Loading...
HomeMy WebLinkAboutIndustrial Wastewater Discharge Permit Renewal - Honeywell International, Inc. - TABLEDBOARD OF PUBLIC WORKS AGENDA ITEM REVIEW REQUEST FORM Date 7/26/2021 Name Serena Lozano-Shane Department UTILITIES BPW Date 8/10/2021 Phone Extension 5798 Review and Approval Required Prior to Submittal to Board Diversity Compliance and Inclusion Officer Officer Name BPW Attorney Attorney Name Dept. Attorney Attorney Name Purchasing Check the Appropriate Item Type – Required for All Submissions Professional Services Agreement Contract Proposal Open Market Contract Amendment/Addendum Special Purchase, QPA Bid Opening Bid Award Req. to Advertise Title Sheet Quote Opening Quote Award Reject Bids/Quotes Proposal Opening C/O & PCA No. PCA Chg. Order, No. Traffic Control Resolution x Other: Industrial Discharge Permit Modification Ease./Encroach Required Information Company or Vendor Name New Vendor Yes If Yes, Approved by Purchasing No MBE/WBE Contractor MBE WBE Completed E-Verify Form Attached Yes No Project Name Project Number Funding Source Account No. Amount Terms of Contract Purpose/Description _______________________________________________________________ _______________________________________________________________ ___________________________________________________ For Change Orders Only Amount of Increase Decrease $ ($ ) Previous Amount $ Current Percent of Change: Increase Decrease % ( %) New Amount $ Total Percent of Change: Increase Decrease % ( %) Time Extension Amount: New Completion Date:   City of South Bend Department of Public Works Industrial Pretreatment Program Remediation Site – Permit No. 004 In accordance with all the terms of Chapter 17 of the City of South Bend’s Municipal Code, and with any applicable provisions of federal or state law and regulations, permission is hereby granted to: Honeywell International, Inc. 3502 Westmoor Street South Bend, IN 46628 for the contribution of wastewater into the City of South Bend Publicly Owned Treatment Works. This permit is granted in accordance with the application filed on 14 January, 2020. Effective on: 14 April, 2020 Expires on the: 13 April, 2025 Revised on: August 10, 2021 Any violation of the terms and conditions of this permit shall be deemed a violation of the City of South Bend Municipal Code and will subject the permittee to the sanctions set out in section 17-11 through 17-13 of the Municipal Code. The permittee shall file an application for a renewal permit, a minimum of 90 days prior to the expiration date. Approved By: Board of Public Works _________________ Elizabeth A. Maradik, President _________________ Gary A. Gilot, Member _________________ Jordan V. Gathers, Member _________________ Josheph Molnar, Member _________________ Murray Miller, Member _________________ Attest: Anne Fuchs, Clerk   Honeywell Groundwater Remediation Industrial Wastewater Discharge Permit page 4 of 39 The following parameters shall be monitored at sample site 003C00175 with the methods and at the frequency stated below: Parameter Sampling Frequency Sampling Type Flow, Monthly (gal) Monthly Continuously Total Oil and Grease (mg/L) SemiAnnual Grab Oil and Grease TPH (mg/L) SemiAnnual Grab pH (SU) SemiAnnual Grab Ammonia, nitrogen (mg/L) Once per Permit Cycle Composite Arsenic (mg/L) Once per Permit Cycle Composite BOD5 (mg/L) Once per Permit Cycle Composite Cadmium (mg/L) Once per Permit Cycle Composite Chromium (mg/L) Once per Permit Cycle Composite Closed Cup Flashpoint (Degrees F) Once per Permit Cycle Grab Copper (mg/L) Once per Permit Cycle Composite Cyanide (mg/L) Once per Permit Cycle Grab Lead (mg/L) Once per Permit Cycle Composite Mercury (mg/L) Once per Permit Cycle Grab Nickel (mg/L) Once per Permit Cycle Composite Organic Priority Pollutants (ug/L) Once per Permit Cycle Grab Phosphorus (mg/L) Once per Permit Cycle Composite Silver (mg/L) Once per Permit Cycle Composite TSS (mg/L) Once per Permit Cycle Composite Zinc (mg/L) Once per Permit Cycle Composite A. Monitoring Definitions 1. Composite – Samples are obtained through flow-proportional sampling technique over a 24-hour period or for the duration of discharge within the 24-hour sampling period, including multiple batches of wastewater. If the permittee demonstrates that time-proportional sampling is accurate or as representative as flow-proportional sampling, then a time-proportional sample may be collected. a. If the permittee chooses to demonstrate that time-proportional sampling is accurate or as representative as flow-proportional sampling, the permittee must submit a request, which includes the certification statement found in Part III (A) (4) signed by the Authorized Representative [see Part IV (B) (15)], within 120 days of the effective date of this permit