overspray of the CR-20. If overspray does contaminate the seam area(s), immediately clean the seam area with acetone while the CR-20 is still wet. The bonding range for the CR-20 is approximately 1-10 minutes from the start of spraying and will vary according to ambient as well as substrate temperature. The amount of substrate area that the CR-20 is applied to ahead of the membrane should be monitored to prevent installing the membrane in dry adhesive. Care must be taken, particularly in high temperature environments, (90°F and above) to insure that the CR-20 has not dried or skinned over prior to embedding the fleece back membrane. Refer to FiberTite Specifications for additional instruction in the use of CR-20. Subject to the conditions of Approval for a roof covering when installed as described in the current edition of the Approval Guide. These specifications are current as of the date of printing. Revisions or additions may be issued periodically. For a listing, presentation, and download of the most recent data, visit: www.fibertite.com/document-library/product-data-sheets For more information on FiberTite Systems and accessories please call: Seaman Corporation (800) 927-8578 International (330) 262-1111 www.fibertite.com FiberTite® is a registered trademark of Seaman Corporation. Polyset® & CR-20® are registered trademarks of ICP Adhesives and Sealants. FTRDS31_04 STORAGE & HANDLING The “A” and “B” containers shall be stored between 45°F and 95°F. The shelf life, at these temperatures is 18 months from the date of production. The product temperature prior to application shall be between 70°F and 90°F. The minimum ambient and surface temperature shall be 40°F and rising. Temperatures outside the stated ranges may affect the bonding range, dispensability and overall performance of the product. Cylinder Disposal: Disposable Cylinders shall be disposed of in accordance with local, state and federal regulations. Consult MSDS for more information.