Loading...
HomeMy WebLinkAbout863 Forest Avenue_COA 2021-0107STAFF REPORT CONCERNING APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS Date: January 13, 2021 Application Number: 2021-0107 Property Location: 863 Forest Avenue Architectural Style/Date/Architect or Builder: American Foursqaure-Free Classic / 1906 Property Owner: Mark Snell Landmark or District Designation: Chapin Park Local District #9574-05 Rating: Contributing DESCRIPTION OF STRUCTURE/ SITE: The home is a two story with a square floor plan set upon a brick foundation. The roof is hipped with a central gable dormer covered with asphalt shingles. There is a full front porch with full height Tuscan columns, with balusters with lattice below. The windows are 1/1 double hung. There are two front doors. ALTERATIONS: The house has been vinyl sided and has replacement storm windows. In 1942 the home was remodeled into a 2 family dwelling. The garage was added in 1949. In 1960 a new rear addition was built. AA #2020-0813 allowed for the reconstruction of the front porch and walk with aggregate concrete. COA #2009-0827 allowed for complete replacement of two awning windows with double hung 1/1 windows in the rear addition. COA #2006-0424 allowed for a tear-off and replacement with asphalt shingles. APPLICATION ITEMS: “Solar Panel installation, roof-mount, *(Please see attached Design Project Plans and Spec Sheet).” DESCRIPTION OF PROPOSED PROJECT: The applicant has requested approval to: i. Install eight “Cheetah HC 72M 390-410 Watt Mono Perc Half Cell Module solar panels on the south face of the roof on Iron Ridge XR-100 mounting rack; each panel with Enphase Microinverter. ii. Install a PV Solar Dedicated Load Center, AC Solar Disconnect, Generation Panel, Tesla Backup Gateway, and Power Wall on the rear addition, STANDARDS AND GUIDELINES: Chapin Park B. BUILDING SITE, LANDSCAPING & ACCESSORIES This section focuses on individual properties and amenities. Building sites tend to be irregularly shaped, of varying topography and with different setbacks with regard to plots. Alleys are generally behind houses. Landscape accessories like fences are unique to each structure. Chapin Place presents a unique situation within the district. Applications from properties that have property lines on Chapin Park will be considered on a case-by-case basis. Required Fencing, walkways, outbuildings, private yard lights, signs (i.e. house numbers) and benches (visible from the street) as well as trees located in a yard or tree lawn which reflect the property’s history and development shall be retained. A tree located in such areas shall only be removed if the removal is required due to storm damage, disease, threatened damage to a structure or for such other reason acceptable to the Historic Preservation Commission. Storm damage or diseased trees should then be replaced with an approved species at the same or approximate location wherever possible. Fencing visible from the street in front of the structure shall be open (meaning spaces between the pickets) and consistent with the historic character of a structure enclosed. Recommended New site work should be based upon actual knowledge of the past appearance of the property found in photographs, drawings and newspapers. New site work should also be appropriate to existing surrounding site elements in scale, type and appearance. Front yard areas should remain open. (See above for information regarding fences.) Trees in close proximity to a building may cause structural damage. Owners are encouraged to remove these trees and replace (or replant) them at a more appropriate location as soon as planting season permits and upon approval of a C of A. Prohibited No changes may be made to the appearance of the site by removing trees, fencing, walkways, outbuildings or other elements before evaluating their importance to the property’s history and development. Front yard areas shall not be transformed into parking lots nor paved nor blacktopped, nor enclosed by solid fences, chain link, nor industrial / commercial style fences. The installation of unsightly large devices, such as television satellite dishes, skylights or solar panels, shall not be permitted in areas where they detract from the architecture of a building, are intrusive to the public view of the building or are highly visible from a public street, or ruled inappropriate after Commission review. Utility poles with high-intensity overhead lights should be installed so that they cannot be seen from a street. The Commission will evaluate all installations as well as any potential exceptions resulting from special circumstances, before granting a C of A. […] E. MECHANICAL SERVICES The majority of the structures within the district have oil or gas heat, and have brick chimneys through the roof. Some houses have one or two window air conditioners. Required Required mechanical systems shall be placed in areas that will result in the least possible alteration of the structural integrity and physical appearance of the building. Recommended Solar collectors and TV dishes should be placed in the rear of the property and shielded by shrubbery and landscaping. Window air conditioners and exhaust fans should be installed at the rear or an inconspicuous side window. Original lighting fixtures should be utilized whenever possible. SITE VISIT REPORT: N/A STAFF RECOMMENDATION: Staff recommends approval for the project, contingent upon the solar panels being obscured from the street. Written by Adam Toering, Historic Preservation Specialist Prepared by Elicia Feasel, Historic Preservation Administrator HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY LOCATION MAP -Map showing location of the property and surrounding area (Google Maps) AERIEL MAP - Sanborn maps from 1917, 1945, and 1960. Satellite imagery from 2019. Phone: 574/235.9371 Parcel County Id: 018-1060-2558 owner Name: STACKHOUSE & ST. CLAIR HOLDINGS, LLC Property Address; 821 N ASHLAND AVE Pare� !itatel0:71-08-0.2:-405-015.000-026 Fax: 574/235.9021 Email: hpcsbsjc@southbendin.gov HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY County—City Building, South Bend, IN 46601 http://www.southbendin.gov/government/department/community-investment Phone: 574/235.9371 Fax: 574/235.9021 Email: hpcsbsjc@southbendin.gov Michele Gelfman, President A Certified Local Government of the National Park Service Elicia Feasel, Historic Preservation Administrator OFFICE USE ONLY>>>>>>DO NOT COMPLETE ANY ENTRIES CONTAINED IN THIS BOX<<<<<<OFFICE USE ONLY Date Received: ____________________ Application Number: ____________—___________________________________ Past Reviews: YES (Date of Last Review) _____________________________ NO Staff Approval authorized by: _________________________________________________________ Title: __________________________ Historic Preservation Commission Review Date: __________________________________________________________________________ Local Landmark Local Historic District (Name) ________________________________________ National Landmark National Register District (Name) _____________________________________ Certificate Of Appropriateness: Denied Tabled Sent To Committee Approved and issued: _____________________ Address of Property for proposed work: ________________________________________________________________________ (Street Number—Street Name—City—Zip) Name of Property Owner(s): __________________________________________________ Phone #: ______________________ Address of Property Owner(s): _______________________________________________________________________________ (Street Number—Street Name—City—Zip) Name of Contractor(s): _______________________________________________________ Phone #: ______________________ Contractor Company Name: __________________________________________________________________________________ Address of Contractor Company: ______________________________________________________________________________ (Street Number—Street Name—City—Zip) Current Use of Building: _____________________________________________________________________________________ (Single Family—Multi-Family—Commercial—Government—Industrial—Vacant—etc.) Type of Building Construction: ________________________________________________________________________________ (Wood Frame—Brick—Stone—Steel—Concrete—Other) Landscape New Replacement (not in-kind) Demolition Proposed Work: (more than one box may be checked) Description of Proposed Work: _______________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ Owner e-mail: __________________________________ and/or Contractor e-mail: ___________________________________ X _______________________________________________ and/or X _______________________________________________ Signature of Owner Signature of Contractor By signing this application I agree to abide by all local regulations related to project and to obtain a Building Department Permit, if applicable. —APPLICATION REQUIREMENTS ARE LISTED ON REVERSE SIDE— APPLICATION FOR A — CERTIFICATE OF APPROPRIATENESS 863 Forest Avenue, Apt. B, South Bend, IN 46616 Mark Snell 574-298-1830 (same) Residential, Multi-Family Solar Panel installation, roof-mount, *(Please see attached Design Project Plans and Spec sheet). Moxie Solar, CL #C118463 Moxie Solar, PO Box 703, North Liberty, IA 52317 Jennifer Chu (Hines), jch@moxiesolar.com C: 319-984-4843 Solar Panel installation, roof-mount, *(Please see attached Design Project Plans and Spec sheet). snellmark124@gmail.com jch@moxiesolar.com X Other DocuSign Envelope ID: 1E73F893-002E-4C7D-BAF4-98BB0F545C7B APPLICATION FEE The following schedule of fees shall apply to any Application for a Certificate Of Appropriateness: Routine Maintenance Exclusion (Staff Approval) $ 20.00 or Commission Review $ 20.00 Payment must accompany the application at the time of submission. For electronically submitted application, payment must reach the HPC office within 48-hours following transmission. REQUIRED DOCUMENTATION AND SITE PLANS The Historic Preservation Commission of South Bend and St. Joseph County cannot render judgment nor process an Application without specific documentation. Comprehensive documentation protects both the owner of the property submitting the Application as well as providing a complete understanding of the project for the commissioners and staff when rendering a decision. Problems often occur during a project review or during the execution of the project when one or both parties are unclear as to the specifics. Applications will NOT be processed without all required fees and documentation. When an Application has been scheduled for any meeting where a review and decision are to be rendered, the owner and any architect or contractor (s) retained for the project must attend such meetings. Failure by the owner, architect, or contractor to attend such meetings may result in denial of the Application due to insufficient representation. Documentation shall include: detailed written description of the project including materials to be used, scale, dimen- sions, construction methods, finishes, manufacturers’ brochures and specifications and photographs of the area(s) which the project will affect. Photographs may be submitted in digital format, or in photographic print. When a project involves blueprints and/or site plans, one (1) set shall be submitted with the Application. Any documentation submitted to this office cannot be returned to the applicant. INSPECTION AUTHORITY All projects will be inspected during and following execution, for compliance with the decision (s) rendered by the Historic Preservation Commission of South Bend and St. Joseph County. Owner acknowledges that while the Historic Preservation Commission only considers Certificates of Appropriateness for exterior features, under certain circumstances it may be necessary for the Commission Staff to have access to the interior of the building in order to accurately assess the condition of the exterior feature and that the lack of access to the interior may prevent the Commission Staff from making a favorable recommendation. Any work performed on a historic landmark or in an historic district which does not conform to the Certificate of Ap- propriateness certificate, shall be immediately halted by the Historic Preservation Commission and the Building De- partment of South Bend and St. Joseph County. INTERGOVERNMENTAL DISCLOSURE Certificates Of Appropriateness will be filed with the Building Department of South Bend and St. Joseph County when the applicant also is required to obtain a building permit or other such permit issued by that department . (The appli- cant may pick up their Certificate at that location). When no building or other permits are required from the Build- ing Department, the Certificate will be mailed directly to the applicant. DocuSign Envelope ID: 1E73F893-002E-4C7D-BAF4-98BB0F545C7B TO ENSURE YOUR APPLICATION CAN BE PROCESSED IN A TIMELY MATTER WITHOUT DELAY, PLEASE INCLUDE THE FOLLOWING DOCUMENTATION, PER STAFF DISCRETION: ALL PROJECTS: ___ Certificate of Appropriateness application ___ Application fee $20.00 ___ Written description (existing condition, evaluation by repair professional) ___ Overview of project (materials, scale, dimensions, construction methods, alterations, etc.) ___ Photographs (full front from street view, each side effected by project, close up detail of project areas) ___ Specification of material (either manufacture brochure or link to product online) NEW CONSTRUCTION, ADDITIONS, FENCES, LANDSCAPING: ___ Site Plan* or Aerial View depicting existing property lines, buildings, structures and proposed project locations ROOFS: ___ Site Plan* of building only overview showing building footprint and proposed project locations WINDOWS, SIDING: ___ Elevations* (Existing and proposed new) ___ Evaluation / Quote by repair professional DEMOLITION (MANDATORY COMMISSION REVIEW): ___ Site Plan* or Aerial View depicting existing property lines, buildings, structures and proposed project locations ___ Structural drawings / Architectural drawings UPON REQUEST BY STAFF: ___ Blueprints ___ Drawings ___ Other * Hand drawn is acceptable x x *(to be paid over the phone by Moxie Solar, Jennifer Chu (Hines)). x x x x x x x x Solar Panel installation, roof-mount, *(Please see attached Design Project Plans and Spec sheet). DocuSign Envelope ID: 1E73F893-002E-4C7D-BAF4-98BB0F545C7B C O N T R A C T O RMOXIE SOLAR(855) 669-4387INFO@MOXIESOLAR.COM323 W CHERRY STNORTH LIBERTY, IA 52317O W N E RMARK SNELL(574) 298-1830SNELLMARK124@GMAIL.COM863 FOREST AVENUE, APT. BSOUTH BEND, IN 46616A H JU T I L T YR E V I S I O N SPROJECT NAME: SNELL, MARK12-3029-11/6/21 PLAN SET CLINDIANA MICHIGANPOWER CO(260) 408-3558CITY OF SOUTH BEND(574) 235-9554125 S LAFAYETTE BLVDSOUTH BEND, IN 46601DESIGN SUMMARY01DESIGN SUMMARY·SIZE: 3.200 kW PV Solar System (8 modules)·STYLE: Residential, asphalt shingle roof, flush mount, grid tied, net-metered·LOCATION: South facing roof of home·ORIENTATION: Portrait, 40° pitch, 179° azimuth·MODULE: JinKO JKM-400M-72H 400W, 79.06"x 39.45"x 1.57" thick, 49.6 lbs·RACKING: Iron Ridge XR-100 with asphalt shingle roof flashings·INVERTER: Enphase IQ7+ MicroInverters·VOLTAGE: 120/240V, 1Φ·MONITORING: Enphase Enlighten Online Monitoring·ADDITIONAL NOTES: Finished attic, home is split into 3 meters - only connecting to oneTHIS DISTRIBUTED GENERATION FACILITY WAS INSTALLEDIN ACCORDANCE WITH THE CURRENT STATE ADOPTEDNATIONAL ELECTRICAL CODE101SITE MAPNO SCALENPV Solar ArrayRoof of buildingEnphase MicroinverterArrayPV Solar Dedicated Load CenterBuilding ExteriorMain Service PanelBuilding Interior - BasementUtility MeterBuilding ExteriorML CPAC Solar DisconnectBuilding ExteriorDP O W E R W A L LPowerWallBuilding InteriorG PGeneration PanelBuilding ExteriorGTESLA Backup GatewayBuilding ExteriorMG PDGL CP O W E R W A L LDocuSign Envelope ID: 1E73F893-002E-4C7D-BAF4-98BB0F545C7B www.jinkosolar.com KEY FEATURES PID RESISTANT RESISTANT LOW LIGHT 2400 Pa 5400 Pa CONVERSION 390-410 Watt MONO PERC HALF CELL MODULE 5 Busbar Solar Cell 5 busbar solar cell adopts new technology to improve the efficiency of modules , offers a better aesthetic appearance, making it perfect for rooftop installation. Higher module conversion efficiency (up to 20.38%) benefit from half cell structure (low resistance characteristic). High Efficiency Low-light Performance Certified to withstand: wind load (2400 Pascal) and snow load (5400 Pascal). Severe Weather Resilience High salt mist and ammonia resistance certified by TUV NORD. Durability Against Extreme Environmental Conditions 12 Year Product Warranty 25 Year Linear Power Warranty LINEAR PERFORMANCE WARRANTY Cheetah HC 72M Positive power tolerance of 0~+3% PID CONVER Half Cell Mono PERC 72 Cell Excellent Anti-PID performance guarantee limited power degradation for mass production. PID Resistance ISO9001:2015, ISO14001:2015, OHSAS18001 certified factory IEC61215, IEC61730, UL1703 certified product PERC Cheetah Advanced glass and cell surface textured design ensure excellent performance in low-light environment. 83.1% 90% 97.5% 100% 15 12 25 yearsGuaranteed Power Performancelinear performance warranty Standard performance warrantyAddition a l v a l u e f r o m J i n k o S o l a r ’ s l i n e a r w a r r a n t y DocuSign Envelope ID: 1E73F893-002E-4C7D-BAF4-98BB0F545C7B -50 -25 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax -40℃~+85℃ 1000/1500VDC (IEC) 20A 0~+3% -0.35%/℃ -0.29%/℃ 0.048%/℃ 45±2℃ Current-Voltage & Power-Voltage Curves (390W) Temperature Dependence of Isc,Voc,Pmax Engineering Drawings Electrical Performance & Temperature Dependence SPECIFICATIONS The company reserves the final right for explanation on any of the information presented hereby. JKM390-410M-72H-(V)-A3-EN Irradiance1000W/m2 AM=1.5STC: Irradiance800W/m2 AM=1.5NOCT: *Powermeasurementtolerance:±3% WindSpeed1m/s CellTemperature25°C AmbientTemperature20°C 952mm 860mm1360mmH1002mm 2008mm5 10 15 20 25 30 35 40 45 500 0 2 4 6 8 10 12 0 50 150 100 200 250 300 350 400 JKM390M-72H-V STC NOCT STC NOCT STC NOCT JKM400M-72H-VJKM395M-72H-V JKM405M-72H-V STC NOCT JKM410M-72H-V JKM390M-72H JKM400M-72HJKM395M-72H JKM405M-72H JKM410M-72H STC NOCT Mechanical Characteristics CellType No.ofHalf-cells Dimensions Weight FrontGlass Frame JunctionBox OutputCables MonoPERC158.75×158.75mm 144(6×24) 2008×1002×40mm(79.06×39.45×1.57inch) AnodizedAluminiumAlloy IP67Rated 22.5kg(49.6lbs) 3.2mm,Anti-ReflectionCoating,HighTransmission,LowIron,TemperedGlass 27pcs/pallet,54pcs/stack,594pcs/40'HQContainer Packaging Configuration999999999999999999994.59 145.555 552.58 4035 ModuleType MaximumPower(Pmax) MaximumPowerVoltage(Vmp) MaximumPowerCurrent(Imp) Open-circuitVoltage(Voc) Short-circuitCurrent(Isc) ModuleEfficiencySTC(%) OperatingTemperature(℃) MaximumSystemVoltage MaximumSeriesFuseRating PowerTolerance TemperatureCoefficientsofPmax TemperatureCoefficientsofVoc TemperatureCoefficientsofIsc NominalOperatingCellTemperature(NOCT) Back A-A Current (A)Normalized Isc, Voc, Pmax (%)Power (W)Voltage (V)Cell Temperature (¥)SideFront (Twopallets=Onestack) TÜV1x4.0mm2, (+)290mm,(-)145mmorCustomizedLength Lenth:±2mm Width:±2mm Height:±1mm RowPitch:±2mm 19.38% 390Wp 41.1V 9.49A 49.3V 10.12A 294Wp 7.54A 39.1V 48.0V 8.02A 19.88% 400Wp 41.7V 9.60A 49.8V 10.36A 302Wp 7.66A 39.6V 48.5V 8.16A 19.63% 395Wp 41.4V 9.55A 49.5V 10.23A 298Wp 7.60A 39.3V 48.2V 8.09A 20.13% 405Wp 42.0V 9.65A 50.1V 10.48A 306Wp 7.72A 39.8V 48.7V 8.22A 20.38% 410Wp 42.3V 9.69A 50.4V 10.60A 310Wp 7.76A 40.0V 48.9V 8.26A DocuSign Envelope ID: 1E73F893-002E-4C7D-BAF4-98BB0F545C7B 230 Sugar Creek Lane North Liberty, Iowa 52317 (855) 699-4387 www.moxiesolar.com The MOXIE Way! 1.Never install multiple panel orientation on single roof 2.No Exposed Rail, Rails cut to size 3.Rail always matches panel; ie; black panel, black rail, silver panel, silver rail 4.Rail acts as conduit: . Wiring integrated within Rail, no visible wiring 5.All visual conduit painted with homeowner provided paint 6.Single day builds, no long term mess or traffic concerns 7.No construction debris left on site; cleaned up at the end of the day, No Smoking on site. 8.Electrical and building permits approved prior to construction 9.No Junction boxes on roof surface 10.Dedicated Customer Service Staff 1 DocuSign Envelope ID: 1E73F893-002E-4C7D-BAF4-98BB0F545C7B �.7:m .. ►CA16A m I MOMMEMOMM ,{ 1I Nl �y I � d M� F �c •t l =E8 � ry �,� Ila+'• IV III it ,o as PA' II Vnlia' �`• .Idlll��r�+� c