HomeMy WebLinkAbout1712 East Wayne Street_COA 2020-0616BSTAFF REPORT
CONCERNING APPLICATION FOR A
CERTIFICATE OF APPROPRIATENESS
Date: 10 July 2020
Application Number: 2020-0616B
Property Location: 1712 East Wayne Street
Architectural Style/Date/Architect or Builder: Tudor Revival / 1929
Property Owner: Steve and Sarah Priebe
Landmark or District Designation: East Wayne Street Local District #7796-
87
Rating: Notable
DESCRIPTION OF STRUCTURE/ SITE: Two and a half story frame, irregular plan house in the Tudor
Revival style with brick and half-timbering. The gabled roof has a cross hip roof, with molded raking trim and
asphalt shingles, and prominent brick chimney. Windows include eight-light casements, wood casings, some
brick or stone sills; 2nd floor section overhangs a bay window. A detached two car, two door garage stands to
the rear of the house.
ALTERATIONS: COA 2015-0601 allowed for the in-kind replacement of the old wood privacy fence. COA
2009-0522 allowed for tear off and installation of GAF-ELK Timberline asphalt shingles. COA 2000-0523
allowed for the installation of 38’ of cedar fencing from the adjacent property’s garage to the back corner of the
house. COA 1991-0730 allowed for the replacement of windows on the front bay and the west façade, removal of
the aluminum and interior storms and bevel exterior wood sills. COA 1988-0922 allowed for the replacement of
the storm door.
APPLICATION ITEMS: “Tear down top portion of chimney & relay, pour new 6” cap that will overhang the
chimney 1” for watershed.”
DESCRIPTION OF PROPOSED PROJECT: The applicant has retroactively requested approval to:
i. Deconstruct the top portion of the chimney and reconstruct it with new 8” brick of the
same size and configuration as existing, replicating the previous pattern,
ii. Construction of a new 6” concrete cap to overhang the chimney for watershedding
purposes
The brick pattern of this structure is one of the most character defining features. The chimney stack rises up out of
the valley in the gabled roof line, with approximately a footprint of 5’ by 3’, before tapering down to approximately
4’ x 18” all the way up to the three chimney caps. A decorative vertical bond of bricks stood proud of the regular
bonding about two-thirds of the way up of the narrowed section. Previous photographs of the chimney show that
instead of a concrete cap, the chimney was topped by a single course of bricks laid on end (a ‘header bond’),
slightly overhanging the chimney stack. The passage of time has discolored the brick of the house, this is visible
under the eaves and at other protected locations.
The new chimney configuration involved reconstructing the chimney approximately half the way up from the
reduction in footprint, with some of the height of the chimney being removed in the process. The vertical
decorative bonds have been replicated in new brick. The new 6” concrete cap overhangs the new work by 1”.
STANDARDS AND GUIDELINES: EAST WAYNE STREET
II. EXISTING STRUCTURES
I. EXISTING STRUTURES
A. BUILDING MATERIALS
Original exterior wall materials in the District include limestone, flagstone, stucco, clapboard, wood shingles,
sandstone and masonry block. In some instances, vinyl or aluminum siding have been applied over the original
surface
Required
Original exterior building materials shall be retained. Deterioration of wood materials shall be prevented through
repair, cleaning and painting. The existing or original architectural detail around windows, porches, doors and eaves
should be retained or replaced by replicas of the same design and materials when deteriorated beyond despair.
Masonry including brick, limestone, flagstone, sandstone and stucco shall be cleaned only when necessary to halt
deterioration or to remove stains, and shall be done with a method acceptable for the preservation of the surface: i.e.
low pressure water and soft natural bristle bushes. When repairing stucco, stucco mixture compatible in
composition, color and texture shall be used.
Recommended
Whenever possible, the original building materials should be restored. Metal or vinyl siding may be used when it is
the only alternative to maintaining or replacing the original surface material. When used over wood surfaces, this
siding should be the same size and style as the original wood. Every effort should be made to retain the original trim
around windows, doors, cornicles, gables, eaves and other architectural features. Ample ventilation must be
afforded the structure when metal or vinyl siding has been installed in order to prevent increased deterioration of the
structure from moisture and/or insects. Mortar joints should be repointed only when there is evidence of moisture
problems or when sufficient mortar is missing to allow water to stand in the mortar joint. Existing mortar shall be
duplicated in composition, color, texture, joint size, method of application and joint profile. It is emphasized that,
prior to initiating any restoration or rehabilitation effort, the property owner should contact the Historical
Preservation Commission of South Bend and St. Joseph County which is located in the County/City Building of
South Bend. The Commission is an invaluable source of information about all facets of rehabilitation and
restoration.
Prohibited
Wood siding shall not be resurfaced with new material which is inappropriate or was unavailable when the building
was constructed, such as artificial stone, brick veneer asbestos or asphalt shingles. Sandblasting or the use of harsh
detergents shall not be used on masonry including brick, stucco, limestone, flagstone and sandstone. This method of
cleaning erodes the surface material and accelerates deterioration. Brick surfaces shall not be painted unless they
had been painted originally. Repointing shall not be done with a mortar of high Portland cement content which can
often create a bond that is stronger than the building material. This can cause deterioration as a result of the
differing coefficient of expansion and the differing porosity of the material and the mortar, which can result in
serious damage to adjacent brick. Paint shall not be removed from masonry surfaces indiscriminately.
Not Recommended
Waterproof or water repellent coatings or surface consolidation treatments should not be used on masonry surfaces
unless required to solve a specific problem that has been studied and identified. Coatings are frequently unnecessary
and expensive, and can accelerate deterioration of the masonry. Mortar joints which do not need repointed should
not be repointed.
SITE VISIT REPORT: N/A
STAFF RECOMMENDATION: Staff recommends approval of the proposed project.
Prepared by
Adam Toering, Historic Preservation Specialist
Reviewed by
Elicia Feasel, Historic Preservation Administrator
HISTORIC PRESERVATION COMMISSION
OF SOUTH BEND AND ST. JOSEPH COUNTY
Phone: 574/235.9371 Fax: 574/235.9021 Email: hpcsbsjc@southbendin.gov
LOCATION MAP - Map showing location of the property and surrounding area (Google Maps).
LOCATION MAP - Map showing subject location and surrounding area ( 1960 Sanborn, 2020 MACOG)
HISTORIC PRESERVATION COMMISSION
OF SOUTH BEND AND ST. JOSEPH COUNTY
Phone: 574/235.9371 Fax: 574/235.9021 Email: hpcsbsjc@southbendin.gov
SUBJECT AREA: Photograph of the front of the house in June of 2020.
HISTORIC PRESERVATION COMMISSION
OF SOUTH BEND AND ST. JOSEPH COUNTY
Phone: 574/235.9371 Fax: 574/235.9021 Email: hpcsbsjc@southbendin.gov
SUBJECT AREA: Google Street View (2011) capture of chimney at left, photo as of June, 2020 at right.