Loading...
HomeMy WebLinkAboutIndustrial Wastewater Discharge Permit Renewal - St. Joseph Energy Center6 City of South Bend Department of Public Works Industrial Pretreatment Program Significant Industrial User – Permit No. 381723-121232 In accordance with all the terms of Chapter 17 of the City of South Bend’s Municipal Code, and with any applicable provisions of federal or state law and regulations, permission is hereby granted to: St. Joseph Energy Center 54745 Walnut Rd. New Carlisle IN 46552 for the contribution of wastewater into the City of South Bend Publicly Owned Treatment Works. This permit is granted in accordance with the application filed on 15 February, 2022. Effective on: 1 June, 2022 Expires on the: 31 May, 2027 Any violation of the terms and conditions of this permit shall be deemed a violation of the City of South Bend Municipal Code and will subject the permittee to the sanctions set out in section 17-11 through 17-13 of the Municipal Code. The permittee shall file an application for a renewal permit, a minimum of 90 days prior to the expiration date. Approved By: April 12, 2022 4 PERMIT BRIEFING MEMO 1. Facility Description St. Joseph Energy Center is an Electric Power Generation Facility that engages in the production of electricity using natural gas in a combustion turbine. This facility operates 24 hours / 7 days per week on two 12-hour shifts. Production is subject to seasonal variation. The facility is manned by 21 plant personnel. 2. Discharge Description Generated discharge flows consist of processes and equipment/ facility wash-downs and storm water from the five (5) Transformers’ secondary containment. The metering station is located in an above ground unit called a Hot Box (to protect the meter from weather conditions), which is inside the fence on SJEC property along Walnut Road and downstream of the OWS unit. From January 1, 2017 to December 31, 2021 Average Process Flow: 17,427gpd Maximum Process Flow: 108,970gpd 3. Sample Site Description Sample Site #054 is located adjacent to the Hot Box location. Sample Site #054 is considered to be end- of-process. 4. Wastewater Treatment Pretreatment of wastewater consists of an Oil Water Separator. 5. Classification St. Joseph Energy Center is classified as a Categorical Industrial User (CIU) by the Steam Electric Power Generating Point Source under 40 CFR 423.17 New Source Performance Standards according to the facility’s NPDES Permit Fact Sheet provided by St. Joseph Energy Center. St. Joseph Energy Center has reported that wastewater regulated under 40 CFR 423.17 is only directly discharged to the designated NPDES discharge point, not discharged to the sewer. The City’s Industrial Pretreatment Program states that all Categorical Industrial Users be classified at a minimum as a B. Therefore, St. Joseph Energy Center is classified as a B industry. 6. Calculation of Limits Local limits have been applied where appropriate as described in Chapter 17 of the City of South Bend Municipal Code. St. Joseph Energy CenterIndustrial Wastewater Discharge Permit page 10 of 41 PART II - MONITORING REQUIRMENTS A. Monitoring Frequency 1. The following parameters shall be monitored at the frequency and with the sampling type stated below. All measurements, tests, and analyses of the characteristics of water and wastes to which reference is made in this permit shall be conducted using the methods and procedures approved in 40 CFR 136 and amendments thereto, unless otherwise specified in an applicable Categorical Pretreatment Standard. The following parameters shall be monitored at Sample Site Outfall # 054 with the methods and at the frequency stated below: Parameter Sampling Frequency Sampling Type Flow, total (gpd) Daily Continuously Flow Monthly (gal) Monthly Continuously Ammonia, nitrogen (mg/L) Semi-Annual Composite Arsenic (mg/L) Semi-Annual Composite BOD5 (mg/L) Semi-Annual Composite Cadmium (mg/L) Semi-Annual Composite Chromium (mg/L) Semi-Annual Composite Copper (mg//L) Semi-Annual Composite Lead (mg/L) Semi-Annual Composite Nickel (mg/L) Semi-Annual Composite Mercury (mg/L) Semi-Annual Grab Oil & Grease, Total (mg/L) Monthly Grab Oil & Grease, TPH (mg/L) Semi-Annual Grab pH (SU) Monthly Grab Phosphorus (mg/L) Semi-Annual Composite Total Suspended Solids (mg/L) Semi-Annual Composite Silver (mg/L) Semi-Annual Composite Zinc (mg/L) Semi-Annual Composite See Flow Measurement Requirements referenced in Part III - Reporting Requirements.