Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
333 Tonti Street_AA 2022-0614
Michele Gelfman, President HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY CERTIFICATE OF APPROPRIATENESS The Historic Preservation Commission of South Bend and St. Joseph County has approved the following work: Removal / Replacement of existing asphalt shingle roof with new asphalt shingle roof. Installation of new decking. RELIABLE ROOFING, Contractor for the following location: 333 TONTI AVE South Bend, IN, 46617 Application No. 2022-0614 in the County of St. Joseph; State of Indiana; which is: Located in a Local Historic District A Local Historic Landmark and found this application to be appropriate according to the Standards pertaining to Local Historic Landmarks and/or Local Historic Districts. Regulations pertaining to the Historic Preservation Commission are found in Chapter 21 (Zoning), South Bend Municipal Code and Chapter 26 of the St. Joseph County Code. The issuance of this certificate does NOT in any manner, release the recipient from the responsibility of complying with the requirements of the zoning ordinances, building codes, safety codes, ADA or other requirements of the City of South Bend, the County of St. Joseph, the State of Indiana, or the United States Federal Government. This certificate is good for one year from the date of issuance and is effective from the date entered herein. Plans are on file and open for public inspection at the office of the Historic Preservation Commission of South Bend and St. Joseph County, 227 West Jefferson Blvd., Suite 1400 S, South Bend, Indiana, during normal business hours. THIS CERTIFICATE IS NOT TRANSFERABLE NAME OF APPLICANT:Angel Cortes CERTIFICATE ISSUED BY: Adam Toering Historic Preservation Administrator POST IN A CONSPICUOUS PLACE ON THE STREET SIDE OF THE PROJECT UNTIL COMPLETION OF ALL WORK. Phone: (574) 235-9371 E-mail: SBSJCHPC@southbendin.gov ADAM TOERING Historic Preservation Administrator 6/17/2022DATE CERTIFICATE TAKES FORCE:6/17/2023DATE CERTIFICATE EXPIRES: ADMINISTRATIVE APPROVAL Page 1 of 7 Page 2 of 7 Page 3 of 7 Page 4 of 7 Page 5 of 7 Page 6 of 7 Page 7 of 7 Technical Data Sheet Landmark®TL Shingles PRODUCT INFORMATION: The Landmark®TL shingles are constructed using three laminated layers of the industry’s most durable materials, providing a dramatically thick roofing product styled with the classic appeal of wood shakes. The overall dimensions of this shingle are 13 1/4" x 40". It is designed to resist blow off in high wind conditions up to 110-mph with normal installation and 130-mph with special installation. Landmark TL algae resistant (AR) shingles help protect against staining or discoloration caused by algae. AR shingles are not available in California. Colors:Please refer to product brochure or CertainTeed website for the colors available in your region. Limitations:It is recommended to apply these shingles at slopes of 4" per foot and greater in order to achieve optimum appearance. Low slope applications (2:12 to < 4:12) require CertainTeed’s WinterGuard£Waterproofing Shingle Underlayment, or its equivalent meeting ASTM D1970, to be applied to the entire deck surface, according to application instructions provided with the product and on the shingle package. In areas where icing along the eaves can cause the back-up of water (all slopes); apply WinterGuard, or its equivalent, according to application instructions provided with the product and on the shingle package. Product Composition:Landmark TL shingles are composed of a fiber glass mat base. Ceramic-coated mineral granules are tightly embedded in carefully refined, water-resistant asphalt. Three pieces of the shingle are firmly laminated together in a special, tough asphaltic cement. All Landmark TL shingles have self-sealing adhesive strips. Applicable Standards: ASTM D3018 Type 1 ASTM D3462 ASTM E108 Class A Fire Resistance ASTM D3161 Class F Wind Resistance ASTM D7158 Class H Wind Resistance UL 790 Class A Fire Resistance ICC-ES ESR-1389 & ESR-3537 CSA Standard A123.5 Miami-Dade County Product Control Approved Florida Product Approval # FL5444 Meets TDI Windstorm Requirements Technical Data: Weight/Square (approx.): 305 lb. Dimensions (overall): 13 1/4"x 40" Shingles/Square: 64 Weather Exposure: 5-5/8" INSTALLATION Detailed installation instructions are supplied on each bundle of Landmark TL shingles and must be followed. Separate application sheets may also be obtained from CertainTeed. Hips and Ridges:For a complementary color, use CertainTeed’s Shadow Ridge £or CertainTeed’s enhanced high profile accessory shingle, Mountain Ridge £, of a like color name for capping with hips and ridges. Technical Data Sheet Landmark TL Shingles Page 2 of 2 MAINTENANCE Landmark TL shingles do not require maintenance when installed according to manufacturer's application instructions. However, to protect the investment, any roof should be routinely inspected at least once a year. Older roofs should be looked at more frequently. WARRANTY Landmark TL shingles carry a lifetime limited, transferable warranty against manufacturing defects. In addition, all Landmark TL shingles carry 10-year SureStart™ Protection. For specific warranty details and limitations, refer to the warranty itself (available from the local supplier, roofing contractor or on-line at www.certainteed.com ). FOR MORE INFORMATION Sales Support Group: 800-233-8990 Web site: www.certainteed.com See us at our on-line specification writing tool, CertaSpec, at www.certainteed.com/certaspec. CertainTeed 20 Moores Road Malvern, PA 19355 © 02/21 CertainTeed