HomeMy WebLinkAboutIndustrial Wastewater Discharge Permit Renewal - Imagineering Enterprises, Inc.BOARD OF PUBLIC WORKS
AGENDA ITEM REVIEW REQUEST FORM
Date 6/29/2021
Name Serena Lozano-Shane Department UTILITIES
BPW Date 7/13/2021 Phone Extension 5798
Review and Approval Required Prior to Submittal to Board
Diversity Compliance
and Inclusion Officer Officer Name
BPW Attorney Attorney Name
Dept. Attorney Attorney Name
Purchasing
Check the Appropriate Item Type – Required for All Submissions
Professional Services Agreement Contract Proposal
Open Market Contract Amendment/Addendum Special Purchase, QPA
Bid Opening Bid Award Req. to Advertise Title Sheet
Quote Opening Quote Award Reject Bids/Quotes
Proposal Opening C/O & PCA No. PCA
Chg. Order, No. Traffic Control Resolution
X Other: Industrial Permit Renewal Imagineering
Enterprises, Inc. Sample Street Location
Ease./Encroach
Required Information
Company or Vendor Name
New Vendor Yes If Yes, Approved by Purchasing
No
MBE/WBE Contractor MBE
WBE Completed E-Verify Form Attached Yes
No
Project Name
Project Number
Funding Source
Account No.
Amount
Terms of Contract
Purpose/Description _______________________________________________________________
_______________________________________________________________
___________________________________________________
For Change Orders Only
Amount of Increase
Decrease
$
($ )
Previous Amount $
Current Percent of Change:
Increase
Decrease
%
( %)
New Amount $
Total Percent of Change:
Increase
Decrease
%
( %)
Time Extension Amount:
New Completion Date:
6
City of South Bend
Department of Public Works
Industrial Pretreatment Program
Significant Industrial User – Permit No. 64117-34432
In accordance with all the terms of Chapter 17 of the City of South Bend’s Municipal Code, and with any applicable
provisions of federal or state law and regulations, permission is hereby granted to:
Imagineering Enterprises, Inc.
1302 West Sample Street
South Bend IN 46619-389
for the contribution of wastewater into the City of South Bend Publicly Owned Treatment Works.
This permit is granted in accordance with the application filed on 23 April, 2021.
Effective on: 9 August, 2021
Expires on the: 8 August, 2026
Revised: ___________
Any violation of the terms and conditions of this permit shall be deemed a violation of the City of South Bend Municipal
Code and will subject the permittee to the sanctions set out in section 17-11 through 17-13 of the Municipal Code.
The permittee shall file an application for a renewal permit, a minimum of 90 days prior to the expiration date.
Approved By: Board of Public Works
_____________ ____
Elizabeth A. Maradik, President
______________ ___
Gary A. Gilot, Member
____ _____________
Jordan V. Gathers, Member
______ ___________
Joseph Molnar, Member
____________________
Murray L. Miller, Member
______ ___________
Attest: Anne Fuchs, Clerk
July 13, 2021
Facility Description
Imagineering Finishing Technologies engages in corrosion protection, plating, and surface coating of various
metal alloys. Imagineering conducts Abrasive, solvent and/or chemical cleaning of alloy surfaces prior to treating
surfaces with phosphate (manganese or zinc) or chromium based compounds. Final surface treatment also
includes electroless nickel, conversion of aluminum, or painted materials. The process lines are named for the
process and for the tank size in the line. For example, the 300 EN Line has 300 gallon tanks for Electroless Nickel.
Imagineering facility employs 33 employees and operates 3 shifts, 5 days per week.
PART I – EFFLUENT LIMITATION
Sample Port and Collection Location
1. SS1 is located outside the main facility in a locked shed which is attached to the west wall of the
building. The wastewater discharge flows through a weir box for flow measurement in the shed
prior to discharge. The sample is collected in the discharge pipe after the final chamber of the
weir box. SS1 is both end-of-process and end-of-pipe (sanitary waste excluded).
2. Any discharge of water or waste having a pH lower than 6.0 S.U. or a pH higher than 11.0 S.U. is
prohibited. In addition, the permittee’s wastewater discharge shall not exceed the following effluent
limitations:
Effluent limitations for Sample Site Outfall # SS 1:
Parameter Daily Maximum Limit (mg/L) Monthly Average Limit (mg/L)
Arsenic (mg/L) Report* Report*
Cadmium (mg/l) Report* Report*
Chromium (mg/l) 2.77 1.71
Copper (mg/l) 3.38 0.8
Cyanide (mg/L) 1.2 0.65
Lead (mg/l) Report* Report*
Mercury (mg/L) 0.00019 -na-
Nickel (mg/l) 3.98 0.8
Oil & Grease (mg/l) 300 -na-
Oil & Grease TPH (mg/l) 100 -na-
Silver (mg/l) Report* Report*
TTO (mg/l) 2.13 -na-
Zinc (mg/l) 2.61 1.48
*Note: In accordance with the City of South Bend’s “What You Need Is What You Get” allocation method, local Daily
Maximum and Monthly Average limits have only been developed for those pollutants that have been observed at or above
certain concentrations in each Significant Industrial User’s wastewater discharge. If “Report” appears on the table, it has
been determined that an allocation of this pollutant is not necessary. The permittee shall compare any monitoring data for